Sunteți pe pagina 1din 11

HIQUAD

VS
HIMA X
ISMAIL SHAHID
CHARACTERISTICS
HIQUAD HIMAX
Maximum fault tolerance Non-stop operation
Scalable redundancy Maximum performance
Largest selection of I/O modules Configuration flexibility for life
A wide range of mechanical concepts
APPROVED UP TO
HIQUAD HIMAX
SIL3 SIL3 & SIL 4(in RAIL industry)
SUITABLE FOR
HIQUAD HIMAX
Small and medium-sized applications Medium-sized and large applications
Centralized and distributed installations Process industry
Process industry Rail industry
ARCHITECTURE
HIQUAD HIMAX
XMR architecture is designed to increase availability.
The H41q model is particularly compact
Every HIMax module can be operated in QMR (Quadruple
and supports up to 208 inputs and outputs. Modular Redundant), TMR (Triple Modular Redundant),
Dual or Single modes, and programming time is the same for
The H51q model is modular and can be all modes.
extended at any time up to several Complete single-fault tolerance applies from the dual
structure upwards: in the event of a fault you can replace the
thousand inputs and outputs. faulty module online at any time and without restrictions.
Every I/O module can be operated using one or more CPUs.
As many as 4 CPU modules can be used in one system, and
up to 3 I/O modules can act on the same sensor or actuator at
the same time.
In terms of availability , XMR can suffer a 4-3-2-1
degradation and still maintain the SIL 3 safety level.
HIQUAD
HIMAX
SOFTWARE
HIQUAD HIMAX
ELOPE II SILworX (X-OPC Server)
X-OTS (upto 10 controller per PC)
PADT The HIMax X-OTS simulation supplements traditional
operator training systems with a safety section. It
enables you to thoroughly test application software
before commissioning. Ultimately, you begin operation
earlier and bring your plant online sooner.

Note: ELOP II users will be comfortable with SILworX because the operation and features
of the functional block diagram language editors are derived from ELOP II.
NETWORKING AND COMMUNICATIONS

HIQUAD HIMAX
OPC A&E OPC DA and OPC A&E
MODBUS TCP Master & Slave
OPC DAP
MODBUS Master & Slave RS485
ROFIBUS DP
PROFIBUS-DP Master & Slave
MODBUS RTU PROFINET
MODBUS TCP FOUNDATION fieldbus H1(together with
FF-SIS protocol)
OPC DA
Send & Receive TCP
MODBUS TC HART protocol
Siemens 3964R ComUserTask,
programmable protocols
NETWORKING AND COMMUNICATIONS

HIQUAD HIMAX
Various options for remote operation, with
distributed control via
HIMA safe Ethernet
PROFINET/PROFIBUS with PROFIsafe
FOUNDATION fieldbus safety FF-SIS H1(as
soon as available)
Up to 20 COM modules per system, each with two
fieldbus connectors (9-pin D-sub) and four
Ethernet ports (RJ-45),running up to 4 protocols
per COM module simultaneously.
Full integration with HIMA HIQuad and
HIMatrix systems.
THE SYSTEM COMPONENTS
HIMAX
High-performance RISK processors for fast
calculations
Processing of all field signals in the I/O
modules, which means that analog values are
processed at the same time as digital values.
Implementation of a system bus with a 1
GBit/s transmission speed.
Multitasking capabilities: 32 user programs
can be run simultaneously,with each program
having its own cycle time.
Three available rack sizes: 10, 15 and 18
slots