Sunteți pe pagina 1din 6

Objective Marking Form

National Skills Competition B


Jakarta 2013
Trade : Electrical Installation
Competitor Name : Competitor No :

Sub Criterion : Module B - Safety


Aspect Max Requirement
Result or Mark
Aspect of Criterion - Description or Nominal
ID Mark Actual Value Awarded
Size

1 3 All Health and Safety requirements met at all times

1 mark deducted for each breach of Safety (Up to


maximum allocation)

PPE used as describe in the health and safety


regulation

No pieces of pipe and cable, lying down on the


floor. The competitor must keep these in a safe
area or in the bin box

3 Maximum Mark for Sub Criterion Mark Awarded

Jakarta,

Signatures confirming the accuracy of this result

EXPERT 1 EXPERT 2 EXPERT 3


Objective Marking Form
National Skills Competition B
Jakarta 2013
Trade : Electrical Installation

Competitor Name : Competitor No :

Sub Criterion : Module B - Commisioning

Aspect Max
Requirement
Result or Mark
Aspect of Criterion - Description or Nominal
Actual Value Awarded
Size
ID Mark

1 5 Comissioning OK

Test report OK, Safe to power up, Powered on

First attempt OK, No further attempt needed: 4


point

Second attempt OK, No further attempt


needed: 2 poin

More than two attempt needed: 1 poin

5 Maximum Mark for Sub Criterion Mark Awarded

Jakarta,

Signatures confirming the accuracy of this result

EXPERT 1 EXPERT 2 EXPERT 3


Objective Marking Form
National Skills Competition B
Jakarta 2013
Trade : Electrical Installation

Competitor Name : Competitor No :

Sub Criterion : Module B - Function


Aspect Max Requirement Result or Mark
Aspect of Criterion - Description
ID Mark or Nominal Actual Value Awarded

1 1 Motor rotates in one direction (when push S3)

0.5 Left contactor hold in circuit operates correctly

Motor rotates in the oposite direction (when push


1
S5)

0.5 Right contactor hold in circuit operates correctly

Interlock function correctly operates on control


1
station

0.5 Stop (when push S1)

0.5 Emergency Stop (when push S0)

1 Overload operates correctly

1 Indicators (0.5 each OK)

7 Maximum Mark for Sub Criterion Mark Awarded

Jakarta,

Signatures confirming the accuracy of this result

EXPERT 1 EXPERT 2 EXPERT 3


Objective Marking Form
National Skills Competition B
Jakarta 2013
Trade : Electrical Installation

Competitor Name : Competitor No :

Sub Criterion : Module B - Measurements


Aspect Max Requirement Result or Mark
Aspect of Criterion - Description
ID Mark or Nominal Actual Value Awarded
Item 1: Equipment is level/plumb and
1 0.5
dimensionally correct to the datumline
The marking team must identify the items that are
to be inspected by lottery.

Ref TD: Measurements <=500mm +/- 2mm

Ref TD: Measurements >500mm +/- 3mm

Item 2: Equipment is level/plumb and


0.5 dimensionally correct to the reference line
Item 3: Equipment is level/plumb and
0.5 dimensionally correct to the reference line
Item 4: Equipment is level/plumb and
0.5 dimensionally correct to the reference line
Steel conduit level/plumb and dimensionally
1 correct with all bends
Steel tray level/plumb and dimensionally correct
1 with all bends correctly set with reference to the
datum line
PVC conduit level/plumb and dimensionally
1 correct with all bends correctly set with reference
to the datum line

5 Maximum Mark for Sub Criterion Mark Awarded

Jakarta,

Signatures confirming the accuracy of this result

EXPERT 1 EXPERT 2 EXPERT 3


Objective Marking Form
National Skills Competition B
Jakarta 2013
Trade : Electrical Installation

Competitor Name : Competitor No :

Sub Criterion : Module B - Installation of Equipment & Wire Ways


Aspect Max Requirement Result or Mark
Aspect of Criterion - Description
ID Mark or Nominal Actual Value Awarded

All items of equipment and wire ways complete,


1 3
undamaged andsecurely fixed

Marks deducted for additional materials supplied


to the competitor due to their misuse or damage:

1 mark deducted for each meter of containment,


accessory or piece of equipment

1 mark deducted for each item not complete or


damaged or notsecurely fixed or for additional
materials supplied

Materials and equipment placed in the correct


1 location (lamps,pushbuttons and colors) according
tocompetition drawing

Materials, equipment, wire ways and accessories


1 assembled as per competition instructions and
manufactures instruction

5 Maximum Mark for Sub Criterion Mark Awarded

Jakarta,

Signatures confirming the accuracy of this result

EXPERT 1 EXPERT 2 EXPERT 3


Objective Marking Form
National Skills Competition B
Jakarta 2013
Trade : Electrical Installation

Competitor Name : Competitor No :

Sub Criterion : Module B - Wiring and Termination


Aspect Max Requirement Result or Mark
Aspect of Criterion - Description
ID Mark or Nominal Actual Value Awarded
Item 1: Equipment or accessory terminals
1 1
correctly terminated at item 1
The marking team must identify the items that are
to be inspected by lottery.
Terminations must have no copper visible at the
termination when viewed at 90 degrees.
Terminations must have no plastic inside the
termination and be a good electrical and
mechanical joint.
Item 2: Equipment or accessory terminals
1
correctly terminated at item 2
Item 3: Equipment or accessory terminals
1
correctly terminated at item 3

A1: Terminals correctly terminated at distribution


2
board

0 mistakes = 3

1 mistakes = 2

2 mistakes = 1

3 mistakes

5 Maximum Mark for Sub Criterion Mark Awarded

Jakarta,

Signatures confirming the accuracy of this result

EXPERT 1 EXPERT 2 EXPERT 3