Sunteți pe pagina 1din 7

Project Job Ref.

DeSimone Consulting Engineers Section Sheet no./rev.


1
Calc. by Date Chk'd by Date App'd by Date
EK 7/21/2015

COMBINED FOOTING ANALYSIS AND DESIGN (ACI318-11)


TEDDS calculation version 2.0.05.06

2' 3'' 2' 3''

2' 3''
6'

2' 3''
6'

Combined footing details


Length of combined footing; L = 6.000 ft
Width of combined footing; B = 6.000 ft
Area of combined footing; A = L B = 36.000 ft2
Depth of combined footing; h = 36.000 in
Depth of soil over combined footing; hsoil = 0.000 in
Density of concrete; conc = 150.0 lb/ft3

Column details
Column base length; lA = 18.000 in
Column base width; bA = 18.000 in
Column eccentricity in x; ePxA = 0.000 in
Column eccentricity in y; ePyA = 0.000 in
Soil details
Density of soil; soil = 120.0 lb/ft3
Angle of internal friction; = 25.0 deg
Design base friction angle; = 19.3 deg
Coefficient of base friction; tan() = 0.350
Allowable bearing pressure; Pbearing = 3.000 ksf
Axial loading on column
Dead axial load on column; PGA = 0.550 kips
Live axial load on column; PQA = 0.000 kips
Project Job Ref.

DeSimone Consulting Engineers Section Sheet no./rev.


2
Calc. by Date Chk'd by Date App'd by Date
EK 7/21/2015

Wind axial load on column; PWA = 1.200 kips


Total axial load on column; PA = 1.750 kips
Foundation loads
Dead surcharge load; FGsur = 0.000 ksf
Live surcharge load; FQsur = 0.000 ksf
Footing self weight; Fswt = h conc = 0.450 ksf
Soil self weight; Fsoil = hsoil soil = 0.000 ksf
Total foundation load; F = A (FGsur + FQsur + Fswt + Fsoil) = 16.200 kips

Horizontal loading on column base


Dead horizontal load in x direction; HGxA = 0.000 kips
Live horizontal load in x direction; HQxA = 0.000 kips
Wind horizontal load in x direction; HWxA = 0.520 kips
Total horizontal load in x direction; HxA = 0.520 kips
Dead horizontal load in y direction; HGyA = 0.000 kips
Live horizontal load in y direction; HQyA = 0.000 kips
Wind horizontal load in y direction; HWyA = 0.000 kips
Total horizontal load in y direction; HyA = 0.000 kips
Moment on column base
Dead moment on column in x direction; MGxA = 1.300 kip_ft
Live moment on column in x direction; MQxA = 0.000 kip_ft
Wind moment on column in x direction; MWxA = 32.800 kip_ft
Total moment on column in x direction; MxA = 34.100 kip_ft
Dead moment on column in y direction; MGyA = 0.000 kip_ft
Live moment on column in y direction; MQyA = 0.000 kip_ft
Wind moment on column in y direction; MWyA = 0.000 kip_ft
Total moment on column in y direction; MyA = 0.000 kip_ft
Check stability against sliding
Resistance to sliding due to base friction
Hfriction = max([PGA + (FGsur + Fswt + Fsoil) A], 0 kips) tan() = 5.866 kips
Passive pressure coefficient; Kp = (1 + sin()) / (1 - sin()) = 2.464

Stability against sliding in x direction


Passive resistance of soil in x direction; Hxpas = 0.5 Kp (h2 + 2 h hsoil) B soil = 7.983 kips
Total resistance to sliding in x direction; Hxres = Hfriction + Hxpas = 13.849 kips
PASS - Resistance to sliding is greater than horizontal load in x direction
Check stability against overturning in x direction
Total overturning moment; MxOT = MxA + HxA h = 35.660 kip_ft

Restoring moment in x direction


Foundation loading; Mxsur = A (FGsur + Fswt + Fsoil) L / 2 = 48.600 kip_ft
Axial loading on column; Mxaxial = (PGA) (L / 2 - ePxA) = 1.650 kip_ft
Total restoring moment; Mxres = Mxsur + Mxaxial = 50.250 kip_ft
PASS - Restoring moment is greater than overturning moment in x direction
Calculate base reaction
Total base reaction; T = F + PA = 17.950 kips
Project Job Ref.

