Pyrotechnics
18
. SHARES
v Email

a Facebook

d Twitter

s Print

6 Share

AS PER SOLAS CH 3 REG 6.3


Distress flares
Not less than 12 rocket parachute flares, complying with the requirements of section 3.1 of the
Code, shall be carried and be stowed on or near the navigation bridge.

Additional to mentioned above 2 Buoyant smoke signals, 4 Rocket parachute & 6 Hand flares
are to be present in each of the survival craft.

FURTHER DETAILS ON PYROTECHNICS AS PER


LSA CODE:-
ROCKET PARACHUTE FLARES

(Section 3.1 of the IMO LSA Code)


The rocket parachute flare shall:
Be contained in a water-resistant casing;
Have brief instructions or diagrams clearly illustrating the use of the rocket parachute
flare printed on its casing;
Have integral means of ignition;
Be so designed as not to cause discomfort to the person holding the casing when used
in accordance with the manufacturers operating instructions.

The rocket shall, when fired vertically, reach an altitude of not less than 300 m.

At or near the top of its trajectory, the rocket shall eject a parachute
flare, which shall:
Burn with a bright red color;
Burn uniformly with an average luminous intensity of not less than 30,000 cd;
Have a burning period of not less than 40 sec;
Have a rate of descent of not more than 5 mtr/sec; and
Not damage its parachute or attachments while burning.

HAND FLARES

(Section 3.2 of the IMO LSA Code)

The hand flare shall:


Be contained in a water-resistant casing;
Have brief instructions or diagrams clearly illustrating the use of the hand flare printed on
its casing;
Have a self-contained means of ignition; and
Be so designed as not to cause discomfort to the person holding the casing and not
endanger the survival craft by burning or glowing residues when used in accordance
with the manufacturers operating instructions.

Burn with a bright red colour;


Burn uniformly with an average luminous intensity of not less than 15,000 cd;
Have a burning period of not less than 1 min; and
Continue to burn after having been immersed for a period of 10 seconds under 100 mm
of water.

BUOYANT SMOKE SIGNALS


(Section 3.3 of the IMO LSA Code)

a
d

f
k
6

The buoyant smoke signal shall:

Be contained in a water-resistant casing;


Not ignite explosively when used in accordance with the manufacturers operating
instructions
Have brief instructions or diagrams clearly illustrating the use of the buoyant smoke
signal printed on its casing.

Emit smoke of a highly visible color at a uniform rate for a period of not less than 3 min
when floating in calm water;
Not emit any flame during the entire smoke emission time;
Not be swamped in a seaway;
Continue to emit smoke when submerged in water for a period of 10 sec under 100 mm
of water.

SELF-ACTIVATING SMOKE SIGNALS 15 Minute


SOLAS requirements for self-activating smoke signals.

(Section 2.1.3 of the LSA Code)

Lifebuoy self-activating smoke signals Self-activating smoke signals


required by regulation III/7.1.3 shall:
Emit smoke of a highly visible colour at a uniform rate for a period of at least 15 min when
floating in calm water;
Not ignite explosively or emit any flame during the entire smoke emission time of the
signal;
Not be swamped in a seaway;
Continue to emit smoke when fully submerged in water for a period of at least 10 s;
Be capable of withstanding the drop test required by paragraph 2.1.1.6.

Note: 2.1.1.6 [Every self-activating smoke signal shall] be constructed to withstand a drop into
the water from the height at which it is stowed above the waterline in the lightest seagoing
condition or 30 mtr, whichever is the greater, without impairing either its operating capability
or that of its attached components;

LINE THROWING APPLIANCES:-


SOLAS requirements for line-throwing appliances.

(Section 7.1 of the LSA Code)

Every line-throwing appliance shall:

Be capable of throwing a line with reasonable


accuracy;
Include not less than four projectiles each
capable of carrying the line at least 230 mtr in
calm weather;
Include not less than four lines each having a
breaking strength of not less than 2 kN;
Have brief instructions or diagrams clearly
illustrating the use of the line-throwing
appliance. 7.1.2 The rocket, in the case of a pistol fired rocket, or the assembly, in the
case of an integral rocket and line, shall be contained in a water-resistant casing. In
addition, in the case of a pistol fired rocket, the line and rockets together with the means
of ignition shall be stowed in a container which provides protection from the weather.

