Sunteți pe pagina 1din 33

BALLAST WATER MANAGEMENT SYSTEM

HEAD OFFICE & FACTORY


MEASUREMENT
and CONTROL
For Shipbuilding & Offshore

GIMHAE FACTORY

HEAD OFFICE & FACTORY


#1559-3, SONGJUNG-DONG, GANGSEO-GU, BUSAN, KOREA
TEL: +82-51-831-1010, FAX: +82-51-831-1399
http : / / www.worldpanasia .com
E-mail : panasia@worldpanasia .com

SALES CENTER
TEL: +82-51-970-1513, E-mail : panasia@worldpanasia.com
R&D CENTER
TEL: +82-51-970-1537, E-mail : lab@worldpanasia.com
DESIGN CENTER
TEL: +82-51-970-1526, E-mail : design21@worldpanasia.com
SERVICE CENTER
TEL: +82-51-970-1545, E-mail : service@worldpanasia.com

GIMHAE FACTORY / E&C DIVISION


#715-1, YONGDUK-RI, HANLIM-MYUN, GIMHAE-SI, GYEONGNAM, KOREA
TEL:+82-55-310-3300, FAX:+82-55-343-3318
E-mail : enc@worldpanasia.com
BRANCH OFFICE IN CHINA
Rm 2907, 317 Xianxia Rd, Shanghai
TEL : + 86-21-6235-1601~2 (Ext.8002)
Room 6, 29/F, Rm.04-05 Teemtower, Teemall, 208 Tianhe Road,
Tianhe District, Guangzhou, China
Tel : +86-20-2208-1920
C & C PANASIA
1069 Shary Circle, Suite A, Concord, California, U.S.A
Tel : +1-925-265-1003~4
Catalog No.:Measurement & Control V8 Feb. 2010
Company Profile
Since established in 1989, 20 Years of Experience, Partnership & Performance

2000 ~ Present
Aug. 2009 Acquired NET (New Excellent Technology) Certificate
Jun. 2009 Renewed ISO 9001/2008 & Certified ISO 14001/2004
Feb. 2009 Constructed 2nd plant for Environment & Control division at Kimhae city.
Dec. 2008 Submitted an application for Final Approval of GloEn-Patrol Ballast Water Treatment Sys. to IMO MEPC 59 Session
Mar. 2008 Granted Basic Approval of GloEn-Patrol Ballast Water Treatment Sys. from IMO MEPC 57 session
Jan. 2007 Changed company name to PANASIA CO., Ltd
J u l . 2006 Contracted a high efficient DeNox System for IST project in New York
Jun. 2005 Collaborated the technical & marketing division with Endress+Hauser Korea Co., Ltd
Jun. 2004 UL certified for Level switch(PR-30 series) & Level transmitter(CPR-100)
Dec. 2003 Appointed as INNO-BIZ factory from the Government
J u n. 2003 Appointed as a promising exporting company from Export Assistance Center.
May. 2003 Achieved ISO 9001:2000 certificate(DNV).
Sep. 2002 Appointed as Clean Factory from Ministry of Labor.
A p r . 2001 Appointed as Superior Exporting firm from Export Assistance Center.
A p r . 2001 Awarded the prize from the Minister of Science and Technology.
Sep. 2000 Moved to New Factory in Nok-San Industrial Complex.

1989 ~ 1999
J u n. 1999 Opened R & D Laboratory.
J u n. 1998 Appointed as a promising venture company by Korea Electric Power Corp.
J u n. 1998 Achieved ISO 9001 certificate (DNV).
Mar. 1998 Registered Korea Electric Power Corp. as a supplier for Level Instruments for a nuclear power plant.
Nov. 1997 Awarded a prize for "A Proud Korean" by the president of Korea.
May. 1997 Appointed as a promising technical developing company from Government.
Mar. 1997 Awarded the prize of an excellent technical development from Government.
Mar. 1996 Registered as a sub-supplier of STX(Daedong) Shipbuilding Co.,Ltd.
A p r . 1993 Appointed as a localizing manufacturer for Level Instrument by the Korean Government.
Feb. 1993 Awarded the excellent development prize by Hyundai Heavy Ind.Co.,Ltd.
J u n. 1992 Concluded the technical & marketing collaboration agreement with IPH MARINE AUTOMATION A/S in DENMARK.
Mar. 1990 Registered as a sub-supplier of Hyundai Heavy Ind. Co., Ltd.
O c t. 1989 Established PAN-ASIA PRECISION & ENGINEERING Co.,Ltd. as a manufacturer of
Level Instrument in the field of marine industry.

COMPANY PERSPECTIVE

More than 10,000 ships


More than 20 years

PANASIA CO.., LTD. 2 3


The Leader in Measurement & Contents
Control Technology
08 Radar Beam Type Cargo Tank Monitoring System
12 Magnetic Float Type Cargo Tank Monitoring System
14 Magnetic Float Type High & Overfill Alarm System
Long Accumulated Know-How and 16
18
Acoustic Type High & Overfill Alarm System
Valve Remote Control System
Technology are sure of satisfying customer s needs. 20 Air Purge Type Tank Level & Draft Gauging System
22 Electric Pneumatic Type Tank Level & Draft Gauging System
Hoping your business to be prosperous continuously, we sincerely appreciate your 24 Electric Pneumatic Type Tank Level & Draft Gauging System (Level Pride)
cooperation and support since its establishment in 1989. 26 Electric Pneumatic Type Level Transmitter
Despite many setbacks and hardships over the past eighteen years, 28 1:1 Converter (Pneumatic Tank Level Gauge)
We, PANASIA has managed to achieve solid growth by turning crisis into opportunity.
30 Electric Pressure Type Level Transmitter (LEVEL-3000)
And also grown into one of the leading companies in the field of level measurement &
control technology of marine engineering.
32 Water Ingress Alarm System
Based on our slogan "Dream & Tomorrow",we have always been motivated by passion 34 Pressure Monitoring System
and a willingness to take on any challenge to make the future better. 36 Vapour Emission Control System
We will secure world-class level measurement & control technology of marine 38 Fixed Gas Detection System
engineering and understand changes in the markets and with customers. 40 Pump Room Bilge High Level Ararm System
Through this we will play a role as a global company that has the market knowledge to 41 Temperature Monitoring System
lead our customers. We will continue making innovations and changes.
We ask for your continued interest in PANASIA CO.,LTD 42 Flat Type Glass Level Gauge
and hope you will keep watching our ever-changing company. 44 Reflex Type Glass Level Gauge
46 Magnetic Float Type Level Gauge
48 Self-Powered Contents Gauge
50 Dial Type Float Level Gauge
52 Float Type Level Switch
56 Displacement Type Level Switch
Yours sincerely 58 Reed Switch Type Float Level Switch
62 Electric Indicator
63 Digital Indicator
64 Class Approvals
65 World Wide Service Network
President Robert SooTae, Lee

MARKETING TEAM DESIGN TEAM R & D TEAM SERVICE TEAM PRODUCTION TEAM

PANASIA CO.., LTD. 4 5


Tank Monitoring System
Product List
01. Cargo monitoring System
Radar Beam Type
Magnetic Float Type
02. High & Overfill alarm system
Magnetic float type
Acoustic type
03. Valve Remote Control System
04. Tank Level & Draft gauging System
Air purge type / Electric pneumatic type
Electric pressure transmitter type
05. Vapor Emission control system
06. Fixed gas detection system
07. Water ingress alarm system
08. Pressure / Temperature monitoring system
09. Bilge high level alarm system
10. Local level gauge / switch

PANASIA CO.., LTD. 6 7


Radar Beam Type
Cargo Tank Monitoring System

Application Technical data Your benefits


Level-Radar is used for continuous non-contact level Up to 35m depending on 2-wire technology, low price.
measurement of liquids in Cargo Tanks and Slop Tanks of Measuring range installation, product, surface a real alternative to differential pressure, floats
Crude oil carrier, Oil & Chemical Carrier. conditions and antenna size and displacers. 2-wire technology reduces wiring
The measurement is not affected by changing media, costs and allows easy implementation into
temperature changes, gas blankets or vapours. 4...20mA, HART PROFIBUS PA, existing systems.
Output
FOUNDATION Fieldbus. Non-Contact measurement:
Measuring accuracy 3mm Measurement is almost independent from
Measuring Principle Measuring cycle 1sec product properties.
ATEX 1/2 G EEX ia C T6 Easy on-site operation via menu-driven
Level-Radar is a "downward-looking" measuring system, Certification
ATEX 1/2 G EEX d[ia] C T6 alphanumeric display.
operating based on the time-of-flight method. Easy commissioning, documentation and
Product temperature -40 to 150
It measures the distance from the reference point(process diagnostics via operating Software (ToF Tool)
connection)to the product surface. Pressure from vacuum to 40 bar.
2 frequency ranges-26GHz :
Radar impulses are emitted by an antenna, reflected off 1 thread DN50(2) No compromises, the right frequency for every
Process connection
the product surface and received again by the radar ..DN150(6) flange application.
system. Major material SUS316 HART or PROFIBUS PA respectively
Beam angle 8 FOUNDATION Fieldbus protocol.
Weight 10kg

HAZARDOUS AREA NON-HAZARDOUS AREA


Principle of Radar-Technology

Generator Emitter

Timer Receiver
d

t d=c t
2

PANASIA CO.., LTD. 8 9


Advantage of 2 Frequencies Solution for a narrow and small tank
like Slop tank or Residual tank

3 +
Levelflex M FMP40

~26GHz
Increased accuracy.

