Sunteți pe pagina 1din 2

175 WATT MERCURY VAPOR

E M3811 - M3851

l\r3811 143851
EXTRUDED LOW BRIGHTNESS EXTRUDED LOW BRIGHTNESS
BAFFLE FINISHED IN 3M BAFFLE FINISHED IN 3M
NEXTEL BLACK NEXTEL BLACK

Surface Pendant
Design Square Length Design Square Length
Number Size o.A. Lamping Numbet Size o.A. Lamping
M3811 B" x 16Y2" 161/2" '175W. R40 M38s1 8" x 161/2" '175W. R40

Speclfy Voltage Required

Finish:
Construction:
Standard f inish is #3'13 Duranodic Bronze Baked
Housings are constructed of heavy gauge aluminum Enamel over chromate dip. Black, white, and satin
extruded material of corrosion resistant alloy with a aluminum are also available. See price list.
1/8" wall thickness.
Pendants are supplied six feet o.a. with stem, Ballast Type:
canopies, and alignrne nt swivels, Constant wattage core and coil high power factor
autotranslormer, easily accessible for service.
Socket and Wirlng:
Fixture is wired with 200'C. SF2 Silicone wire and Labels:
n ic kel-plated screw shell socket. Underwriters' listed, l.B.E.W.
M
87
OCOPYBIGHTOCT.1975, NL CORPORATION .1A901 BFOADWAY, CLEVELANO, OHIO 44137
Certilied Test Report No. ERL 1400
NL Corp. Recessed Downlight, Cat. No. 33l l
One GE H175RFL39-22 175W Mercury Lamp, Rated 5700 Lumens

Average Luminance Data Luminance Summary-Footlamberls


Foollamberts Angle Average FL
Angle Luminance 45 2736
'1189
0 35246 50
30 15022 55 320
40 5527 60 B4
Total Lumens
45 2736 65
I Zone Lumens Percent
50 1189 70
0-40 2B1s
55 320 75 0
0 0-60 3049
49.39
53.50
60 a4 BO
65 46 B5 0 0-90 3051 53.54
70 I
75 0
BO
! C"rtilied Test Report No. EBL l4OO
" NL Corp. Recessed Downlight, Cat. No.33ll
One GE H175RFL39-22 175w. Mercury Lamp, Rated 5700 Lumens
Coeflicients Of Utilizalion
: .20
Effective Floor Cavity Bellectance
cc 80 70 5030 100
Wall 70 50 30 10 70 50 30 t0 50 30 t0 50 30 10 50 30 l00
RCR
1 61 60 s9 .58 .60 .59 .58 .57 .57 .56 .55 .55 .54 .54 .53 .52 .52 .51
2 .59 .57 .55 .53 .58 .56 .54 .53 .54 .53 .52 .53 .52 .51 .51 .50 .50 .49
3 .57 .54 .52 .50 .56 .53 .51 .50 .52 .50 .49 .s1 .49 .44 .49 .48 .47 .47
4 .54 .51 .49 .47 .54 .51 .48 .47 .49 .48 .46 .48 .47 .46 .47 .46 .45 .44
5 .52 .49 .46 .44 .51 .48 .45 .44 .47 .45 .43 .46 .44 .43 .45 .44 .43 .42
6 .50 .46 .44 .42 -49 .46 .43 .41 .45 .43 .41 .44 .42 .41 .44 .42 .41 .40
7 .48 .44 .41 .39 .47 .43 .41 .39 .43 .40 .39 .42 .40 .39 .42 .40 .38 .38
I .46 .42 .39 .37 .45 .41 .39 .37 .41 .38 .37 .40 .38 .37 .40 .38 .36 .36
S/MH : .B 9 .44 .39 .37 .35 .43 .39 .37 .35 .39 .36 .35 .38 .36 .34 .38 .36 .34 .34
MED, SPREAD 10 .42 .37 .35 .33 .41 .37 .35 .33 .37 .34 .33 .36 .34 .33 .36 .34 .33 .32

Number of Luminaires Required for 30.0 and 70.0 FC. Candlepower Data Candlepower Summary
Light Loss Factor : .75 See Footnote Angle Candlepower Lumens Angle Average CP
-
CC, wall + FC Refleclances: 80, 50, 20 0 4170 0 4170
Work Plane Height: 2.5 Feet 5 3990 377 5 3990
10 3667 10
Room 30.0 Footcandles 70,0 Footcandles 3184 888 15 3184
15
Oimensions Height Heighl 20 2495 20 2495
8.5 10.0 13.0 16.0 8.5 10.0 13.0 16.0 25 1S76 924 25 1976
20 20 5566 12 13 14 15 30 1539 30 1539
20 30 8889 18 18 20 21 973 626 35 973
20 40 10 10 11 12 23 24 26 27 40 501 40 501
20 60 15 15 16 17 35 36 37 39 45 22A 203 45 224
90 50 90
30 20 8889 18 18 20 21 50
22 22
30 30 11 11 12 13 26 27 2a 30 55
5
31
60 5
30 40 15 15 16 16 34 35 37 38 60
22 65 2
30 60 22 22 23 24 50 52 54 56 65
0 70 0
30 B0 29 29 30 32 67 6A 71 74 70
75 00 75 0
40 20 10 10 11 12 23 24 26 27 80 0 BO 0
40 30 15 15 16 16 34 35 37 38 85 00 85 0
40 40 19 20 20 21 45 46 48 50 90 0
40 60 28 29 30 31 66 6A 70 72
40 80 38 38 39 41 88 89 92 95 Total Oulput
40 100 47 48 49 50 110 111 1'14 118 Zone Lumens Percent
60 30 22 22 23 24 50 52 54 56 0-40 2a15 49.39
60 40 28 29 30 31 66 68 70 72 0-60 3049 53.50
60 60 42 43 44 45 98 100 102
'132 135
10s 0-70 3051 53.54
60 80 57 56 58 59 133 138 0-90 3051 53.54
60 100 72 70 72 73 167 164 167 171 40-90 236 4.15
100 40 47 4a 49 50 110 111 114 118 60-90 2 .04
100 60 72 70 72 73 167 164 167 171 70-90 0 .00
100 80 s7 95 95 96 226 222 221 225 90-180 0 0.00
100 100 122 120 117 119 245 241 274 278 0-180 3051 53.54

For other light loss lactors: Tested in Accordance with IES procedures.
No. ot luminaires required: No. lrom table X.7slNew LLF Test distance exceeds 25 feet.
M
88
(c)copynrcHTocr.r975, NL coRPoRAT|oN. r4gol BFoaDWAy,cLEVELAND,oHlo44l3T

S-ar putea să vă placă și