Documente Academic
Documente Profesional
Documente Cultură
ESCALATORS & MOVING WALKS - We reserve the right to change designs and specications for the product development without prior notice.
Copyright HYUNDAI ELEVATOR CO., LTD. All rights reserved. Printed in Korea.
C-EMW-E1413/2012.11/Rev.14
CONTENTS
Hyundai moving walks are available in horizontal, inclined design Single Parallel
within 12 degree or in combined design and are widely applicable
to various buildings and facilities such as supermarkets, subways
and railroad stations, sports stadiums, department stores, and so
on. They offer a new dimension of convenience, satisfaction and
excitement for the customers and passengers.
Criss Cross
3. Step Color
7. Floor Marking
Check Check
3. Step Color Check 4. Under Handrail Lighting 5. SafetyBrush
1. Handrail Color
6. Muti-Post
Black Gray BT type can be applied Promoting passenger safety
5. Safety Brush by gently guiding
(Standard)
passengers away from skirt.
8. Exterior Cladding
Check
6. Muti-Post Check 7. Floor Marking
4. Under Handrail Lighting
7. Floor Marking
8. Exterior Cladding
(By Others)
ASP - S01 ASP - A03 ASP - A02 ASP - A01
Note : Applicable prices will vary per selected optional features/designs. Stainless Steel / Painted Steel
Escalator
Model
New World Class H-series
BT Handrail
BB Handrail
Deck
Type 800 1000 1200 800 1000 1200 800 1000 1200
Transport Capacity
3600 4800 6000 3600 4800 6000 3600 4800 6000
(persons/hr)
Step Width(mm) 588/606 807 1008 588 807 1008 602 801 1001 Design Type
Skirt Distance(mm) 594/612 813 1014 594 813 1014 608 807 1007 Type BT BB
EscalatorWidth(mm) 1130/1150 1350 1550 1330 1549 1750 1300 1500 1700
Handrail Center
837/855 1056 1257 986 1205 1406 965 1164 1364
Distance(mm) Designs
Truss Width(mm) 1080/1100 1300 1500 1280 1499 1700 1250 1450 1650
NEW
New World Class O O O
Inclination 0/12
Design Specication
Power Supply AC 3PH, 380V, 50/60HZ
Name of Part BT BB
Lighting Power Supply AC 1PH, 220V, 50/60HZ
Interior Panel Transparent Tempered Glass Hairline-Finished Stainless Steel
Rated Speed 30m/min
Deck Hairline-Finished Stainless Steel
Control System AC1(Optional: VVVF Control) Balustrade
Skirt Panel Hairline-Finished Stainless Steel
Operation System Key Switch Reversible Operation(Optional : AutomaticOperation)
Handrail Black (Optional : 9 page)
Transport Capacity
4800 6000
(persons/hr) Step Aluminum Die Casting
Step
Skirt Distance(mm) 800 1000 Demarcation Yellow molded safety inserts on 3 sides
Escalator Width(mm) 1350 1550 Comb Yellow Synthetic Resin (Optional : Aluminum)
Handrail Center Distance(mm) 1057 1257 Floor Plate Stainless steel plate with anti-slip grooves
Skirt Switch
Stop the escalator/moving walk automatically,
if a foreign object such as part of a shoe gets
caught between a step/pallet and skirt.
Comb Plate
Switch
Handrail Guard Switch Stop the escalator/moving
Stop the escalator/moving walk automatically, if walk, if a foreign object
a object becomes wedged between the handrail becomes wedged between
and the handrail guard. the comb and steps/pallets.