Sensitivity against Build-up,


foam and turbulent surface
Small beam angle
Ideal in small vessels.
mm-accuracy

~ 6GHz
Less effected by turbulent
surface and foam
Less effected by condensate
and build-up
10 -
- Size of antenna / beam angle +

ToF Family-Commissioning
Multi-line plain text display.
Removable display for comfortable operation. Commissioning-easy,
Menu-guided operation in national language. fast and safe
Help for parameter setting.

Measuring Precisely and Technical data


Display Tool
independent of temperature, Process media Liquids and solids
pressure and gas layers Measuring range 35m cable, 4m rod
Output HART, PROFIBUS PA, FF
Product density and variation of density 2-wire 4...20mA loop powered,
power supply
Turbulent surfaces or foam 4-wire AC/DC
Wall material of the vessel Temperature -40...+150 (pressure up to 40 bar)
Shape of vessel
ATEX 1/ 2 G,
Uniform operation concept. Obstacles Certification
ATEX 1/ 3 D
Graphical support and online help (BA, TI,..) Protection IP68
Documentation of measuring point incl.
envelope curve
Integrated program for tank linearization and
curve calculation of channel measurement

PANASIA CO.., LTD. 10 11


Magnetic Float Type
Cargo Tank Monitoring System

General Working Principle Standard Specification


The Tank Monitoring System, named as PATROL system is a magnetic float type tank level gauge Sets of reed switches are positioned along the Level Detecting Part
featuring an all-in-one detector that measures tank level, temperature,vapor pressure, as well as issuing length of the guide pipe. Type Read Switch with Magnetic Float
alarm when limits are exceeded. As the float travels up and down the guide
The TANK MONITORING SYSTEM monitors these tank conditions on various display units. pipe in accordance with the level of the liquid Anti-Explosion Structure Ex ia C T6
Information on ballast tanks, fuel oil tanks and draft gauges, as well as cargo tanks can be comprehensively in the tank, Measuring Range 50m, max
utilized by integrated ship operation control system via a loading computer. the flux emitted from magnets within the float
Specific Gravity 0.5 and above(of liquid in tank)
works upon the reed switches ON or OFF.
A key feature of the Tank Monitoring System is its ease of handling, because the sensors in the detector are By measuring voltage across the transmitter Viscosity 15,000sec. Redwood No,1 max.
flexible, it can be lifted up by hand without the need to enter tanks, even in the case of cargo tanks of crude circuit, the level of the liquid can be calculated Detecting Accuracy 20mm (option:10mm)
oil Tanker, Product oil Tanker, chemical carrier for repair and maintenance. according to the changes in circuit resistance.
Likewise, transportation and fitting of the Tank Monitoring System is also simple. The converted signal is sent to the control box Allowable Temperature -60...+150 (stand.), -162 (option)
For LNG carrier, this magnetic float type tank level gauge is usually provided in W.B.T & Draft gauge via I.S. barrier in the control room or to a local Allowable Pressure 3kgf / (option:80kgf/ ,max.)
system and F.O tank level gauge system. indicator as the case may be.
Temperature Detecting Part
Type Two-terminal IC, temp, Transducer
Measuring Range -55/+150
Detecting Accuracy 2

System

HAZARDOUS AREA SAFETY AREA

Local Indicator Level/Temp./I.G.


Pressure Transmitter

Tank Top
Application
Crude oil
Product oil
Chemicals
Sea Water
Fresh Water

High & Overfill


Alarm Switch

Installation of
Bottom Support Cargo Monitoring Console

PANASIA CO.., LTD. 12 13


Magnetic Float Type
High & Overfill Alarm System

General Operating Principle High & Overfill Alarm Switch Overfill Alarm Switch
The PANASIA high level alarm sensor consists of magnetic float and reed switch built in guide pipe.
When the magnetic float moves upward with rising level, the hermetically sealed magnetic reed switch inside
the pipe will be de-activated. Model : PR-30EX-2 Model : PR-30EX-1
This switch will be in an open-state position, which output alarms.
When the magnetic float moves down ward with falling level, the reed switch switch will be activated and will
be in a closed-state position (non alarm position).
This means a normally operated fail to safe loop.The 95% switch is normally for high alarm.
The 98% Switch is normally for high-high alarm(overfill alarm)
A test lever is provided for manually functional test to check integrity of high level alarm system before cargo
loading.
Operating Signal

Remark
Cargo Tank High & Overfill Alarm system is throughly designed according to Model:PR-30EX-
USCG latest requirements and are to be required by IBC Code Connection Diagram

Technical Specification
Detection units Reed switch with magnetic float
Detecting Accuracy 5mm
Switch Contact Rating 250VAC, 1A
Specific Gracity 0.6 above
Housing-SUS316
Flange-SUS304/SUS316
Material PR-30EX-
Guide pipe-SUS304/SUS316
Float-SUS316, Titanium Number of float
: 1 float
Anti-Ecplosion Structure Intrinsically safe type : 2 floats
Allowable Pressure 6kgf/
Air Horn
Installation-JIS 5K 100A FF/125A FF
Connection Size JIS 5K 125A FF(with chamber)
Conduit-JIS 5K 32A or JIS 5K 40A

Alarm Point High alarm-at 95%of cargo volume


Over fill alarm-at 98% of cargo volume
Type approved by KR,ABS,DNV,LRS,BV,GL,NK,RINA

Electric Horn with


Strobe Light High & Overfill Alarm Unit Air supply 6~8 bar

PANASIA CO.., LTD. 14 15


Acoustic Type
High & Overfill Alarm System

Remark Applications
Cargo Tank High & Overfill alarm system is throughly designed according to USCG latest requirements High level alarm and Overflow alarm under IBC code, USCG & IMOs
and are to be required by IBC Code. latest requirement in any type tanks, esecially cargo tanks on chemical
/ product tanker, crude oil carrier.
Features
Maintenance Free Electrical connection Flexible Hose
Design of no moving part and simplified structure resulted strong enough and maintenance free product,
which is endurable sloshing wave or exces vibration in the tank.
For all kind of liquid
This equipment is sustainable to all kind of liquid in the tanks, such as crude oil, high viscous bunker oil,
petroleum products, chemical, etc. And no correction is required for the specific gravity.
Check apparatus before loading
Specially designed magnetic circuit is given for the operational check before loading cargo in the tank,
which is required by SOLAS and Federal Rule for Coast Guard. ELECTRICAL CONNECTION
Tank Pressure Monitoring
Built-in type pressure sensor could be provided additionally in the housing for oil/chemical tanker as option.

Operating Principle
Technical Specification Acoustic Type Level Switch
The sensor is based on the principle of distributed acoustic waves in a metal rod.
If the rod is not covered by liquid then the sound waves are dispersed freely without any interference. Model : PA-LW2
When liquid covers the rod then the emission of sound waves is muffled and his interference is picked up Top mounting < 3mm
Repeatabillty
by the sensor and transmitted to the alarm and control panel. Side mounting < 1mm
On the alarm and control panel are displayed warning indication lights for set level 95% and alarm 98%signal current loop with 16mA no alarm
when the set or alarm level is reached. The board contains relays which control the audio and visual alarms. Output
6mA alarm
I.S approval EEX ia IIC T6
Protection IP56
Piezo-electrical transducer Model : PA-LW2 18 to 30V DC
Power supply
Nominal 24V DC

Ambient -40 to +85


Operating temperature
Liquid -40 to +150
Metalic rod
Electrical connection 2 or 4 wires
Material Stainless Steel 316L
Weight 0.7k g (with L=100mm)

Netural part
10

Sensitive part
Propagation of acoustic
waves in side the metallic rod

PANASIA CO.., LTD. 16 17


Valve Remote Control System

Introduction
The AMRI-SEIL / PANASIA VRC system is designed for position indication and electro-hydraulic remote Electric line
control of hydraulically actuated valves. The principle of the VRC system is that pressurized oil, generated hydraulic pressure line
by the power pack, is used to open or close the valve by means of the solenoid controlled actuator. Hydraulic returen line

Safety Area

The actuated valves are installed in Solenoid Valve Rack Interface Panel Automation System
safety area. (Ballast and Engine room etc) Solenoid valves are used to control the The interface panel consisting of relays, Remote operation by the computerized system
direction of oil flow to each actuators Power supplier, Converters and Barriers,
operated by an electric signal from control etc., is required to communicate between
console installed in safety area. valves and computerized control system.

