SELECTION CRITERIA FLOW CHART FOR ELECTRIC HEAT TRACER TYPE

PIPELINES
OR TANKS
TANKS

PIPELINE

SEPARATE INDIVIDUAL LENGTHS WITH


LONGLINE(>2km) MULTIPLE POWER LOCATIONS / INDIVIDUAL
OR SHORTLINE (< LENGTH UPTO M
SINGLE LONG LINE
2 km) (PROCESS
LINE)

POWER AVAILABLE POWER AVAILABLE AT


SERIES/PARALLEL
AT LIMITED MULTIPLE LOCATION
CIRCUIT
LOCATION ALONG P/L

>180C TEMPERATURE 150C TO 180C


MAINTAINANCE/
EXPOSURE ( <150C )

POWER LIMITING
<150C

CHECK IF
SPECIFIED TRACER TYPE NOT SPECIFIED
PARALLEL MI CABLE SPECIFIED IN
CIRCUIT AHT REFER DESIGN ENQUIRY

INTERNATIONAL NO
APPROVALS REQUIRED

YES
POWER CW PARALL EL
LIMITING CIRCUIT SLSR

PIPE LENGTH PIPE LENGTH


FROM 500 Mtr TO NO CHECK IF CUSTOMER
ABOVE 5000 Mtr
5000 Mtr HAS EARLIER USED
XICON'S HTS PRODUCTS

YES
SKIN EFFECT 2P/3P LONG LINE

OFFER MTS OFFER HTS

CHECK EXP TEMP SPECIFIED


CHECK EXP TEMP SPECIFIED CHECK EXP TEMP SPECIFIED CHECK MAINT. TEMP SPECIFIED
CHECK MAINT. TEMP SPECIFIED CHECK MAINT. TEMP SPECIFIED CHECK T - RATING SPECIFIED
CHECK T - RATING SPECIFIED CHECK T - RATING SPECIFIED

SELECT FROM
SELECT FROM CHART SELECT FROM CHART CHART ENCLOSED BASED ON EXP.
ENCLOSED BASED ON EXP. ENCLOSED BASED ON EXP. TEMP. CRITERIA
TEMP. CRITERIA TEMP. CRITERIA

LIMIT TRACER OUTPUT LIMIT TRACER OUTPUT LIMIT TRACER OUTPUT


TO MAINTAIN T - RATING AS PER TO MAINTAIN T - RATING AS TO MAINTAIN T - RATING AS PER CHART
CHART ENCLOSED PER CHART ENCLOSED ENCLOSED