C 1.732H (note 2) B
2230 1.428H (note 3) 2650
D (note 4) Min. 2500
1910 (note 4) Min. 2500
50 50
Floor Opening Enclosures (By Others)
Floor Opening Enclosures (By Others)
1070
793
(By Others)
1070
R1
793
Working (By Others) R1
Working
Head ROOM
Min. 2300
Point
HEAD ROOM
Point
908
Min. 2300
968
Wiring Inlet
950
Wiring Inlet
950
(note 2) F (By Others) (note 4) Min. 2500 (By Others)
1490 (note 3) 2522
R4
(note 4) Min. 2500
H = Rise
E
H = Rise
R3 Intermediate
937
Support
937
30 (By Others)
35
Min. 1170
Min. 1170
1070
1070
R2 Working
Point R2 Working
Point
L3 L1
G 2358
J
Min. 4500
L2
Model Qty of
B C D E F G J
(Inclination) Flat Step Notes : 1. AA = 1.428 H + 2650 + 2230 + 100
Notes : 1. AA = 1.732 H + B + C + 100 When maximum floor opening exceeds AA=14,230mm, intermediate support(s) are
NW-BT 2 2560 2230 1820 1490 2511 2118 4500
When maximum floor opening exceeds AA=15,300mm, intermediate required. Consult Hyundai for the intermediate support data.
support(s) are required. Consult Hyundai for the intermediate support data. NW-BB 3 2967 2637 2227 1897 2918 2525 4910
2. Qty of flat step : 2
2. In case inverter system is applied, dimension B, F shall increase 500mm. 3. In case inverter system is applied, dimension 2650, 2522 shall increase 500mm.
(800Type, 1000Type : increase 700mm) (800Type, 1000Type : increase 700mm)
3. When vertical rise is over 6000mm, 3-flat step is applied. Section Dimensions (Unit : mm)
4. Dimension between the end of handrail to the wall ; Min. 2500mm
4. Dimension between the end of handrail to the wall ; Min. 2500mm 5. Dimensions are based on EN115.
5. Dimensions are based on EN115. Type NW800 NW1000 NW1200
6. Vertical Rise H 6m.
6. Vertical Rise H 10.5m. W1 612 813 1014
W2 855 1056 1257
W3 1150 1350 1550
W4 1100 1300 1500
W5 1250 1450 1650
w3
Typical Concrete Support Reactions (Unit : kg) Typical Concrete Support w2
Section Dimensions (Unit : mm)
Min. 200 Type NW800 Min. 200 w1 Type NW800 NW1000 NW1200
Top of Finish Floor Top of Finish Floor
(By Others) Rise H (mm) H 6000 5000 H 7600 7600 H 10500 (By Others) Floor Opening W1 612 813 1014
11(Shim)
Enclosure
11 (Shim)
Number of - 1 1 2
90
W2 855 1056 1257
90
(By Others)
150
Intermediate Support
150
935
R1 0.65H + 2300 0.36L1 + 900 0.36L1 + 1100 0.36L1 + 1100 W3 1150 1350 1550
R2 0.65H + 1600 0.36L2 + 300 0.36L2 + 400 0.36L2 + 450 W4 1100 1300 1500
L20020020 L20020020
R3 - 0.36(L1 + L2) + 450 0.36(L1 + L2) + 700 0.36(L2 + L3) + 250
W5 1250 1450 1650
R4 - - - 0.36(L1 + L3) + 600
50 50 50 50
w3 Type NW1000
w2 Rise H (mm) H 6000 5000 H 7600 7600 H 10500 Reactions (Unit : kg)
w1 Number of - 1 1 2 w4 Vertical Rise Reactions
Intermediate Support H(mm) ML800 ML1000 ML1200
Typical Steel Support Floor Opening
Enclosure
Typical Steel Support W5
R1 0.72H + 2600 0.41L1 + 900 0.41L1 + 1100 0.41L1 + 1100 0.59H +
Min. 200 (By Others) Min. 200 R1 0.51H + 2400 0.66H + 3000
Top of Finish Floor R2 0.72H + 1900 0.41L2 + 300 0.41L2 + 400 0.41L2 + 450 Top of Finish Floor 3000 2700
935
2100
11(Shim)
90
90
150
Type NW1200 Note : When vertical rise is over 6000mm or AA is over 14230mm, consult
Hyundai for reactions data.
