AJIT JOSHI
Divisional Head (Analytics)
Forbes Marshall

17th Oct 2008, Chennai 1


Advantages of Automation
Continuous measurement gives
repetitive results
Stable Control over Narrow band of
operation
Optimize use of Electrical energy and
Chemicals.
Sample measured is a true
representative of process
Know the status at any stage
Plant can run with less manpower
Centralized information, possible to
analyze
17th Oct 2008, Chennai
Waste water treatment plant
Possible Instrumentation at
Inlet of ETP:
pH/TDS/Sulphide/Oil&Grease/
Ammonium/SS
Flow

Equalization Tank:
pH/Flow

Neutralization Tank:
pH Control
Points to note while
selecting
pH Sensor
Solid Reference electrolyte

Measuring Glass suitable for


harsh chemicals

Sensor with integral temperature


sensor
Points to note while
selecting
Turbidity/Suspended
Solids
Self cleaning of measuring window
Measuring Principle free from
reflection of IR rays and visible
light
Measurement free of flow rate
Mounting options of flow through
chambers or dip type holder
FULL BORE MAGNETIC FLOW
METERS
Why MAGMETER??
liner
tube
NO Obstruction inside:Nothing
can be caught!!
Same Dia as mating pipe:No
Additional pressure drop!!

NO Moving Parts: No wear &


tear!!
Electrode With Different Liners we
achieve
High Chemical resistance
Long Lifetime even with
aggressive,abrasive slurries

Also well proven for


Measurement of sludges
Dosing of flocculants


17th Oct 2008, Chennai
INSTALLATION
CONDITIONS
INSTALLATION CONDITIONS
Analysers For Waste Water

Primary Clarifier :
Sludge Level

Clarifier Overflow:
Turbidity/TOC

Aeration Tank:
DO Control/pH/MLSS
Analysers For Waste Water
Secondary Clarifier :
Sludge Level

Treated Effluent:
pH/Sulphide/TOC/Oil &
Grease/Phenol/Turbidity/
Ammonia/Nitrate/Nitrite/Phosphorous
Sludge Level Control
Controlling a Desludgeing pump with Timer is not as
good as Sludge Level Blanket Control
Heavy sludge loading can overwhelm the timer
controlled desludging pump allowing the sludge to slip
from top while the blanket level controller maintains the
sludge level within high & low set points.
Sludge loading varies widely from
Day /Night
Weekdays
Summer / winter
Control Desludge pumps by sludge blanket Control NOT
BY Timers
SLUDGE BLANKET
LEVEL CONTROL

VERSUS

TIMER BASED

BLANKET LEVEL

DESLUDGING
Possible Instrumentation at

Clarifier Overflow:
Turbidity

Aeration Tank:
DO Control/pH/MLSS
Dissolved Oxygen
Critical parameter for
measurement and control
Should have fast response
time
Less & Quick Maintenance
Measurement independent
of Flow rate.
Unaffected by Co2 &H2S
Membranes to withstand
high pressure
Luminscence DO Sensor
Luminophore in initial state

Absorbing photon

Luminophore in excited state

O2 absent O2 present

O2
Colliding with O2

Energy is
transferred to
O2 O2 molecule
Luminophore emits
red light when in (quenching)
excited state
Luminophore returns to
initial state
D.O BASED AUTOMATIC AERATION
1
SYSTEM
2 3

AIR BLOWERS
Cyclic operation
of Blowers

VFD Motor Starter

DIGITAL OUTPUTS

PID
Controller D.O Low /
Program High Alarm
4-20 mA, Analog Input
On-line D.O
Meter

Aeration Tank
BENEFITS
High Degree of process control & Efficiency
seen.

6 mg/l

Manual Control

0 mg/l

Automated D.O2
Control
Possible Instrumentation at

Secondary Clarifier :
Sludge Level/Flow

Nitrification/De Nitrification
Ammoinium/DO

Filter Backwash
Turbidity
Possible Instrumentation at

Treated Effluent:

pH/Sulphide/TOC/Oil &
Grease/Phenol/Turbidity/COD
Ammonia/Nitrate/Nitrite/Phosphorous/
Residual Chlorine/Flow
Points to note while
selecting
Special Analysers
Measuring Principle suitable for
On line use in terms of
Availability
Maintenance
Cross Reference
Measuring Principle free from
reagents or with locally available
reagents
Analyser with Auto cleaning/Auto
calibration facility
Complete Automation