Hazardous Area

The actuated valves are installed in Deck Box Hydraulic Power Pack Control console & Mimic panel
hazardous area. (In-tank and On-deck) The deck box controls the functions of The hydraulic power unit consists of oil tank, Remote operation of the conventional type by the control
each actuated valve installed in hazardous electric motor & hydraulic pump which generates console with mimic panel.
areas via explosion proof solenoid valves. the required system operating pressure.

PANASIA CO.., LTD. 18 19


Air Purge Type
Tank Level & Draft Gauging System

Operating Principle Specification


The operating principle is based on the measuring the hydrostatic head of the liquid by providing constant Type of system one(1)-Line air purge system
low flow of air into a probe (called as sounding pipe) which opens at the tank bottom.
When a light quantity of air (supplied from flow regulator) is discharged through the purge mouth at the tank Accuracy 1% of F.S, if drawn scaleindicator calss 0.5
bottom, An air pressure corresponding to the liquid level (considering the viscosity) will be built up in the
sounding pipe. -25 to + 75
Working temperature (It must be secured that the dew point
If the specific gravity of the liquid is known and a pressure in the sounding pipe is measured, it is possible to
calculate the distance from the pipe opening to the surface by means of the above expression. of the air lies below Min. Temperature)
The pressure is read on the indicator graduated scale in meters or volume or percent of full tank. Air flow consumption 5 to 50N/min
Operating air pressure rating 4 to 7kg/
Signal pipe OD 8mm
Valve casing alloyed brass with protect cover(SUS304)
Pneumatic indicator

Constant flow regulator Air supply unit

Pressure switch
for alarm(option)

Air purge head

Draft Box

PANASIA CO.., LTD. 20 21


Electric Pneumatic Type
Tank Level & Draft Gauging System

Operating principle
The operating principle is basically the same as the level
measuement of air purge type tank level monitoring system.
Monitoring Computer Electric indicator But Electric pneumatic type tank level gauging system has
electric reading and P/I Converter that converts pneumatic
input signal to 4-20 mA output signal in addition to air purge
type system.

Analog interface
Signal distributor Application
module
Ballast tank level measurement.
Draft measurement.
Engine room tank level measurement.
RS-485
(F.O, D.O, L.O, etc)
4-20mA

P/I converter Air supply unit

4-20mA

P/I converter
Constant The upgraded P/I converts is provided to converter an
flow regulator
pneumatic pressure into an electronic signal for remote
display of tank level and draft gauge on CRT and /or
Electric indicator.
Unlike the pneumatic indicator possible to be damaged by
excess-pressure, this P/I converter is free from inlet
excess-pressure without even Gauge saver.
Model : P940
Output current : 4 to 20mA DC,
2-wire system.
Protection against inlet excess-pressure.
Air purge head

Draft Box

PANASIA CO.., LTD. 22 23


Electric Pneumatic Type LEVEL PRIDE
Tank Level & Draft Gauging System

Introduction System diagram


Level Pride is specialized on electric pneumatic air purge system. Level Pride is equipped with all the
necessary components such as air supply unit, constant flow Regulator Module(PA-1500), sensor
Module(PAMX-2000)in one module. You need just one module for measuring 10 tanks. If you have more
tanks to monitor, just plugging each other with LAN cable and set the some configuration. One of the Level
Pride module which is configured as master finds all the slave modules connected with and calculates
information automatically.

Features
10 Tank interface without any additional components. (Air purge System)
-Built-in Air supply unit, Constant Flow Regulator Module (PA-1500)
-Sensor Module (PAMX-2000), 12 bit A/D converter.
Various kind of correction function.
-Specific Gravity, Trim & Heeling, Sensor position
-Volume converting according to the Volume table
Various display format of the tank information to the user
Industrial standard serial link and Ethernet link
-10Mbps LAN 1 channel
-RS232/485 1 channel each
Windows based Configuration program for easy setting & calibration
-Module/Ship/Tank/Channel setting

Specification
Type of system one-line air purge system
Air supply 6~10bar, set to 4bar
System accuracy 1% of Full scale
CPU Intel StrongARMTM SA1110-206MHz
OS Linux for embedded system
ROM 16MByte Flash ROM
RAM 64MByte SDRAM, PC100
Display 4 20 character VFD (Vacuum Fluorescent Display)
Input 10 air pressure from tanks
2 serials (built - in RS232/485)
1 LAN 10base - T
Output
Analog output (4~20mA, 1~5V)-Option
Dry contact - Option
Operating temperature -10~45 (under dry air condition)
Operating humidity 0~80RH
Dimension 450 350 240(mm)
Weight App. 20kg
Electric Power 85 ~ 250VAC, 50 ~ 60Hz

PANASIA CO.., LTD. 24 25


Electric Pneumatic Type
Level Transmitter

Features
High accuracy
Long term stability
4-20mA Output signal
EEx-version(EEx ia llC T6)
Easy installation
Easy maintenance

Application
Analog
The level transmitter can be used for measuring level Interface Module
contents in open such as WBT.
F.O TK. in E/R etc. Additionally the level transmitter is
available in Ex ia-version.
It is easy to install in all types of vessels because all of the
parts is in one.
The Electro-pneumatic transmitter has developed focused
on saving on installation cost with best reliability.
OUTPUT
Digital Monitoring
Function Indicator
4-20mA Computer
The principle of operation is based on the measurement of the hydrostatic pressure at the bottom of a tank
where air is injected continously through a sounding pipe.
A pressure corresponding to the level of the liquid will be built up in the sounding pipe.
This pressure will be measured by the transmitter and converted into a 4 to 20mA signal.

Technical data
Output 4-20mA, 2wire system Naval brass
Material
Load equation RL (Vcc-10)/22[ ] stainless steel
e.g.:24V supply RL<636 Air supply clean dry air 4~8bar
20mm from 0 to 10meter level Min. pressure 0.5bar above range
Accuracy
40mm from 10 to 35meter level Air consumption approx. 30 IN/ h

Temperature -10 ..+70 <=0.5%


stability for main range
(overall temperture-range)
Power supply nominal 24V DC
range 10...30V
Effect of voltage
zero point 0.005% pro V
variation
span 0.001% pre V

Damping 0-200s adjustable


Insulating current 500V

PANASIA CO.., LTD. 26 27


1:1 Converter
(Pneumatic Tank Level Gauge)

Operating Principle Technical Data


On one side, the diaphragm is affected by the medium in the tank which is to be measured. the pressure by Measuring range 0-30m H2O
which the diaphragm is affected is the hydrostatic pressure of the fluid or gaseous medium. Air supply 1.4bar or minimum 1.2 measuring range
On the other side, the diaphragm is fastened with the pressure converter, forming so a pressure chamber. Via Air consumption At 1.4 bar air supply approx.30 /h (emth tank, otherwize less
an air supply and a throttle, measuring air is applied to the pressure chamber where a pressure corresponding at 2.5 bar air supply approx.40 /h
to the hydrostatic pressure of the medium develops. This pressure can be shown by an indicating Instrument. Viscosity
3500 Redwood 1 sec.
the pressure on the supply of measuring air must always exceed the highest media pressure. (measured with water)
Excess air is blown out through the nozzle in the center of the pressure converter. Including reaction sensivity and hysteresis at 1.4 bar.
To avoid distortion, the flange must be fastened at least 4points before final welding. Connecting tubes of at emtpy tank and free discharge nozzle : max.25mm
stainless steel or copper are to be used between pressure converter and indicating instrument/air supply. Tolerances
>0.1m tank level measured from middle of diaphragm : max. 25mm 0.75%
The O-point drift depends on the pressure loss caused by possible hose / tube
mounted on the discharge nozzle.
-40 to + 200 (4bar)
Temperature range
Depends on tube dimension and tube length from pressure converter to
Rasponse time
indicating instrument as well as supply

Air supply Internal tube Pipe length Reponse time Change in level
1.4bar 6mm 30m approx.10s 55mm/s
1.4bar 6mm 50m approx.20s 55mm/s
1.4bar 6mm 100m approx.50s 55mm/s
1.4bar 6mm 300m approx.4min 55mm/s
2.4bar 6mm 100m approx.5s 55mm/s

Application
Primarily for as an indirect continuous measurement
of level and cubic contents respectively of liquid in
containers and tanks.
Our 1:1 converter is espectaily suitable for hygienic
purposes within the food, beverage and chemical
industries as well as for potable water tanks.