Rise H (mm) H 6000 5000 H 7600 7600 H 10500
L20020020 L20020020
Number of
50 50 - 1 1 2 50 50
Intermediate Support
Reinforced Plate
w4 R1 0.78H + 2900 0.45L1 + 1000 0.45L1 + 1250 0.45L1 + 1250 Reinforced Plate
(By Others) (By Others)
w5 R2 0.78H + 2200 0.45L2 + 300 0.45L2 + 450 0.45L2 + 500
R3 - 0.45(L1 + L2) + 500 0.45(L1 + L2) + 750 0.45(L2 + L3) + 300
R4 - - - 0.45(L1 + L3) + 650
14 HYUNDAI ELEVATOR Escalators & Moving Walks 15
Standard Layout & Dimensions Standard Layout & Dimensions
H-SERIES ESCALATORS H-SERIES ESCALATORS
HA-BT, HA-BB HD-BT, HD-BB
937
"A"
Floor Opening Enclosures (By Others)
937
1280
Head Room Working
Soffit Guard Point
Min. 2300
843
(By Others)
1400
Working R1 R1
Point "B"
Min. 2300
Wiring Inlet
0
100
(By Others)
(note 5) H = Rise
(note 2) Min. 2500 2150 (note 3) 4342 Intermediate Support
793
(By Other)
Min. 290
R4
908
"B"
0
110 Wiring Inlet
H = Rise
2241
(By Others)
(note 1)
Intermediate
R3 Support
937
"A" "B"
937
(By Others)
30
30
Min. 1400
1300
1210
Working
1200
R2 Working Point R3 R4 R5
Point
L3 L1 R2 Min. 5100
3065
L 2 (Max.12000) L 3 (Max.12000) L 4 (Max.12000) L 1 (Max.12000)
Min. 5700
L2
Notes : 1. N : Number of intermediate supports
Max. distance between intermediate supports is 12000mm
AA = 1.732 H + 4014 + 2884 + 100
Notes : 1. N : Number of intermediate supports
2. Dimension between the end of handrail to the wall : Min. 2500mm
Max. distance between intermediate supports is 12000mm
AA = 1.732 H + 4464 + 4342 + 100 3. 4014 is a dimension of inverter applied system.
2. Dimension between the end of handrail to the wall : Min. 2500mm 4. Dimensions are based on EN115.
3. 4464, 4342 are dimensions of inverter applied system. 5. Vertical Rise 15m < H 20m.
(800Type : 4664, 4542)
4. If EN115 is applied, consult Hyundai.
5. Vertical Rise 10.5m < H 15m.
w5
w5
Typical Concrete Support w3 Section Dimensions (Unit : mm) Typical Concrete Support w3 Section Dimensions (Unit : mm)
11 (Shim)
(By Others)
11(Shim)
Min. 210
W2 986 1205 1406 W2 965 1164
Min. 210
1364
936
90
90
50 50 50 50
w4
w 4 + 200
Reactions (Unit : kg)
Typical Steel Support Typical Steel Support
Type HA800 HA1000 HA1200 Min. 200
Min. 200
Top of Finish Floor Top of Finish Floor
(By Others) Vertical Rise (By Others)
10500 H 15000
11 (Shim)
H (mm)
11(Shim)
Min. 210
Min. 210
90
90
"A" 660
940
660
937
937
"A"
"A"
Head Room
1100
Working
Min. 2300
719
Point "B" "B" "B"
1100
1200
1200
1100
1129 Working Working
790
Height (H)
R1 R2 Point Point R1
"B"
Wiring Inlet Intermediate Support Beam
719
R3 R4~R(n-1) Rn
(By Others) Wiring Inlet (By Others)
"A" Intermediate Support (note 1) Min. 4000
940
(By Others)
1200
1100
Working
Point
L 2 (Max.10000) L 3 (Max.10000) L 1 (Max.10000) Notes : 1. In case inverter system is applied, dim. 2190, 4000 shall increase 500mm.
(1000Type : increase 700mm)
2. Dimension between the end of handrail to the wall : Min. 2500mm
Notes : 1. In case inverter system is applied, dim. 3300 shall increase 500mm. 3. Dimensions are based on EN115.
