100

2300
OPTION 1

2 x O38 U3 Tension Chains


C/w Shackles, and chain tensioner
830 300 970 970 300 830

2220
C C

3605
300
220
2725

A A

110

O 2000
100

5450
B B

2110

45
2725

220
323 220 1557 1557 220 323

2 x O38 U2 Weight Chains


ANCHOR LAYOUT
C/w Shackles, and chain tensioner
SIDE VIEW FRONT VIEW PART# 960004441
1:50
QUALITY ASSURANCE & CERTIFICATION:
For details regarding QA control, QA requirements, QA testing and QA certification please refer
to separate documents. All materials shall be supplied, if applicable, with material certificate
according to the applicable norms and requirements.
640

500

GENERAL DRAWING SHEETS UNITS:


300

8 x M64 Cast in Anchors All dimension units are expressed exclusively in metric units according the SI unit system and
derived SI units non SI units of general application (DIN 1301 Part 1:12 1993). All mentioned
dimensions are final dimensions relative to the elaboration status.
8 x M42 Cast in Anchors
TOLERANCES AND APPLICABLE NORMS:
SECTION A$A SECTION B$B SECTION C$C Unless otherwise mentioned all un tolerated rough castingdimensions are according ISO 8062
CT14:08 1998), all un tolerated machined dimensions are according ISO 2768 1 cK:11 1989).
Drawing dimensioning is generally based on DIN 406 10/11/12:12 1992).
1:50 1:50 1:50 16 x M30 Cast in Anchors .
.
.
.
.
.
.
.
. . . .
00 22/11/2011 Ruth O'Hara First Issue
01 04$01$2012 Ruth O'Hara Change to panel and chains
REV: DATE DRAWN: REMARKS:
RATED PERFORMANCE DATA (RPD) DATE SIGN PROJECTION METHOD
O32 U3 Shear Chains (Upper and Lower) DRAWN BY: . ruthohara
All performace data is for one fender unit
2000

C/w Shackles, chain tensioner CHECK BY:


Fender QCL-2000 (C1 +1) and shear chain plate SEEN BY:
Performance Rated Maximum CUSTOMER:
Muelle de Carbon, Isla Riesco, Chile
Energy 2164 kJ 2291 kJ QCL2000 (C1+1) DRAWING CONTENT
Reaction 2454 kN 2605 kN
1050 mm 1100 mm
Option 1 $ QCL2000H (C1+1)
250

Deflection Tel: ++ / 31 / (0)497 / 53.22.22 Revision:


52.5 % 55 % SHEET 1 OF 2
Fax:: ++ / 31 / (0)497 / 53.22.23
P.O. Box 61 01
5520 AB Eersel, The Netherlands Drawing file:
TOP VIEW
1. Standard manufacturing tolerance of 10% applies unless otherwise agreed. A3 960004441
50 PE

INFO@QUAYQUIP.COM WWW.QUAYQUIP.COM
2. All values are RPD datum as defined by PIANC / ASTM at +23C (73F), 0.15m/s 2300x5450 Fender panel QuayQuip, QQ and the QuayQuip logo are registered trademarks of QuayQuip BV. All other trademarks are property of there Project No.:
with 50 thk UHMW$PE
4073
respectively owners. All information, texts, calculations and drawings remain property of QuayQuip BV. They may only be used
(6in/s) initial impact speed and 0 compression angle. by third party with distinct permission in writing from QuayQuip BV.
2008$2012 QUAYQUIP BV. ALL RIGHTS RESERVED. Errors and omissions excepted
PRINTED 04 01 2012 15:28