PANASIA CO.., LTD. 28 29


Electric Pressure Type
Level Transmitter (LEVEL-3000)

Tank Contents Transmitter Connection on junction box


This is a 2-wire 4-20 mA level transmitter consisting of a transducer and an amplifier connected via a 6-core
vented cable. The transducer is a pressure sensitive silicon micro strain gauge sensor mounted in a glass to
metal seal. The sensor is protected by an isolation diaphram, electron beam welded to the transducer housing,
with an oil filling between the sensor and the diaphragm. Pressure changes in the front of the diaphragm will
bring a resistance change in the Wheatstone bridge of the transducer.
This change in the Wheatstone bridge will be transmitted to the amplifier as a change in the electrical signal.

Application
?'@@(?g
?V40Y?g
BALLAST TANK REMOTE READING
?'@@(?g
?V40Y?g
DRAFT REMOTE READING
?'@@(?g
?V40Y?g
HEELING AND TRIM REMOTE READING
?'@@(?g
?V40Y?g
FUEL OIL TANK REMOTE READING
?'@@(?g
?V40Y?g
WASTE WATER, WELLS, LOCKS, RIVERS ETC.

Feature
??
??

PIEZORESISTIVE SENSOR ELEMENT


??
??
??
'@(?g??
V+Y?g? ??
??
??
??
???

STAINLESS STEEL/TITANIUM MATERIAL


???
??
??
'@(?g?
V+Y?g??
??
??
??
??
??

CONNECTABLE TYPE(CABLE CONNECTION PLUGGABLE)


??
??
??
?
'@(?g?
V+Y?g??
??
??
??
??
??

TEMPERATURE MEASURING WITH PT100(OPTION)


??
??
??
?
'@(?g?
V+Y?g??
??
??
??
??
??

DIRECT OUTPUT TYPE(NO AMPLIFIER BOX)


??
??
??
?
'@(?g?
V+Y?g??
?
??
?
??
?
?
?

HIGH MEASURING ACCURACY


?
?
?
?
?
?
?
?
'@(?g?
V+Y?g??
??
??
??
??
??

HIGH TEMPERATURE STABILITY


??
??
??
?
'@(?g?
V+Y?g??
??
??
??
??
??

NO HYSTERESIS
??
??
??
?
'@(?g?
V+Y?g??
??
??
??
??
??

MARINE CLASS APPROVAL


??
??
??
?
'@(?g?
V+Y?g??
??
??
??
??

Technicall specifications
Parameter
0~0.25bar, 0~0.5bar, 0~1bar, 0~2bar, 0~4bar, 0~6bar, 0~25bar, -1~5bar Each span
Measuring Range
range is programmable in use calibration kit.
Transducer Type Piezo-Resistive Type Transducer
Non-Linearity 0.25% @ 20 4~20 mA DC loop Connection on junction box Outline / Dimension
Output
Long Term Stability Max 0.1% / year powered 2 wire

Total Error Band Typically 20.8 mA


Max. 2.0% @-25 ~ 85 Current Limiting
(Programmable)
/Xg?W.?e??
??
??
??
??
Built-in Temperature Sensor Pt100 (Optional)
Over Pressure Min. 3 Transducer Range
V/X?fW.Y?e?
?V/Xe?W.Yf?
V/X??7H?f?
?N)KC5g?
@@@Hg?
@V'Lg?
?J5?N1g?
W.Y??3L?f?
?W.Ye?V/Xf?
W.Y?fV/X?e?

Transducer/Transmitter Material
.Yg?V/?e??

SUS316L / Titanium
??
??

Burst Pressure >200 bar Protection Class IP68 (Fully Submersible)


Operating Temperature -25 ~ 85 (Option125 ) Ex-Approval Ex ia IIC T4
The Power supply can vary from 10 ~ 38 VDC.
Permissible load resistance is shown graphically below.

Power Supply

PANASIA CO.., LTD. 30 31


Water Ingress Alarm System
This system is designed to detect the presence of water in
the cargo holds and intended for usage on bulk carriers.
The system is in accordance with Configuration
SOLAS chapter XII/12
IMO Res. MSC. 145(77) The water detectors are installed at a height of 0.5m above inner bottom and another at a height not less than 15% of the
IACS SC 180 depth of the cargo hold but not more than 2.0m. In any ballast tank forward of the collision bulk head, the detector is
installed at a height not exceeding 10% of the tank capacity. In any dry or void space other than chain locker, any part of
which extends forward of the foremost cargo hold and the volume of which exceeds 0.1% of the ship s maximum
displacement volume, the detector is installed at a height of 0.1m above the deck.

Principle of Operation
Electrode type level switch is suitable for level detection in conductive liquid.
If the electrode comes into contact with the liquid, the A.C current will flow through the liquid and complete the
circuit. This AC current can be amplified and fed into electronic converter in sensor housing that detects
changes in its input current caused by rising medium. this change are converted into a corresponding current
change. If the changes exceeds an adjustable limit value, the output current rises discontinuously to > 3.4mA
The I.S.Barrier/signal converter in alarm panel uses this information to switch isolated contacts.

Feature
No moving part
Reliable
No damage by cargo
Easy to maintenance
Insensitive to cargo solids

PR-30EX HR-665261
(Float type) (Rod type)

Specification Major Function


Certified to Ex ia C T6 Pre-alarm at 0.5m
Main alarm at 2m Design to minimize
Ambient temperature -25 ~+70 Fault/malfuncition alarm. a cost to shipowner
Liquid temperature -20 ~+70 (line monitoring)
Override/interlock function
Pressure 0~5 bar Automatic cancellation of
Housing material SUS316 override condition
Process connection Thread G1-1/4A or Flange. Override indication
Power failure alarm
Protection class IP56, IP65, IP68 Power automatic switchover
Normal voltage 4.6V to 30V DC Lamp/buzzer test
Common alarm
unswitched < 1mA, Alarm time delay Least cost to retrofit
Normal current
switched > 3.46mA Function test in-situ. existing bulk carriers
Measuring voltage AC5V
Max. no-load current 1
Max. short-circuit
Frequency 50kHz

PANASIA CO.., LTD. 32 33


Pressure Monitoring System

General
The pressure monitoring system is designed for cargo tank & manifold pressure monitoring for any number of tanks.
The vapour pressure monitoring system is intended for pressure monitoring of waste return lines.
Computer Monitor
The PANASIA pressure transmitter is carefully designed to meet a harsh marine application for the tank pressure
monitoring system in accordance with SOLAS II-2/59 amended in 1996, and vapour pressure monitoring system required
under 46CFR part 39. 20-13 of VECS.
Electric horn with strobe light The transmitter is a high quality and accuracy semi-conductor type especially suitabe for the low pressure to be measured.

Operating Principle
RS-485 The transmitter measures the pressure by means of a semi-conductor sensor. Pressure changes in front of the diaphragm
will bring about a resistance change. The change in resistance is linearly proportional to the applied pressure and is
amplified by an integrated electronic amplifier to give an output signal. The electrical signals from the pressure transmitters
4-20mA on deck are connected to zener barriers in the monitoring cabinet equipped with pressure alarm lamp, buzzer and pressure
indicator in the cargo control room.
Pressure
monitoring panel
Technical Specification
SAFETY AREA

Analog interface
module
Power supply DC 10-30VDC
Accurcy 0.5% FS
Response time <1ms/10...90% FS
Measuring Range 0~25bar
Over load pressure Min.3xFS
Barrier Barrier Burst pressure 200bar
4-20mA
Output signal 4-20mA
Process Connection G1/2A(PF 1/2 )
Approval KEMA 03ATEX1127
Enclosure IP65(DIN 43650)
HAZARDOUS AREA

Ambient temperature -25 ~ +85 (T4)


Medium temperautre -25 ~ +100 (T4)

PANASIA CO.., LTD. 34 35


Vapour Emission Control System
(O2 Content and Vapour Emission Pressure)

General Operating Principle


This is a complete system to monitor oxygen gas content and vapour pressure in the waste vapour and The system has four(4) sample points and only one sample is directed and monitored individually through selecting valve
manifold lines from vessels. this system complies with USCG Regulation for Cargo vapour emission control at the time. The sampling lines are run from the respective sample point to the panel in a hazardous area. Sampling gas is
system for tankers. All necessary parts are intrinsically safe protected. purged to a atmosphere. Oxygen sensor is designed for monitoring content from 0 to 25 V%. Indicator in control room
activates High O2 alarm at 8% which was preset and gives audible and visual. Flowsensor fitted on flowmeter monitors
sampling gas low flow and activates alarm when flow rate is under minimum flow level.
Pressure transmitter monitors the pressure in waste vapour and manifold line.
Low and High pressure alarm is set at 10mbar and 120mbar respectively.