(1000Type : increase 700mm)
2. Dimension between the end of handrail to the wall : Min. 2500mm
3. Dimensions are based on EN115.
Reactions (L1 ~ Ln : m)
Reactions (L1 ~ Ln Unit : m)
Inclination Floor Opening AA = (L) Type R1 (kg) R2 (kg) R3 (kg) R4 (kg) Rn (kg)
NPM1000 NPM1200
Incli- Vertical intermediate
Number of
nation H Rise
(mm) Support 0 9110~80000
NPM1000 400 L1 + 1300 400 L2 + 400 330 (L2 + L3) 320 (L3 + L4) 330 (Ln -1 + Ln)
R1 (kg) R2 (kg) R3 (kg) R4 (kg) R5 (kg) R1 (kg) R2 (kg) R3 (kg) R4 (kg) R5 (kg)
NPM1200 420 L1 + 1700 420 L2 + 700 350 (L2 + L3) 340 (L3 + L4) 350 (Ln -1+ Ln)
10 1430 1 453 L1 + 700 439 L2 + 45 449 (L1 + L2) - - 503 L1 + 780 487 L2 + 50 498 (L1 + L2) - -
& ~ 2 453 L1 + 700 439 L2 + 45 440 (L2 + L3) 449 (L1 + L3) - 503 L1 + 780 487 L2 + 50 489 (L2 + L3) 498 (L1 + L3) -
12 7000 3 453 L1 + 700 439 L2 + 45 440 (L2 + L3) 440 (L3 + L4) 449 (L1 + L4) 503 L1 + 780 487 L2 + 50 489 (L2 + L3) 489 (L3 + L4) 498 (L1+ L4)
w5
Typical Concrete Support w3 Section Dimensions (Unit : mm)
w5 w2
Typical Concrete Support Section Dimensions (Unit : mm) Min. 200 Type NPM1000 NPM1200
w3
Top of Finish Floor w1
(By Others)
Min. 200 W1 814 1014
Type NPM1000 NPM1200
11(Shim)
Top of Finish Floor w2
Min. 150
(By Others) W2 1057 1257
90
w1 W1 814 1014
11(Shim)
W3 1350 1550
Min. 150
W2 1057 1257
90
W4 1300 1500
W3 1350 1550 L20020020
Base Plate W5 1500 1700
W4 1300 1500 15019
L20020020
Base Plate W5 1500 1700 w4
50 50
15019 w5
50 50
Min. 150
Min. 150
90
90
L20020020 L20020020
50 50 50 50
Reinforced Plate
Reinforced Plate
(By Others)
(By Others)
Note : Consult Hyundai if the isolation pad is applied. Note : Consult Hyundai if the isolation pad is applied.
By Others
WORKS TO BE DONE BY OTHER CONTRACTORS 2. Electrical Work
1. Permanent electric service, as hereafter specied to the 4. Any electric circuits and outlets for special use as required.
The following list explains the work which is necessary for a normal escalator installation, but is not done by the escalator contractor. controller in the machine compartment, and wiring for 5. Provision of a grounding electrode to the escalator truss if
Therefore this work must be provided by others. lighting. escalator is isolated from building structure.
2. Temporary power as required for construction, testing and 6. Suitable connections from the power mains to each
adjusting of the same characteristics as the permanent controller, including necessary circuit breakers and fused
power supply. mainline disconnect switches.
3. Provision of a light and single phase lighting circuit run 7. Power feeders to the controller of each escalator.
to combination receptacle and convenience outlets to be 8. Provide emergency lights and other interior illuminations as
