D e p a r t m e n t o f FORM 1-4-Calculation Sheets


Chemical Engineering
Talamban, Cebu City, Philippines 6000
Energy Requirement 1

DESIGNER(S): CHATO, REIZL JANE A.


CUEVAS, CAPE CARYL R.
NAVALTA, CARL JOHN LOUIE G.
RABOY, VON ADRIAN O.

Equipment Tag: H-01


Equipment Description: Heat Exchanger
Calculation Sheet No: PED-C002

DESIGN MANUALS OR TECHNICAL REFERENCES

[1] Santos JCO, Santos MGO, Dantas JP, Conceio MM, Athaide-Filho PF, Souza a. G.
Comparative study of specific heat capacities of some vegetable oils obtained by DSC and
microwave oven. J Therm Anal Calorim 2005;79:2837. doi:10.1007/s10973-005-0050-x.

DESCRIPTION

The heat exchanger will be used to pre-heat the rice bran oil from room temperature (30 C) to 90 C, for the
purpose of decreasing the viscosity of the rice bran oil from. Pre-heating the rice bran oil will aid in the transport of
rice bran oil from its storage to the fluidized bed reactors with less amount of pumping requirements.

ASSUMPTION(S)/BASIS
1. Steady state.
2. The reference temperature used to calculate for the enthalpy of a specific stream is 0 C.
3. No reaction along the pipes reaction only occur at the reactors.

NOMENCLATURE(S)

Symbol or Notation Description


Mass flowrate of feed triglyceride (TG) entering the
heat exchanger, kg/h
Heat capacity of rice bran oil (RBO) at specified T,
,()
kJ/kg-K
Reference temperature (0 C)
1 Temperature of RBO entering the heat exchanger, C
2 Temperature of RBO exiting the heat exchanger, C
Heat flowrate of feed entering the heat exchanger,
1 kJ/h
1 Heat flowrate of RBO exiting the heat exchanger, kJ/h
Heat required to raise the temperature of the entering
01
feed, kJ/h

INFORMATION FLOW DIAGRAM


,(30 ) ,(90 )

1 2

1 = ,(30 ) (1 ) 1 = ,(90 ) (2 )

1 1

01 = 1 1

01

SYSTEM SKETCH
1
RBO (TG) (kg/h) 11435.88
Temperature (K) 303.15
Pressure (MPa) 6.5

3
RBO (TG) (kg/h) 11435.88
Methanol (kg/h) 2482.84
2 Temperature (K) 363.15
Methanol (kg/h) 2482.84 Pressure (MPa) 6.5
Temperature (K) 303.15
Pressure (MPa) 6.5
CALCULATIONS

Overall balance around the heat exchanger (H-01) (Equation 1):


= 1 1 + Equation 1


at steady state,
=0

0 = 1 1 +

The heat required to raise the temperature of the entering stream is calculated using Equation 2.

01 = 1 1 Equation 2

Calculating for 1 (Equation 3):

1
1 = Equation 3

The heat capacity of the rice bran oil (RBO) is estimated based on the results from the study of [1].

303.15
1 = ,(30 ) (1 ) +
273.15


1 = (11435.88 ) (1.74 ) (303.15 273.15)

303.15
1
+ (2482.84 )( ) (8.314 ) (13.431 51.28 103
32.04 273.15
+ 131.13 106 2 ) Commented [LN1]: Kulang gas constant


= .

Calculating for 1 (Equation 4):

2
1 = Equation 4

363.15
1 = ,(90 ) (2 ) +
273.15

1 = (11435.88 ) (2.045 ) (363.15 273.15)

363.15
1
+ (2482.84 )( ) (8.314 ) (13.431 51.28 103
32.04 273.15
+ 131.13 106 2 ) Commented [LN2]: Kulang gas constant


= .

Calculating for 01

01 = 1 1


01 = 2712312.54 781579.69

1
01 = 1930732.85 ( )
3600

= .

RESULTS AND CONCLUSION

The amount of heat required (heat exchangers duty) to heat the rice bran oil from 30 C to 90 C is 536.31 kW.

COMPUTER PROGRAMS USED (Version No.) N/A


ELECTRONIC CALCULATION FILE NAME: N/A

APPVD
REV DATE REVISION DESCRIPTION BY CHKD BY
BY
A 09/01/2017 First Draft CJLN
B 09/11/2017 Second Draft CJLN