Technical Specification
Power supply 115/230 VAC (50-60 Hz)
Air supply 6-8 bar
Fuse 10 A
Oxygen Sensor 0-25% Volume
Alarm Points 1
Oxygen Gas & Vapour
Press Detection Cabinet
Set Point 0-100%
Explosion Proof EEx ia IIC T4
Pressure Transmitter 200mbar
Alarm Points 2
Main Components Set Point 0-100% Full Scale
Hydrocarbon Sensor 0-100% LEL n-Butane in air
Oxygen sensor Filter & Selection valve Vaccum pump Oil less carbon vane pump
Flow meter Annunciator Calibration Test gas from gas bottles
Pressure transmitter Digital indicators

Version Version

HAZARDOUS AREA SAFETY AREA HAZARDOUS AREA SAFETY AREA

FUNCTION
1.OXYGEN CONTENT DISPLAY
2.HIGH OXYGEN CONTENT ALARM(8%)
3.VAPOR PRESS. MONITORNG
4.VAPOR PERSS.
HIGH ALARM(0.125bar)
LOW ALARM(0.01bar)

PANASIA CO.., LTD. 36 37


Fixed Gas Detection System

General P & ID Program


The sequential gas sample system is a multi point
gas-sampling unit designed to detect and provide
alarms for the presence of flammable and hydrogen
sulphide gases within the water ballast tanks and
void spaces.
The system is designed to extract a gas sample from
each sample point via sample piping to the analysing
unit where the flammable and hydrogen sulphide gas
content is measured. By using solenoid valves,
the unit provides an effective way of sampling multiple
locations using only one sensor for gas detection.
The system utilises a heavy-duty sample pump to
extract a sample of gas from each of the sample point
locations. The extraction circuit incorporates a flow
sensing device to annunciate a flow failure if the pump
cease to operate or sample lines become blocked.
Solenoid valves are used to select each sampling line
for analysis in a sequential or pre-programmed
sampling sequence. Furthermore, the system is
extendable by adding additional valves, which are
automatically recognised and activated.
Flame arrestors are installed on all sample lines
iaccordance with class regulations.
The system can supply information to the vessels AMS
system via a communications protocol which allows for
a real time flow of information including the current
location being sampled and the gas concentration
level at this location.

Indicators
LCD Display - High Alarm Lamp - Low Alarm Lamp - System Failure Lamp -
Main/Pre Flow Failure Lamp - Sensor Fault Lamp - Standby & Main Power Supply The system is designed to provide protection of the following areas : Cargo pump rooms; Cofferdams ; Pipe tunnels ; Ballast
tanks and double bottoms ;Void spaces ; Other empty areas adjacent to slop tanks.
Additionally, stool tanks and other empty areas adjacent to cargo tanks can be protected.
When locating fixed sampling points within ballast tanks, areas where an explosion is most likelyto occur must be assessed.
Specification The risk of explosion is mainly related to the release of cargo vapours through the ballast vents in the top of the tank, during
ballast filling. Hence it is considered sufficient that detection takes place in the upper part of the spaces whengas
Sensor No. Sensor No.1 Sensor No.2 Sensor No.3 concentrations reach detectable levels.
Main supply 220VAC 60Hz
We advise that ballast tank-sampling positions belocated at the top of the tank.
Emergency supply 220VAC 60Hz Sensor type Infra-Red Electrochemical Electrochemical
The sampling system extracts gas samples from a maximum of 48 lines and the default sample sequence is to cycle from
No of sample points Up to 48 Range 0~100% LEL 0~50ppm 0~25% VOL channel 1 to 48 and then back to channel 1 again. The time that thesystem samples on a channel can be altered for each
Sample time per line 60 Seconds Calibrated Gas Butane Hydrogen Sulphide Oxygen sample line to compensate for varyingsample line lengths.
Low alarm trip point & type 10%Rising 5ppm Rising 16% Falling Flame arrestors are constructed from stainless steel and designed to prevent the propagation of
Power shut down 30% LEL flames from the analyzing unit if a fire occur within the unit. Flame arrestors are provided as loose
High alarm trip point & type 30%Rising 10ppm Rising 24% Rising
items to avoid any damage to the unit during dispatch.

PANASIA CO.., LTD. 38 39


Pump Room Temperature Monitoring System
Bilge High Level Alarm System

General Temperature Monitoring System


IMO MSC-67 issued a safety circular recommending measures to take to prevent explosion in oil tanker
cargo pump room for new and existing tankers. OCIMF also recommends that all pump rooms shoud be
provided with a high level alarm which activates audible and visual alarms.

Operating Principle
Level switch monitors level in bilge well. With rising level, switch gives output signal to alarm panel and
then activates audible and visual alarms.
Computer Monitor RS-232

Application PATM-5000 series Module is designed for being integrated in a housing and fully compatible with RTD. thermocouple and
thermister etc,. This module can be supplied as complete or partial system with later additions.
Pump Room Bilge
E/R Bilge

PC-based Programmable Controller


Cpu : 16-bit microprocessor Built-in realtime clock
Memory : Up to 256KB Flash ROM, 256KB SRAM Built-in Watchdog Timer
Operating system : Rom-DOS 3 communication ports supported
Built-in Paradym-31 Runtime Engine (COM 1:RS-232;COM2:RS-485:COM3/Programming
SAFETY AREA

(ADAM-5510/P31 only) Port:3-wire RS-232)

Distributed DA&C system Based on RS-485


Support master/slave communication
ASCII command/response
2-wire, multidrop RS-485 network
Transmission speeds up to 115.2Kbps
HAZARDOUS AREA

7-channel Thermocouplelnput Module


16-bit resolution
7 differential input channels
Software configurable for T/C, mV, mA input
3000 VDC isolation
External cold junction compensation

3-channel RTD Input Module


16-bit resolution
3 RTD input channels
software configurable for Pt or Ni RTD input
Input connection:2,3 or 4wires

PANASIA CO.., LTD. 40 41


Flat Type Glass Level Gauge

PA-FLG-P100 Series
The PANASIA Flat type level gauge is designed according to JIS standard PA-FLG-P100
specifications. This type level gauge is used for marine oil tanks,excluding
those of flash point of 60 below. Flat type level gauge allow an excellent A-TYPE (AIR VENT) B-TYPE (TANK RETURN) C-TYPE (SELF-CLOSING)
observation of colorless liquid level through reflection of several parallel
grooved glass.

Gauge Body

Water space Steam/gas space

Gauge glass

Light ray Light ray

Installation
Operating principle
The principle of reflex glass is based on the difference in the refractive indices of liquid and gas or in particular
of water and steam.. The liquid column is contained within the recess of the centre-piece behind the gauge
glass which is clamped within the gauge body. If a ray of light encounters the surface of one of the 45
slanted grooves in the gas or steam space. It is reflected to the opposite surface of the groove and from there
totally reflected-back into the direction of observation.
The steam or gas space therefore appears as silver-white.
The gauge glass has prismatic right angled grooves, On the side facing the water and steam spaces. Light
rays entering from outside the gauge are either absorbed or reflected depending upon whether they enter the
water or steam space.
The light ray which encounters the surface of a groove in the liquid space is almost totally absorbed.
The liquid behind the reflex glass therefore appears back.

Model Classification and Specification SECTION A = A


Valve type Connection Design Max. Material Center to
JIS Code Type size
Upper Lower pressure temp Valve channel Glass center
Top JIS
A self- BC6 SUS304 Borosilicate
vent closing 5K20A, 3 / 150
25A 275 CAUTION
Tank self- JIS ~ Support bracket to be placed and
PA-FLG-P100 B return closing 5K20A, 3 / 150 BC6 SUS304 Borosilicate
25A 5100 spaced Max. 1000mm between upper
JIS (m/m) and lower valve.
C self self-
closing closing 5K20A, 3 / 150 BC6 SUS304 Borosilicate
25A
The level gauges shall be classified into three type A,B,C according to the shape of the upper body
Please contact our factory if other specification are required.

PANASIA CO.., LTD. 42 43


Reflex Type Glass Level Gauge

PA-RLG-P100 Series
The PANASIA reflex type level gauge consists of a sturdily constructed body, glass and cover securely fixed PA-RLG-P100
by u-bolts to endure high pressure.
This type level gauge feature serveral parallel grooves cut into the glass surface that is in contact with liquid. SELF-CLOSING
Thus the level of even transparent liquid can be clearly observed.

PA-RLG-P100 PA-TLG-P100

BALL CHECK

Model Classification and Specification


Valve typeConnection Design Material Center to
Model Type Max.
Upper Lower size pressure temp Valve Front Back center
channel channel
A Ball Ball SUS304 SUS304 SUS304
PA-RLG- ANSI 1
20 / 200
P100 150# 320
B Self Self SUS304 SUS304 SUS304 ~
2870
A Ball Ball SUS304 SUS304 SUS304 (m/m)
PA-TLG- ANSI 1
20 / 200
P100 150#
B Self Self SUS304 SUS304 SUS304

The level gauges shall be classified into three type A,B,C according to the shape of the upper body.
Please contact our factory if other specification are required.

