Documente Academic
Documente Profesional
Documente Cultură
RESUMO
ABSTRACT
Evaluation of efficiency of dissolved air flotation system in bench scale, combined different
dosages of ionic polymers, with isolated application or associated to ferric chloride, to the
post-treatment effluent of the Sideral Wastwater Treatment Plant (WTP), managed by the
Sanitation Company of the State of Par (COSANPA), in Belm/PA. The assays of flotation
have been divided by serials: Serial A, without utilization of chemical product; Serial B, with
utilization of ionic polymers as primary coagulant; and Serial C, with application of ionic
polymers associated with ferric chloride. In experimental tests without chemical product's
addition (Serial A) the removals have been of 30,24 and 31,12 % to apparent color and
turbidity, respectively. The major percentages of removals from Serial B have been observed
for dosage 8 g/m of cationic polymer (88,81 % to apparent color and 70,12% to turbidity),
and the application of anionic polymer has resulted in lowers removals for all dosages, have
been the major percentages 16,88 % to dosage 1 g/m and 9,35% to 8 g/m, in the removal of
apparent color and turbidity, respectively. On the Serial C, to the combined 30 g/m of ferric
chloride and 2 g/m of cationic polymer, has been observed the majors percentages of
removals from this research (79,27% to apparent color and 92,65% to turbidity), however, the
association 30 g/m of ferric chloride and 1 g/m of cationic polymer has been indicated by its
highest results of removal, applying half of the dosage that has given the best removal. The
results from this research indicates alternatives to the post-treatment in WTPs run by
COSANPA, in Belm, and it will be used in the routine adjustment of WTP Tavares Bastos
flotation system.
INTRODUO
MATERIAL E MTODOS
RMB
j
ra
PARQUE GUAJARA
Ma
de
a
Ba
120' BELM
120'
STA. BRBARA DO PAR
Baa de Santo
Antnio
N
ANANINDEUA
Guaj ar
BENEVIDES
W E
E
T O
NNE
P
A Q
RUE
GUA
J A
RA
Baa do
A
T P
A A
N
O
CQE
URI O
P
RAT N
I A
H
S
A O
P
A Q
RUE
V E D
RE
L
CEME T
NE
A
CBA NA
GEM N
UA
B
E G
NUI
V
A D
L E CA
NS
MARITUBA
S
A
MGNUE
I A
RO
TAPANA
121' Rio Guam
COQUEIRO 121'
ACAR
PRATINHA
SAO PARQUE VERDE
CLEMENTE
122' 122'
UNA
CABANAGEM
BENGUI
VAL DE CANS
123' MANGUEIRAO 123'
ETAPAS DA PESQUISA
A pesquisa foi desenvolvida em trs etapas apontadas na Figura 3.
A
B
C
Figura 4 (a) Coleta de amostras no canal de entrada da ETE Sideral; (b) Coleta de
amostras na canaleta de sada do reator UASB
A medio de temperatura das amostras foi realizada no local da coleta, para garantir
condio similar na execuo dos ensaios experimentais de flotao, sendo as demais
determinaes realizadas no LCR/UFPA.
Figura 6 (a) Jarro para teste com bandeja de distribuio; (b) Detalhe ampliado da bandeja
RESULTADOS OBTIDOS
Determinao
Amostra Alcalinidade Cor
Turbidez Slidos Sed. Temp.
pH (mg Aparente
(u. T.) (g/m) (C)
CaCO3/L) (u. H.)
E.B. 7,47 104 895 170 2 27,8
E.T. 7,20 92 343 57 < 0,5 27,7
Determinao
Amostra Alcalinidade Cor
Turbidez Slidos Sed. Temp.
pH (mg Aparente
(u. T.) (g/m) (C)
CaCO3/L) (u. H.)
E.B. 7,2- 7,7 268-352 2070-1140 118-278 1-1,5 25-26
E.R. 6,9-7,6 260-290 800-300 35-58,8 < 0,1 23-25
Tabela 6 Resultados das determinaes laboratoriais de Cor Aparente dos ensaios de flotao
50,00
0,00
-50,00
8 6 4 2 1 0,5
PC: FAD 70,12 61,07 45,43 2,81 -4,52 -23,57
PA: FAD 0,25 -4,17 5,02 -35,31 16,88 -30,58
PC: UASB+FAD 92,38 90,07 86,08 61,21 58,28 50,68
PA: UASB+FAD 74,56 73,43 75,77 58,44 74,47 59,89
Dosagem (g/m)
Remoo de Turbidez
150,00
Eficincia (%)
100,00
50,00
0,00
-50,00
8 6 4 2 1 0,5
Dosagem (g/m )
0 10 20 30 40 50 60 70 80 90 100
Eficincia (%)
Figura 12 Remoo de Cor Aparente para as DCF e DPC testadas
Remoo de Turbidez
FAD Global (UASB+FAD)
94,45
DCF=30 g/m; DPC= 0,5 g/m 85,12
96,46
DCF=30 g/m; DPC= 1 g/m 90,50
97,26
DCF=30 g/m; DPC= 2 g/m 92,65
0 10 20 30 40 50 60 70 80 90 100
Eficincia (%)
Figura 13 Remoo de Turbidez para as DCF e DPC testadas
Ao trmino dos ensaios, o volume de amostra nos jarros foi transferido para um balde
e, ento, descartado. Nesse procedimento de rotina foi percebido visualmente a consistncia
do lodo produzido quando empregado polmero catinico e cloreto frrico. Na Figura 14 pode
ser observada a amostra da referida situao, sendo descartada aps o ensaio.
DCF=90 g/m;
8,27
DPA= 1 g/m 71,83
31,46
DCF=30 g/m;
72,64
DPA= 1 g/m
-40 -20 0 20 40 60 80
Eficincia (%)
Figura 15 Remoo de Cor Aparente para as DCF e DPA testadas
-20 0 20 40 60 80 100
Eficincia (%)
Figura 16 Remoo de Turbidez para as DCF e DPA testadas
Srie A
0 20 40 60 80 100
Eficincia (%)
Figura 17 Percentuais de remoo de Cor Aparente nas Sries de ensaio 1, 2 e 3
0 20 40 60 80 100
Eficincia (%)
Figura 18 Percentuais de remoo de Turbidez nas Sries de ensaio 1, 2 e 3
Os ensaios da Srie A representados nos dois grficos anteriores apresentaram
percentuais de remoo de Cor aparente de 87,08 e 30,24 % e de 82,43 e 31,12 % para
remoo de Turbidez, os percentuais obtidos considerando eficincia global (UASB+FAD) e
a da FAD, respectivamente.
CONSIDERAES FINAIS
PALAVRAS-CHAVE
AGRADECIMENTOS
Ao Grupo de Pesquisa Hidrulica e Saneamento da Universidade Federal do Par.
Ao Conselho Nacional de Desenvolvimento Cientfico e Tecnolgico.
REFERNCIAS
[6] MORETTI, Renata Cristina. Aplicao da flotao para clarificao final do efluente
de um sistema de tratamento de esgoto sanitrio constitudo de reatores anaerbios
(UASB) seguidos de lagoa aerada. In: CONGRESSO BRASILEIRO DE ENGENHARIA
SANITRIA E AMBIENTAL, 21. Paraba, SE, ABES: Anais eletrnicos. 2001.