Abstract-The specifications of a highly flexible controller for a three-phase McMurray inverter are defined and the construction of a suitable
controller is described. The controller is capable of operation in either the six step or pulsewidth modulation mode and incorporates safe start-up and
shut-down procedures. The operation of the controller is illustrated by a series of inverter and controller oscillograms.
INTRODUCTION
+ DC INPUT
T2R
A
c
square waveform, its high efficiency, and capability of high-frequency operation is used as the three-phase power source for the
experimental investigation of variable-speed, variable-frequency ac drives in the authors' laboratory. The inverter controller described
here provides an interface be- tween the inverter and other equipment modules such as pulsewidth modulation (PWM) controllers and
drive con- trollers. As such it accepts a standardized input pulse train and generates firing pulses for the inverter main and auxiliary
thyristors. It also ensures the safe start-up and shut-down of the inverter, is self contained with its own power supply, and is shielded
against the various and intense noise sources of a power electronics laboratory.
As befits a controller designed for use in an experimental laboratory, major design aims were flexibility, simplicity of operation,
and reliability.
y
0
u
T
p
T2y
u
T
Fig. 1. A three-phase McMurray inverter. The three phases are identi- fied as red R , yellow Y, and blue B.
capacitor charges as shown. To tum off Tl, the auxiliary thyristor TAI is fired, thus permitting C to discharge. The combination of
L and C is lightly damped so that the dis- charge of C is essentially accomplished by a half sinusoid of current. The first portion of
this current passes in the reverse direction through Tl , rapidly driving its current to zero. The excess discharge current flows through
the inverse parallel connected feedback diode Dl.
This situation, Tl carrying zero current and reverse biased by the forward drop of Dl , persists for a few tens of micro- seconds,
sufficient for Tl to recover its voltage blocking capa- bility. The other main thyristor, Tl, may then be triggered, thus connecting
the output to the de negative bus.
The operation of the commutation circuit is such that the capacitor voltage reverses to a value somewhat higher than the de
supply voltage so that it is appropriately charged for the next commutation which will tum off T2 and turn on Tl .
A McMurray inverter controller must, therefore, produce an auxiliary thyristor pulse to initiate commutation, followed, with an
appropriately adjusted delay, by a main thyristor pulse. A three-phase unit, as shown in Fig. 1, requires six auxiliary and six
main pulses appropriately spaced in time.
The matter is somewhat more complicated when the load draws a lagging current. The load current reversal lags the voltage
reversal so that the incoming main thyristor T2 only carries current momentarily, the load current almost im- mediately
transferring to its feedback diode D2. The main thyristor must be ready to carry the current at some later