PANASIA CO.., LTD. 44 45


Magnetic Float Type
Level Gauge

Operating principle
The measuring pipe (chamber) is connected to the tank to form a float chamber that has the same level as
the tank. A float with a built-in magnetic floats freely on the surface of the liquid and transmits its movement
in the pipe, without physical contact, to an externally mounted indicating strip (Indicator).
The indication strip is placed on the ou side of the pipe and consists of numerous magnetic flaps which are
white on one side and red on the other, As the float passes the red/white flaps, the flaps are one after the
other turned 180 around their own axis.
The flaps change from white to red with rising level and from red to white with falling level.
The magnetic level gauge is particular advantage wherever dangerous and toxic media calling for careful
level monitoring.

Features
No harms to the environment. Safety Guarantee.
No leakage to atmosphere
No maintenance costs
Easy to read.
Suitable for pressure tank
Alarm contacts.(option)
Analogue output signal, 4-20mA.(option)

Model Classification and Specification


Working condition Material
Symbol Mounting Connection Measuring Specific Accuracy
type size range Press. Temp. Gravity Chamber
Float rotor rotor columnn
PLG-65MS Max. Poly-
Side JIS 5K 25A 5 / 200 Over 0.8 +/-10m/m SUS304 SUS304 carbonate Aluminum
- - 5000mm resin
PLG-65MT JIS 5K100A Max. Poly-
- - Top 5 / 200 Over 0.85 +/-10m/m SUS304 SUS304 carbonate Aluminum
or 125A 2500mm resin
Max. Poly-
PLG-65H Side 5K 25A 50 / 300 Over 0.85 +/-10m/m SUS304 SUS304 carbonate Aluminum
2500mm resin

Level Switch Unit and Level Transmitter Specification (Option)


Contact Contact Power Material No of Nax.
Measuring working Enclo-
Description Module Output rating form Accuracy sure
source Housing Transmitter point ranger temp.
Description of model Level Reed Dry 125VAC, SPST, Weather
switch unit switch contact 0.5A N/A +/-5m/m AC N/A Max.6 N/A 120 proof
SPDT
PLG-65 -
Level Transmitter Mounting Type Level Reed 4~20mA +/-% of 400m/m~ Weather
switch unit switch and DC N/A N/A DC 24V F.S AC SUS304 N/A 5000m/m 120 proof
T :Output 4~20mA MS :Side mounting resistor Two-wire
TR :Output 1 MT :Top mounting
S :Level switch H :High pressure/ temperature These switch unit and transmitter may be used for intrinsically safe application in hazard when connected through
approved zener barriers (Exia llc T4)
Please contact our factory if other specifications are required.

PANASIA CO.., LTD. 46 47


Self-Powered Contents Gauge

General PCG-150 Series


The PANASIA PCG-150 Series tank contents gauge requires no external power source for operation. FOR HIGH VISCOSITY FLUID FOR LOW VISCOSITY FLUID FOR HIGH VISCOSITY FLUID
The instrument is completely automatic and provides continuous indication of tank contents without the aid (PCG-150V) (PCG-150S) (PCG-150F)
of batteries or hand pumps.
This gauge unit is simply composed of Diaphragm, capillary tube and dial type indicator.

Application
Generally applied to fresh water, Lub oil, Diesel oil, Heavy Model:PCG-150 Series
fuel oil and solvent gasoil and noncorrosive liquid.

Specifiation
Gauge size Dial 150, 100, 160
Mounting type Side, submersible mounting
scale of indication Height(m) & volume( )
Accuracy 1.5% of full scale
Operating temperature
range -20 to +100

Enclosure Weather proof


Overload Min, 100% of full scale
5 meters, 2 meters
Length of capillary tube
(standard), other(option)
SUBMERSIBLE TYPE CONTENT GAUGE

Operating principle
The diaphragm is affected by the hydrostatic head medium column in tank, which apply pressure to the oil
filled capillary.
The pressure applied to capillary expands bourdon tube of indicator, so that the indicator displays the level
corresponding to actual tank level.

Description of model
?? ??
?@@@@@@@@@@@@@@@@@@@@@?? ?@@@@@@@@@@@@@@@@@@@@@??

PCG -
?@@@@@@@@@@@@@@@@@@@@@? ?@@@@@@@@@@@@@@@@@@@@@?

Type of sensor connection


?@@? @@? ?@@? @@?
?@@? @@? ?@@? @@?
?@@? @@? ?@@? @@?
?@@? @@? ?@@? @@?
?@@? @@? ?@@? @@?
?@@? @@? ?@@? @@?
?@@? @@? ?@@? @@?
?@@? @@? ?@@? @@?
?@@? @@? ?@@? @@?
?@@? @@? ?@@? @@?
?@@? @@? ?@@? @@?
?@@? @@? ?@@? @@?
?@@? @@? ?@@? @@?
?@@? @@? ?@@? @@?
?@@? @@? ?@@? @@?
?@@? @@? ?@@? @@?
?@@? @@? ?@@? @@?
?@@? @@? ?@@? @@?
?@@@@@@@@@@@@@@@@@@@@@? ?@@@@@@@@@@@@@@@@@@@@@?
?@@@@@@@@@@@@@@@@@@@@@? ?@@@@@@@@@@@@@@@@@@@@@?
? ?

S : Socket connenction GAUGE SEAT


F : flange connection
V : lsolating valve connection

Size of Indicator
MS : 100 dial gauge
MT : 150 dial gauge
Note
Dimension H must be complied with because the
indicator is sensitive to its mounting position.

PANASIA CO.., LTD. 48 49


Dial Type Float Level Gauge

Operating principle PDG-150 Series


The PANASIA dial type float level gauge consists of float, measuring steel wire and indicating unit as main CASE-1 DIMENSION
components.
A float accurately follows liquid level variations in the vertical direction (horizontal movement of the float is well
restricted by guide pipe).
Vertical movement of the float is transmitted throught a measuring wire to the indicating unit, in which the
measuring wire is wound around a tape pulley kept under constant torque by constant spring.
the vertical movement is converted into rotation of the tape pulley in this way.
This rotation is transmitted through a gear system to an indicator pointer which reads the liquid level on a scale
dial of indicating unit.

Application
Generally applied to Water tank and L.O, D.O and Model : PDG-150 Series
H.F.O.tanks.
Besides, magnetic coupling type dial float level gauge
is applicable to the liquids that emits corrosive,
inflammable or poisonous gases.

CASE-2 CASE-3

Model Classification and Specification


Working condition Material
Model Mounting Measuring Indication Specific Accuracy
Type type range system gravity Temp. Press. G/G head Tape Float Guide pipe
PDG- Top(with 0~5m One-Point 0.7~1.5 AC SUS304 SUS304 N/A
150SC-T chamber) 15m/m 150 0.2 /
Direct PDG- Top(with
guide wire) 0~5m One-Point 0.7~1.5 15m/m 150 0.2 / AC SUS304 SUS304 N/A
connection 150SW-T Top(with
PDG- 0~5m One-Point 0.7~1.5 15m/m 150 0.2 / AC SUS304 SUS304 N/A
type 150SW-S guide wire)
PDG- Top(with
150SC-S chamber) 0~5m One-Point 0.7~1.5 15m/m 150 0.2 / AC SUS304 SUS304 N/A
PDG- Top 0~5m One-Point 0.65~1.5 AC SUS304 SUS316 SUS316
Magnetic 150SI-T 15m/m 150 2 /
coupling PDG- Side 0~5m One-Point 0.65~1.5 15m/m 150 2 / AC SUS304 SUS316 SUS316
type(indirect 150SI-S
type) Please contact our factory if other conditions are required

PANASIA CO.., LTD. 50 51


Float Type Level Switch

Operating principle
PANASIA magnetic float level switchs monitor and control liquid levels in open or closed tank. PM-12H PM-12H-T
A permanent magnet is part of a float which rises or falls with the changing liquid level.
This magnet repells another magnet located opposite in the switch housing. In this way it causes a snap action
contact effect. A switch unit provides on-off contacts.

Features PM-12H-E PM-12H-S


Test Device
Easy maintenance Megnet Housing
Safe operating conditions
Reliable
Float

Application
Fresh water tank, Heavy fuel oil tank. switch unit
D.O.tank, Sludge tank, Sewage tank, etc.

Technical data
?? ??
? ?
?@@@@@@@@@@@@@@@@@@@@@? ?@@@@@@@@@@@@@@@@@@@@@?
?@@@@@@@@@@@@@@@@@@@@@? ?@@@@@@@@@@@@@@@@@@@@@?