1. Building Work located at the top and bottom of the escalator. required.
1.Necessary properly framed openings in the oors, necessary 4.Arrangement for proper ventilation of the machine
supports for the truss per the manufacturer's drawings and compartment and controller space. Electric Power Requirements (By Others)
information. Necessary enclosure, wellway railings, bafes 5.Finished ooring and its base over the escalator contractor's
and barricades around the wellway as required. Coordination oor support. Motor Power Supply Power Supply Voltage C.B. Rated Power Feeder (mm2) (from power room to escalator controller)
Type
(kW) Capacity (kVA) (AC-3Phase) Current (A) 20m 40m 60m 80m 100m 120m
with the escalator contractor for the location and installation 6.Provision and maintenance of temporary enclosures or other
50 10 16 25 35 35 35
of the steel member required for truss attachment prior to the protection from open wellways during the time the escalator 5.5 12 30 6 6 10 16 16 16
pouring of the concrete supports. is being installed. 30 6 6 6 10 10 (L116
~ Ln : m)
60 10 25 35 35 50 50
2.Covering for the exterior of the escalator from the edges 7.Painting and nishing of all material other than that described 7.5 14 40 6 6 10 16 16 25
of the decks including covering for the truss and soft. in this specication. 30 6 6 6 10 16 16
75 16 25 35 35 50 70
The materials used will be re resistant as required by the 8.Any governmentally required safety provisions not directly 5.52/11 19 50 6 10 16 25 25 25
applying code and will weigh not more than 25 kgs/m (5 2
involved in the escalator installation. 40 6 6 10 16 16 25
125 25 35 50 95 95 120
lbs/ft2) for Millennium escalator and 50 kgs/m2 (10 lbs/ft2) for 9.Soft guards at the intersecting angle of the outside deck 7.52 27 75 6 16 25 25 35 35
Modular escalator and H-series escalator. and ceiling. 60 6 10 16 25 25 25
New World Class 175 35 50 50 120 120 150
3.Floor openings for escalators shall be protected against the 10.Transparent barriers between adjacent parallel escalators 7.53 40 100 10 25 35 35 50 50
passage of ame, heat, and/or smoke in accordance with the and on the outboard side of single escalators. 100 6 16 25 25 35 35
225 35 95 120 120 185 185
provisions of the building code. 7.54 52 150 16 25 35 50 70 95
125 10 25 25 35 35 50
300 50 95 120 185 185 240
7.55 65 175 16 35 50 70 95 95
150 16 25 35 35 50 70
Openings and Suspension Holes For Installation (By Others) 350 50 120 150 185 240 300
7.56 78 200 25 35 50 95 95 120
175 16 25 35 50 70 95
Floor Openings-Side view 100 16 25 35 50 50 95
11 19 50 6 10 16 25 25 25
40 6 6 10 16 16 25
125 25 35 50 70 95 120
16 25 60 6 16 25 25 35 35
50 6 10 16 16 25 25
150 25 35 50 95 120 120
18.5 31 75 10 16 25 35 35 35
75 6 16 16 25 25 35
175 25 50 95 120 120 150
H-Series 22 36 100 10 16 25 35 35 50
Consult Hyundai for access required when escalator is shipped in two sections.
75 6 16 25 25 35 35
175 35 50 95 120 120 150
26 46 125 16 25 35 35 50 50
100 6 16 25 25 35 35
200 35 95 120 120 185 185
Building Safety Facilities (By Others) 30 52 125 16 25 35 50 70 95
Floor Opening-Top view To ensure passenger safety, full safety facilities around the escalator must be 100 10 25 25 35 35 50
constructed by other contractors. 300 50 95 120 185 185 240
37 60 150 16 35 50 70 95 95
125 16 25 35 35 50 70
Lighting Power
Fire Shutters
Balustrade Vertical Power Supply Power Supply C.B. Rated Power Feeder (mm2)
Type Rise (m) Capacity (kVA) Voltage (AC-1phase) Current (A) 20m 40m 60m 80m 100m 120m
Soffit Guard 1.83-4.27 1.4(3) 30(40) 6 10 16
Wall Opening-Side view Guideboard With Handrail 100-110
4.28-7.6 2(6) 40(70) 6 10 16 25
Lighting
1.83-4.27 1.4(3) 20 4 6 10
(BTL Type) 200-265
4.28-7.6 2(6) 20(40) 4 6 10
3, 200V, 50Hz 3, 220V, 60Hz
Without 100-110 2.5 4 6 10
Safety Railing 3, 346V, 50Hz 3, 380V, 60Hz
& Fence Handrail - 1.2 20
Lighting 200-265 2.5 4 6 10 3, 415V, 50Hz 3, 460V, 60Hz