Sunteți pe pagina 1din 10

Calculation of Wind pressure on various glass and window frame

Design wind speed = Vb X K1 X K2 X K3

basic wind speed (Vb)= 39 m/s


table 1
probabilty factor (K1)= 1 IS 875
general buildings part3
and structures Mean
Probable 50 years
design life of
structure in
years .
table 2
terrain, height and structure size factor (K2)= 1 IS 875
Category 2 Open
terrain with part3
wellscattered
obstructions having
height
generally between
1.5 and 10 m.
he value of k3 may IS 875
topography factor (K3)= 1.36 be taken to be equal
part 3
to 1.0. The value of para
k3 is confined in the 5.3.3.1
range of 1.0 to 1.36
for slopes greater
than 3o .
Vz= 53.04 m/s

Design wind pressure= (1/2)*p*(Vz)^2

density of air (p)= 1.2 kg/m^3(para 9.1 sp 64)

Pz= 1687.9 N/m^2

wind load calculation= Cf X A X Pd

(table 24 IS
Force coefficient (Cf)= 1.2 875 part3 )
surface area of structure (A)= 0.5174074 1987
design wind pressure (Pd)= 1687.945

F= 1048 N/m2

length 0.73333 l/b= 1.0393701


breadth 0.70556
Properties of toughened glass

Toughened
Properties
Glass
Thermal Shock
Up to 250C
Resistance

Four to five
times stronger
Mechanical Strength
than annealed
glass

Tensile Strength 65 MPa


120-200
Bending Strength
N/mm2
Surface Compression > 95 MPa

Design Stress for


Architectural 50 MPa
Purposes
Small round
Fragmentation
crystals
Cannot be cut
Conducive for
after
Processing
Toughening

Calculation of loads

MATERIAL STRENGTH OF 6063-T6 ALLOY BASED ON IS 8147-1976


1 Permissible bending stress in tension and compression (sc,st) 960 kg/cm2
2 Permissible bending stress in shear 510 kg/cm2
3 permissible Bearing stress 1390 kg/cm2
4 0.2% proof stress for 63400(H9) WP as per IS 1847-1976 1550 kg/cm2
5 Elastic Modulus 700000 kg/cm2
6 Density 27.1 kN/m3
7 Poisson's ratio 0.23
8 Wind Pressure 1.048 kPa

SECTIONAL PROPERTIES OF THE OUTER FRAME SECTION -DDW111

1 Design UDL on the outer frame = 0.7592 kn/m


2 Maximum Bending Moment in outer frame = 0.05 kn-m

Permissible Bending stress for 6063 - T6 alloy which comes to 960 kg/cm2 as per IS 8147-1976 Table 4

3 Section Modulus required by the vertical frame = 0.01 cm3


4 Section Modulus provided by the vertical frame = 8.5E-09 cm3
### < 0.01 cm3
sigma= M/Z 8.4829091E-09

Z= I/y where I= (b/d^3)/12 35365


thickness of
5894204.3896 y= ### glass= 0.012

It is not safe in Bending stress