Documente Academic
Documente Profesional
Documente Cultură
Platform Devices
(MACH 4000 and PowerMICE)
CP3e_2_HW.926 2-1
CP3e_2_HW.926 2-2
Device
Fan module
Terminal blocks for indicator contact
Terminal cable RS-232
Accessories:
Power supply due to your choice to use an internal one or
separate ones in the power supply chassis
One power supply can be installed in the chassis of MACH
4000 with access from the rear side.
3 power supplies are offered with a power consumption of
300 W at 115/230 VAC, 24 VDC and 48 VDC. Therefore
MACH 4000 is delivered without power supply.
Power supply must be ordered separately!
Slot 3
Slot 1 Slot 4
Slot 2
fixed module 5
fixed module 6
CP3e_2_HW.926 2-3
No socket No socket
CP3e_2_HW.926 2-4
* Please note: despite the fact that L2P, L3E and L3P
are related to the firmware it is not possible to upgrade
lower level devices to a higher level, due to HW
differences.
The functionality of the firmware levels are shown in the
appendix.
Power Supply Chassis M4-POWER
External power supply
3 sockets for power supply modules (M4-P-), hot-swappable
No fans
24 VDC out
rear
front
M4-POWER VAC
CP3e_2_HW.926 2-5
MACH 4000 offers the possibility to install one power supply with Notes:
access from rear.
Alternatively power supplies can be installed in a separate
chassis M4-Power with access from front for exchange.
Connection of MACH 4000 is done at the back with special
power cords. Power and voltage like internal PSs.
The Power Supply Chassis M4-POWER is necessary for power
supply redundancy. Either the power supply installed in MACH
4000 can be protected by redundancy using M4-POWER or
MACH 4000 can be operated exclusively using M4-POWER.
Attention: Operation of MACH 4000 with other power supplies
than the defined internal and external ones is not permitted!
24 VDC, 48VDC, 110-240VDC supported by corresponding
internal power supplies:
M4-S-AC/DC 110-240VAC / 120-350VDC
M4-S DC 24V
M4-S DC 48V
and external power supplies within M4-POWER:
M4-P AC/DC 110-240VAC / 120-350VDC
M4-P DC 24V 943 876-001
M4-P DC 48V 943 877-001
with fail-over technology.
MICE Modular Industrial Communication Equipment
Modular design:
Gigabit socket (4 GE ports)
+ Head module
+ 4 sockets for up to 16 ports
+ Backplane extension board for up to 24 FE ports
Switch/router in backpanel
Head module
Voltage in: 24 VDC (18-32 VDC) optional redundant PS
2 indicator contacts
RS232 interface
USB port
DIP switches
CP3e_2_HW.926 2-6
ACL 100 with max. 10 rules each 100 with max. 10 rules each
L2/L3/L4 Paket filtering 20 per port 100 per port
L3 Multicast
PIM-SM no later
PIM-DM no YES 512 Streams
IGMP V1/2/3 no YES 512 Streams
DVMRP no YES 512 Streams
CP3e_2_HW.926 2-7
CP3e_2_HW.926 2-8
Notes:
Compatibility of Modules and SFPs with Devices
MACH 4002 M4-8TP M4-FAST 8TP-PoE M4-FAST 8SFP M4-GIGA 8SFP
48+4G x x x -
24G x x x *) x
24G+3X x x x *) x
48G x x x *) x
48G+3X x x x *) x
Operation in SFP
MACH 4002 Fast-MM Fast-SM Fast-LH Giga-SX Giga-LX Giga-LH
48+4G Combo - - - x x x
48+4G M4-FAST x x x - - -
24G and 48G Combo x x x x x x
24G and 48G M4-GIGA x x x x x x
CP3e_2_HW.926 2-9
CP3e_2_HW.926 2-10
50/125m
Multimode 850 nm LC 400 2 66 m
50/125m
Multimode 500 2 100 m
50/125m
Multimode 2000 2 300 m
9/125m
M-XFP ZR/LC Singlemode
1550 nm LC --- 40 km 80 km
943 9xx-001
CP3e_2_HW.926 2-11
XFPs are slightly larger than SFPs. The XFPs are hot- Notes:
swappable. They offer diagnosis by measuring temperature
as well as optical power in and out in mW.
Please note: ER and ZR XFPs need up to 45 s (warm-up)
after installing them under power. All XFPs need about 5 s
after a warm reset.
LED Display
P P1 P2 P3 P4
RM RELAY1 RELAY2 AIR RUN
L/D FDX 1000 AUTONEG TP/FO
RING PORT STAND-BY LED TEST 2 1
Rear View
CP3e_2_HW.926 2-13
MACH 4000 and Power Supply Chassis are connected with Notes:
special cables, one delivered with each external power supply.
Software Packet L3E for PowerMICE and MACH 4000
Category Feature/function Release M3000
Routing IPv4 UCs, hardware based 1 x
Routing CIDR 1 x
Routing ARP entries: 2048 1 x
Routing Proxy ARP 1.5.0
Software L3 Enhanced
Please note that the listed functions are additionally in L3E Notes:
to the already contained functions of L2P.
With DSCP Marking the first router analyses the packet and
changes its DSCP/TOS field, all following routers evaluate
the field only.
Per ACLs packets can be assigned to a queue, and as of
SW 2.0.0 also the tags are changed correspondingly.
ACLs currently have effect on incoming traffic only.
Please note, that at all ACLs the last rule Deny all is
invisible already implicit available.
Dont cut the branch you are sitting on!
To avoid misapplication VLAN interfaces support only
Independent VLAN Learning, but not Shared VLAN
Learning.
Software Packet L3P for PowerMICE and MACH 4000
Category Feature/function Release
VLAN Protocol-based VLANs (IP/non-IP) 1
Routing 128 VLAN interfaces, phys. router IFs 1
Routing Dynamic: OSPF 1
Software L3 Professional
CP3e_2_HW.926 2-15
Protocol-based VLANs
OSPF
MC routing