Sunteți pe pagina 1din 56

VISION CONTROL MINI

ARCHITECTURAL
FEATURES

A primary seal made of polyisobutylene is used for its high resistance against ultraviolet rays and is combined to a
1
secondary seal made of high quality silicone.

2 The tubular profile contains a highly effective drying agent, providing a moisture-free airspace between glass panels.

The unique hollow-chambered louvers provide maximum rigidity and strength and maintain the parallel alignment of
3
the blades for utmost privacy and light control.

The 1 1/4" (31.8mm) dehydrated airspace reduces noise, providing sound attenuation superior to insulating glass
4
units with standard airspaces. 1" (25.4mm) airspace available.

All pivots, pinions, and racks are made of u.v. stabilized material to ensure dimensional stability, durability, never
5
needing lubrication.

6 Various glazing products and polycarbonates are available according to applications and project needs.

7 The rack is made of corrosion-resistant aluminum.

8 The gear housing (for crank handles, knobs and motors) is mechanically attached to the frame.

The fingertip crank handles, thumbwheels and knobs operators are made of long-lasting plastic, zinc or aluminum,
9
easy to rotate and requiring no maintenance.

5 6
3
4

R
Unicel Architectural Corp.
2155 Fernand-Lafontaine
Longueuil Qubec J4G 2J4 Canada
VC MINI 1.1
T: 800.668.1580 | 450.670.6844 F: 866.496.2628 | 450.670.7144 08-2017
E: unicel@unicelarchitectural.com www.unicelarchitectural.com
VISION CONTROL MINI
ARCHITECTURAL
OPERATOR POSITION

LOUVERS BETWEEN INSULATING GLASS FOLDABLE ZINC


MANUALLY OPERATED CRANK HANDLE
GEAR HOUSING
OPTION: ELECTRICALLY OPERATED (WHITE OR GRAY)
31.8mm
1 1/4''
A

23.1mm 12.5mm
29/32'' 1/2''

54.8mm
2 5/32''
B

AIRSPACE
25.4mm

31.8mm
ALUMINUM FINISH:

1 1/4''
STANDARD DURACRON
1''

- GLOSSY WHITE K-1285


- METALLIC GRAY K-20794

FOR OPERATORS AVAILABLE)


(NON-STANDARD LOCATION
11.5mm
* SEALANT REVEAL
7/16'' GEAR HOUSING
AT PERIMETER
FOLDABLE ZINC

VARIES
OPTIONAL OPERATORS: CRANK HANDLE
(WHITE OR GRAY)

18.2mm
3/4" (19.1mm)

23/32''
ALUMINUM KNOB
- WHITE K-1285
- GRAY K-20794
- CUSTOM COLORS
1" (25.4mm)
ALUMINUM KNOB

31/32'' (24.6mm)
ABS ANTI-LIGATURE KNOB TYPICAL DETAIL TYPICAL DETAIL
(WHITE, GRAY OR BLACK) A B

2 INCREMENTS
181.8mm

186.5mm
1 INCREMENT
177mm
6 31/32"

7 11/32"
7 5/32"

9.5mm
4.76mm

3/8''
3/16''

STANDARD HEIGHT NON-STANDARD HEIGHT NON-STANDARD HEIGHT


B1 B2 B3

REFER TO STANDARD GLASS SIZES FOR HEIGHTS ON PAGE VC MINI 1.5

R
Unicel Architectural Corp.
2155 Fernand-Lafontaine
Longueuil Qubec J4G 2J4 Canada
VC MINI 1.2.1
T: 800.668.1580 | 450.670.6844 F: 866.496.2628 | 450.670.7144 08-2017
E: unicel@unicelarchitectural.com www.unicelarchitectural.com
VISION CONTROL MINI
ARCHITECTURAL
OPERATOR POSITION

LOUVERS BETWEEN INSULATING GLASS


MANUALLY OPERATED
GEAR HOUSING
OPTION: ELECTRICALLY OPERATED
24.6mm
31/32''
A

FULL THUMBWHEEL OPERATOR


(VARIABLE DIAMETER)
- WHITE ALUMINUM

54.8mm
2 5/32''
- GRAY ALUMINUM
B

- BLACK POLYMER

23.1mm 10mm
29/32'' 13/32''

FOR OPERATORS AVAILABLE)


(NON-STANDARD LOCATION
AIRSPACE
25.4mm

24.6mm

VARIES
ALUMINUM FINISH:

31/32''

VARIES
STANDARD DURACRON
1''

- GLOSSY WHITE K-1285


- METALLIC GRAY K-20794

18.2mm
23/32''
11.5mm
7/16''
* SEALANT REVEAL
AT PERIMETER
OPTIONAL OPERATORS:

FAN-SHAPED THUMBWHEEL OPERATOR


(VARIABLE DIAMETER)
- WHITE ALUMINUM
TYPICAL DETAIL TYPICAL DETAIL
- GRAY ALUMINUM
- BLACK POLYMER
A B
7 19/32"
188.1mm

192.9mm

197.6mm
7 13/32"

7 25/32"
2 INCREMENTS
1 INCREMENT

9.5mm
4.76mm

3/8''
3/16''

STANDARD HEIGHT NON-STANDARD HEIGHT NON-STANDARD HEIGHT


B1 B2 B3

REFER TO STANDARD GLASS SIZES FOR HEIGHTS ON PAGE VC MINI 1.5

R
Unicel Architectural Corp.
2155 Fernand-Lafontaine
Longueuil Qubec J4G 2J4 Canada
VC MINI 1.2.2
T: 800.668.1580 | 450.670.6844 F: 866.496.2628 | 450.670.7144 08-2017
E: unicel@unicelarchitectural.com www.unicelarchitectural.com
VISION CONTROL MINI
ARCHITECTURAL
AIRSPACE AND
MINIMUM / MAXIMUM SIZES

- VISION CONTROL MINI GLASS PANELS ARE MADE WITH INTERLOCKING BLADES, OFFERING TOTAL PRIVACY AND OPTIMAL LIGHT CONTROL WHEN CLOSED

- GLASS SIZE LIMITATIONS AND THICKNESSES TO BE DETERMINED BY UNICEL'S ENGINEERING DEPARTMENT

- TWO AIRSPACE THICKNESSES ARE AVAILABLE: 1" AND 1 1/4" (25.4mm AND 31.8mm)

5mm 5mm
3/16'' 3/16''

22.4mm
22.4mm
7/8''

7/8''
21.2mm
21.2mm

27/32''
27/32''

25.4mm 31.8mm
1'' 1 1/4''

MAX. WIDTH
1219mm
48"

MINIMUM GLASS SIZE

MINIMUM WIDTH 3 3/4 in. = 95.3 mm

MAXIMUM GLASS SIZE

MAXIMUM AREA MAXIMUM WIDTH

4608 in.2 = 2.97 m2 48 in. = 1219 mm

* If required size is outside of feasibility range,


please contact Unicel for special arrangements.

R
Unicel Architectural Corp.
2155 Fernand-Lafontaine
Longueuil Qubec J4G 2J4 Canada
VC MINI 1.3
T: 800.668.1580 | 450.670.6844 F: 866.496.2628 | 450.670.7144 08-2017
E: unicel@unicelarchitectural.com www.unicelarchitectural.com
VISION CONTROL MINI
ARCHITECTURAL
DOUBLE PANELS

VERTICAL INNER SPACER FOR INTERMEDIATE LOUVER SUPPORT

MAXIMUM GLASS WIDTH BLADE TYPE

96" (2438mm) 3/16" (5mm)

2438mm
96"

ELEVATION

14.3mm CLEARANCE 22.2mm CLEARANCE 14.3mm


9/16'' REQUIRED 7/8'' REQUIRED 9/16''
GEAR HOUSING
1 1/4" x 2 5/32"
(31.8mm x 54.8mm)

VISION CONTROL MIDDLE INNER


MINI PANEL SPACER

DETAIL

FOLDABLE ZINC
CRANK HANDLE

R
Unicel Architectural Corp.
2155 Fernand-Lafontaine
Longueuil Qubec J4G 2J4 Canada
VC MINI 1.4
T: 800.668.1580 | 450.670.6844 F: 866.496.2628 | 450.670.7144 08-2017
E: unicel@unicelarchitectural.com www.unicelarchitectural.com
VISION CONTROL MINI
ARCHITECTURAL
HEIGHT CHART

STANDARD GLASS SIZES FOR HEIGHTS*


(FOR HORIZONTAL LOUVERS ONLY)**

#BLADES IMPERIAL (") METRIC (mm) #BLADES IMPERIAL (") METRIC (mm) #BLADES IMPERIAL (") METRIC (mm)
3 4 1/16 103.2 51 44 1/8 1120.8 99 84 3/16 2138.4
4 4 29/32 124.6 52 44 31/32 1142.2 100 85 1/32 2159.8
5 5 23/32 145.3 53 45 25/32 1162.8 101 85 27/32 2180.4
6 6 9/16 166.7 54 46 5/8 1184.3 102 86 11/16 2201.9
7 7 13/32 188.1 55 47 15/32 1205.7 103 87 17/32 2223.3
8 8 7/32 208.8 56 48 9/32 1226.3 104 88 11/32 2243.9
9 9 1/16 230.2 57 49 1/8 1247.8 105 89 3/16 2265.4
10 9 29/32 251.6 58 49 31/32 1269.2 106 90 1/32 2286.8
11 10 3/4 273.1 59 50 13/16 1290.6 107 90 7/8 2308.2
12 11 9/16 293.7 60 51 5/8 1311.3 108 91 11/16 2328.9
13 12 13/32 315.1 61 52 15/32 1332.7 109 92 17/32 2350.3
14 13 1/4 336.6 62 53 5/16 1354.1 110 93 3/8 2371.7
15 14 1/16 357.2 63 54 1/8 1374.8 111 94 3/16 2392.4
16 14 29/32 378.6 64 54 31/32 1396.2 112 95 1/32 2413.8
17 15 3/4 400.1 65 55 13/16 1417.6 113 95 7/8 2435.2
18 16 19/32 421.5 66 56 21/32 1439.1 114 96 23/32 2456.7
19 17 13/32 442.1 67 57 15/32 1459.7 115 97 17/32 2477.3
20 18 1/4 463.6 68 58 5/16 1481.1 116 98 3/8 2498.7
21 19 3/32 485.0 69 59 5/32 1502.6 117 99 7/32 2520.2
22 19 29/32 505.6 70 59 31/32 1523.2 118 100 1/32 2540.8
23 20 3/4 527.1 71 60 13/16 1544.6 119 100 7/8 2562.2
24 21 19/32 548.5 72 61 21/32 1566.1 120 101 23/32 2583.7
25 22 13/32 569.1 73 62 15/32 1586.7 121 102 17/32 2604.3
26 23 1/4 590.6 74 63 5/16 1608.1 122 103 3/8 2625.7
27 24 3/32 612.0 75 64 5/32 1629.6 123 104 7/32 2647.2
28 24 15/16 633.4 76 65 1651.0 124 105 1/16 2668.6
29 25 3/4 654.1 77 65 13/16 1671.6 125 105 7/8 2689.2
30 26 19/32 675.5 78 66 21/32 1693.1 126 106 23/32 2710.7
31 27 7/16 696.9 79 67 1/2 1714.5 127 107 9/16 2732.1
32 28 1/4 717.6 80 68 5/16 1735.1 128 108 3/8 2752.7
33 29 3/32 739.0 81 69 5/32 1756.6 129 109 7/32 2774.2
34 29 15/16 760.4 82 70 1778.0 130 110 1/16 2795.6
35 30 25/32 781.8 83 70 27/32 1799.4 131 110 29/32 2817.0
36 31 19/32 802.5 84 71 21/32 1820.1 132 111 23/32 2837.7
37 32 7/16 823.9 85 72 1/2 1841.5 133 112 9/16 2859.1
38 33 9/32 845.3 86 73 11/32 1862.9 134 113 13/32 2880.5
39 34 3/32 866.0 87 74 5/32 1883.6 135 114 7/32 2901.2
40 34 15/16 887.4 88 75 1905.0 136 115 1/16 2922.6
41 35 25/32 908.8 89 75 27/32 1926.4 137 115 29/32 2944.0
42 36 5/8 930.3 90 76 11/16 1947.9 138 116 3/4 2965.5
43 37 7/16 950.9 91 77 1/2 1968.5 139 117 9/16 2986.1
44 38 9/32 972.3 92 78 11/32 1959.9 140 118 13/32 3007.5
45 39 1/8 993.8 93 79 3/16 2011.4 141 119 1/4 3029.0
46 39 15/16 1014.4 94 80 2032.0 142 120 1/16 3049.6
47 40 25/32 1035.8 95 80 27/32 2053.4 143 120 29/32 3071.0
48 41 5/8 1057.3 96 81 11/16 2074.9 144 121 3/4 3092.5
49 42 7/16 1077.9 97 82 1/2 2095.5 145 122 19/32 3113.9
50 43 9/32 1099.3 98 83 11/32 2116.9 146 123 13/32 3134.5

*NON-STANDARD GLASS HEIGHTS ARE ALSO AVAILABLE BY ADDING SERIES OF 3/16"(4.76mm) INCREMENTS TO ANY GIVEN STANDARD HEIGHT (SEE PAGE VC MINI 1.2.1 & 1.2.2)
**FOR VERTICAL LOUVERS, THIS CHART CAN BE INTERPRETED AS STANDARD GLASS SIZES FOR WIDTHS

R
Unicel Architectural Corp.
2155 Fernand-Lafontaine
Longueuil Qubec J4G 2J4 Canada
VC MINI 1.5
T: 800.668.1580 | 450.670.6844 F: 866.496.2628 | 450.670.7144 08-2017
E: unicel@unicelarchitectural.com www.unicelarchitectural.com
VISION CONTROL MINI
ARCHITECTURAL
ACCESSORIES

EXTENSION POLE
FOR OUT-OF-REACH VISION CONTROL MINI UNITS

HEXAGONAL SOCKET

HEXAGONAL
SOCKET
VISION CONTROL
MINI PANEL
OVAL PLATE

mm
OVAL PLATE 38.4
m - 24 "
9.2m48" - 96
121

EXTENSION POLE

A A

GLASS STOPS THUMBWHEEL COVER


SCREW #6 X 3/4" (19.1mm)
25.4mm STAINLESS STEEL PHILLIPS OVAL HEAD
1" 17.5mm 81mm 17.5mm
11/16" 3 3/16" 11/16"
1 19/32"
SNAP-ON COVER
40mm

15.9mm
5/8"
19.1mm
3/4"
6mm
1/4"
44.5mm
1 3/4"

= =
12.7mm
1/2"

76.2mm
3"
28.6mm
1 1/8"

ELEVATION

HOLE(2) 9/64" (3.6mm) COUNTERSINK (HS #4)


12.7mm

3.2mm

6.4mm
1/8"
7.9mm
1/2"

1/4"
5/16"

STANDARD FINISHES* GLASS STOPS

DURACRON WHITE K-1285

DURACRON GRAY K-20794


7.9mm 7.9mm
CLEAR ANODIZED (CLASS II) 5/16" 5/16"
* OTHER FINISHES AVAILABLE UPON REQUEST. PLAN

R
Unicel Architectural Corp.
2155 Fernand-Lafontaine
Longueuil Qubec J4G 2J4 Canada
VC MINI 1.6
T: 800.668.1580 | 450.670.6844 F: 866.496.2628 | 450.670.7144 08-2017
E: unicel@unicelarchitectural.com www.unicelarchitectural.com
VISION CONTROL MINI
ARCHITECTURAL
INTERIOR WALL
HOLLOW METAL FRAME

CRANK HANDLE OPERABLE ON ONE OR BOTH SIDE(S)

FOLDABLE ZINC
CRANK HANDLE

12.7mm
1/2''

VISION CONTROL
MINI PANEL
B

50.8mm
2''
OVAL PLATE

ALUMINUM BLOCK 25.4mm


1''

6 31/32''
177mm
ALUMINUM
GLASS STOPS
BY UNICEL

28.6mm
1 1/8''
A C
STANDARD FINISHES* LOUVERS GLASS STOPS

DURACRON WHITE K-1285

12.7mm
SETTING BLOCK

1/2''
BY OTHERS
DURACRON GRAY K-20794
C
CLEAR ANODIZED (CLASS II)

* OTHER FINISHES AVAILABLE UPON REQUEST.


