GRUNDFOS DATA BOOKLET

CR5-18 A-A-A-E-HQQE 3x400D 50HZ


Grundfos Pump 96513369

Thank you for your interest in our products


Please contact us for more information, or visit our website
http://www.lenntech.com/grundfos/CRFAM/96513369/CR-5-18-A-A-A-E-HQQE.html

info@lenntech.com
tel. +31-15-261.09.00
fax. +31-15-261.62.89

BE > THINK > INNOVATE


Company name: Lenntech BV - lenntech.com
Created by: info@lenntech.com
Phone: +31 15 2610900
Fax: +31 15 2616289
Date: -
Position Qty. Description
1 CR 5-18 A-A-A-E-HQQE

Note! Product picture may differ from actual product


Product No.: 96513369

Vertical, multistage centrifugal pump with suction and discharge ports on same the level (in-line)
enabling installation in a horizontal one-pipe system. The pump head and base are in cast iron all
other wetted parts are in stainless steel. A cartridge shaft seal ensures high reliability, safe handling
and easy service and access. Power transmission is via a split coupling. Pipework connection is via
oval flanges with internal Rp threads.
The pump is fitted with a 3-phase, fan-cooled asynchronous motor.

Further product details


The product carries the Grundfos Blueflux label. It represents the best from Grundfos within
energy-efficient motors and frequency converters. Grundfos Blueflux solutions either meet or
exceed legislative requirements such as the EuP IE3 grade.

Steel, cast iron and aluminium components have an epoxy-based coating made in a cathodic
electro-deposition (CED) process. CED is a high-quality dip-painting process where an electrical
field around the products ensures deposition of paint particles as a thin, well-controlled layer on the
surface. An integral part of the process is a pretreatment. The entire process consists of these
elements:
1) Alkaline-based cleaning.
2) Zinc phosphating.
3) Cathodic electro-deposition.
4) Curing to a dry film thickness 18-22 my m.
The colour code for the finished product is NCS 9000/RAL 9005.

Pump
A standard split coupling connects the pump and motor shaft. It is enclosed in the pump head/motor
stool by means of two coupling guards.

The pump head, pump head cover and flange for motor mounting is made in one piece. The pump
head has a combined 1/2" priming plug and air vent screw.

1/9
Printed from Grundfos CAPS [2013.03.059]
Company name: Lenntech BV - lenntech.com
Created by: info@lenntech.com
Phone: +31 15 2610900
Fax: +31 15 2616289
Date: -

The pump is fitted with a balanced O-ring seal unit with rigid torque transmission system. This seal type is
assembled in a cartridge unit which makes replacement safe and easy. Due to the balancing, this seal type is
suitable for high-pressure applications. The cartridge construction also protects the pump shaft from possible
wear from a dynamic O-ring between pump shaft and shaft seal.
Primary seal:
- Rotating seal ring material: Silicon carbide (SiC)
- Stationary seat material: Silicon carbide (SiC)
This material pairing is used where higher corrosion resistance is required. The high hardness of
this material pairing offers good resistance against abrasive particles.
Secondary seal material: EPDM (ethylene-propylene rubber)
EPDM has excellent resistance to hot water. EPDM is not suitable for mineral oils.

The shaft seal is screwed into the pump head.

The chambers and impellers are made of stainless steel sheet. The chambers are provided with a
PTFE neck ring offering improved sealing and high efficiency. The impellers have smooth surface,
and the shape of the blades ensure a high efficiency.

The base is made of cast iron. The oval flanges are bolted to the base. The discharge side of the
base has a combined drain plug and bypass valve. The pump is secured to the foundation by four
bolts through the base plate.

Motor
The motor is a totally enclosed, fan-cooled motor with principal dimensions to IEC and DIN
standards. The motor is flange-mounted with tapped-hole flange (FT).
Motor mounting designation in accordance with IEC 60034-7: IM B 14 (Code I) / IM 3601 (Code II).
Electrical tolerances comply with IEC 60034.

The motor efficiency is classified as IE3 in accordance with IEC 60034-30.

The motor has thermistors (PTC sensors) in the windings in accordance with DIN 44081/DIN 44082.
The protection reacts to both slow- and quick-rising temperatures, e.g. constant overload and stalled
conditions.

