WAC155 Serial Wind Transmitter


Features/Benefits
Measures the wind data at
configurable interval and
computes wind average values
over adjustable period

Communicates over 2-wire


RS-485 line with NMEA 0183
protocol (MWV, MWV query)

Input voltage range 9 - 31.5 V


enables use in both 12 V and
WAC155 converts the wind speed and direction data for use in the RS-485 bus.
24 V systems

Average power need 0.2 W,


including the sensors
Vaisala Serial Wind Transmitter the cable. The allowable transmitter
WAC155 converts the digital data distance depends on the wire gauge Superior protection against
lightning surges allows for
supplied by the Vaisala WA15 and of the cable, and is typically several
installation to high towers
WA25 series wind sensors into hundreds of meters. It should be
standard data messages for use in the noted that the peak operating current Marine use can be enabled,
with over 500 VAC isolation
RS-485 bus. The WAC155 transmitter can reach to 30 mA, even in Power-
from system to frame
consists of a component board in save mode.
a junction box and a crossarm for Sensor heating control with
adjustable temperature limits
mounting the wind sensors. Flexible Communications
WAC155 communicates with the host Wind data is provided in standard Auto-detection of sensor
failure and system error
system over 2-wire RS-485 line. The NMEA messages. In addition,
standard sensor connections are for a service connection is available for
WA15 or WA25 series anemometers configuration and status information.
and wind vanes.
In the same RS-485 bus, there may an incorrect system voltage level,
Long Distance Operation be one or more transmitters. When absence or failure of a wind sensor,
WAC155 is alone in the bus, it can or system memory error. The cause
Only a 4-wire cable is required for the
work in Auto-transmit mode, sending of error is shown in a special Error
line between WAC155 and the host.
data in pre-configured intervals. message.
One wire pair provides the operating
When more devices are involved, the
power. The other pair is for the serial
host must control the data transit by Optional Heating Power
line. For long distances, the RS-485
polling one device at a time with an WAC155 also provides the sensors
line terminator can be activated with
NMEA query. Each transmitter has a for throughput and control of
the onboard jumper plug.
configurable ID for device addressing. heating power. The heating power
WAC155 accepts 9 to 31.5 VDC as input connection, if required, calls for an
power, from which it also generates Self-Diagnostics extra pair of wires. Since a sensor
operating power for the sensors. typically requires 0.5 A current
When the service connection is
The total average current consumed for heating, the power is most
open or the system has been started
in Power-save mode is less than 10 conveniently supplied from a local
recently, the onboard indicator LED
mA. This, along with the good line power source. By default WAC155
flashes red when any error condition
transient protection, allows for remote switches heating on in temperatures
is active.
supply of the operating power. below +4 C (user adjustable).
During an error condition also NMEA
A 20 to 30 V supply is recommended messages carry an Invalid Data
for remote power. This is to minimize flag. The error flag can result from
the current and the voltage drop in
Technical Data
Performance Signal Inputs and Outputs
Measurement range: Signal input:
Speed 0 75 m/s From wind vane 6-bit GRAY code (0.5/10.5 V)
Direction 0 360 From anemometer 0 750 Hz sq. wave (0.5/10.5 V)
Measurement frequency: Data transmission i/o:
Speed 4 Hz Type 2-wire, half-duplex RS-485
Direction 32 Hz Rate & frame, default 9600, 8N1
Averaging interval 0.25 5 s (default 3 s) Rate & frame, adj. range 300 19200, 7/8, O/E/N, 1/2
Updating interval 0.25 s Message protocol NMEA 0183 / MWV, MWV query
Resolution:
Speed 0.1 m/s Operating Conditions
Direction 2.0 (by averaging the 8 samples Operating temperature -55 +60 C
in each 0.25 s period) Storage temperature -60 +70 C
Humidity 0 100 %RH
Power Inputs and Outputs
Input operating voltage 9 31.5 VDC Dimensions and Materials
Input operating current at 24V: Dimensions:
Power-save enabled 7 mA (incl. both sensors) Junction box (w h d) 127 110 58 mm
Power-save disabled 37 mA (incl. both sensors) Crossarm + Junction box (w x h x d) 887 x 165 x 157 mm
Heating control, WA15 On at 3 C / Off at 5 C (adjustable) Weight 1.5 kg
Heating voltage, WA15: Ingress protection IP65
Parallel connection 16 ... 24 VDC or VACrms Mounting To 60 mm pole mast
Series connection 32 .... 48 VDC or 32 .... 43 VACrms Materials Aluminum
Heating current, WA15:
Parallel connection 1.0 A at 20 V (incl. both sensors)
Series connection 0.5 A at 40 V (incl. both sensors)
Heating for WA25 Passed by w. expansion connector Wind Vane
Anemometer D+ RED
HTNG LGN
BLK SPARE
GND BLU
WHT HTNG WAC155
G5 GRN
E
F D YEL HTNG D C B
X1 X2 X3 G4 YEL J
A C GRN Fout E A
B G3 WHT K
BLU GND 12345 1 2 3 4 5 6 7 8 9 10 F G H
G2 VIO
F
F+
GND
HT1
HTC

HTC
HT2
GND
D+
G5
G4
G3
G2
G1
G0

RED F+
G1 ORN
G0 PNK
HTNG GRY

Cable ZZ45036 Cable ZZ45037

Please contact us at Ref. B210672EN-A Vaisala 2013


This material is subject to copyright protection, with all
www.vaisala.com/requestinfo copyrights retained by Vaisala and its individual partners. All
rights reserved. Any logos and/or product names are trademarks
of Vaisala or its individual partners. The reproduction, transfer,
distribution or storage of information contained in this brochure
in any form without the prior written consent of Vaisala is strictly

www.vaisala.com Scan the code for


more information
prohibited. All specifications technical included are subject
to change without notice.