FOLDABLE ZINC
28.6mm
FOLDABLE ZINC FOLDABLE ZINC CRANK HANDLE
(OPTIONAL) 1 1/8''
CRANK HANDLE 1.6mm 38.1mm 1.6mm CRANK HANDLE
(OPTIONAL) 1/16'' 1 1/2'' 1/16'' 12.7mm CLEARANCE
1/2'' REQUIRED
ALUMINUM SNAP-ON
GLASS STOPS
BY UNICEL
50.8mm

VISION CONTROL GEAR


2''

MINI PANEL HOUSING


19.1mm
3/4''

ALUMINUM
1.6mm
1/16''

BLOCK
GEAR HOUSING
6 31/32''
177mm

38.1mm
1 1/2''
28.6mm
1 1/8''

1.6mm
1/16''

19.1mm
3/4''

ALUMINUM SNAP-ON
12.7mm

GLASS STOPS ALUMINUM


1/2''

BY UNICEL BLOCK
SETTING BLOCK
BY OTHERS
FOLDABLE ZINC
STEEL FRAME CRANK HANDLE
A BY OTHERS B

R
Unicel Architectural Corp.
2155 Fernand-Lafontaine
Longueuil Qubec J4G 2J4 Canada
VC MINI 2.1.1
T: 800.668.1580 | 450.670.6844 F: 866.496.2628 | 450.670.7144 08-2017
E: unicel@unicelarchitectural.com www.unicelarchitectural.com
VISION CONTROL MINI
ARCHITECTURAL
INTERIOR WALL
HOLLOW METAL FRAME

THUMBWHEEL OPERABLE ON ONE OR BOTH SIDE(S)

ACCESSIBLE ON BOTH SIDES ACCESSIBLE ON ONE SIDE


19.1mm 25.4mm 9.5mm 19.1mm 25.4mm 9.5mm
3/4'' 1'' 3/8'' 3/4'' 1'' 3/8''

B
CUT-OUT
CUT-OUT

CUT-OUT
CUT-OUT
CUT-OUT

CUT-OUT

NOTE:
ROTATION LIMITED TO
APPROX. 115 INSTEAD OF 180
188.1mm

188.1mm
A
7 13/32''

7 13/32''
115

FULL THUMBWHEEL FAN-SHAPED


OPERATOR THUMBWHEEL OPERATOR
(VARIABLE DIAMETER) (VARIABLE DIAMETER)
28.6mm
1 1/8''

LOUVERS COME DOWN


ALUMINUM SNAP-ON ALUMINUM SNAP-ON FROM OPERABLE SIDE

GLASS STOPS GLASS STOPS


BY UNICEL BY UNICEL
12.7mm

28.6mm

12.7mm
1 1/8''
1/2''

1/2''
SETTING BLOCK SETTING BLOCK
BY OTHERS BY OTHERS

STEEL FRAME STEEL FRAME


BY OTHERS BY OTHERS
A A
ALUMINUM SNAP-ON ALUMINUM SNAP-ON
GLASS STOPS 28.6mm GLASS STOPS 28.6mm
BY UNICEL 1 1/8'' BY UNICEL 1 1/8''
12.7mm CLEARANCE 12.7mm CLEARANCE
VISION CONTROL REQUIRED VISION CONTROL REQUIRED
1/2'' 1/2''
MINI PANEL MINI PANEL
19.1mm

19.1mm
3/4''

3/4''

9.5mm
3/8''
38.1mm

38.1mm
1 1/2''

1 1/2''

9.5mm 9.5mm
9.5mm

9.5mm
3/8''

3/8''

3/8'' 3/8''

FAN-SHAPED
STANDARD FINISHES* LOUVERS GLASS STOPS
FULL THUMBWHEEL OPERATOR THUMBWHEEL OPERATOR
(VARIABLE DIAMETER) DURACRON WHITE K-1285 (VARIABLE DIAMETER)

DURACRON GRAY K-20794

CLEAR ANODIZED (CLASS II)


B * OTHER FINISHES AVAILABLE UPON REQUEST.
B

R
Unicel Architectural Corp.
2155 Fernand-Lafontaine
Longueuil Qubec J4G 2J4 Canada
VC MINI 2.1.2
T: 800.668.1580 | 450.670.6844 F: 866.496.2628 | 450.670.7144 08-2017
E: unicel@unicelarchitectural.com www.unicelarchitectural.com
VISION CONTROL MINI
ARCHITECTURAL
INTERIOR WALL
HOLLOW METAL FRAMES

1.6mm 25.4mm 1.6mm 1.6mm 31.8mm 1.6mm


1/16'' 1'' 1/16'' FOLDABLE ZINC 1/16'' 1 1/4'' 1/16''
CRANK HANDLE
(REFER TO PAGE VC MINI 1.2.1
FOR OPTIONAL OPERATORS) FOLDABLE REMOVABLE
ZINC CRANK HANDLE

50.8mm
2''
A B

HEXAGONAL

50.8mm
SOCKET

2''

1 1/8'' RECOMMENDS
VISION CONTROL
1 1/8'' RECOMMENDS

6 31/32''

6 31/32''
177mm

177mm
MINI PANEL
3/8" (10mm)

28.6mm UNICEL
28.6mm UNICEL

POLYCARBONATE
ALUMINUM BLOCK
25.4mm ALUMINUM BLOCK 25.4mm

12.7mm
12.7mm

1'' 1''

1/2''
1/2''

X-RAY SHIELDING
LEAD GLASS VISION CONTROL
MINI PANEL

STEEL FRAME &


GLASS STOPS STEEL FRAME &
BY OTHERS SETTING BLOCK GLASS STOPS
SETTING BLOCK BY OTHERS
BY OTHERS
BY OTHERS
LEAD LINING
BY OTHERS

X-RAY SHIELDING POLYCARBONATE


A DETAIL - INTERIOR B DETAIL - INTERIOR

VARIES 1.6mm 25.4mm 1.6mm


1.6mm 25.4mm 1.6mm 1/16'' 1'' 1/16''
FOLDABLE ZINC
1/16'' 1'' 1/16'' CRANK HANDLE
(REFER TO PAGE VC MINI 1.2.1
FOR OPTIONAL OPERATORS)
50.8mm
2''

C D

1 1/8'' RECOMMENDS
1 1/8'' RECOMMENDS

VISION CONTROL
6 31/32''

28.6mm UNICEL
177mm

VISION CONTROL
MINI PANEL MINI PANEL
28.6mm UNICEL

ALUMINUM
25.4mm BLOCK
12.7mm

ALUMINUM BLOCK 1''


25.4mm
1/2''

PYROSTOP
12.7mm

1''
FIRE-RATED
1/2''

GLASS (45 MIN;


60 MIN; 90 MIN) STEEL FRAME &
FIRE-RATED GLASS STOPS
STEEL FRAME & BY OTHERS
GLASS STOPS
BY OTHERS SETTING BLOCK
BY OTHERS
FOLDABLE ZINC CRANK
SETTING BLOCK HANDLE (REFER TO
PAGE VC MINI 1.2.1 FOR
BY OTHERS
OPTIONAL OPERATORS)

FIRE-RATED VERTICAL LOUVERS


C DETAIL - INTERIOR D DETAIL - INTERIOR

R
Unicel Architectural Corp.
2155 Fernand-Lafontaine
Longueuil Qubec J4G 2J4 Canada
VC MINI 2.1.3
T: 800.668.1580 | 450.670.6844 F: 866.496.2628 | 450.670.7144 08-2017
E: unicel@unicelarchitectural.com www.unicelarchitectural.com
VISION CONTROL MINI
ARCHITECTURAL
INTERIOR WALL
VARIOUS FRAMES

19.1mm 25.4mm 9.5mm 19.1mm 25.4mm 9.5mm


3/4'' 1'' 3/8'' 3/4'' 1'' 3/8''

CUT-OUT
CUT-OUT

CUT-OUT
CUT-OUT
CUT-OUT
CUT-OUT

E F

FAN-SHAPED
FULL THUMBWHEEL THUMBWHEEL OPERATOR
OPERATOR (VARIABLE DIAMETER)
(VARIABLE DIAMETER)

188.1mm
188.1mm

7 13/32''
7 13/32''
VISION CONTROL VISION CONTROL
MINI PANEL

28.6mm
28.6mm

12.7mm
MINI PANEL
12.7mm

1 1/8''
1 1/8''

1/2''
1/2''

ALUMINUM FRAME &


GLASS STOPS ALUMINUM SNAP-ON
BY UNICEL GLASS STOPS
44.5mm

NOTE:
1 3/4''

BY UNICEL ROTATION LIMITED TO


SETTING BLOCK 127mm OR 152.4mm APPROX. 115 INSTEAD OF 180

BY OTHERS 5" OR 6" WOOD FRAME 115


BY OTHERS
6.4mm

SETTING BLOCK
1/4''

BY OTHERS

FRAME BY UNICEL WOOD FRAME


E DETAIL - INTERIOR F DETAIL - INTERIOR
LOUVERS COME DOWN
FROM OPERABLE SIDE

19.1mm 25.4mm 1.6mm 1.6mm 25.4mm 1.6mm FOLDABLE ZINC


3/4'' 1'' 1/16'' FOLDABLE ZINC 1/16'' 1'' 1/16'' CRANK HANDLE
CRANK HANDLE (REFER TO PAGE VC MINI 1.2.1
(REFER TO PAGE VC MINI 1.2.1 FOR OPTIONAL OPERATORS)
FOR OPTIONAL OPERATORS)

50.8mm
50.8mm

2''
2''

G H OVAL
OVAL PLATE
PLATE

VISION CONTROL
6 31/32''
177mm
6 31/32''

MINI PANEL
177mm

VISION CONTROL ALUMINUM 19.1mm 25.4mm


MINI PANEL BLOCK 3/4'' 1''
44.4mm
28.6mm

12.7mm

1 3/4''
1 1/8''
28.6mm
12.7mm

1/2''
1 1/8''

19.1mm
1/2''

ALUMINUM
3/4''
BLOCK

ALUMINUM FRAME ALUMINUM SNAP-ON


& GLASS STOPS GLASS STOPS
44.5mm

BY UNICEL
1 3/4''

BY UNICEL ALUMINUM
127mm OR 152.4mm SNAP-ON
5" OR 6" GLASS STOPS
SETTING BLOCK
SETTING BLOCK BY UNICEL
BY OTHERS
BY OTHERS
6.4mm

STEEL FRAME
1/4''

BY OTHERS
FRAME BY UNICEL RABBETED FRAME
G DETAIL - INTERIOR H DETAIL - INTERIOR

R
Unicel Architectural Corp.
2155 Fernand-Lafontaine
Longueuil Qubec J4G 2J4 Canada
VC MINI 2.1.4
T: 800.668.1580 | 450.670.6844 F: 866.496.2628 | 450.670.7144 08-2017
E: unicel@unicelarchitectural.com www.unicelarchitectural.com
VISION CONTROL MINI
ARCHITECTURAL
INTERIOR WALL
SOUND OR SMOKE BARRIER

DOUBLE FAN-SHAPED THUMBWHEELS OPERABLE ON BOTH SIDES

28.6mm 50.8mm 1.6mm 31.8mm 1.6mm


1 1/8'' 2'' 1/16'' 1 1/4'' 1/16''
19.1mm 19.1mm
3/4'' 3/4''
9.5mm
3/8''
FAN-SHAPED
THUMBWHEEL

NOTE:
ROTATION LIMITED TO
APPROX. 115 INSTEAD OF 180
B A
115

LOUVERS COME UP
VARIES

FROM OPERABLE SIDE


SOUND OR
SMOKE BARRIER
BY OTHERS
9.5mm
3/8''
9.5mm
3/8''

VISION CONTROL NOTE:
MINI PANEL ROTATION LIMITED TO
APPROX. 115 INSTEAD OF 180

115

FAN-SHAPED
THUMBWHEEL
188.1mm
7 13/32''

LOUVERS COME DOWN


FROM OPERABLE SIDE
SOUND OR
SMOKE BARRIER
28.6mm
1 1/8''

BY OTHERS

ALUMINUM SNAP-ON
GLASS STOPS
BY UNICEL
28.6mm
12.7mm

1 1/8''
1/2''

SETTING BLOCK
BY OTHERS
STEEL FRAME
BY OTHERS

DETAIL DETAIL
A B
STANDARD FINISHES* LOUVERS GLASS STOPS

DURACRON WHITE K-1285

DURACRON GRAY K-20794

CLEAR ANODIZED (CLASS II)

* OTHER FINISHES AVAILABLE UPON REQUEST.

R
Unicel Architectural Corp.
2155 Fernand-Lafontaine
Longueuil Qubec J4G 2J4 Canada
VC MINI 2.1.5
T: 800.668.1580 | 450.670.6844 F: 866.496.2628 | 450.670.7144 08-2017
E: unicel@unicelarchitectural.com www.unicelarchitectural.com
VISION CONTROL MINI
ARCHITECTURAL
INTERIOR WALL
CORNER CONFIGURATIONS

A
B
C

STANDARD FINISHES* LOUVERS GLASS STOPS BREAK METAL

DURACRON WHITE K-1285

DURACRON GRAY K-20794

CLEAR ANODIZED (CLASS II)

* OTHER FINISHES AVAILABLE UPON REQUEST.

