Creative design: dual-light source of halogen and LED

Provide shadow-free illumination and true color rendition, feature high intensities up to 160,000 Lux
High optical performance, security, stability, suitable for various clinical requirements in surgeries

OL2500 Technical Speci cations

OL2570 OL2550

Diameter of Light Head (mm) 700 500

Illumination (Lux) 160000 120000

Color Temperature (K) 4300 4300

Color Rendering Index (Ra, %) 95% 95%

Diameter of Light Spot (D10, mm) 120-300 120-300

Illumination Depth (mm) 1400 1400

Illumination of Background LED Lights (Lux) 30 30

Halogen Lamps Service Life (hour) 1000h

LED Lamps Service Life (hour) 30000h

10 Level Illumination Adjustment 30%-100%

Purelit OL2500
R

Surgical Light
Marketing by:
OneMed Healthcare
Beijing Aeonmed Co.,Ltd. www.onemed.co.id
Purelit OL2500 Surgical Light

Dual-light Source Design


Continuous Lighting Operation Aerodynamic Design
Innovative design combines halogen lamps and LED lamps
Light beam with 300 mm diameter of light spot (maximum) and up to 1400mm Equipped with two group halogen bulbs, one Meeting laminar ow requirement, streamlined light
illumination depth meet lighting demand in large wounds and deep surgery in operation and the other back-up head design ensures clean air delivery to surgical
Independent power-on/power-off of halogen lamps and LED lamps Switch to the back-up bulbs automatically if wound smoothly
LED lamps work independeutly for background lighting in endoscopic surgery the bulbs in use fails, not result in any
difference on illumination or light eld center
LED lamps provide continuous lighting after
turn-on and ensure safety in surgery

1400

Convenience in Operation
After LED lamps turn-on Before LED lamps turn-on Automatic memory function, fault alarm Two detachable handles available, easy to replace
system, 10 level illumination adjustment and sterilize

Safe and Healthy Cold Lighting


With high quality blue lters, halogen lamps eliminate
almost all infrared and ultraviolet radiation while
ensuring high transmission rate
LED lamps produce little infrared and no ultraviolet
radiation
Less damage on patients tissues and cells, shorter
postoperative wound healing time

Trusted Balance System


Excellent Optical Performance
Six joint linkage, easy to move, 360 degree
Provide 4300K color temperature close to natural light, ensure accurate positioning
excellent color rendering index, assist surgeons distinguishing Ensure long time use without drifting
diseased tissues from healthy tissues

3800K 4300K 4800K

S-ar putea să vă placă și