Konica-Minolta bizhub C654 Error Codes List page 1 from 15

1 Code:
All codes

Code: C0002

Description:

Paper feed communication error


When the paper feed/transport drive board (PFTDB) is receiving data, a communication error is
detected.

Remedy:

1 Turn OFF the main power switch, disconnect and then connect the power cord. Wait for 10 sec. or
more after connect the power cord, and turn ON the main power switch. 2 Rewrite the firmware. 3
PFTDB ICP3 conduction check. 4 PRCB ICP16 conduction check. 5 Replace PFTDB. 6 Replace
PRCB.

Code: C0104

Description:

Tray 3/4 feeder transportation motor failure to turn


The lock signal remains HIGH for a predetermined continuous period of time while the motor is
turning.

Remedy:

1 Check the connector between M25-PFTDB CN17 for proper connection and correct as necessary.
2 Check the connector of M25 for proper drive coupling and correct as necessary. 3 M25 operation
check PFTDB CN17-1 to 7 11-X. 4 Replace M25. 5 PFTDB ICP6 conduction check. 6 Replace
PFTDB. 7 Replace PRCB.

Code: C0105

Description:

Tray 3/4 feeder transportation motor turning at abnormal timing


The lock signal remains LOW for a predetermined continuous period of time while the motor remains
stationary.

https://printcopy.info/?l=en&mod=erc&brand=Konica-Minolta&model=bizhub%20C654 1/4
13/9/2017 Error Codes > Konica-Minolta > bizhub C654 > page 1

Remedy:

1 Check the connector between M25-PFTDB CN17 for proper connection and correct as necessary.
2 Check the connector of M25 for proper drive coupling and correct as necessary. 3 M25 operation
check PFTDB CN17-1 to 7 11-X. 4 Replace M25. 5 PFTDB ICP6 conduction check. 6 Replace
PFTDB. 7 Replace PRCB.

Code: C0202

Description:

Tray 1 feeder up/down abnormality


The tray 1 upper limit sensor (PS6) is not blocked even after the lapse of a given period of time after
the lifting motion has been started

Remedy:

1 Check the connector between M6-PFTDB CN27 for proper connection and correct as necessary. 2
Check the connector of M6 for proper drive coupling and correct as necessary. 3 Check the connector
between PS6-relay CN145- PFTDB CN15 for proper connection and correct as necessary. 4 PS6 I/O
check, sensor check PFTDB CN15-3 (ON) 1-P 5 M6 operation check PFTDB CN27-10 to 11 2 to 3-X.
6 Replace M6. 7 Replace PFTDB. 8 PRCB ICP10 conduction check. 9 Replace PRCB.

Code: C0204

Description:

Tray 2 feeder up/down abnormality


The tray 2 upper limit sensor is not blocked even after the lapse of a given period of time after the
lifting motion has been started.

Remedy:

1 Check the connector between M8-PFTDB CN26 for proper connection and correct as necessary. 2
Check the connector of M8 for proper drive coupling and correct as necessary. 3 Check the connector
between PS14-relay CN155BPFTDB CN14 for proper connection and correct as necessary. 4 PS14
I/O check, sensor check PFTDB CN14-9 (ON) 4-P. 5 M8 operation check PFTDB CN26-10 to 11 4-X.
6 Replace M8. 7 PFTDB ICP10 conduction check. 8 Replace PFTDB. 9 Replace PRCB.

Code: C0206

Description:

Tray 3 feeder up/down abnormality


The tray 3 upper limit sensor is not blocked even after the lapse of a given period of time after the
lifting motion has been started.

Remedy:

1 Check the connector between M23-PFTDB CN18 for proper connection, and correct as necessary.
2 Check the connector of M23 for proper drive coupling and correct as necessary. 3 Check the
connectors between PS22-relay CN193- relay CN113B-PFTDB CN20 for proper connection, and
correct as necessary. 4 PS22 I/O check, sensor check PFTDB CN20-6 (ON) 6-X. 5 M23 operation
check PFTDB CN18-3 to 4 9-X. 6 Replace M23. 7 PFTDB ICP7 conduction check. 8 Replace PFTDB.
9 Replace PRCB.