BUTT-GLAZED WITH CORNER BREAK METAL


RIGID INSULATOR
VIEW (IF REQUIRED) 12.7mm CLEARANCE
BY OTHERS 1/2'' REQUIRED
19.1mm

VARIES
3/4''
S

OUTSIDE & INSIDE 0.080" (2mm)


IE
R
VA

THICK BREAK METAL CLOSURE


BY UNICEL
38.1mm
1 1/2''

GLAZING TAPE
BY OTHERS

VARIES
19.1mm

HOLLOW METAL
S

9.5mm
IE

3/4''

9.5mm
R

FRAME BY OTHERS
3/8''

3/8''
VA
1/ mm
.6

'
8'
28
1

VISION CONTROL ALUMINUM SNAP-ON


MINI PANEL GLASS STOPS
S
RIE BY UNICEL
VA 3M TAPE 1/16" (1.6mm) TYPICAL
BY OTHERS

FAN-SHAPED THUMBWHEEL OPERATOR


ACCESSIBLE ON ONE SIDE ONLY
(VARIABLE DIAMETER)
ALSO AVAILABLE: FULL THUMBWHEEL
OPERATOR ACCESSIBLE ON BOTH SIDES

DETAIL
A INTERIOR

R
Unicel Architectural Corp.
2155 Fernand-Lafontaine
Longueuil Qubec J4G 2J4 Canada
VC MINI 2.1.6
T: 800.668.1580 | 450.670.6844 F: 866.496.2628 | 450.670.7144 08-2017
E: unicel@unicelarchitectural.com www.unicelarchitectural.com
VISION CONTROL MINI
ARCHITECTURAL
INTERIOR WALL
CORNER CONFIGURATIONS

BUTT-GLAZED WITHOUT CORNER BREAK METAL

VISION CONTROL FOLDABLE ZINC


SILICONE JOINTS ON VIEW
MINI PANEL CRANK HANDLE
CORNER GLASS (OPTIONAL)
BY OTHERS

19.1mm
GLAZING TAPE

3/4''
CERAMIC FRIT ON
INSIDE FACE OF GLASS BY OTHERS
(COLOR TO BE DETERMINED)
GEAR HOUSING
ALUMINUM SNAP-ON

38.1mm
GLASS STOPS

1 1/2''
BY UNICEL
1/ mm
.6

'

19.1mm
8'
28

3/4''
1

12.7mm CLEARANCE
1/2'' REQUIRED
IES
VAR
1/ mm
.7
'
2'
12

HOLLOW METAL FRAME


BY OTHERS FOLDABLE ZINC
CRANK HANDLE
(REFER TO PAGE VC MINI 1.2.1
FOR OPTIONAL OPERATORS)

DETAIL
B INTERIOR

CORNER POST
VIEW 12.7mm CLEARANCE
1/2'' REQUIRED
HOLLOW METAL FRAME
9.5mm
3/8''

19.1mm

BY OTHERS
3/4''
38.1mm
1 1/2''

GLAZING TAPE
BY OTHERS
19.1mm
3/4''
9.5mm
3/8''
1/ mm
.6

'
8'
28
1

S VISION CONTROL ALUMINUM SNAP-ON


RIE MINI PANEL GLASS STOPS
VA
BY UNICEL
FULL THUMBWHEEL
OPERATOR ACCESSIBLE ON BOTH SIDES
(VARIABLE DIAMETER)
HOLLOW METAL FRAME ALSO AVAILABLE: FAN-SHAPED THUMBWHEEL
BY OTHERS OPERATOR ACCESSIBLE ON ONE SIDE

DETAIL
C INTERIOR

R
Unicel Architectural Corp.
2155 Fernand-Lafontaine
Longueuil Qubec J4G 2J4 Canada
VC MINI 2.1.7
T: 800.668.1580 | 450.670.6844 F: 866.496.2628 | 450.670.7144 08-2017
E: unicel@unicelarchitectural.com www.unicelarchitectural.com
VISION CONTROL MINI
ARCHITECTURAL
EXTERIOR WALL
VARIOUS FRAMES

STOREFRONT SYSTEM
2.8mm 31.8mm 1.6mm
1/8'' 1 1/4'' 1/16'' FOLDABLE ZINC
CRANK HANDLE
(REFER TO PAGE VC MINI 1.2.1
FOR OPTIONAL OPERATORS)

50.8mm
2''
A

6 31/32''
177mm
VISION CONTROL OVAL PLATE
MINI PANEL

ALUMINUM
33.4mm

BLOCK
1 5/16''

28.6mm
1 1/8''
UNIVERSAL

12.7mm
1/2''
L-ANGLE TRIM
BY UNICEL

ALUMINUM FRAME
BY OTHERS
SETTING BLOCK ALUMINUM SNAP-ON
GLASS STOPS
BY UNICEL

DETAIL
A EXTERIOR

OPERABLE WINDOW 31.8mm


1 1/4'' FOLDABLE ZINC
CRANK HANDLE
(REFER TO PAGE VC MINI 1.2.1
FOR OPTIONAL OPERATORS)

B
6 31/32''

OVAL PLATE
177mm

VISION CONTROL
12.7mm

MINI PANEL
1/2''

FLYSCREEN

ALUMINUM WINDOW FRAME


OPENING INWARDS
SETTING BLOCK
BY UNICEL

DETAIL
B EXTERIOR

R
Unicel Architectural Corp.
2155 Fernand-Lafontaine
Longueuil Qubec J4G 2J4 Canada
VC MINI 2.2.1
T: 800.668.1580 | 450.670.6844 F: 866.496.2628 | 450.670.7144 08-2017
E: unicel@unicelarchitectural.com www.unicelarchitectural.com
VISION CONTROL MINI
ARCHITECTURAL
EXTERIOR WALL
VARIOUS FRAMES

EXISTING CURTAIN WALL SYSTEM CURTAIN WALL ADAPTER


FOLDABLE ZINC
CRANK HANDLE
31.8mm 3.2mm
19.1mm 25.4mm 1 1/4'' 1/8''
(REFER TO PAGE VC MINI 1.2.1
3/4'' 1'' FOR OPTIONAL OPERATORS) 9.4mm
3/8''

50.8mm
2''

188.1mm
7 13/32"
105.5mm
4 5/32''

12.7mm
OVAL

1/2''
C PLATE D
FULL THUMBWHEEL

6 31/32''
177mm
OPERATOR
VISION CONTROL (VARIABLE DIAMETER)

3.2mm

50.8mm
MINI PANEL

1/8''
TRIPLE GLAZED

2''
VISION CONTROL
ALUMINUM SNAP-ON MINI PANEL
ALUMINUM
GLASS STOPS
BLOCK CURTAIN WALL ADAPTER
BY UNICEL
(FACTORY-GLAZED) 25.4mm

63.5mm
2 1/2''
1''

CURTAIN WALL CURTAIN WALL SYSTEMS


SYSTEMS BY BY UNICEL OR BY OTHERS
UNICEL OR
28.6mm
1 1/8''

BY OTHERS

SETTING BLOCK
BY OTHERS

DETAIL DETAIL
C EXTERIOR D EXTERIOR

OFFSET TRIPLE GLAZED 6mm 31.8mm 6mm


1/4'' 1 1/4'' 1/4''
6mm 19.1mm GEAR HOUSING
1/4'' 3/4'' ALUMINUM BLOCK
ROUND PLATE

ABS ANTI-LIGATURE KNOB


(REFER TO PAGE VC MINI 1.2.1
FOR OPTIONAL OPERATORS)
1/4" (6mm) TEMPERED
CLEAR GLASS
6 31/32''
177mm

1/4" (6mm) TEMPERED


CLEAR GLASS
E
1/4" (6mm) TEMPERED
CLEAR GLASS WITH
SOFT-COAT LOW-E #2
28.6mm
1 1/8''
25.4mm

ALUMINUM SNAP-ON
1''

GLASS STOPS
BY UNICEL

25.4mm CURTAIN WALL SYSTEMS


BY UNICEL OR BY OTHERS
1''

SETTING BLOCKS
BY OTHERS

DETAIL
E EXTERIOR

R
Unicel Architectural Corp.
2155 Fernand-Lafontaine
Longueuil Qubec J4G 2J4 Canada
VC MINI 2.2.2
T: 800.668.1580 | 450.670.6844 F: 866.496.2628 | 450.670.7144 08-2017
E: unicel@unicelarchitectural.com www.unicelarchitectural.com
VISION CONTROL MINI
ARCHITECTURAL
DOOR CONFIGURATION

CRANK HANDLE OPERABLE ON ONE OR BOTH SIDE(S)


VISION CONTROL MINI FURNISHED FACTORY-GLAZED IN UNICEL'S ALUMINUM TRIMS

FOLDABLE ZINC 60mm FOLDABLE ZINC


CRANK HANDLE 2 3/8'' CRANK HANDLE
FOLDABLE ZINC 31.8mm
OVAL PLATE CRANK HANDLE (WHITE OR GRAY)
1 1/4''
B (OPTIONAL)

A
VARIES

C
A

VISION CONTROL
MINI PANEL
12.7mm
1/2''

GEAR HOUSING OVAL


PLATE
58.7mm
2 5/16''

FOR OPERATORS AVAILABLE)


(NON-STANDARD LOCATION
12.7mm
1/2''
15.9mm

SETTING BLOCK
5/8''

VARIES
BY UNICEL

VISION CONTROL
FOLDABLE ZINC 30.2mm
MINI PANEL
CRANK HANDLE 12.7mm 1 3/16''
(OPTIONAL) 1/2''

OVAL PLATE GEAR HOUSING

12.7mm
DOOR

1/2''
BY OTHERS
42.9mm
1 11/16''
58.7mm
2 5/16''
31.8mm
60mm
2 3/8''

1 1/4''

B SETTING BLOCK
BY UNICEL

SNAP-ON TRIM

FOLDABLE ZINC
SETTING BLOCK C COEX GLAZING
BY OTHERS
CRANK HANDLE COEX GLAZING
(WHITE OR GRAY) SNAP-ON TRIM 44.5mm DOOR BY OTHERS
1 3/4''

OPTIONAL OPERATORS:
STANDARD FINISHES* LOUVERS DOOR TRIMS
31/32'' (24.6mm)
DURACRON WHITE K-1285 ABS ANTI-LIGATURE KNOB
(WHITE, GRAY OR BLACK)
DURACRON GRAY K-20794
- WHITE K-1285
CLEAR ANODIZED (CLASS II) 1" (25.4mm)
- GRAY K-20794
ALUMINUM KNOB
* OTHER FINISHES AVAILABLE UPON REQUEST. - CUSTOM COLORS

R
Unicel Architectural Corp.
2155 Fernand-Lafontaine
Longueuil Qubec J4G 2J4 Canada
VC MINI 3.1.1
T: 800.668.1580 | 450.670.6844 F: 866.496.2628 | 450.670.7144 08-2017
E: unicel@unicelarchitectural.com www.unicelarchitectural.com
VISION CONTROL MINI
ARCHITECTURAL
DOOR CONFIGURATION

THUMBWHEEL OPERABLE ON BOTH SIDES


VISION CONTROL MINI FURNISHED FACTORY-GLAZED IN UNICEL'S ALUMINUM TRIMS

9.5mm 60mm
THUMBWHEEL 3/8'' 2 3/8''
OPERATOR 31.8mm
1 1/4''
B CUT-OUT

63.5mm
6.5mm 6.5mm

2 1/2''
1/4'' 1/4''
A
C
188.1mm
7 13/32''

VISION CONTROL A
MINI PANEL

FULL THUMBWHEEL
OPERATOR
12.7mm
1/2''

- WHITE ALUMINUM
- GRAY ALUMINUM
- BLACK POLYMER
58.7mm
2 5/16''
12.7mm
1/2''

188.1mm
7 13/32''
15.9mm

SETTING BLOCK
5/8''

BY UNICEL

VISION CONTROL
30.2mm MINI PANEL
1 3/16''
12.7mm
1/2''
6.5mm
1/4''

DOOR
BY OTHERS
31.8mm
60mm
2 3/8''

1 1/4''

B
42.9mm
1 11/16''
58.7mm
2 5/16''

12.7mm
1/2''

SETTING BLOCK
COEX GLAZING BY UNICEL

SNAP-ON TRIM SNAP-ON TRIM


6.5mm

C
1/4''

9.5mm FULL THUMBWHEEL


3/8'' OPERATOR SETTING BLOCK COEX GLAZING
- WHITE ALUMINUM BY OTHERS
- GRAY ALUMINUM DOOR BY OTHERS
- BLACK POLYMER
44.5mm
STANDARD FINISHES* LOUVERS DOOR TRIMS 1 3/4''

DURACRON WHITE K-1285

DURACRON GRAY K-20794

CLEAR ANODIZED (CLASS II)

* OTHER FINISHES AVAILABLE UPON REQUEST.

R
Unicel Architectural Corp.
2155 Fernand-Lafontaine
Longueuil Qubec J4G 2J4 Canada
VC MINI 3.1.2
T: 800.668.1580 | 450.670.6844 F: 866.496.2628 | 450.670.7144 08-2017
E: unicel@unicelarchitectural.com www.unicelarchitectural.com
VISION CONTROL MINI
ARCHITECTURAL
DOOR CONFIGURATION

FAN-SHAPED THUMBWHEEL OPERABLE ON ONE SIDE


VISION CONTROL MINI FURNISHED FACTORY-GLAZED IN UNICEL'S ALUMINUM TRIMS

60mm 6.5mm
2 3/8'' 1/4''
31.8mm
1 1/4''
B NOTE:
ROTATION LIMITED TO
APPROX. 115 INSTEAD OF 180
C 115
A

FAN-SHAPED
THUMBWHEEL
OPERATOR LOUVERS COME DOWN
- WHITE ALUMINUM FROM OPERABLE SIDE
188.1mm
7 13/32"

- GRAY ALUMINUM
- BLACK POLYMER
STANDARD FINISHES* LOUVERS DOOR TRIMS

DURACRON WHITE K-1285


VISION CONTROL
MINI PANEL DURACRON GRAY K-20794

CLEAR ANODIZED (CLASS II)

* OTHER FINISHES AVAILABLE UPON REQUEST.