DeSimone Consulting Engineers Section Sheet no./rev.


3
Calc. by Date Chk'd by Date App'd by Date
EK 7/21/2015

Eccentricity of base reaction in x; eTx = (PA ePxA + MxA + HxA h) / T = 23.840 in


Eccentricity of base reaction in y; eTy = (PA ePyA + MyA + HyA h) / T = 0.000 in

Check base reaction eccentricity


abs(eTx) / L + abs(eTy) / B = 0.331
Base reaction acts outside of middle third of base
Calculate base pressures
q1 = 0.000 ksf
q2 = 0.000 ksf
q3 = 2 T / [3 B (L / 2 - abs(eTx))] = 1.968 ksf
q4 = 2 T / [3 B (L / 2 - abs(eTx))] = 1.968 ksf
Minimum base pressure; qmin = min(q1, q2, q3, q4) = 0.000 ksf
Maximum base pressure; qmax = max(q1, q2, q3, q4) = 1.968 ksf
PASS - Maximum base pressure is less than allowable bearing pressure

0.000 ksf 1.968 ksf

0.000 ksf 1.968 ksf

Load combination factors for loads


Load combination factor for dead loads; fG = 1.20
Load combination factor for live loads; fQ = 1.00
Load combination factor for wind loads; fW = 1.00

Strength reduction factors


Flexural strength reduction factor; f = 0.90
Shear strength reduction factor; s = 0.75

Ultimate axial loading on column


Ultimate axial load on column; PuA = PGA fG + PQA fQ + PWA fW = 1.860 kips
Project Job Ref.

DeSimone Consulting Engineers Section Sheet no./rev.


4
Calc. by Date Chk'd by Date App'd by Date
EK 7/21/2015

Ultimate foundation loads


Ultimate foundation load; Fu = A [(FGsur + Fswt + Fsoil) fG + FQsur fQ] = 19.440 kips

Ultimate horizontal loading on column


Ultimate horizontal load in x direction; HxuA = HGxA fG + HQxA fQ + HWxA fW = 0.520 kips
Ultimate horizontal load in y direction; HyuA = HGyA fG + HQyA fQ + HWyA fW = 0.000 kips

Ultimate moment on column


Ultimate moment on column in x direction; MxuA = MGxA fG + MQxA fQ + MWxA fW = 34.360 kip_ft
Ultimate moment on column in y direction; MyuA = MGyA fG + MQyA fQ + MWyA fW = 0.000 kip_ft

Calculate ultimate base reaction


Ultimate base reaction; Tu = Fu + PuA = 21.300 kips
Eccentricity of ultimate base reaction in x; eTxu = (PuA ePxA + MxuA + HxuA h) / Tu = 20.237 in
Eccentricity of ultimate base reaction in y; eTyu = (PuA ePyA + MyuA + HyuA h) / Tu = 0.000 in

Calculate ultimate base pressures


q1u = 0.000 ksf
q2u = 0.000 ksf
q3u = 2 Tu / [3 B (L / 2 - abs(eTxu))] = 1.802 ksf
q4u = 2 Tu / [3 B (L / 2 - abs(eTxu))] = 1.802 ksf
Minimum ultimate base pressure; qminu = min(q1u, q2u, q3u, q4u) = 0.000 ksf
Maximum ultimate base pressure; qmaxu = max(q1u, q2u, q3u, q4u) = 1.802 ksf
Calculate rate of change of base pressure in x direction
Left hand base reaction; fuL = (q1u + q2u) B / 2 = 0.000 kips/ft
Right hand base reaction; fuR = (q3u + q4u) B / 2 = 10.810 kips/ft
Length of base reaction; Lx = 3 (L / 2 - eTxu) = 47.290 in
Rate of change of base pressure; Cx = (fuR - fuL) / Lx = 2.743 kips/ft/ft
Calculate footing lengths in x direction
Left hand length; LL = L / 2 + ePxA = 3.000 ft
Right hand length; LR = L / 2 - ePxA = 3.000 ft
Calculate ultimate moments in x direction
Ultimate positive moment in x direction; Mx = Cx (LL - L + Lx)3 / 6 - Fu LL2 / (2 L) + HxuA h + MxuA = 21.721
kip_ft
Position of maximum negative moment; Lz = 3.000 ft
Ultimate negative moment in x direction; Mxneg = Cx (LL - L + Lx)3 / 6 - Fu LL2 / (2 L)
Mxneg = -14.199 kip_ft
Calculate rate of change of base pressure in y direction
Top edge base reaction; fuT = (q2u + q4u) L / 2 = 5.405 kips/ft
Bottom edge base reaction; fuB = (q1u + q3u) L / 2 = 5.405 kips/ft
Length of base reaction; Ly = B = 6.000 ft
Rate of change of base pressure; Cy = (fuB - fuT) / Ly = 0.000 kips/ft/ft
Calculate footing lengths in y direction
Top length; LT = B / 2 + ePyA = 3.000 ft
Bottom length; LB = B / 2 - ePyA = 3.000 ft
Project Job Ref.