MARKING ON PYROTECHNICS:-
Each [pyrotechnic device] shall be legibly marked or labelled with the following, as
appropriate:
Company name, location, and brand or style designation
Type of pyrotechnic device
Intensity in candela (for flares only)
Burning time (for flares and smoke signals only)
Use Only When Aircraft or Vessel Is Sighted. (for flares and 3-min smoke signals only)
Approved for daytime use only (for smoke signals only)
Simple operation instructions (in paragraphs or pictographs)
Expiration Date (month and year to be inserted by manufacturer not more than 42
months after date of manufacture (48 months in the case of line-throwing appliance
components containing pyrotechnic material))
Date of Manufacture (Month and year to be inserted by manufacturer)
Lot No. -
S. Coast Guard Approval No. -.

Meets SOLAS-LSA Code The expiration date, date of manufacture, and lot number must also
be marked on or clearly visible through the package in which the device is sold.

Subscribe To Our Newsletter


GET UPDATES. IT'S FREE.
Join our mailing list to receive the latest articles from our team.

Enter your email

Subscribe

And dont worry, we hate spam too! You can unsubscribe at anytime.

powered by MailMunch

You may like:


What is ALARP and why do you need to know it?
Ballast Water Management Merchant Ships
Thermal Protective Aid Requirements as per SOLAS
Man Overboard Manoeuvers you need to know to save a life

BY NAVEEN KUMAR
FILED UNDER: SAFETY
TAGGED WITH: BUOYANT, DISTRESS, FLARES, LSA, LTA, PARACHUTE, PYROTECHNICS, ROCKET, SAFETY, SMOKE

Leave a Reply
Your email address will not be published. Required fields are marked *

Comment

Name *

Email *

Website

POST COMMENT

Search this website

JOIN OUR LIST

Subscribe to our mailing list and get interesting stu and updates to your email inbox.

Enter your email

Subscribe

powered by MailMunch

KNOWLEDGEBASE

Bridge Equipment

Cargo Work

Colregs
Deck

General

Gmdss

Maritime Law

Marpol

MLC 2006

Navigation

Safety

Anti Exposure Suit

Ballast Water Management - Merchant Ships

Immersion Suit

ISM Code - All you should know about International Safety Management Code

Lifeboat - General Requirements

Lifebuoys

Liferaft - General Requirements

Man Overboard - Manoeuvers you need to know to save a life

Port State Control (PSC) - An agreed regime for the inspection of foreign ships

Portable Fire Extinguishers

Pyrotechnics

SOLAS REQUIREMENT's FOR LIFEJACKET

Thermal Protective Aid - Requirements as per SOLAS

What is ALARP and why do you need to know it?

Security

Ship Construction

Ship Handling

Ship Stability

Shippies Escape

Surveys

Tankers

POPULAR POSTS
Piping Arrangement Conventional Oil Tanker Basics
4.4K VIEWS

Stresses in Ships
3.1K VIEWS

Cargo Calculations Tanker Work


3K VIEWS

Anchor Terminology used in Shipping


2.7K VIEWS

Shallow Water Effect on Ship


2.7K VIEWS

What is VEF (Vessel Experience Factor) ?


2.3K VIEWS

Ship Stability Definitions related to Hydrostatic Particulars


2.2K VIEWS

Guidelines on Working aloft or Overside on Ships


1.9K VIEWS

What is Load on Top (LOT)?


1.5K VIEWS

Deck Water Seal Inert Gas System on Tankers


1.4K VIEWS

TRENDING ARTICLES

Thermal Protective Aid Requirements as per SOLAS

Static Electricity / Electrostatic Hazards

IMO: what it is, what it does and how it works ?

Doppler Log

What is Transverse Thrust?

Rule 24 Towing and pushing

Refrigeration Principle, Cargo and Systems

ISPS code A measure to enhance the security of Ships and Port facilities

ANNEX IV Distress Signals


Repatriation MLC 2006

SOCIAL FOLLOWERS

17.6k Total fans


6.2K 7.9K 3.5K
FANS FOLLOWERS SUBSCRIBERS

Copyright 2017 Made with by a small band of sailors Log in

S-ar putea să vă placă și