42.9mm
1 11/16''
58.7mm
2 5/16''

12.7mm
1/2''

SETTING BLOCK
BY UNICEL
SNAP-ON TRIM
CLOSED OPEN
SETTING BLOCK A COEX GLAZING
A
BY OTHERS
DOOR BY OTHERS
44.5mm
1 3/4''

FAN-SHAPED
30.2mm THUMBWHEEL OPERATOR
1 3/16''
CUT-OUT
12.7mm 9.5mm
1/2'' 3/8''
DOOR VISION CONTROL
BY OTHERS MINI PANEL
63.5mm
2 1/2''

SETTING BLOCK
BY UNICEL
31.8mm
60mm
2 3/8''

1 1/4''

B C
188.1mm
7 13/32"

COEX GLAZING
12.7mm

SNAP-ON TRIM
1/2''

FAN-SHAPED
58.7mm
2 5/16''
6.5mm

THUMBWHEEL OPERATOR
1/4''

9.5mm - WHITE ALUMINUM


12.7mm
1/2''

3/8'' - GRAY ALUMINUM


- BLACK POLYMER

R
Unicel Architectural Corp.
2155 Fernand-Lafontaine
Longueuil Qubec J4G 2J4 Canada
VC MINI 3.1.3
T: 800.668.1580 | 450.670.6844 F: 866.496.2628 | 450.670.7144 08-2017
E: unicel@unicelarchitectural.com www.unicelarchitectural.com
VISION CONTROL MINI
ARCHITECTURAL
DOOR CONFIGURATION

SUGGESTED CUSTOM DOOR TRIMS BY OTHERS

FOLDABLE ZINC 44.5mm FOLDABLE ZINC FOLDABLE ZINC 44.5mm FOLDABLE ZINC
CRANK HANDLE 1 3/4'' CRANK HANDLE CRANK HANDLE 1 3/4'' CRANK HANDLE
(OPTIONAL) (OPTIONAL)

A B

GEAR HOUSING GEAR HOUSING

6 31/32''
6 31/32''

177mm
177mm

VISION CONTROL VISION CONTROL


MINI PANEL MINI PANEL

1.6mm 1.6mm 1.6mm 1.6mm


GLAZING TAPE 1/16'' 1/16'' GLAZING TAPE 1/16'' 1/16''
BY OTHERS 12.7mm 12.7mm BY OTHERS 12.7mm 12.7mm
1/2'' 1/2'' 1/2'' 1/2''
12.7mm

12.7mm
1/2''

1/2''
28.6mm
28.6mm

1 1/8''
1 1/8''

OPTIONAL OPERATORS: OPTIONAL OPERATORS:


SETTING BLOCK SETTING BLOCK
31/32'' (24.6mm) 44.5mm BY OTHERS 31/32'' (24.6mm) 44.5mm BY OTHERS
ABS ANTI-LIGATURE KNOB 1 3/4'' ABS ANTI-LIGATURE KNOB 1 3/4''
WOOD TRIM STEEL TRIM
BY OTHERS BY OTHERS
1" (25.4mm) DETAIL DOOR BY OTHERS 1" (25.4mm) DETAIL DOOR BY OTHERS
ALUMINUM KNOB A ALUMINUM KNOB B

44.5mm 44.5mm
1 3/4'' 1 3/4''
NOTE:
ROTATION LIMITED TO
APPROX. 115 INSTEAD OF 180

115
9.5mm 9.5mm
3/8'' 3/8'' 9.5mm
3/8''
CUT-OUT
BY OTHERS
CUT-OUT

CUT-OUT

C D
LOUVERS COME DOWN
FULL THUMBWHEEL FROM OPERABLE SIDE
OPERABLE ON
BOTH SIDES CUT-OUT
BY OTHERS

FAN-SHAPED THUMBWHEEL
OPERABLE ON
188.1mm
7 13/32''

ONE SIDE ONLY


VISION CONTROL VISION CONTROL
188.1mm
7 13/32''

MINI PANEL MINI PANEL

1.6mm 1.6mm 1.6mm 1.6mm


GLAZING TAPE 1/16'' 1/16'' GLAZING TAPE 1/16'' 1/16''
BY OTHERS 12.7mm 12.7mm BY OTHERS 3.2mm 3.2mm
1/2'' 1/2'' 1/8'' 1/8''
12.7mm

12.7mm
1/2''

1/2''
28.6mm

28.6mm
1 1/8''

1 1/8''

SETTING BLOCK SETTING BLOCK


44.5mm BY OTHERS 44.5mm BY OTHERS
1 3/4'' 1 3/4''
WOOD TRIM STEEL FLAT BAR
BY OTHERS BY OTHERS
DOOR BY OTHERS DOOR BY OTHERS
DETAIL DETAIL
C D

R
Unicel Architectural Corp.
2155 Fernand-Lafontaine
Longueuil Qubec J4G 2J4 Canada
VC MINI 3.2
T: 800.668.1580 | 450.670.6844 F: 866.496.2628 | 450.670.7144 08-2017
E: unicel@unicelarchitectural.com www.unicelarchitectural.com
VISION CONTROL MINI
ARCHITECTURAL
DOOR CONFIGURATION
X-RAY SHIELDING GLASS

FAN-SHAPED THUMBWHEEL OPERABLE ON ONE SIDE


PRESSURE PLATES AND SNAP-ON COVERS AS DOOR TRIMS SENT LOOSE

9.5mm 44.5mm
FAN-SHAPED 3/8'' 1 3/4''
THUMBWHEEL

B CUT-OUT 6.4mm
BY UNICEL 1/4''

57.2mm
2 1/4''
A
C
188.1mm
7 13/32''

CUT-OUT
VISION CONTROL
MINI PANEL A
FAN-SHAPED CUT-OUT
28.6mm

THUMBWHEEL
1 1/8''

BY UNICEL
NOTE:
SETTING BLOCK ROTATION LIMITED TO
APPROX. 115 INSTEAD OF 180
BY OTHERS
115
63.5mm
2 1/2''


VISION CONTROL
12.7mm
1/2''

MINI PANEL

1/2'' (13mm) LOUVERS COME DOWN


LAMINATED X-RAY GLASS FROM OPERABLE SIDE

188.1mm
7 13/32''
1/8'' (3.2mm) ANNEALED FLOAT GLASS
0.030'' (0.8mm) CLEAR
VISION CONTROL PVB INTERLAYER
MINI PANEL
3/8'' (9mm) X-RAY GLASS
1/2'' (13mm) 2.0mm LEAD EQUIV.
LAMINATED LEAD LINING
X-RAY GLASS BY OTHERS

LEAD-LINED DOOR 1/4'' (6mm) CLEAR


BY OTHERS TEMPERED GLASS
28.6mm
1 1/8''

CONTINUOUS PVC BLOCK


44.5mm
1 3/4''

B 3/32" X 5/8" (2.4mm X 15.9mm)


BY OTHERS
63.5mm
2 1/2''

PRESSURE PLATES AND


SNAP-ON COVERS AS
DOOR TRIMS BY UNICEL C
(SENT LOOSE)
6.4mm

FAN-SHAPED SETTING BLOCK


1/4''

1/4'' (6mm) CLEAR 9.5mm


THUMBWHEEL BY OTHERS
TEMPERED GLASS 3/8''

CUT-OUT
BY UNICEL LEAD-LINED DOOR 44.5mm
BY OTHERS 1 3/4''
STANDARD FINISHES* LOUVERS DOOR TRIMS
70.5mm
DURACRON WHITE K-1285 2 25/32''

DURACRON GRAY K-20794

CLEAR ANODIZED (CLASS II)

* OTHER FINISHES AVAILABLE UPON REQUEST.

R
Unicel Architectural Corp.
2155 Fernand-Lafontaine
Longueuil Qubec J4G 2J4 Canada
VC MINI 3.3.1
T: 800.668.1580 | 450.670.6844 F: 866.496.2628 | 450.670.7144 08-2017
E: unicel@unicelarchitectural.com www.unicelarchitectural.com
VISION CONTROL MINI
ARCHITECTURAL
DOOR CONFIGURATION
X-RAY SHIELDING GLASS

ZINC CRANK HANDLE OPERABLE ON ONE SIDE


PRESSURE PLATES AND SNAP-ON COVERS AS DOOR TRIMS SENT LOOSE

44.5mm
FOLDABLE ZINC 1 3/4'' FOLDABLE ZINC
CRANK HANDLE CRANK HANDLE

A
C
GEAR HOUSING
6 31/32''
177mm

VISION CONTROL
MINI PANEL A
28.6mm
1 1/8''

SETTING BLOCK
BY OTHERS
63.5mm
2 1/2''

VISION CONTROL
12.7mm

MINI PANEL
1/2''

1/2'' (13mm)
LAMINATED X-RAY GLASS

6 31/32''
177mm
1/8'' (3.2mm) ANNEALED FLOAT GLASS


0.030'' (0.8mm) CLEAR
VISION CONTROL PVB INTERLAYER
MINI PANEL
3/8'' (9mm) X-RAY GLASS
1/2'' (13mm) LEAD LINING 2.0mm LEAD EQUIV.
LAMINATED BY OTHERS
X-RAY GLASS GEAR HOUSING
LEAD-LINED DOOR
BY OTHERS 1/4'' (6mm) CLEAR
TEMPERED GLASS
28.6mm
1 1/8''

CONTINUOUS PVC BLOCK


44.5mm
1 3/4''

B 3/32" X 5/8" (2.4mm X 15.9mm)


BY OTHERS
63.5mm
2 1/2''

PRESSURE PLATES AND


SNAP-ON COVERS AS
DOOR TRIMS BY UNICEL C
(SENT LOOSE)

SETTING BLOCK
1/4'' (6mm) CLEAR FOLDABLE ZINC BY OTHERS
TEMPERED GLASS CRANK HANDLE

LEAD-LINED DOOR 44.5mm


BY OTHERS 1 3/4''
STANDARD FINISHES* LOUVERS DOOR TRIMS
70.5mm
DURACRON WHITE K-1285 2 25/32''

DURACRON GRAY K-20794

CLEAR ANODIZED (CLASS II)

* OTHER FINISHES AVAILABLE UPON REQUEST.

R
Unicel Architectural Corp.
2155 Fernand-Lafontaine
Longueuil Qubec J4G 2J4 Canada
VC MINI 3.3.2
T: 800.668.1580 | 450.670.6844 F: 866.496.2628 | 450.670.7144 08-2017
E: unicel@unicelarchitectural.com www.unicelarchitectural.com
VISION CONTROL MINI
ARCHITECTURAL
FIRE-RATED DOOR

FAN-SHAPED THUMBWHEEL OPERABLE ON ONE SIDE


VISION CONTROL MINI FURNISHED FACTORY-GLAZED IN UNICEL'S FIRE-RATED STEEL TRIMS (20 MIN. UL / 60 MIN. BS)
MAXIMUM CUT-OUT DIMENSIONS OF ROUGH OPENING IN DOOR SLAB = 36'' X 79'' (914mm X 2007mm)

46mm 31.8mm
1 13/16'' 1 1/4''
6.7mm
1/4''
B
1/4" (6mm) CLEAR
TEMPERED GLASS
C
A 5/16'' (8mm) FIRELITE
PLUS 20 MIN.

ALUMINUM FAN-SHAPED
NOTE: THUMBWHEEL OPERATOR
ROTATION LIMITED TO
VISION CONTROL
APPROX. 115 INSTEAD OF 180
MINI PANEL
149.1mm
188.1mm
7 13/32"

5 7/8''

115
FIRE GLAZING TAPE
90 MIN. 1/16'' X 7/16''
(1.6mm X 11.1mm)

CALCIUM SILICATE
CONTINUOUS SETTING BLOCK
INTUMESCENT
18 GAUGE STEEL FRAME
LOUVERS COME DOWN MATERIAL
FROM OPERABLE SIDE BY UNICEL
73mm
2 7/8''

STANDARD FINISHES* LOUVERS DOOR TRIMS


PUNCTUAL SPOT WELDS
DURACRON WHITE K-1285

DURACRON GRAY K-20794 CONTINUOUS INTUMESCENT


MATERIAL BY OTHERS
CLEAR ANODIZED (CLASS II)
OPEN WOOD MINERAL CORE CLOSED
* OTHER FINISHES AVAILABLE UPON REQUEST. A DOOR BY OTHERS A
10/32 NF 3/8'' SCREW 44.5mm 44.5mm
1 3/4'' FIRE GLAZING TAPE 1 3/4''
54.8mm 54.8mm
BY OTHERS
2 5/32'' 2 5/32''

VISION CONTROL CONTINUOUS CUT-OUT 73mm


73mm 2 7/8''
MINI PANEL INTUMESCENT BY UNICEL
2 7/8''
MATERIAL BY UNICEL 9.5mm
3/8''
22.2mm
CONTINUOUS
INTUMESCENT ALUMINUM
7/8'' FAN-SHAPED
MATERIAL BY OTHERS
52.4mm
2 1/16''

THUMBWHEEL

C
44.5mm

54.8mm
2 5/32''
1 3/4''

B
248.4mm

188.1mm
9 25/32"

7 13/32"

CALCIUM SILICATE
SETTING BLOCK
6.7mm
1/4''

5/16'' (8mm) FIRELITE 9.5mm 18 GAUGE STEEL


73mm
2 7/8''

PLUS 20 MIN. 3/8'' FRAME

1/4" (6mm) CLEAR CUT-OUT ALUMINUM


TEMPERED GLASS BY UNICEL FAN-SHAPED THUMBWHEEL

R
Unicel Architectural Corp.
2155 Fernand-Lafontaine
Longueuil Qubec J4G 2J4 Canada
VC MINI 3.4.1
T: 800.668.1580 | 450.670.6844 F: 866.496.2628 | 450.670.7144 08-2017
E: unicel@unicelarchitectural.com www.unicelarchitectural.com
VISION CONTROL MINI
ARCHITECTURAL
FIRE-RATED DOOR

ZINC CRANK HANDLE OPERABLE ON ONE SIDE


VISION CONTROL MINI FURNISHED FACTORY-GLAZED IN UNICEL'S FIRE-RATED STEEL TRIMS (20 MIN. UL / 60 MIN. BS)
MAXIMUM CUT-OUT DIMENSIONS OF ROUGH OPENING IN DOOR SLAB = 36'' X 79'' (914mm X 2007mm)

FOLDABLE ZINC
46mm CRANK HANDLE
1 13/16''

B
VISION CONTROL OVAL
MINI PANEL PLATE

C GEAR HOUSING
A

STANDARD FINISHES* LOUVERS DOOR TRIMS

DURACRON WHITE K-1285

DURACRON GRAY K-20794 6 31/32"


177mm

CLEAR ANODIZED (CLASS II) 1/4" (6mm) CLEAR


TEMPERED GLASS
* OTHER FINISHES AVAILABLE UPON REQUEST.
5/16'' (8mm) FIRELITE
PLUS 20 MIN.
FIRE GLAZING TAPE
90 MIN. 1/16'' X 7/16''
(1.6mm X 11.1mm)

CONTINUOUS INTUMESCENT CALCIUM SILICATE


MATERIAL BY UNICEL SETTING BLOCK

18 GAUGE STEEL FRAME

10/32 NF 3/8'' SCREW PUNCTUAL SPOT WELDS


73mm
2 7/8''

A CONTINUOUS INTUMESCENT
MATERIAL BY OTHERS
44.5mm WOOD MINERAL CORE
VISION CONTROL CONTINUOUS 1 3/4'' DOOR BY OTHERS
73mm 54.8mm
MINI PANEL INTUMESCENT FIRE GLAZING TAPE
2 7/8''
MATERIAL BY UNICEL 2 5/32'' BY OTHERS

22.2mm
CONTINUOUS
INTUMESCENT 73mm
7/8'' FOLDABLE ZINC
MATERIAL BY OTHERS 2 7/8''
CRANK HANDLE

OVAL PLATE
44.5mm

54.8mm
2 5/32''
1 3/4''

B
C
237.3mm
9 11/32"

6 31/32"
177mm

18 GAUGE STEEL
FRAME
CALCIUM SILICATE
5/16'' (8mm) FIRELITE GEAR HOUSING SETTING BLOCK
PLUS 20 MIN.

1/4" (6mm) CLEAR


TEMPERED GLASS
73mm
2 7/8''