2/9
Printed from Grundfos CAPS [2013.03.059]
Company name: Lenntech BV - lenntech.com
Created by: info@lenntech.com
Phone: +31 15 2610900
Fax: +31 15 2616289
Date: -

Thermal switches must be connected to an external control circuit in a way which ensures that the automatic
reset cannot cause accidents. The motors must be connected to a motor-protective circuit breaker according to
local regulations.

The motor can be connected to a variable speed drive for adjustment of pump performance to any
duty point. Grundfos CUE offers a range of variable speed drives. Please find more information in
Win-/WebCAPS.

Technical data

Liquid:
Pumped liquid: Water
Liquid temperature range: 253 .. 393 K
Liquid temp: 293 K
Density: 998.2 kg/m

Technical:
Speed for pump data: 2902 rpm
Rated flow: 5.8 m/h
Rated head: 93 m
Shaft seal: HQQE
Approvals on nameplate: CE,TR
Curve tolerance: ISO 9906:1999 Annex A

Materials:
Pump housing: Cast iron
EN-JL1030
ASTM A48-30 B
Impeller: Stainless steel
DIN W.-Nr. 1.4301
AISI 304

Installation:
Maximum ambient temperature: 333 K
Max pressure at stated temp: 16 bar / 120 C
16 bar / -20 C
Flange standard: OVAL
Pipe connection: Rp 1 1/4
Flange size for motor: FT130

Electrical data:
Motor type: 100LC
IE Efficiency class: IE3
Number of poles: 2
Rated power - P2: 3 kW
Power (P2) required by pump: 3 kW
3 kW
Mains frequency: 50 Hz
Rated voltage: 3 x 380-415 D V
Rated current: 6.3 A
Starting current: 840-920 %
Cos phi - power factor: 0,87-0,82
Rated speed: 2900-2920 rpm
Efficiency: IE3 87,1%
Motor efficiency at full load: 87,1-87,1 %
Motor efficiency at 3/4 load: 88,0-87,0 %
Motor efficiency at 1/2 load: 87,7-85,4 %

3/9
Printed from Grundfos CAPS [2013.03.059]
Company name: Lenntech BV - lenntech.com
Created by: info@lenntech.com
Phone: +31 15 2610900
Fax: +31 15 2616289
Date: -
Position Qty. Description
Enclosure class (IEC 34-5): 55 (Protect. water jets/dust)
Insulation class (IEC 85): F

Others:
Label: Grundfos Blueflux
Minimum efficiency index, MEI : 0.57
Net weight: 45.8 kg
Gross weight: 48.7 kg
Shipping volume: 0.11 m3

4/9
Printed from Grundfos CAPS [2013.03.059]
Company name: Lenntech BV - lenntech.com
Created by: info@lenntech.com
Phone: +31 15 2610900
Fax: +31 15 2616289
Date: -
96513369 CR 5-18 50 Hz
H CR 5-18, 3*400 V, 50Hz eta
[m] [%]
Pumped liquid = Water
Liquid temperature = 293 K
Density = 998.2 kg/m

130

120

110

100 100

90 90

80 80

70 70

60 60

50 50

40 40

30 30

20 20

10 10

0 0
0 0.5 1.0 1.5 2.0 2.5 3.0 3.5 4.0 4.5 5.0 5.5 6.0 6.5 7.0 7.5 8.0 8.5 Q [m/h]
P NPSH
[kW] [m]

3.0 P1 6

2.5 5
P2

2.0 4

1.5 3

1.0 2

0.5 1

0.0 0

5/9
Printed from Grundfos CAPS [2013.03.059]
Company name: Lenntech BV - lenntech.com
Created by: info@lenntech.com
Phone: +31 15 2610900
Fax: +31 15 2616289
Date: -
Description Value H CR 5-18, 3*400 V, 50Hz eta
[m] [%]
Pumped liquid = Water
Product name: CR 5-18 A-A-A-E-HQQE Liquid temperature = 293 K
130
Product No: 96513369 120 Density = 998.2 kg/m
EAN number: 5700396638485 110
100 100
Technical: 90 90
Speed for pump data: 2902 rpm 80 80
70 70
Rated flow: 5.8 m/h
60 60
Rated head: 93 m 50 50
Head max: 123 m 40 40
Impellers: 18 30 30
Shaft seal: HQQE 20 20
Approvals on nameplate: CE,TR 10 10
Curve tolerance: ISO 9906:1999 Annex A 0 0
0 1 2 3 4 5 6 7 8 Q [m/h]
Pump type: CR 5 P NPSH
Stages: 18 [kW]
P1
[m]
Pump version: A
Model: A P2
2 4