DeSimone Consulting Engineers Section Sheet no./rev.


5
Calc. by Date Chk'd by Date App'd by Date
EK 7/21/2015

Calculate ultimate moments in y direction


Ultimate moment in y direction; My = fuT LT2 / 2 + Cy LT3 / 6 - Fu LT2 / (2 B) = 9.742 kip_ft

Material details
Compressive strength of concrete; fc = 4000 psi
Yield strength of reinforcement; fy = 60000 psi
Cover to reinforcement; cnom = 1.500 in
Concrete type; Normal weight
Concrete modification factor; = 1.00

Moment design in x direction


Reinforcement provided; 6 No. 6 bars bottom and 6 No. 6 bars top
Depth of tension reinforcement; dx = h - cnom - xB / 2 = 34.125 in
Area of tension reinforcement provided; As_xB_prov = NxB xB2 / 4 = 2.651 in2
Area of compression reinforcement provided; As_xT_prov = NxT xT2 / 4 = 2.651 in2
Minimum area of reinforcement; As_x_min = 0.0018 h B = 4.666 in2
Spacing of reinforcement; sxB_prov = (B - 2 cnom) / max(NxB - 1, 1) = 13.800 in
Maximum spacing of reinforcement; smax = min(3 h, 18in) = 18.000 in
PASS - Reinforcement provided exceeds minimum reinforcement required
Depth of compression block; ax = As_xB_prov fy / (0.85 fc B) = 0.65 in
Neutral axis factor; 1 = 0.85
Depth to the neutral axis; cna_x = ax / 1 = 0.76 in
Strain in reinforcement; t_x = 0.003 (dx - cna_x) / cna_x = 0.13094
PASS - The section has adequate ductility (cl. 10.3.5)
Nominal moment strength required; Mnx = abs(Mx) / f = 24.134 kip_ft
Moment capacity of base; Mcapx = As_xB_prov fy [dx - (As_xB_prov fy / (1.7 fc B))]
Mcapx = 447.974 kip_ft
PASS - Moment capacity of base exceeds nominal moment strength required
Negative moment design in x direction
Reinforcement provided; 6 No. 6 bars top and 6 No. 6 bars bottom
Depth of tension reinforcement; dx = h - cnom - xT / 2 = 34.125 in
Area of tension reinforcement provided; As_xT_prov = NxT xT2 / 4 = 2.651 in2
Area of compression reinforcement provided; As_xB_prov = NxB xB2 / 4 = 2.651 in2
Minimum area of reinforcement; As_x_min = 0.0018 h B = 4.666 in2
Spacing of reinforcement; sxT_prov = (B - 2 cnom) / max(NxT - 1, 1) = 13.800 in
Maximum spacing of reinforcement; smax = min(3 h, 18in) = 18.000 in
PASS - Reinforcement provided exceeds minimum reinforcement required
Depth of compression block; ax = As_xT_prov fy / (0.85 fc B) = 0.65 in
Neutral axis factor; 1 = 0.85
Depth to the neutral axis; cna_x = ax / 1 = 0.76 in
Strain in reinforcement; t_x = 0.003 (dx - cna_x) / cna_x = 0.13094
PASS - The section has adequate ductility (cl. 10.3.5)
Nominal moment strength required; Mnxneg = abs(Mxneg) / f = 15.777 kip_ft
Moment capacity of base; Mcapxneg = As_xT_prov fy [dx - (As_xT_prov fy / (1.7 fc B))]
Project Job Ref.