FOLDABLE ZINC
CRANK HANDLE

R
Unicel Architectural Corp.
2155 Fernand-Lafontaine
Longueuil Qubec J4G 2J4 Canada
VC MINI 3.4.2
T: 800.668.1580 | 450.670.6844 F: 866.496.2628 | 450.670.7144 08-2017
E: unicel@unicelarchitectural.com www.unicelarchitectural.com
VISION CONTROL MINI
ARCHITECTURAL
SLIDING DOORS

FLAT KNOB OPERABLE ON ONE OR BOTH SIDE(S)


VISION CONTROL MINI WITH UNIVERSAL ALUMINUM TRIMS SENT LOOSE

44.5mm
1 3/4''
25.4mm
1''
1 1/2" (38.1mm)
C FLAT ALUMINUM
KNOB OPERATOR 4.8mm
(OPTIONAL) 3/16''

GEAR HOUSING
A A
INVERSE

FOR OPERATORS AVAILABLE)


(NON-STANDARD LOCATION
B 1 1/2" (38.1mm)
FLAT ALUMINUM
KNOB OPERATOR

6 31/32''
177mm
VISION CONTROL
1 1/2" (38.1mm) MINI PANEL
FLAT ALUMINUM
3/16" (5mm) CLEAR
KNOB OPERATOR
TEMPERED GLASS

33.3mm
1 5/16''
A 12.7mm

VISION CONTROL SNAP-ON TRIM


1/2''

MINI PANEL
SETTING BLOCK
BY OTHERS
SLIDING DOORS
SETTING BLOCK BY OTHERS UNICEL UNIVERSAL
BY OTHERS TRIMS

SLIDING DOORS
BY OTHERS
B
25.4mm

SCREW
1''

BY OTHERS
FLAT ALUMINUM
KNOB OPERATOR
44.4mm
1 3/4''

(OPTIONAL) UNICEL ALUMINUM


UNIVERSAL TRIMS

3/16" (5mm) CLEAR


12.7mm CLEARANCE
TEMPERED GLASS
1/2'' REQUIRED
FLAT ALUMINUM 4.8mm
KNOB OPERATOR 3/16''
(OPTIONAL)

SLIDING DOORS VISION CONTROL GEAR HOUSING


BY OTHERS MINI PANEL
C UNICEL ALUMINUM
UNIVERSAL TRIMS

1 1/2" (38.1mm)
FLAT ALUMINUM
STANDARD FINISHES* LOUVERS
UNIVERSAL KNOB OPERATOR
TRIMS

DURACRON WHITE K-1285

DURACRON GRAY K-20794

CLEAR ANODIZED (CLASS II)

* OTHER FINISHES AVAILABLE UPON REQUEST.

R
Unicel Architectural Corp.
2155 Fernand-Lafontaine
Longueuil Qubec J4G 2J4 Canada
VC MINI 3.5.1
T: 800.668.1580 | 450.670.6844 F: 866.496.2628 | 450.670.7144 08-2017
E: unicel@unicelarchitectural.com www.unicelarchitectural.com
VISION CONTROL MINI
ARCHITECTURAL
SLIDING DOORS

THUMBWHEEL OPERABLE BOTH SIDES


VISION CONTROL MINI WITH UNIVERSAL ALUMINUM TRIMS

44.5mm
1 3/4''
25.4mm
1''
C FULL THUMBWHEEL
OPERATOR ACCESSIBLE ON BOTH SIDES
3.2mm
ALSO AVAILABLE: FAN-SHAPED THUMBWHEEL 3.2mm
1/8'' 1/8''
OPERATOR ACCESSIBLE ON ONE SIDE

CUT-OUT
CUT-OUT
A A BY UNICEL
INVERSE

FOR OPERATORS AVAILABLE)


(NON-STANDARD LOCATION
B

188.1mm
7 13/32''
VISION CONTROL
MINI PANEL
THUMBWHEEL
3/16" (5mm) CLEAR
OPERATOR
TEMPERED GLASS

33.3mm
1 5/16''
A 12.7mm

VISION CONTROL SNAP-ON TRIM


1/2''

MINI PANEL
SETTING BLOCK
BY OTHERS
SLIDING DOORS
SETTING BLOCK BY OTHERS UNICEL UNIVERSAL
BY OTHERS TRIMS

SLIDING DOORS
BY OTHERS
B
25.4mm

SCREW
1''

BY OTHERS

THUMBWHEEL
44.4mm
1 3/4''

OPERATOR UNICEL ALUMINUM


UNIVERSAL TRIMS

3/16" (5mm) CLEAR


12.7mm CLEARANCE
TEMPERED GLASS
1/2'' REQUIRED
4.8mm
3/16''

THUMBWHEEL
SLIDING DOORS VISION CONTROL OPERATOR
BY OTHERS MINI PANEL
C UNICEL ALUMINUM
UNIVERSAL TRIMS

UNIVERSAL
STANDARD FINISHES* LOUVERS
TRIMS CUT-OUT
DURACRON WHITE K-1285 BY UNICEL

DURACRON GRAY K-20794


3.2mm

CLEAR ANODIZED (CLASS II)


1/8''

9.5mm 7.9mm
* OTHER FINISHES AVAILABLE UPON REQUEST. 3/8'' 5/16''

R
Unicel Architectural Corp.
2155 Fernand-Lafontaine
Longueuil Qubec J4G 2J4 Canada
VC MINI 3.5.2
T: 800.668.1580 | 450.670.6844 F: 866.496.2628 | 450.670.7144 08-2017
E: unicel@unicelarchitectural.com www.unicelarchitectural.com
VISION CONTROL MINI
ARCHITECTURAL
MOTORIZATION

SOMFY MOTOR

1- WORM GEAR SHAFT


2- GEARING WHEEL
3- GEAR HOUSING 1 15/32" x 2 5/32" (37.3mm x 54.8mm)
4- PLASTIC COVER & SCREW #5-40 x 1/2" (12.7mm)
5- FLEXIBLE CABLE
6- SOMFY MOTOR
7- VISION CONTROL MINI PANEL

2
7

1
4

MOTOR SPECIFICATIONS:
- MODEL: SOMFY
- APPROX. DIM.: 29/32" x 1 7/32"
(23.1mm x 31.2mm)
- AMP: 1.2
- VOLTS: 12 DC
- RPM: 68
- RTS: 433.42 MHZ

MOTOR TYPE TO BE DETERMINED BY


UNICEL'S ENGINEERING DEPARTMENT
NOTE: REFER TO APPROVED SHOP DRAWINGS FOR MORE INFORMATION

R
Unicel Architectural Corp.
2155 Fernand-Lafontaine
Longueuil Qubec J4G 2J4 Canada
VC MINI 4.1.1
T: 800.668.1580 | 450.670.6844 F: 866.496.2628 | 450.670.7144 08-2017
E: unicel@unicelarchitectural.com www.unicelarchitectural.com
VISION CONTROL MINI
ARCHITECTURAL
GROUPED MOTORIZATION

SOMFY MOTOR
UNLIMITED NUMBER OF VISION CONTROL MINI PANELS, ONE MOTOR PER UNIT

1- SOMFY MOTOR
2- GEAR HOUSING 1 15/32" x 2 5/32" 1
(37.4mm x 54.8mm)
3- FLEXIBLE CABLE 3
4
4- VISION CONTROL MINI PANEL

28.6mm CLEARANCE
1 1/8" (TYPICAL)

WIRING DIAGRAM FOR 12 VOLT DC MOTOR

MOTOR SPECIFICATIONS:
- MODEL: SOMFY
- APPROX. DIM.: 29/32" x 1 7/32"
(23.1mm x 31.2mm)
- AMP: 1.2
- VOLTS: 12 DC
- RPM: 68
- RTS: 433.42 MHZ
VISION CONTROL
MINI PANEL

MOTOR

12 VOLT
POWER SUPPLY

120 - 220 V/AC

R
Unicel Architectural Corp.
2155 Fernand-Lafontaine
Longueuil Qubec J4G 2J4 Canada
VC MINI 4.1.2
T: 800.668.1580 | 450.670.6844 F: 866.496.2628 | 450.670.7144 08-2017
E: unicel@unicelarchitectural.com www.unicelarchitectural.com
VISION CONTROL MINI
ARCHITECTURAL
MOTORIZATION

SOMFY MOTOR

101.6mm
4''
SOMFY MOTOR

B
VISION CONTROL SOMFY MOTOR
MINI PANEL
28.6mm 44.5mm
1 1/8'' 1 3/4''

44.4mm
1 3/4''

VARIES
127mm OR 152.4mm

25.4mm 25.4mm
1'' 1''
FLEXIBLE CABLE
5" OR 6"
25.4mm

31.2mm
1 7/32''
1''

37.3mm
1 15/32''
23.1mm
25.4mm

29/32''
54.8mm
1''

2 5/32''

VISION CONTROL
MINI PANEL

188.1mm
7 13/32"
GEAR HOUSING 37.3mm
1 15/32''
44.4mm
25.4mm

1 3/4''

GEAR HOUSING
DETAIL
1''

A INTERIOR
ALUMINUM FRAME &
GLASS STOPS
BY UNICEL
ALUMINUM FRAME &
GLASS STOPS
BY UNICEL
MOTOR SPECIFICATIONS:
44.5mm

- MODEL: SOMFY
1 3/4''

127mm OR 152.4mm
- APPROX. DIM.: 29/32" x 1 7/32" SETTING BLOCK
BY OTHERS 5" OR 6"
(23.1mm x 31.2mm)
- AMP: 1.2
6.4mm

- VOLTS: 12 DC
1/4''

- RPM: 68
- RTS: 433.42 MHZ DETAIL
B INTERIOR

R
Unicel Architectural Corp.
2155 Fernand-Lafontaine
Longueuil Qubec J4G 2J4 Canada
VC MINI 4.1.3
T: 800.668.1580 | 450.670.6844 F: 866.496.2628 | 450.670.7144 08-2017
E: unicel@unicelarchitectural.com www.unicelarchitectural.com
VISION CONTROL MINI
ARCHITECTURAL
MOTORIZATION

BALDOR MOTOR

1- WORM GEAR SHAFT


2- GEARING WHEEL
3- GEAR HOUSING 1 15/32" x 2 5/32" (37.4mm x 54.8mm)
4- PLASTIC COVER & SCREW #5-40 x 1/2" (12.7mm)
5- FLEXIBLE CABLE
3
6- CORNER DRIVE
7- BALDOR MOTOR
8- RIGID SHAFT 5/8" (15.9mm)
9- VISION CONTROL MINI PANEL
10- SET SCREW #10-24 x 3/16" (4.8mm) 2
9

1
4

10
8

10

MOTOR SPECIFICATIONS:
- MODEL: BALDOR
- APPROX. DIM.: 3 3/4" x 8 1/8" 6
(95.3mm x 206.4mm)
- AMP: 1
- VOLTS: 120 AC
- RPM: 163
- HZ: 60 7
- PHASE: 1
- TORQUE 28.5 IN-LB
MOTOR TYPE TO BE DETERMINED BY
UNICEL'S ENGINEERING DEPARTMENT
NOTE: REFER TO APPROVED SHOP DRAWINGS FOR MORE INFORMATION

R
Unicel Architectural Corp.
2155 Fernand-Lafontaine
Longueuil Qubec J4G 2J4 Canada
VC MINI 4.2.1
T: 800.668.1580 | 450.670.6844 F: 866.496.2628 | 450.670.7144 08-2017
E: unicel@unicelarchitectural.com www.unicelarchitectural.com
VISION CONTROL MINI
ARCHITECTURAL
GROUPED MOTORIZATION
(WITH LIMIT SWITCH)

BALDOR MOTOR
MAXIMUM OF 12 VISION CONTROL MINI PANELS PER MOTOR (MAY VARY DEPENDING ON SIZES)

7 8
1 2
5

1- BALDOR MOTOR
2- CORNER DRIVE 3
3- GEAR HOUSING 1 15/32" x 2 5/32"
(37.4mm x 54.8mm)
4- FLEXIBLE CABLE
5- RIGID SHAFT 5/8" (15.9mm) 4
6- VISION CONTROL MINI PANEL
7- JUNCTION BOX
8- LIMIT SWITCH
3

12.7mm CLEARANCE
1/2" (TYPICAL)

WIRING DIAGRAM FOR 120 VOLT AC MOTOR WITH LIMIT SWITCH

MOTOR SPECIFICATIONS:
- MODEL: BALDOR
- APPROX. DIM.: 3 3/4" x 8 1/8"
(95.3mm x 206.4mm)
- AMP: 1
VISION CONTROL
- VOLTS: 120 AC MINI PANEL
- RPM: 163
- HZ: 60
- PHASE: 1
- TORQUE 28.5 IN-LB MOTOR

ELECTRICAL DIAGRAM
LIMIT SWITCH
#1

JUNCTION BOX
NO
AC LINE MOTOR
120 VOLTS #5 C NC #5
WIRE
CAPACITOR

CAM ELECTRIC BOX FOR SWITCH


(MUST BE INSTALLED
IN A LOCATION PERMITTING
SPDT VISUAL CONTROL)
NC #0
SWITCH
NOTES: #0 C
1- SWITCH SPDT SHOWN FOR ILLUSTRATION ONLY NO 120 - 220 V-AC
2- LIMIT SWITCH SHOWN IN CLOSED POSITION LIMIT
3- POWER TO THE #5 WIRE OPERATES UNIT INTO CLOSED POSITION SWITCH
4- POWER TO THE #0 WIRE OPERATES UNIT INTO CLOSED POSITION

R
Unicel Architectural Corp.
2155 Fernand-Lafontaine
Longueuil Qubec J4G 2J4 Canada
VC MINI 4.2.2
T: 800.668.1580 | 450.670.6844 F: 866.496.2628 | 450.670.7144 08-2017
E: unicel@unicelarchitectural.com www.unicelarchitectural.com
VISION CONTROL MINI
ARCHITECTURAL
GROUPED MOTORIZATION
(WITHOUT LIMIT SWITCH)

BALDOR MOTOR
MAXIMUM OF 12 VISION CONTROL MINI PANELS PER MOTOR (MAY VARY DEPENDING ON SIZES)

7 1 2
5

1- BALDOR MOTOR
2- CORNER DRIVE 3
3- GEAR HOUSING 1 15/32" x 2 5/32"
(37.4mm x 54.8mm)
4- FLEXIBLE CABLE
5- RIGID SHAFT 5/8" (15.9mm) 4
6- VISION CONTROL MINI PANEL
7- JUNCTION BOX

12.7mm CLEARANCE
1/2" (TYPICAL)

WIRING DIAGRAM FOR 120 VOLT AC MOTOR WITHOUT LIMIT SWITCH

MOTOR SPECIFICATIONS:
- MODEL: BALDOR
- APPROX. DIM.: 3 3/4" x 8 1/8"
(95.3mm x 206.4mm)
- AMP: 1
VISION CONTROL
- VOLTS: 120 AC MINI PANEL
- RPM: 163
- HZ: 60
- PHASE: 1
- TORQUE 28.5 IN-LB MOTOR

