Sunteți pe pagina 1din 2

RA12-100D (12V100Ah)

RA12-100D is AGM Deep cycle battery with 10 years floating


design life, specially designed for frequent cyclic discharge
usage. By using strong grid and specific paste plate, it makes
battery have 30% more cyclic life time than standby series. It is
applicable for solar energy system, golf cart, electric wheelchair,
Specification etc..
Cells Per Unit 6
Voltage Per Unit 12
Capacity 100Ah@10hr-rate to 1.75V per cell @25 oC
Weight Approx. 30.0 Kg
Max. Discharge Current 1000 A (5 sec)
Internal Resistance Approx. 5 m
o o
Operating Temperature Range Discharge: -20 C ~60 C
Charge: 0 oC~50 oC
Storage: -20 oC~60 oC

Normal Operating Temperature Range 25 oC5 oC


Float charging Voltage 13.6 to 13.8 VDC/unit Average at 25 oC
Recommended Maximum Charging 30 A
Current Limit
Equalization and Cycle Service 14.6 to 14.8 VDC/unit Average at 25 oC
Self Discharge RITAR batteries can be stored for more than 6 months
at 25 oC. Self-discharge ratio less than 3% per month
at 25 oC. Please charge batteries before using.
Terminal Terminal F5/F12
Container Material A.B.S. (UL94-HB) , Flammability resistance of UL94-V1
can be available upon request.

Dimensions
Terminal F12
Unit: mm Dimension: 328(L)172(W)222(H)

Terminal F5

Constant Current Discharge Characteristics: A (25 oC)

F.V/Time 5MIN 10MIN 15MIN 30MIN 1HR 2HR 3HR 4HR 5HR 8HR 10HR 20HR
9.60V 344.7 24 7.0 179.7 110.4 62.40 35.3 9 25 .0 6 20.74 16.3 2 11.92 10.0 83 5.332
10.0V 335.5 23 5.0 176.0 108.6 62.11 35.1 2 24 .9 6 20.64 16.2 2 11.83 9.986 5.235
10.2V 316.1 22 6.7 173.3 107.6 61.54 34.8 4 24 .7 7 20.54 16.1 3 11.73 9.889 5.138
10.5V 283.9 20 9.2 165.0 104.9 60.96 34.5 7 24 .6 7 20.35 15.9 4 11.63 9.792 5.041
10.8V 256.2 19 0.8 152.1 100.3 59.52 33.9 3 24 .0 0 19.87 15.6 5 11.44 9.695 4.944
11.1V 223.0 17 0.5 136.4 93.9 8 56.54 33.3 8 22 .9 4 18.91 14.9 8 10.96 9.404 4.654

Constant Power Discharge Characteristics: W (25 oC)


F.V/Time 5MIN 10MIN 15MIN 30MIN 1HR 2HR 3HR 4HR 5HR 8HR 10HR 20HR
9.60V 35 92 2626 1934 124 6 713 .7 418.6 28 9.2 239.6 188.9 138 .4 113.4 5 9.89
10.0V 35 18 2509 1894 123 0 710 .2 417.0 28 8.6 239.0 187.8 137 .8 112.2 5 9.30
10.2V 33 21 2425 1868 121 6 705 .0 413.1 28 6.8 237.9 187.2 136 .6 111.6 5 8.72
10.5V 29 91 2241 1781 118 8 698 .1 409.3 28 5.1 236.2 185.5 135 .5 110.5 5 8.14
10.8V 26 90 2035 1637 113 4 680 .8 403.3 27 8.2 229.8 182.6 132 .6 109.3 5 7.56
11.1V 23 22 1807 1461 106 3 645 .1 384.7 26 4.4 218.9 173.4 127 .9 105.8 5 5.23

All mentioned values are average values.


RA12-100D 12V100Ah

Li fe ch ar ac ter ist ics of cy cl ic us e Storage characteristic

100
120 Su ppleme ntary ch arge required
0 (Ca rry ou t suppleme ntary ch arge
before us e if 100% ca pacity is
100 80 requires)

Capacity (%)
10
Su ppleme ntary ch arge required
Capacity(%)

80 60 before us e.
This su ppleme ntary ch arge wi ll help
to recover the ca pacity an d sh ould
60 20 be ma de as ea rly as po ssible.
100% 80% 50% 30% 15% 40 40 30
D.O.D D.O.D D.O.D D.O.D D.O.D
Su ppleme ntary ch arge ma y of ten
40 fail to recover the ca pacity.
The ba ttery sh ould ne ver be left
20 standing till this st ate is reached
20

0
Su ppleme ntary ch arge an d st orage
2 4 6 8 10 12 14 16 18 20 22 24 guidelines
0 300 600 900 1200 1500 1800
Number of Cycle(Times) Storage Time (months)

Charge characteristic Curve for standby use Discharge characteristic Curve


15 7.5 5.0 120 0.24
Chcrge Volume 13 6.5 4.3

14 7.0 4.7 100 0.20


Chcrge Voltage T erm inal V oltage (V )
12 6.0 4.0
C h a rg e V o lta g e V

C h a rg e V o lu m e (% )

C h a rg e C u rre n t (C A )

13 6.5 4.3 80 0.16


Discharge
100%0.05CA20h 11 5.5 3.7
12 6.0 4.0 50%0.05CA10h 60 0.12 0.05C
Charge 0.16C 0.093C
Chcrge Voltage2.275V/C 0.35C
Charge Current0.1CA 10 5.0 3.3 0.62C
11 5.5 3.7 40 0.08
Temperature 25
3C 1C

10 5.0 3.3 20 0.04 9 4.5 3.0


Charge Current
0.6 1.2 3 6 12 30 1 2 5 10 20 24
9 4.5 3.0 0 0
0 2 4 6 8 10 12 14 16 18 20 24 28 min Hr

Charge Timeh Discharge Time

Capacity Factors With Different Temperature


Battery Type -20 -10 0 5 10 20 25 30 40 45
GEL 6V&12V 50% 70% 83% 85% 90% 98% 100% 102% 104% 105%
Battery 2V 60% 75% 85% 88% 92% 99% 100% 103% 105% 106%
AGM 6V&12V 46% 66% 76% 83% 90% 98% 100% 103% 107% 109%
Battery 2V 55% 70% 80% 85% 92% 99% 100% 104% 108% 110%

Discharge Current VS. Discharge Voltage Maintenance & Cautions

Final Discharge 1.75V 1.70V 1.60V Cycle service


Voltage V/cell
Avoid battery over discharge, especially battery sereis connection use.
Discharge A1.0C
A0.2C 0.2CA1.0C
Current (A)
Charged with recommend voltage, ensure battery can be full recharged.

In general, recharge capacity should be 1.1-1.15 times discharge capacity.


Charge the batteries at least once every six months,
o
if they are stored at 25 C. Effect of temperature on cycle charge voltage: -4mV//Cell.
Charging Method:
There are a number of factors that will affect the length of cyclic service.
Constant Voltage -0.2Cx2h+2.4~2.45V/Cellx24h,Max. Current 0.3CA
The most significant are depth of discharge, ambient temperature,
Constant Current -0.2Cx2h+0.1CAx12h discharge rate, and the manner in which the battery is recharged.

Fast -0.2Cx2h+0.3CAx4.0h Generally specking, the most important factors is depth of discharge.

SHEN ZHEN RITAR POWER CO.,LTD. Address: Rm405,Tower C, Huahan Building,Langshan Rd16, Nanshan District, ShenZhen, 518057, China
URL:www.ritarpower.com Tel:+86-755-33981668 Fax:86-755-8347-5180 2008 - Version 1