PM- 12 -
?@@? @@? ?@@? @@?
?@@? @@? ?@@? @@?
?@@? @@? ?@@? @@?
?@@? @@? ?@@? @@?
?@@? @@? ?@@? @@?
?@@? @@? ?@@? @@?
?@@? @@? ?@@? @@?
?@@? @@? ?@@? @@?
?@@? @@? ?@@? @@?
?@@? @@? ?@@? @@?
?@@? @@? ?@@? @@?
?@@? @@? ?@@? @@?

electrical microswitch,
?@@? @@? ?@@? @@?
?@@? @@? ?@@? @@?
?@@? @@? ?@@? @@?
?@@? @@? ?@@? @@?
?@@? @@? ?@@? @@?
?@@? @@? ?@@? @@?
?@@@@@@@@@@@@@@@@@@@@@? ?@@@@@@@@@@@@@@@@@@@@@?
?@@@@@@@@@@@@@@@@@@@@@?? ?@@@@@@@@@@@@@@@@@@@@@??

Contact
change contact, SPDT, DPDT
Option
Switch rating 250V AC, 3A T : Test Device PM-12H-D PM-12H-C
Liquid density min. 0.7kg/d C : Cranked
E : Explosion Proof
20mm height at 0.9kg/d S : Submersible
Switch hysteresis
specific weight D : Differential
Ambient temperature -30 to +70
H : Horizontal mounting
Medium temperature -25 to +135 V : vertical Mounting
3kg/ (standard),
Rated Pressure
up to 12kg/ (option)
Installation horizontal
Protection of Switch housing IP 56, IP 68(option)
Float material sus 316L A(ROD LENGTh) : MAX.500MM
Flange, housing SUS 304, ALDC 8 B(DIFFERENTIAL) : MAX.300MM

PANASIA CO.., LTD. 52 53


Float Type Level Switch

Operating principle
PANASIA magnetic float level switchs monitor and control liquid PM-12V PM-12V-T
levels in open or closed tank. A permanent magnet is part of a float
which rises or falls with the changing liquid level.
This magnet repells another magnet located opposite in the switch
housing. In this way it causes a snap action contact effect.
A switch unit provides on-off contacts.

Features
Easy maintenance
Safed operating conditions
Reliable
Housing

Application Switch Unit PM-12V-E PM-12V-S


Fresh water tank, Heavy fuel oil tank.
Magent
D.O.tank, Sludge tank, Sewage tank, etc.
?? ??
? ?
?@@@@@@@@@@@@@@@@@@@@@? ?@@@@@@@@@@@@@@@@@@@@@?

PM- 12 -
?@@@@@@@@@@@@@@@@@@@@@? ?@@@@@@@@@@@@@@@@@@@@@?
?@@? @@? ?@@? @@?

Option
?@@? @@? ?@@? @@?
?@@? @@? ?@@? @@?
?@@? @@? ?@@? @@?
?@@? @@? ?@@? @@?
?@@? @@? ?@@? @@?
?@@? @@? ?@@? @@?
?@@? @@? ?@@? @@?
?@@? @@? ?@@? @@?
?@@? @@? ?@@? @@?
?@@? @@? ?@@? @@?
?@@? @@? ?@@? @@?
?@@? @@? ?@@? @@?
?@@? @@? ?@@? @@?
?@@? @@? ?@@? @@?
?@@? @@? ?@@? @@?
?@@? @@? ?@@? @@?
?@@? @@? ?@@? @@?
?@@@@@@@@@@@@@@@@@@@@@? ?@@@@@@@@@@@@@@@@@@@@@?
?@@@@@@@@@@@@@@@@@@@@@? ?@@@@@@@@@@@@@@@@@@@@@?
? ?

T : Test Device
C : Cranked
E : Explosion Proof Float
S : Submersible
D : Differential
H : Horizontal mounting
V : vertical Mounting

Technical data PM-12V-D


electrical microswitch, 3kg/ (standard),
Contact Rated Pressure
change contact, SPDT up to 12kg/ (option)
Switch rating 250V AC ~3A Medium temperature -25 to +135
Liquid density min. 0.7kg/d Installation horizontal
20mm height at 0.9kg/d Protection of Switch housing IP 56, IP 68(option)
Switch hysteresis
specific weight Float material SUS 316L
Ambient temperature -30 to +70 Flange, housing SUS 304, ALDC 8

PANASIA CO.., LTD. 54 55


Displacement Type
Level Switch

Operating principle
Operation is based upon a buoyancy principle whereby a spring is loaded with weighted displacers which are PM - 90-1 PM - 90-2
heavier than the liquid.
Immersion of the displacers in the liquid results in a buoyancy force change, which moves the spring upward. (VIEW A)
Since the spring moves only when the level moves on a displacer, Spring movement is always a small (VIEW A)
fraction of the level travel between displacers. A magnetic sleeve is connected to the spring and operates
within a non-magnetic barrier tube. Spring movement causes the magnetic sleeve to attract a pivoted
magnet, actuating a switch located outside the barrier tube.
Switch set points are achieved by moving displacer modules up or down the displacer wire/rod.

(OPERATING SIGNAL)

Description of model (OPERATING SIGNAL)

?? ??
? ?
?@@@@@@@@@@@@@@@@@@@@@? ?@@@@@@@@@@@@@@@@@@@@@?
?@@@@@@@@@@@@@@@@@@@@@? ?@@@@@@@@@@@@@@@@@@@@@?

PM - 90 -
?@@? @@? ?@@? @@?
?@@? @@? ?@@? @@?
?@@? @@? ?@@? @@?
?@@? @@? ?@@? @@?
?@@? @@? ?@@? @@?
?@@? @@? ?@@? @@?
?@@? @@? ?@@? @@?
?@@? @@? ?@@? @@?
?@@? @@? ?@@? @@?
?@@? @@? ?@@? @@?
?@@? @@? ?@@? @@?
?@@? @@? ?@@? @@?
?@@? @@? ?@@? @@?
?@@? @@? ?@@? @@?
?@@? @@? ?@@? @@?
?@@? @@? ?@@? @@?
?@@? @@? ?@@? @@?
?@@? @@? ?@@? @@?
?@@@@@@@@@@@@@@@@@@@@@? ?@@@@@@@@@@@@@@@@@@@@@?
?@@@@@@@@@@@@@@@@@@@@@?? ?@@@@@@@@@@@@@@@@@@@@@??

1 : Displacer
2 : Displacer
3 : Displacer

T : With Test Device


PM - 90-3

(OPERATING SIGNAL)
(VIEW A)

Specification
Max. Max. Setting Mounting Min. Switch Material
Model Application Press. Temp. accuracy flange Sp.Gr. Connection Cable contact
gland
( / ) ( ) ( ) (standard) rating Housing Flange Displacer Chamber
High or 250V SS400 SUS304 SS400
PM - 90 T-1 Low alarm Top 15/ 20 AC
10 180 10 0.85 AC, or 78, or
flage a,b,c IP56
or control JIS 5A SUS304 200L SUS304 MODES PM-90-1 PM-90-2 PM-90-3
High or 5K 80A 250V SS400 SUS304 SS400 Upper :30 to 50 Upper :30 to 50 Upper :30 to 50
Top 15/ 20 AC DIFFERENTIAL
PM - 90 T-2 Low alarm 10 180 10 5K 100A 0.85 flage a,b,c AC,
IP56
or 78, or
(mm) 1
or control 5AX2 SUS304 200L SUS304 Lower :30 to 50 Lower :30 to 50 Lower:200 to 4500
10K 80A
NO
High alarm 10K 100A Top 15/ 20 250V SS400 SUS304 SS400
PM - 90 T-3 10 180 10 0.85 AC, AC or
COM
/Mid. flage a,b,c 78, or NO
NC
5AX2 IP56 SUS304 200L SUS304 COM
low control NO NO1
CONTACT COM
NC
COM1
Optional informations CONFIGURATION NC
NO1 NC1
COM1
1.Special material(SUS316, SUS304) for weted parts including mounting flange, chamber is also available on NC1
NO2
request. COM2 1:Differential is the allowable range from the
NC2
2.Switch contact type : SPDT, DPDT acutating level of the switch to the reset level

PANASIA CO.., LTD. 56 57


Reed Switch Type
Float Level Switch

Operating principle
The reed switch type float level switches consist of a
magnetic float and reed switch as main components.
PR-30S-2 PR-30S-2 (with chamber)
A float equipped with permanent magnet moves up and
down with the fluid level between two stoppers and its
magnetic field actuates a hermetically sealed reed switch
incorporated in guide pipe.
The switches can be normally open, normally closed or (OPERATING SIGNAL)
change-over contacts.
The advantage of this principle;there is only one moving part,
the float.
This actuates the reed switch with its magnetic field without
causing any wear.
The reed switch is itself totally isolated from the media.
These advantages give the user safe, repeatable, accurate
and high operational reliability with low maintenance over a
long and trouble free life.