ELECTRICAL DIAGRAM

JUNCTION BOX
GREEN - YELLOW
MOTOR

WIRE

#1 NEUTRAL
CAPACITOR ELECTRIC BOX FOR SWITCH
(MUST BE INSTALLED
IN A LOCATION PERMITTING
#5 VISUAL CONTROL)

120 VOLTS AC
120 - 220 V-AC
#0

SWITCH

R
Unicel Architectural Corp.
2155 Fernand-Lafontaine
Longueuil Qubec J4G 2J4 Canada
VC MINI 4.2.3
T: 800.668.1580 | 450.670.6844 F: 866.496.2628 | 450.670.7144 08-2017
E: unicel@unicelarchitectural.com www.unicelarchitectural.com
VISION CONTROL MINI
ARCHITECTURAL
MOTORIZATION

BALDOR MOTOR
(SUGGESTED DETAIL)

BALDOR MOTOR
CORNER DRIVE
ALUMINUM
TRACK

9.5mm
3/8''
63.5mm
2 1/2''
A
B

MINIMUM 8" (203.2 mm)


LAY-IN CEILING LIMIT SWITCH
VARIES

BALDOR MOTOR

FLEXIBLE CABLE
CORNER DRIVE
11/32''
9mm

FLEXIBLE CABLE
63.5mm
2 1/2''

MOTOR SPECIFICATIONS:
63.5mm
2 1/2''
- MODEL: BALDOR
12.7mm

- APPROX. DIM.: 3 3/4" x 8 1/8"


1/2''

(95.3mm x 206.4mm)
188.1 mm
7 13/32"

VISION CONTROL
- AMP: 1
MINI PANEL - VOLTS: 120 AC
- RPM: 163

188.1mm
7 13/32"
- HZ: 60
37.3mm - PHASE: 1
1 15/32'' - TORQUE 28.5 IN-LB
37.3mm
1 15/32''
54.8mm
2 5/32''

54.8mm
2 5/32''

GEAR HOUSING GEAR HOUSING

15.9mm 31.8mm 63.5mm 21.1mm 33.7mm 88.9mm


5/8'' 1 1/4'' 2 1/2'' 27/32'' 1 5/16'' 3 1/2''
12.9mm

THERMALLY BROKEN
1/2''

ALUMINUM FRAME
VISION CONTROL
MINI PANEL
63.5mm
2 1/2''
8.9mm
11/32''
63.5mm
2 1/2''

11/32''
9mm

DETAIL DETAIL
A B
INTERIOR WALL EXTERIOR WALL

R
Unicel Architectural Corp.
2155 Fernand-Lafontaine
Longueuil Qubec J4G 2J4 Canada
VC MINI 4.2.4
T: 800.668.1580 | 450.670.6844 F: 866.496.2628 | 450.670.7144 08-2017
E: unicel@unicelarchitectural.com www.unicelarchitectural.com
VISION CONTROL MINI
ARCHITECTURAL
MOTORIZATION

PITTMAN MOTOR

1- WORM GEAR SHAFT


2- GEARING WHEEL
3- GEAR HOUSING 1 15/32" x 2 5/32" (37.4mm x 54.8mm)
4- PLASTIC COVER & SCREW #5-40 x 1/2" (12.7mm)
5- FLEXIBLE CABLE
3
6- CORNER DRIVE
7- PITTMAN MOTOR
8- RIGID SHAFT 5/8" (15.9mm)
9- VISION CONTROL MINI PANEL
10- SET SCREW #10-24 x 3/16" (4.8mm) 2
9

1
4

10
8

10

MOTOR SPECIFICATIONS: 6
- MODEL: PITTMAN
- APPROX. DIM.: 2" x 3 5/8"
(50.8mm x 92.1mm)
- AMP: 0.6
7
- VOLTS: 24 DC
- RPM: 160
MOTOR TYPE TO BE DETERMINED BY
UNICEL'S ENGINEERING DEPARTMENT
NOTE: REFER TO APPROVED SHOP DRAWINGS FOR MORE INFORMATION

R
Unicel Architectural Corp.
2155 Fernand-Lafontaine
Longueuil Qubec J4G 2J4 Canada
VC MINI 4.3.1
T: 800.668.1580 | 450.670.6844 F: 866.496.2628 | 450.670.7144 08-2017
E: unicel@unicelarchitectural.com www.unicelarchitectural.com
VISION CONTROL MINI
ARCHITECTURAL
MOTORIZATION
(WITH LIMIT SWITCH)

PITTMAN MOTOR
MAXIMUM OF 4 VISION CONTROL MINI PANELS PER MOTOR (MAY VARY DEPENDING ON SIZES)

SEE VC MINI 4.3.4


A

7 8
1 2
5

1- PITTMAN MOTOR
4
2- CORNER DRIVE
6
3- GEAR HOUSING 1 15/32" x 2 5/32"
(37.4mm x 54.8mm)
4- FLEXIBLE CABLE 3
5- RIGID SHAFT 5/8" (15.9mm)
6- VISION CONTROL MINI PANEL
7- JUNCTION BOX
8- LIMIT SWITCH

WIRING DIAGRAM FOR 24 VDC MOTOR WITH LIMIT SWITCH

MOTOR SPECIFICATIONS:
- MODEL: PITTMAN
- APPROX. DIM.: 2" x 3 5/8"
(50.8mm x 92.1mm)
- AMP: 0.6 VISION CONTROL
MINI PANEL
- VOLTS: 24 DC
- RPM: 160

ELECTRICAL DIAGRAM MOTOR

LIMIT LIMIT SWITCH


#5 SWITCH

MOTOR JUNCTION BOX


RED
BLACK BLACK
24 VDC WIRE
RED LIMIT
#0 SWITCH
STANDARD ELECTRIC BOX
FOR DPDT SWITCH
DPDT MAINTAIN OR WIRE
MOMENTARY SWITCH
#1 24 VDC POWER SUPPLY

120 - 220 V-AC

R
Unicel Architectural Corp.
2155 Fernand-Lafontaine
Longueuil Qubec J4G 2J4 Canada
VC MINI 4.3.2
T: 800.668.1580 | 450.670.6844 F: 866.496.2628 | 450.670.7144 08-2017
E: unicel@unicelarchitectural.com www.unicelarchitectural.com
VISION CONTROL MINI
ARCHITECTURAL
MOTORIZATION
(WITHOUT LIMIT SWITCH)

PITTMAN MOTOR
MAXIMUM OF 4 VISION CONTROL MINI PANELS PER MOTOR (MAY VARY DEPENDING ON SIZES)

SEE VC MINI 4.3.4


B

1 2
5
7

1- PITTMAN MOTOR
2- CORNER DRIVE 4
6
3- GEAR HOUSING 1 15/32" x 2 5/32"
(37.4mm x 54.8mm)
4- FLEXIBLE CABLE 3
5- RIGID SHAFT 5/8" (15.9mm)
6- VISION CONTROL MINI PANEL
7- JUNCTION BOX

WIRING DIAGRAM FOR 24 VDC MOTOR WITHOUT LIMIT SWITCH

MOTOR SPECIFICATIONS:
- MODEL: PITTMAN
- APPROX. DIM.: 2" x 3 5/8"
(50.8mm x 92.1mm)
- AMP: 0.6 VISION CONTROL
MINI PANEL
- VOLTS: 24 DC
- RPM: 160

ELECTRICAL DIAGRAM MOTOR

MOTOR
RED JUNCTION BOX
BLACK

WIRE

STANDARD ELECTRIC BOX


FOR DPDT SWITCH

BLACK WIRE
24 VDC
RED
24 VDC POWER SUPPLY
LOCATE THIS SUPPLY NEAR
YOUR ELECTRICAL PANEL
DPDT
MOMENTARY 120 - 220 V-AC
SWITCH

R
Unicel Architectural Corp.
2155 Fernand-Lafontaine
Longueuil Qubec J4G 2J4 Canada
VC MINI 4.3.3
T: 800.668.1580 | 450.670.6844 F: 866.496.2628 | 450.670.7144 08-2017
E: unicel@unicelarchitectural.com www.unicelarchitectural.com
VISION CONTROL MINI
ARCHITECTURAL
MOTORIZATION

PITTMAN MOTOR
(SUGGESTED DETAIL)

ALUMINUM TRACK ALUMINUM TRACK


PITTMAN MOTOR PITTMAN MOTOR

CORNER DRIVE LIMIT SWITCH CORNER DRIVE


BOX

ALUMINUM ALUMINUM
SUPPORT SUPPORT

LAY-IN CEILING VARIES LAY-IN CEILING

VARIES
BY OTHERS BY OTHERS

FLEXIBLE CABLE FLEXIBLE CABLE


50.8mm

50.8mm

50.8mm

50.8mm
2''

2''

2''

2''
28.6mm

28.6mm
1 1/8''

1 1/8''
188.1mm

188.1mm
7 13/32''

7 13/32''
VISION CONTROL VISION CONTROL
MINI PANEL MINI PANEL
19.1mm 19.1mm 19.1mm 19.1mm
3/4'' 3/4'' 3/4'' 3/4''
37.3mm 37.3mm
GEAR HOUSING 1 15/32'' GEAR HOUSING 1 15/32''
54.8mm

54.8mm
2 5/32''

2 5/32''

MOTOR SPECIFICATIONS:
- MODEL: PITTMAN
1.6mm 31.8mm 1.6mm - APPROX. DIM.: 2" x 3 5/8" 1.6mm 31.8mm 1.6mm
1/16'' 1 1/4'' 1/16'' (50.8mm x 92.1mm) 1/16'' 1 1/4'' 1/16''
- AMP: 0.6
28.6mm

28.6mm
1 1/8''
1 1/8''

- VOLTS: 24 DC
- RPM: 160
12.7mm

12.7mm
50.8mm

50.8mm
1/2''

1/2''
2''

2''

ALUMINUM SNAP-ON ALUMINUM SNAP-ON


GLASS STOPS GLASS STOPS
DETAIL DETAIL
BY UNICEL A INTERIOR WALL
BY UNICEL B INTERIOR WALL

R
Unicel Architectural Corp.
2155 Fernand-Lafontaine
Longueuil Qubec J4G 2J4 Canada
VC MINI 4.3.4
T: 800.668.1580 | 450.670.6844 F: 866.496.2628 | 450.670.7144 08-2017
E: unicel@unicelarchitectural.com www.unicelarchitectural.com
VISION CONTROL MINI
ARCHITECTURAL
STORAGE & HANDLING

Storage Instructions

A. In Crates

Crates must be kept upright, covered, ventilated and in a dry and safe location.

B. Loose Lots

Sealed units must be upright, on blocks and in a safe and dry location. Sealed units should not be stored in
a stack, or in direct sunlight as heat build-up may cause breakage. Sealed units should have a base to
provide support to all component lites of the unit so that individual lites will not slide out of alignment or out
of square causing seal failure or breakage.

INCORRECT CORRECT
METHOD METHOD
WALL

WALL
FLOOR FLOOR
Handling Instructions

A. Extreme care must be taken when a unit is being moved. Edges and corners should be protected in order to
prevent glass from fracturing. The use of a corner protector is suggested.

SEALED UNIT WOOD BLOCKING

PLYWOOD 304.8mm
CORNER PROTECTOR 1/2" (12.7mm) 1'-0''

VA
RIE
S m
.8m
304 1'-0''

B. When moving Vision Control Mini sealed glass panels, always do so as indicated below, flat or the gear
housing downwards.

GEAR HOUSING

GEAR HOUSING

R
Unicel Architectural Corp.
2155 Fernand-Lafontaine
Longueuil Qubec J4G 2J4 Canada
VC MINI 6.1
T: 800.668.1580 | 450.670.6844 F: 866.496.2628 | 450.670.7144 08-2017
E: unicel@unicelarchitectural.com www.unicelarchitectural.com
VISION CONTROL MINI
ARCHITECTURAL
INSTALLATION INSTRUCTIONS

GLAZING INSTRUCTIONS

Frame/Sash

1. All framing members must be specifically designed to accept the glass specified and must have adequate structural
strength to support the weight of the glass without deformation.

2. Frame and/or sash must be level, plumb, square and in plane and also be free of any glazing obstruction.

3. Joints must be adequately buttered with sealant to prevent water and air infiltration and all sill members must have
weep holes to the outside.

Clearance and edge bite

1. Adequate edge and face clearances must be provided to allow the glass to float freely in the opening, without undue
restriction by the framing members. The recommended clearance on both vertical edges of the units is a minimum
of 1/2" (12.7mm), (9/16" (14.3mm) for double panels).

2. Adequate bite is mandatory to maintain a watertight, weather-proof seal as well as retain the glass in the opening
under conditions of wind loading and deformation of the framing members.

Setting blocks and spacers

1. Silicone setting blocks should be used on the bottom edge of each lite. Place setting blocks at the end points.

Sealing materials

1. For channel glazing, use only a non-hardening, non-corrosive, gun-applied sealant specifically recommended by the
sealant manufacturer for the type of glass specified

2. In no case shall glazing be performed with any oleo-resinous or oil-base compounds, nor shall any glazing sealant
be diluted or thinned with any solvent.

3. Never fill the space between the bottom edge of the glass and the sill. This will interfere with the weepage system.

4. All sealants must be applied to provide an absolute watertight seal; on insulating glass units, sealant must contact
the glass a minimum of 1/8 (3.2mm) above the metal edge protection.

5. Sash with neoprene or structural neoprene gaskets must have a supplementary wet seal applied between the
gasket and the glass, at the bottom edge (sill) of the glass and 6 (152.4mm) up on each jamb. Sill section of all
structural neoprene gaskets must have weep holes to the exterior.

6. Special care must be taken when glazing laminated glass, polycarbonates and glass-clad polycarbonates, as they
may react unfavorably with certain sealant components. Sealants made of 100% solid components, containing no
solvents, must be used. Verify with your sealant manufacturer.

7. All surfaces to be sealed must be completely clean and dry. Verify with sealant manufacturer's recommendations for
proper cleaning procedures.

R
Unicel Architectural Corp.
2155 Fernand-Lafontaine
Longueuil Qubec J4G 2J4 Canada
VC MINI 6.2
T: 800.668.1580 | 450.670.6844 F: 866.496.2628 | 450.670.7144 08-2017
E: unicel@unicelarchitectural.com www.unicelarchitectural.com
VISION CONTROL MINI
ARCHITECTURAL
INSTALLATION INSTRUCTIONS

CRANK HANDLE OR KNOB OPERATORS 15

15 15 7B 14
1- WORM GEAR SHAFT 5C
2- GEARING WHEEL OPTION: DOUBLE ABS
ANTI-LIGATURE KNOB
3- GEAR HOUSING 1 1/4" x 2 5/32" (31.8mm x 54.8mm)
4- PLASTIC COVER & SCREW #5-40 x 1/2" (12.7mm) 5B
5A- ZINC CRANK HANDLE 7A OPTION: DOUBLE
5B- ALUMINUM KNOB ALUMINUM KNOB
5A
5C- ABS ANTI-LIGATURE KNOB
OPTION: DOUBLE ZINC
6- SCREW #6 x 1/2" (12.7mm) 3 8 CRANK HANDLE
7A- OVAL PLATE
9
7B- ROUND PLATE
8- EXTENSION SHAFT
13
9- VISION CONTROL MINI PANEL 2
10- FRAME BY OTHERS
11- HEXAGONAL SOCKET
12- SETTING BLOCK 15 8
13- ALUMINUM BLOCK
14- BRASS ADAPTOR 5A 7A
HOLE (SEE STEP D)
15- SET SCREW 1 4
6
15

5B
15 7B
12

5C
14 11

10 OPTION: REMOVABLE ZINC CRANK HANDLE

A. Install stainless steel worm gear shaft 1 into the cavity provided for it in the plastic cover 4 . To insert the worm gear shaft in position, center the
worm gear shaft between two rings and press firmly. Insert the white gearing wheel 2 on the brass shaft.