Fast & Free Colocation Quotes Top


Top Colocation Pricing Ranked Colocation Providers

Code: C0208

Description:

https://printcopy.info/?l=en&mod=erc&brand=Konica-Minolta&model=bizhub%20C654 2/4
13/9/2017 Error Codes > Konica-Minolta > bizhub C654 > page 1

Tray 4 feeder up/down abnormality


The tray 4 upper limit sensor is not blocked even after the lapse of a given period of time after the
lifting motion has been started.

Remedy:

1 Check the connector between M24-PFTDB CN18 for proper connection and correct as necessary.
2 Check the connector of M24 for proper drive coupling and correct as necessary. 3 Check the
connector between PS27-relay CN194-relay CN121B-PFTDB CN22 for proper connection and
correct as necessary. 4 PS27 I/O check, sensor check PFTDB CN22-6 (ON) 8-X. 5 M24 operation
check PFTDB CN18-1 to 2 9-X. 6 Replace M24. 7 PFTDB ICP8 conduction check. 8 Replace PFTDB.
9 Replace PRCB.

Code: C0216

Description:

LCT up/down abnormality


The upper limit sensor (PS2) is not blocked even after the set period of time has elapsed after the
paper lift-up operation began

Remedy:

When LU-204 is installed: 1 Check the connector between M1-LCDB CN3 for proper connection, and
correct as necessary. 2 Check the connector of M1 for proper drive coupling and correct as
necessary. 3 Check the connectors between PS2-relay CN406- LCDB CN5 for proper connection,
and correct as necessary. 4 PS2 I/O check, sensor check LUDB CN5-3 (ON) LU-204 4-G. 5 M1
operation check LUDB CN3-4 (ON) LU-204 3-G. 6 Replace M1. 7 LUDB ICP2 conduction check. 8
Replace LUDB.
When LU-301 is installed: 1 Check the connector between M1-LCDB CN3 for proper connection, and
correct as necessary. 2 Check the connector of M1 for proper drive coupling and correct as
necessary. 3 Check the connectors between PS2-relay CN3-LCDB CN5 for proper connection, and
correct as necessary. 4 PS2 I/O check, sensor check LUDB CN5-3 (ON) LU-301 4-G. 5 M1 operation
check LUDB CN3-4 (ON) LU-301 3-G. 6 Replace M1. 7 LUDB ICP2 conduction check. 8 Replace
LUDB.

Code: C0301

Description:

Suction fans failure to turn


The fan lock signal remains HIGH for a predetermined continuous period of time while the fan is
turning.

Remedy:

1 Check the connector between FM1-relay CN278-relay CN271B-PFTDB CN10 for proper connection
and correct as necessary. 2 Check the fan for possible overload and correct as necessary. 3 FM1
operation check PFTDB CN10-3 (REM) PFTDB CN10-5 (LOCK) 5-P. 4 Replace FM1. 5 PFTDB ICP2
conduction check. 6 Replace PFTDB.

Code: C0351

Description:

Paper cooling fan/ins failure to turn


The fan lock signal remains HIGH for a predetermined continuous period of time while the fan is
turning.

Remedy:

1 Check the connector between FM13-relay CN325- PRCB CN1 for proper connection and correct as
necessary. 2 Check the fan for possible overload and correct as necessary. 3 FM13 operation check
PRCB CN1-11 (LOCK) 7-K. 4 Replace FM13. 5 Replace PRCB.
https://printcopy.info/?l=en&mod=erc&brand=Konica-Minolta&model=bizhub%20C654 3/4
13/9/2017 Error Codes > Konica-Minolta > bizhub C654 > page 1

Code: C1003

Description:

PK communication error
<When FS-535+PK-521 is installed> When a communication error is detected between the FS
control board (FSCB) and the punch control board (PKCB).

Remedy:

1 Turn OFF the main power switch, disconnect and then connect the power cord. Wait for 10 sec. or
more after connect the power cord, and turn ON the main power switch. 2 Rewrite the firmware. 3
Replace PKCB. 4 Replace FSCB.

Code: C1004

Description:

FNS communication error


When the FS control board (FSCB) is receiving data, a communication error is detected.

Remedy:

1 Turn OFF the main power switch, disconnect and then connect the power cord. Wait for 10 sec. or
more after connect the power cord, and turn ON the main power switch. 2 Rewrite the firmware. 3
Replace FSCB (FS-534/FS-535)