Technical data Application


Operating temperature -20 ~ 100 -Fresh water
Design pressure 5kg/ ( 50float), 8kg/ ( 65 float above) -Sea water
Process medium S.G. 0.6~1.025
-Low viscosity liquids PR-30S (with test device)
IP rating IP65, IP66, IP67, IP68
EX ia IIC T6 for PR-30EX
Protection type
and EX d IIC T6 for PR-30EXD
Switch output SPST, SPDT, DPDT(option)
1.2A 200VDC(SPST), 2.5A 250VDC
Switch rating
(SPST), 1A 200VDC(SPDT).
Float sus 316
Flange sus 304
Material
Guide pipe sus 304
Housing ALDC 8, sus 304

Description of Model
?? ?? ?? ??
? ? ? ?
?@@@@@@@@@@@@@@@@@@@@@? ?@@@@@@@@@@@@@@@@@@@@@? ?@@@@@@@@@@@@@@@@@@@@@? ?@@@@@@@@@@@@@@@@@@@@@?
?@@@@@@@@@@@@@@@@@@@@@? ?@@@@@@@@@@@@@@@@@@@@@? ?@@@@@@@@@@@@@@@@@@@@@? ?@@@@@@@@@@@@@@@@@@@@@?

PR- 30S - PR- 30EXD -


?@@? @@? ?@@? @@? ?@@? @@? ?@@? @@?

: With chamber : With chamber


?@@? @@? ?@@? @@? ?@@? @@? ?@@? @@?
?@@? @@? ?@@? @@? ?@@? @@? ?@@? @@?

C C
?@@? @@? ?@@? @@? ?@@? @@? ?@@? @@?
?@@? @@? ?@@? @@? ?@@? @@? ?@@? @@?
?@@? @@? ?@@? @@? ?@@? @@? ?@@? @@?
?@@? @@? ?@@? @@? ?@@? @@? ?@@? @@?
?@@? @@? ?@@? @@? ?@@? @@? ?@@? @@?
?@@? @@? ?@@? @@? ?@@? @@? ?@@? @@?
?@@? @@? ?@@? @@? ?@@? @@? ?@@? @@?
?@@? @@? ?@@? @@? ?@@? @@? ?@@? @@?
?@@? @@? ?@@? @@? ?@@? @@? ?@@? @@?
?@@? @@? ?@@? @@? ?@@? @@? ?@@? @@?
?@@? @@? ?@@? @@? ?@@? @@? ?@@? @@?
?@@? @@? ?@@? @@? ?@@? @@? ?@@? @@?
?@@? @@? ?@@? @@? ?@@? @@? ?@@? @@?
?@@? @@? ?@@? @@? ?@@? @@? ?@@? @@?
?@@? @@? ?@@? @@? ?@@? @@? ?@@? @@?
?@@@@@@@@@@@@@@@@@@@@@? ?@@@@@@@@@@@@@@@@@@@@@? ?@@@@@@@@@@@@@@@@@@@@@? ?@@@@@@@@@@@@@@@@@@@@@?
?@@@@@@@@@@@@@@@@@@@@@?? ?@@@@@@@@@@@@@@@@@@@@@?? ?@@@@@@@@@@@@@@@@@@@@@?? ?@@@@@@@@@@@@@@@@@@@@@??

N : No housing N : No housing
S : Submergible type S : Submergible type
CONTACT TYPE : SPDT
I : Interface Detector I : Interface Detector
All switches have three electric connections(black, blue,red)
Q Ty of float Q Ty of float The black wire is the common pole for both switching
1 : 1 Float 1 : 1 Float functions (black contact and make contact)
2 : 2 Float 2 : 2 Float CONTACT TYPE : DPDT
3 : 3 Float 3 : 3 Float This switch has two(2) SPDTcontact which is same as above.

PANASIA CO.., LTD. 58 59


Reed Switch Type
Float Level Switch

Contact Protection Requirements


When switching inductive loads such as relays, solenoids and transformers, reed switch contents require protection in order
PR-30EXD-1 PR-30S-1N PR-30S-2N to ensure long, dependable life. when current is interruped, the inductance or electrical inertia of the load generates a large
frequency voltage, which appears across the switch contacts. If the voltage is large enough, it can break down the medium
in the gap between them, making a conductive path. this phenomenon, called arcing is the spark you see.
Arcing can cause the contacts to burn, weld together or stick; thus, giving unreliable performance.
The purpose of protection circuits is to prevent arcing, by shorting this voltage through an alternate path.

Recommended Protection
D.C.
A 1N4004 diode(or equivalent) connected cathode-to-positive, as shown in Figure 1, is recommended.
The diode does not conduct when the load is energized, but conduts and shorts out the generated voltage when the switch
opens. The generated voltage always acts in series with the applied voltage.
A.C.
A resistor and capacitor, connected in parallel with the switch, as shown in Figure 2, is recommended. The capacitor is a
hight impedance to 60hertz, but is essentially a short circuit high prequencies of generated voltages.
Transient suppressors or varistors may also be used to dissipate the transient and protect the switch contacts. For
130VAC rated devices, the following table may be used for selection.

Flgure 1 Drain the Load


D.C Contact
Protection
(Drain the load)
PR-30S-1C (With chamber /IP67)

Flgure 2 Protection switch


A.C Contact
Protection
(Protect the s/w)

PANASIA CO.., LTD. 60 61


Electric Indicator Digital Indicator

Electric Indicator Bargraph Type


Specifications Specifications
Model PAI-100A Model PAI-4000(Vertical type)
Size 110X110 Square Accuracy 1% of F.S
Mounting method Panel front mounting Scale %Display dual mode.(level & volume)
Input DC 4~20mA Height %Display
Internal resistance 1.5 Volume Max. 16 Gradient %Display
Input A) DC 4~20mA(1-5V) or variable resistance
Accuracy 1.5% F.SAT 20 B) RS-485
Measuring range 0~100%(Standard) Digit 4Digit
Indicating angle 250deg. Output Alarm contact, RS485
Weight 450g Alarm point 2point, 4point (option)
Operating temperature 0 to +40 HH Dry contact normal open or close (option)
Color Black H Dry contact normal open or close
Application Panel and local gauge box L Dry contact normal open or close
LL Dry contact normal open or close (option)
Material ABS
Specifications Power DC24V, 6W(MAX.)
Model SK-130-C Temperature 0 ~50
Weight 1.0kg
Size 30 X 100
Mounting method Panel front mounting
Input DC 4~20mA Digital Indicator Specifications
Accuracy 1.0% Input Signal DC 4~20mA
Scale length 100mm Range -0.1~+0.3bar(Free Scale)
Case material Resin Power Supply DC 24V
Weight Approx. 1.3kg Accuracy DISPLAY ONLY(SENSOSR : 0.3% of F.S)
Ambient Temp -0 ~50
On-alarm type, offalarm Type Model
Contact ESDB4
available for special specification Weight 250g
Finish Color Black or white Setting Press High press : +0.22 bar, Low press : -0.05 bar
Application Panel and local gauge box

Dimension Dimension

PANASIA CO.., LTD. 62 63


Class Approvals World Wide Service Network

Maintenace / Parts Supply / Repaire / Technical Support


Classification CLASS
Society
Products KRS ABS BV DNV LRS NK GL RINA CCS

RADAR BEAM TYPE


CARGO MONITORING SYSTEM

MAGNETIC FLOAT TYPE


CARGO MONITORING SYSTEM

HIGH & OVERFILL


ALARM SYSTEM

VALVE REMOTE
CONTROL SYSTEM

AIR PURGE TYPE /


ELECTRIC PNEUMATIC TYPE
LEVEL GAUGING SYSTEM
AMERICA EUROPE MIDDLE EAST ASIA
New Jersey RY, Denmark Dubai U.A.E Busan, Korea
ELECTRIC PRESSURE TYPE
LEVEL TRANSMITTER
Houston, Taxas Rotterdam, The Netherlands Oman Nagasaki, Japan
Rio De Janeiro, Brazil Surrey, England Dalian, China
Genova, Italy Shanghai, China
Piraeus, Greece Guangzhou, China
WATER INGRESS ALARM Istanbul, Turkey Hanoi, Vietnam
SYSTEM
Lisbon, Portugal Kuala Lumpur, Malaysia

>>
Limmasol, Cyprus Singapore
LEVEL GAUGE Vladivostok, Russia Jakarta, Indonesia
-Self power content gauge Kaohsiung, Taiwan
-Flat type glass level gauge
Cochin, India
-Magnetic float type level gauge

LEVEL SWITCHES
-PM-12 Series
-PM-90 Series
http://www.worldpanasia.com
-PR-30 Series

PANASIA CO.., LTD. 64 65

S-ar putea să vă placă și