Materials: 1 2
Pump housing: Cast iron
0 0
EN-JL1030
ASTM A48-30 B

4 x 13.5
Impeller: Stainless steel

M10 x 40
Rp 1 1/4
DIN W.-Nr. 1.4301
AISI 304
Material code: A

180
220
75
Code for rubber: E

Installation: 20

Maximum ambient temperature: 333 K


22
Max pressure at stated temp: 16 bar / 120 C
16 bar / -20 C
198

100
145
160
Flange standard: OVAL
120

G 1/2

Connect code: A
Pipe connection: Rp 1 1/4 335 712
50

Flange size for motor: FT130

Liquid: THERMISTORS PTC ACCORDING TO DIN 44082


CONNECTED TO AMPLIFIER RELAY FOR CONTROL OF MAIN SUPPLY

Pumped liquid: Water IEC TP211 THERMALLY PROTECTED WHEN THE THERMISTORS ARE

Liquid temperature range: 253 .. 393 K


Liquid temp: 293 K
Density: 998.2 kg/m
+T

+T
L3

L3

Electrical data:
L2

L2

Motor type: 100LC


+T

+T
L1

L1

IE Efficiency class: IE3


+T

+T

Number of poles: 2
TO AMPLIFIER

TO AMPLIFIER

Rated power - P2: 3 kW


RELAY

RELAY

Power (P2) required by pump: 3 kW


3 kW
Mains frequency: 50 Hz
Rated voltage: 3 x 380-415 D V
Rated current: 6.3 A
Starting current: 840-920 %
Cos phi - power factor: 0,87-0,82
Rated speed: 2900-2920 rpm
Efficiency: IE3 87,1%
Motor efficiency at full load: 87,1-87,1 %
Motor efficiency at 3/4 load: 88,0-87,0 %
Motor efficiency at 1/2 load: 87,7-85,4 %
Enclosure class (IEC 34-5): 55 (Protect. water jets/dust)
Insulation class (IEC 85): F
Motor protec: PTC
Motor No: 85U15510

6/9
Printed from Grundfos CAPS [2013.03.059]
Company name: Lenntech BV - lenntech.com
Created by: info@lenntech.com
Phone: +31 15 2610900
Fax: +31 15 2616289
Date: -
Description Value

Others:
Label: Grundfos Blueflux
Minimum efficiency index, MEI : 0.57
Net weight: 45.8 kg
Gross weight: 48.7 kg
Shipping volume: 0.11 m3

7/9
Printed from Grundfos CAPS [2013.03.059]
Company name: Lenntech BV - lenntech.com
Created by: info@lenntech.com
Phone: +31 15 2610900
Fax: +31 15 2616289
Date: -
96513369 CR 5-18 50 Hz
120

198
335
712

G 1/2 Rp 1 1/4
22 M10 x 40
50

20

100 75 4 x 13.5

145 180
160 220

Note! All units are in [mm] unless others are stated.


Disclaimer: This simplified dimensional drawing does not show all details.

8/9
Printed from Grundfos CAPS [2013.03.059]
Company name: Lenntech BV - lenntech.com
Created by: info@lenntech.com
Phone: +31 15 2610900
Fax: +31 15 2616289
Date: -
96513369 CR 5-18 50 Hz

+T +T +T

CONNECTED TO AMPLIFIER RELAY FOR CONTROL OF MAIN SUPPLY


IEC TP211 THERMALLY PROTECTED WHEN THE THERMISTORS ARE
TO AMPLIFIER
RELAY
L1 L2 L3

THERMISTORS PTC ACCORDING TO DIN 44082

+T +T +T

TO AMPLIFIER
RELAY
L1 L2 L3

Note! All units are in [mm] unless others are stated.

9/9
Printed from Grundfos CAPS [2013.03.059]
Disclaimer: The information about the Grundfos pump in this document may be outdated.
Data may be subject to alterations without further notice.
Please contact us to verify the data above is still accurate/up-to-date.

All information is copyright Grundfos.


info@lenntech.com
www.lenntech.com
tel. +31-15-261.09.00
fax. +31-15-261.62.89

S-ar putea să vă placă și