Sunteți pe pagina 1din 1

PODET DALAT (L=2.

00m)
DETALIU DE POZARE A ELEVATIEI
SECTIUNE LONGITUDINALA A-A Sc.1:25
Sc.1:100
B C 50 30 70

Ax drum
Imbracaminte
Dala marginala tip D3 C35/45

Hidroizolatie Bp/2 Bp/2


p% p% Dale prefabricate curente tip D3 C30/37

Aripa prefabricata tip A2 C30/37

80
ha= 2.80

1.60
Elevatie tip L1 C30/37

H
15
6 29

30
i%
1.00

C30/37

20
20
1.00

Saltea din piatra bruta


60
Pinten beton C30/37 2

Af
Mortar de poza 2cm

C12/15
1.90 10 la=3.10 Lf la=3.10 10 1.90 L=1.20m G=3.70Kg
B
C
VEDERE B-B SECTIUNE TRANSVERSALA C-C
Sc.1:50 Sc.1:50
NOTA :
- Elementele tip L se vor aseza joantiv pe blocul de fundatie pe un strat de
A mortar de ciment M100 pentru nivelare si pozare (2cm).
Timpan prefabricat
Beton de panta Imbracaminte - Rosturile de 1 cm dintre elemente se vor mata cu mortar de ciment M 100
(Dala marginala tip D3) 2.90/2 (C12/15) - Hidroizolatia se va realiza conform prevederilor din plansa de detaliu
Hidroizolatie
Dala tip D3

C30/37 Sistem rutier

2.00/2 CERINTE PENTRU ASIGURAREA DURABILITATII


Hidroizolatie
LUCRARILOR DIN BETON CONFORM CP 012/1-2007:
Dren din piatra bruta zidita
Aripa tip A2 FUNDATIE PODET,
DENUMIRE ELEMENT CUNETA PINTEN, PEREU
AX PODET

DALE CURENTE DALE MARGINALE


Elevatie
tip L1 CLASA DE REZISTENTA A BETONULUI C 12/15 C 30/37 C 30/37 C 30/37 C 35/45

CLASA DE EXPUNERE X0 XC4+XD1+XF2 XF4 XC3+XD1+XF3 XC4+XD3+XF4


50
H

DOZAJ MIN DE CIMENT (kg/mc) 250 300 340 300 340


Cuneta dren
min.40
100

3% CEMII/A,B-S;A,B-V; CEMI; SRI; CD40; CEMI; SRI; CD40; CEMI; SRI; CD40; CEMI; SRI; CD40;
TIPUL CIMENTULUI A,B-LL;A,B-L;CEMIII/A CEMII/A,B-S;A-LL; CEMII/A,B-S;A-LL; CEMII/A,B-S;A-V;A-LL; CEMII/A,B-S;A-LL;

RAPORT APA/CIMENT(max) 0.65 0.55 0.50 0.55 0.45


C30/37
5
5 80 variabil 5
100

Pereu din piatra bruta pe beton (C30/37)


15
Af

C12/15

A 2.00

BENEFICIAR : PROIECTANT: DRENAJ


ing. Alexandru BUCUR
COMPANIA NATIONALA DE MANAGER PROIECT :
1:100 DETALIU TIP 2
AUTOSTRAZI SI DRUMURI ing. Florin DOBRIN 1:50 PODET DALAT L=2.00m
NATIONALE DIN ROMANIA ing. Florin DOBRIN 1:25
FAZA SECTIUNE / OBIECT REV. LIMBA
STUDIU DE FEZABILITATE NUMAR SECVENTIAL
VERIFICATOR INTERN : ing. Emil GEORGESCU SF D R 0 0 1 D T 0 0 2 A 1 R

S-ar putea să vă placă și