DeSimone Consulting Engineers Section Sheet no./rev.


6
Calc. by Date Chk'd by Date App'd by Date
EK 7/21/2015

Mcapxneg = 447.974 kip_ft


PASS - Moment capacity of base exceeds nominal moment strength required
Moment design in y direction
Reinforcement provided; 6 No. 6 bars bottom and 6 No. 6 bars top
Depth of tension reinforcement; dy = h - cnom - xB - yB / 2 = 33.375 in
Area of tension reinforcement provided; As_yB_prov = NyB yB2 / 4 = 2.651 in2
Area of compression reinforcement provided; As_yT_prov = NyT yT2 / 4 = 2.651 in2
Minimum area of reinforcement; As_y_min = 0.0018 h L = 4.666 in2
Spacing of reinforcement; syB_prov = (L - 2 cnom) / max(NyB - 1, 1) = 13.800 in
Maximum spacing of reinforcement; smax = min(3 h, 18in) = 18.000 in
PASS - Reinforcement provided exceeds minimum reinforcement required
Depth of compression block; ay = As_yB_prov fy / (0.85 fc L) = 0.65 in
Neutral axis factor; 1 = 0.85
Depth to the neutral axis; cna_y = ay / 1 = 0.76 in
Strain in reinforcement; t_y = 0.003 (dy - cna_y) / cna_y = 0.12800
PASS - The section has adequate ductility (cl. 10.3.5)
Nominal moment strength required; Mny = abs(My) / f = 10.825 kip_ft
Moment capacity of base; Mcapy = As_yB_prov fy [dy - (As_yB_prov fy / (1.7 fc L))]
Mcapy = 438.033 kip_ft
PASS - Moment capacity of base exceeds nominal moment strength required
Calculate ultimate punching shear force at perimeter of d / 2 from face of column
Ultimate pressure for punching shear; qpuA = q4u-[(L/2-ePxA-lA/2-d/2)+(lA+2d/2)/2]Cx/B+[(B/2-ePyA-bA/2-
d/2)+(bA+2d/2)/2]Cy/L
qpuA = 0.430 ksf
Average effective depth of reinforcement; d = (dx + dy) / 2 = 33.750 in
Area loaded for punching shear at column; ApA = (lA+2d/2)(bA+2d/2) = 18.598 ft2
Length of punching shear perimeter; upA = 2(lA+2d/2)+2(bA+2d/2) = 17.250 ft
Ultimate shear force at shear perimeter; VpuA = PuA + (Fu / A - qpuA) ApA = 3.903 kips

Punching shear stresses at perimeter of d / 2 from face of column


Nominal shear strength; VnpuA = VpuA / s = 5.204 kips
Ratio of column long side to short side; A = max(lA, bA) / min(lA, bA) = 1.000
Column constant for interior column; sA = 40
Concrete shear strength; Vc_p_i = (2 + 4 / A) (fc 1 psi) upA d = 2651.095 kips
Vc_p_ii = (sA d / upA + 2) (fc 1 psi) upA d = 3765.324 kips
Vc_p_iii = 4 (fc 1 psi) upA d = 1767.397 kips
Vc_p = min(Vc_p_i, Vc_p_ii, Vc_p_iii) = 1767.397 kips
PASS - Nominal shear strength is less than concrete shear strength
Project Job Ref.

DeSimone Consulting Engineers Section Sheet no./rev.


7
Calc. by Date Chk'd by Date App'd by Date
EK 7/21/2015

6 No. 6 bars btm (14'' c/c)


6 No. 6 bars top (14'' c/c)

6 No. 6 bars btm (14'' c/c), 6 No. 6 bars top (14'' c/c)

Two way shear at d / 2 from column face

S-ar putea să vă placă și