B. Make sure that the gear housing 3 is free of dirt. Screw the plastic cover 4 in place. Do not use excessive torque on screws in securing the plastic
cover.

C. (Skip this step if the operator is an anti-ligature knob 5C ). Test the functionality of the units by temporarily installing the operator 5A or 5B and
tightening the set screw 15 . The mechanism is self-reversing and should be tested as follows: Turn the operator in one direction (e.g. clockwise).
When the louvers reach the closed position, continue turning 4-8 times in the same direction (e.g. clockwise) without fear of breaking the mechanism
until the louvers eventually re-open. Complete two full louver cycles by turning the operator in the same direction (e.g. clockwise). Repeat these steps
in the opposite direction (e.g. counter-clockwise) for two more full louver cycles.

D. Drill the following hole (behind the aluminum block 13 ) in glass stop at the appropriate position (for worm gear shaft 1 according to Unicel's approved
shop drawings): for the zinc crank handle 5A and the aluminum knob 5B , drill a 5/8" (15.9mm) diameter hole; for the ABS anti-ligature knob 5C , drill
a 3/8" (9.5mm) diameter hole.

E. Install setting blocks 12 under the metal plates glued to the unit. Make sure they are sufficiently rigid to secure glass panel into its permanent position.

F. Install the Vision Control Mini panel 9 in the opening which must be level, plumb, square and in plane. Make sure the shaft 1 is centered in the hole
drilled in step D.

G. Where necessary, install aluminum supporting block 13 by securing with screws.

H. According to operator:
1. Zinc crank handle: Screw the oval plate 7A , the crank handle 5A and extension shaft 8 into the the frame with screws 6 .
Tighten the set screw 15 of the crank handle 5A if loose.
2. Aluminum knob: Screw the oval plate 7A , the knob 5B and extension shaft 8 into the the frame with screws 6 .
Tighten the set screw 15 of the knob 5B if loose.
3. ABS anti-ligature knob: Assemble the extension shaft 8 with the round plate 7B and the brass adaptor 14 and tighten the set screw. Screw the
assembly and the base of the knob 5C into the frame with screws 6 . Push the knob 5C firmly into its base.

R
Unicel Architectural Corp.
2155 Fernand-Lafontaine
LongueuilQubecJ4G 2J4Canada
VC MINI 6.3
T: 800.668.1580 |450.670.6844F:866.496.2628| 450.670.7144 08-2017
E: unicel@unicelarchitectural.comwww.unicelarchitectural.com
VISION CONTROL MINI
ARCHITECTURAL
INSTALLATION INSTRUCTIONS

FULL THUMBWHEEL OPERATOR

IMPORTANT NOTE:

This operation must be performed before installing


RETAINING RING
the glass units in their respective openings.

Test the functionality of the units by turning the


thumbwheel in one direction (e.g. clockwise). When the
louvers reach the closed position, continue turning in
the same direction (e.g. clockwise) without fear of
breaking the mechanism until the louvers eventually
re-open. Complete two full louver cycles by turning the
operator, always in the same direction (e.g. clockwise).
Repeat these steps in the opposite direction (e.g.
counter-clockwise) for two more full louver cycles.

STEP 1 STEP 2

SETTING BLOCK SETTING BLOCK


METAL PLATE METAL PLATE

ADDITIONAL INSTRUCTIONS
Install setting blocks under the metal plates glued to each unit. Make sure they are sufficiently rigid to secure the glass panels into their
permanent position. The units must be level, plumb, square and in plane. Install the glass stops, which should have been notched at
predetermined locations according to approved shop drawings, to accomodate thumbwheel operator.

R
Unicel Architectural Corp.
2155 Fernand-Lafontaine
Longueuil Qubec J4G 2J4 Canada
VC MINI 6.4
T: 800.668.1580 | 450.670.6844 F: 866.496.2628 | 450.670.7144 08-2017
E: unicel@unicelarchitectural.com www.unicelarchitectural.com
VISION CONTROL MINI
ARCHITECTURAL
INSTALLATION INSTRUCTIONS

FAN-SHAPED THUMBWHEEL OPERATORS

IMPORTANT NOTE:

This operation must be performed before installing the glass units in their respective openings.
Follow the instructions for either left side or right side, as required.

LEFT SIDE L AND RIGHT SIDE R


STICKERS SHOULD BE FACING OUT
STEP 1

LEFT RIGHT

LOUVERS IN LOUVERS IN
OPEN POSITION OPE OPEN POSITION
IDE LEFT AND RIGHT SIDES WHEN RAB
LE S LE S
RAB VIEWED FROM THE OPERABLE
IDE
OPE SIDE OF THE ROOM

SETTING BLOCK SETTING BLOCK


STEP 2 METAL PLATE METAL PLATE

LEFT RIGHT

IDE
OPE
LE S
RAB
AB LE S
O PER IDE

ADDITIONAL INSTRUCTIONS
Install setting blocks under the metal plates glued to each unit. Make sure they are sufficiently rigid to secure the glass panels into their
permanent position. The units must be level, plumb, square and in plane. Install the glass stops, which should have been notched at
predetermined locations according to approved shop drawings, to accomodate thumbwheel operator.

R
Unicel Architectural Corp.
2155 Fernand-Lafontaine
Longueuil Qubec J4G 2J4 Canada
VC MINI 6.5.1
T: 800.668.1580 | 450.670.6844 F: 866.496.2628 | 450.670.7144 08-2017
E: unicel@unicelarchitectural.com www.unicelarchitectural.com
VISION CONTROL MINI
ARCHITECTURAL
INSTALLATION INSTRUCTIONS

FAN-SHAPED THUMBWHEEL OPERATORS

IMPORTANT NOTE:

This operation must be performed before installing


the glass units in their respective openings.

Applicable for both left and right sides


If this orientation is not observed, please remove the thumbwheel, flip it and re-install it.

STEP 3

LEFT SIDE FAN-SHAPED THUMBWHEEL RIGHT SIDE FAN-SHAPED THUMBWHEEL

OPEN POSITION CLOSED POSITION OPEN POSITION CLOSED POSITION

TURN IN THIS TURN IN THIS TURN IN THIS TURN IN THIS


DIRECTION DIRECTION DIRECTION DIRECTION
TO OPEN THE TO CLOSE THE TO OPEN THE TO CLOSE THE
BLADES BLADES BLADES BLADES

L R

L R

FULL FULL FULL FULL


STOP STOP STOP STOP

NOTE: NOTE:
ROTATION LIMITED TO ROTATION LIMITED TO
APPROX. 115 INSTEAD OF 180 APPROX. 115 INSTEAD OF 180

115 115

LOUVERS COME DOWN FROM LOUVERS COME DOWN FROM


OPERABLE SIDE OPERABLE SIDE

R
Unicel Architectural Corp.
2155 Fernand-Lafontaine
Longueuil Qubec J4G 2J4 Canada
VC MINI 6.5.2
T: 800.668.1580 | 450.670.6844 F: 866.496.2628 | 450.670.7144 08-2017
E: unicel@unicelarchitectural.com www.unicelarchitectural.com
VISION CONTROL MINI
ARCHITECTURAL
INSTALLATION INSTRUCTIONS

FOR DOORS: VISION CONTROL MINI FURNISHED FACTORY-GLAZED IN UNICEL'S ALUMINUM TRIMS
Test the functionality of the units by turning the operator several times in each direction.

STEP A STEP B STEP C

SNAP ON TOP
REMOVE SNAP-ON TRIM
TRIM AT PERIMETER SILICONE

THIS SIDE
SHOULD BE
HELD IN PLACE
INTERIOR INTERIOR BY A WORKER INTERIOR
TO PREVENT
THE UNIT FROM
FALLING OUT

SETTING BLOCKS
(IF REQUIRED)
BY OTHERS

DOOR BY OTHERS
SNAP ON BOTTOM
44.5mm 44.5mm TRIM
VISION CONTROL MINI IS FURNISHED FOR SECURITY PURPOSES 1 3/4'' 1 3/4''
FACTORY-GLAZED IN UNICEL'S ADD A SILICONE BEAD INTO THE
ALUMINUM TRIMS FOR 1 3/4" (44.5mm) TRIM GROOVE BEFORE DOOR
THICK DOORS INSTALLING THE TRIMS BY OTHERS

STEP D STEP E STEP F


COEX GLAZING
COEX
(SEE STEP F)
GLAZING

COEX
GLAZING

INTERIOR

SNAP ON SNAP ON
VERTICAL VERTICAL
TRIM
A TRIM

SNAP-ON
TRIM

TRIM COEX GLAZING COEX GLAZING


GROOVE (SEE STEP F) INSTALLATION
DOOR BY OTHERS

DETAIL 44.5mm VIEWED FROM INTERIOR SIDE


A 1 3/4''

R
Unicel Architectural Corp.
2155 Fernand-Lafontaine
Longueuil Qubec J4G 2J4 Canada
VC MINI 6.6
T: 800.668.1580 | 450.670.6844 F: 866.496.2628 | 450.670.7144 08-2017
E: unicel@unicelarchitectural.com www.unicelarchitectural.com
VISION CONTROL MINI
ARCHITECTURAL
INSTALLATION INSTRUCTIONS
X-RAY SHIELDING DOOR

ZINC CRANK HANDLE OPERABLE ON ONE SIDE


Test the functionality of the units by temporarily installing the operator and tightening the set screw. The mechanism is self-reversing and
should be tested as follows: Turn the operator in one direction (e.g. clockwise). When the louvers reach the closed position, continue turning
4-8 times in the same direction (e.g. clockwise) without fear of breaking the mechanism until the louvers eventually re-open. Complete two full
louver cycles by turning the operator in the same direction (e.g. clockwise). Repeat these steps in the opposite direction (e.g.
counter-clockwise) for two more full louver cycles.

= = SNAP-ON
STEP A STEP B COVER PRESSURE
PR. PLATE

CONTINUOUS PLATE
6.4mm
PVC BLOCK 1/4''
3/32"X5/8"
BY OTHERS =

PRESSURE PLATE
6.4mm
1/4''
OPENING

OPENING
28.6mm
27.3mm

1 1/16''

1 1/8''

90
=

28.6mm
1 1/8''

TYPICAL DETAIL
SCREWS PRESSURE OPENING OPENING
PLATES
27.3mm
#10 X 1 1/2" (38.1mm)
1 1/16''
@ 6" (152.4mm)
2 SETTING BLOCKS
BY OTHERS
LEAD-LINING BY OTHERS
BY OTHERS

VARIES
INTERIOR INTERIOR

PRESSURE PLATE 44.5mm LEAD-LINED DOOR 44.5mm LEAD-LINED DOOR


1 3/4''
BY OTHERS 1 3/4''
BY OTHERS

STEP C STEP D
VISION CONTROL
MINI PANEL

VISION CONTROL
MINI PANEL

STAINLESS STEEL
WORM GEAR SHAFT

INTERIOR INTERIOR

R
Unicel Architectural Corp.
2155 Fernand-Lafontaine
Longueuil Qubec J4G 2J4 Canada
VC MINI 6.7.1
T: 800.668.1580 | 450.670.6844 F: 866.496.2628 | 450.670.7144 08-2017
E: unicel@unicelarchitectural.com www.unicelarchitectural.com
VISION CONTROL MINI
ARCHITECTURAL
INSTALLATION INSTRUCTIONS
X-RAY SHIELDING DOOR

ZINC CRANK HANDLE OPERABLE ON ONE SIDE

STEP E STEP F
CENTER S. S.
CONTINUOUS WORM GEAR SHAFT
PVC BLOCK
3/32"X5/8" BY OTHERS

7/16" (11.1mm) HOLE


BY UNICEL

DETAIL
A
STAINLESS STEEL
WORM GEAR SHAFT

7/16" (11.1mm) HOLE


BY UNICEL STAINLESS STEEL
WORM GEAR SHAFT
PRESSURE
PLATES
11.1mm

11.1mm
7/16''

7/16''
HOLE HOLE
BY UNICEL BY UNICEL

INTERIOR INTERIOR
A
SCREW
#10 X 1 1/2" (38.1mm)
@ 6" (152.4mm)
BY OTHERS
PRESSURE
PLATES

STEP G STEP H
28.6mm
1 1/8''

SNAP-ON
COVER SNAP-ON SNAP-ON
COVER COVER

CRANK
HANDLE
TIGHTEN
SET SCREW
11.1mm
7/16''

7/16" (11.1mm) HOLE


BY UNICEL

INTERIOR
28.6mm
1 1/8''

HOLE
BY UNICEL

R
Unicel Architectural Corp.
2155 Fernand-Lafontaine
Longueuil Qubec J4G 2J4 Canada
VC MINI 6.7.2
T: 800.668.1580 | 450.670.6844 F: 866.496.2628 | 450.670.7144 08-2017
E: unicel@unicelarchitectural.com www.unicelarchitectural.com
VISION CONTROL MINI
ARCHITECTURAL
INSTALLATION INSTRUCTIONS
X-RAY SHIELDING DOOR

FAN-SHAPED THUMBWHEEL OPERABLE ON ONE SIDE


Install the operator according to pages 6.5.1 & 6.5.2.

STEP A = =
STEP B SNAP-ON PR. PLATE
CONTINUOUS COVER PRESSURE
PVC BLOCK PLATE
3/32"X5/8"
BY OTHERS

PRESSURE PLATE
OPENING

OPENING
28.6mm

1 1/8''
27.3mm

1 1/16''
90
=

28.6mm
1 1/8''

TYPICAL DETAIL
SCREW PRESSURE OPENING OPENING

27.3mm
1 1/16''
#10 X 1 1/2" (38.1mm) PLATES 2 SETTING BLOCKS
@ 6" (152.4mm) BY OTHERS
BY OTHERS
LEAD-LINING
BY OTHERS

VARIES
INTERIOR INTERIOR

PRESSURE PLATE LEAD-LINED DOOR LEAD-LINED DOOR


44.5mm 44.5mm
BY OTHERS BY OTHERS
1 3/4'' 1 3/4''

STEP C STEP D
VISION CONTROL
MINI PANEL

VISION CONTROL
MINI PANEL

FAN-SHAPED
THUMBWHEEL

INTERIOR INTERIOR

R
Unicel Architectural Corp.
2155 Fernand-Lafontaine
Longueuil Qubec J4G 2J4 Canada
VC MINI 6.8.1
T: 800.668.1580 | 450.670.6844 F: 866.496.2628 | 450.670.7144 08-2017
E: unicel@unicelarchitectural.com www.unicelarchitectural.com
VISION CONTROL MINI
ARCHITECTURAL
INSTALLATION INSTRUCTIONS
X-RAY SHIELDING DOOR

FAN-SHAPED THUMBWHEEL OPERABLE ON ONE SIDE

STEP E STEP F
CONTINUOUS
PVC BLOCK
3/32"X5/8" BY OTHERS

VARIES
CUT-OUT

FAN-SHAPED DETAIL
FAN-SHAPED A
THUMBWHEEL
THUMBWHEEL
CUT-OUT
BY UNICEL
VARIES

VARIES
CUT-OUT
BY UNICEL

PRESSURE
PLATES

INTERIOR INTERIOR
A
SCREW
#10 X 1 1/2" (38.1mm)
@ 6" (152.4mm)
BY OTHERS
PRESSURE
PLATES

STEP G STEP H

SNAP-ON
COVER SNAP-ON SNAP-ON
COVER COVER
28.6mm
1 1/8''

NOTE:
ROTATION LIMITED TO
APPROX. 115 INSTEAD OF 180

115
VARIES

LOUVERS COME DOWN


FROM OPERABLE SIDE

CUT-OUT
BY UNICEL

INTERIOR
28.6mm
1 1/8''

CUT-OUT
BY UNICEL

R
Unicel Architectural Corp.
2155 Fernand-Lafontaine
Longueuil Qubec J4G 2J4 Canada
VC MINI 6.8.2
T: 800.668.1580 | 450.670.6844 F: 866.496.2628 | 450.670.7144 08-2017
E: unicel@unicelarchitectural.com www.unicelarchitectural.com
VISION CONTROL MINI
ARCHITECTURAL
INSTALLATION INSTRUCTIONS
FIRE-RATED DOOR

FAN-SHAPED THUMBWHEEL OPERABLE ON ONE SIDE


Install the operator according to pages 6.5.1 & 6.5.2.

STEP A REMOVE SCREWS AND STEEL TRIM LOCATED STEP B


ON THE SAME SIDE OF THE FIRELITE PLUS
GLAZING AND THEN REMOVE THE VISION
CONTROL UNIT FROM THE FRAME

44.5mm
1 3/4''
STEEL DOOR
CALCIUM SILICATE
BY OTHERS
DO NOT REMOVE
INTUMESCENT
MATERIAL

DOOR OPENING

CUT-OUT
FOR THE
FAN-SHAPED
THUMBWHEEL

ALUMINUM
FAN-SHAPED
THUMBWHEEL
OPERATOR

CALCIUM SILICATE
SETTING BLOCK

FIRELITE PLUS

R
Unicel Architectural Corp.
2155 Fernand-Lafontaine
Longueuil Qubec J4G 2J4 Canada
VC MINI 6.9.1
T: 800.668.1580 | 450.670.6844 F: 866.496.2628 | 450.670.7144 08-2017
E: unicel@unicelarchitectural.com www.unicelarchitectural.com
VISION CONTROL MINI
ARCHITECTURAL
INSTALLATION INSTRUCTIONS
FIRE-RATED DOOR

FAN-SHAPED THUMBWHEEL OPERABLE ON ONE SIDE

STEP C STEP D

44.5mm
1 3/4''

STEEL DOOR
BY OTHERS

THIS SIDE SHOULD BE


HELD IN PLACE BY A CALCIUM
WORKER TO
PREVENT THE UNITS SILICATE
FROM FALLING OUT.

ALUMINUM
FAN-SHAPED
THUMBWHEEL
OPERATOR ALUMINUM
FAN-SHAPED
THUMBWHEEL
OPERATOR

CALCIUM CALCIUM
SILICATE SILICATE
SETTING FIRELITE SETTING
BLOCK PLUS BLOCK

FIRELITE
PLUS

R
Unicel Architectural Corp.
2155 Fernand-Lafontaine
Longueuil Qubec J4G 2J4 Canada
VC MINI 6.9.2
T: 800.668.1580 | 450.670.6844 F: 866.496.2628 | 450.670.7144 08-2017
E: unicel@unicelarchitectural.com www.unicelarchitectural.com
VISION CONTROL MINI
ARCHITECTURAL
INSTALLATION INSTRUCTIONS
FIRE-RATED DOOR

CRANK HANDLE OPERABLE ON ONE SIDE


Test the functionality of the units by temporarily installing the operator and tightening the set screw. The mechanism is self-reversing and
should be tested as follows: Turn the operator in one direction (e.g. clockwise). When the louvers reach the closed position, continue turning
4-8 times in the same direction (e.g. clockwise) without fear of breaking the mechanism until the louvers eventually re-open. Complete two full
louver cycles by turning the operator in the same direction (e.g. clockwise). Repeat these steps in the opposite direction (e.g.
counter-clockwise) for two more full louver cycles.

STEP A REMOVE SCREWS AND STEEL TRIM LOCATED STEP B


ON THE SAME SIDE OF THE FIRELITE PLUS
GLAZING AND THEN REMOVE THE VISION
CONTROL UNIT FROM THE FRAME

44.5mm
1 3/4''
STEEL DOOR
CALCIUM SILICATE
BY OTHERS
DO NOT REMOVE
INTUMESCENT
MATERIAL

DOOR OPENING

STAINLESS STEEL
WORM GEAR SHAFT
HOLE
FOR THE
11.1mm CRANK HANDLE
7/16'' OPERATOR

CALCIUM SILICATE
SETTING BLOCK

FIRELITE PLUS

R
Unicel Architectural Corp.
2155 Fernand-Lafontaine
Longueuil Qubec J4G 2J4 Canada
VC MINI 6.10.1
T: 800.668.1580 | 450.670.6844 F: 866.496.2628 | 450.670.7144 08-2017
E: unicel@unicelarchitectural.com www.unicelarchitectural.com
VISION CONTROL MINI
ARCHITECTURAL
INSTALLATION INSTRUCTIONS
FIRE-RATED DOOR

CRANK HANDLE OPERABLE ON ONE SIDE

STEP C STEP D

44.5mm
1 3/4''

STEEL DOOR
BY OTHERS

THIS SIDE SHOULD BE


HELD IN PLACE BY A
WORKER TO
CALCIUM
PREVENT THE UNITS SILICATE
FROM FALLING OUT.

FOLDABLE ZINC
CRANK HANDLE

TIGHTEN
SET SCREW

OVAL
PLATE

CALCIUM CALCIUM
SILICATE SILICATE
SETTING SETTING
BLOCK BLOCK

FIRELITE
PLUS

R
Unicel Architectural Corp.
2155 Fernand-Lafontaine
Longueuil Qubec J4G 2J4 Canada
VC MINI 6.10.2
T: 800.668.1580 | 450.670.6844 F: 866.496.2628 | 450.670.7144 08-2017
E: unicel@unicelarchitectural.com www.unicelarchitectural.com
VISION CONTROL MINI
ARCHITECTURAL
INSTALLATION INSTRUCTIONS
SLIDING DOOR

FLAT KNOB OPERABLE ON ONE SIDE


Test the functionality of the units by temporarily installing the operator and tightening the set screw. The mechanism is self-reversing and
should be tested as follows: Turn the operator in one direction (e.g. clockwise). When the louvers reach the closed position, continue turning
4-8 times in the same direction (e.g. clockwise) without fear of breaking the mechanism until the louvers eventually re-open. Complete two full
louver cycles by turning the operator in the same direction (e.g. clockwise). Repeat these steps in the opposite direction (e.g.
counter-clockwise) for two more full louver cycles.

STEP A STEP B 4 STEP C


GLAZING GASKET
SUPPLIED BY UNICEL
UNIVERSAL TRIMS
SUPPLIED BY UNICEL 5
VISION CONTROL
1
MINI PANEL GLAZING GASKET
SUPPLIED BY UNICEL
SCREW
BY OTHERS

VARIES
2

THIS SIDE
VISION CONTROL SHOULD BE
9.4mm
MINI PANEL HELD IN PLACE
3/8'' BY A WORKER
TO PREVENT
THE UNIT FROM
FALLING OUT
VARIES

VARIES
3 34.9mm
SETTING BLOCKS 1 3/8''
BY OTHERS
SLIDING DOORS STAINLESS STEEL
BY OTHERS WORM GEAR SHAFT

STEP D STEP E STEP F STEP G


6
UNIVERSAL
SNAP-ON
MOLDING
SUPPLIED
BY UNICEL
9
TIGHTEN
SET SCREW

STAINLESS 7
STEEL WORM
GLAZING
GEAR SHAFT
GASKET
SUPPLIED
BY UNICEL
38.1mm
1 1/2''
11.1mm
7/16''

ADD SHIMS
BY OTHERS FLAT KNOB
8

HOLE
BY UNICEL

R
Unicel Architectural Corp.
2155 Fernand-Lafontaine
Longueuil Qubec J4G 2J4 Canada
VC MINI 6.11
T: 800.668.1580 | 450.670.6844 F: 866.496.2628 | 450.670.7144 08-2017
E: unicel@unicelarchitectural.com www.unicelarchitectural.com
VISION CONTROL MINI
ARCHITECTURAL
INSTALLATION INSTRUCTIONS
SLIDING DOOR

FAN-SHAPED THUMBWHEEL OPERABLE ON ONE SIDE


Install the operator according to pages 6.5.1 & 6.5.2.

STEP A STEP B 4 STEP C


GLAZING GASKET
SUPPLIED BY UNICEL
UNIVERSAL TRIMS
SUPPLIED BY UNICEL 5
VISION CONTROL
1
MINI PANEL GLAZING GASKET
SUPPLIED BY UNICEL
SCREW
BY OTHERS

VARIES
2

THIS SIDE
VISION CONTROL SHOULD BE
MINI PANEL HELD IN PLACE
BY A WORKER
TO PREVENT
THE UNIT FROM
FAN-SHAPED FALLING OUT
THUMBWHEEL
VARIES

VARIES
3 34.9mm
SETTING BLOCKS 1 3/8''
BY OTHERS
FAN-SHAPED
SLIDING DOORS THUMBWHEEL
BY OTHERS

STEP D STEP E STEP F STEP G


6
UNIVERSAL
SNAP-ON
MOLDING
SUPPLIED
BY UNICEL
BY UNICEL
CUT-OUT

FAN-SHAPED
THUMBWHEEL 7
GLAZING
3.2mm
GASKET
1/8''
SUPPLIED
BY UNICEL

ADD SHIMS
BY OTHERS

R
Unicel Architectural Corp.
2155 Fernand-Lafontaine
Longueuil Qubec J4G 2J4 Canada
VC MINI 6.12
T: 800.668.1580 | 450.670.6844 F: 866.496.2628 | 450.670.7144 08-2017
E: unicel@unicelarchitectural.com www.unicelarchitectural.com
VISION CONTROL MINI
ARCHITECTURAL
OPERATION AND MAINTENANCE

MAINTENANCE INSTRUCTIONS

Cleaning and maintenance of glass:

Routinely clean using ordinary window-washing techniques.

For best results, use liquid glass cleaners or mild household detergents. Do not use cleaning
compounds containing fluorine, strong acids, corrosive alkaline detergents or from glass
surfaces.

Cleaning and maintenance of zinc crank handle, aluminum knobs, or plastic thumbwheel:

If the crank handle or knob becomes loose, just tighten the allen screw with an allen key on
the side of the crank handle or knob.

Clean the crank handle with liquid glass cleaners and thumbwheel with cleaners used for polymer.

Cleaning and maintenance of aluminum blocks, oval plates, knobs, and aluminum trims:

Mild soaps or detergents ruled safe for bare hands should be safe for coated aluminum. Stronger
detergents such as some dishwasher detergents should be carefully spottested. After cleaning,
the finish should be thoroughly rinsed with clean water and dried.

Avoid abrasive cleaners. Strong solvents or strong cleaner concentrations can cause damage to
painted surfaces. Overcleaning or excessive rubbing can do more harm than good.

Abrasive materials such as steel wool and abrasive brushes can wear and harm finishes. Do not
scour painted surfaces.

Never use paint removers, aggressive alkaline, acid or abrasive cleaners. Do not use trisodium
phosphate, highly alkaline or highly acid cleaners. Always do a test surface.

R
Unicel Architectural Corp.
2155 Fernand-Lafontaine
Longueuil Qubec J4G 2J4 Canada
VC MINI 7.1
T: 800.668.1580 | 450.670.6844 F: 866.496.2628 | 450.670.7144 08-2017
E: unicel@unicelarchitectural.com www.unicelarchitectural.com
VISION CONTROL MINI
ARCHITECTURAL
WARRANTY STATEMENT

During a period of twenty (20) years from date of manufacture, depending on the type of unit
construction and the use to which the unit is put, Vision Control Mini insulating glass units installed
in interior applications are warranted not to develop, under normal conditions, material obstruction of
vision as a result of dust or film formation on the internal glass surface caused by failure of the
hermetic seal other than through glass breakage. Additionally, this warranty covers any internal parts
for malfunction, mechanical failure or premature wear under normal use. Motorized elements are
covered up to a one (1)-year period. Glass edge separation, changes in properties of interlayer,
delamination of glass, glass coatings, and material obstruction through glass not caused by seal
failure, are not covered beyond the warranty period offered by the original supplier of glass. This
warranty does not apply to glass breakage or vandalism, and does not cover replacement and labor
costs. Units installed in exterior applications and without breather tubes or capillary breather tubes
are covered up to a ten (10)-year period.

This warranty is effective only if installation is made in accordance with Unicel's specific instructions
and does not apply to units damaged by improper handling or installation. This represents Unicel's
maximum liability. The obligations of Unicel under this warranty are limited to the repair or
replacement, at Unicel's option, of defective parts of the goods, Ex-Works our plant. This warranty
does not apply to replacement units beyond the original twenty (20)-year (or ten (10)-year) period to
which the original unit is subjected. Unicel will not be liable for any other expenses involved in the
removal of defective units, installation of replacement units, or any other incidental or consequential
damages.

Unicel does not authorize any person, dealer, or distributor to create for it any obligation or liability in
connection with the goods. Leakage will be the sole responsibility of the glass contractor or installer.

This warranty shall be void if the units are subjected to abnormal stresses from the load application
of heat, excessive vibration, building or foundation movement; if glazed with materials which do not
remain resilient for the life of the warranty, or if the methods and materials used in glazing the units
do not completely repel water for the life of the warranty. Unicel reserves the right to inspect, in the
field, any part or unit which is allegedly defective, or to request that the unit(s) be returned to Unicel
for inspection.

This warranty is valid only if contracts have been paid in full.

Unicel Architectural Corp.

R
Unicel Architectural Corp.
2155 Fernand-Lafontaine
Longueuil Qubec J4G 2J4 Canada
VC MINI 7.2
T: 800.668.1580 | 450.670.6844 F: 866.496.2628 | 450.670.7144 08-2017
E: unicel@unicelarchitectural.com www.unicelarchitectural.com

S-ar putea să vă placă și