The scope of this report is to present the structural design of the Base plate for the platform columns
and Staircase stinger beams.
The design of the civil/structural works will be in accordance with the following laws, rules and
applicable standards:
1.4 MATERIALS
m = (N-0.95d)/2
= 2.325 in
n = (B-0.8bf)/2
= 2.39 in
n' = (d x bf)/4
= 0.512 in
X =
= 0.543
= (2 x X) / (1+((1-X)) 1
= 0.88
Tensile force = 0 kN
The tensile force is zero & the shear forces values are very small
Hence the fasteners are required only for the fixing purpose of the column.
m = (N-0.95d)/2
= 2.35 in
n = (B-0.8bf)/2
= 2.535 in
n' = (d x bf)/4
= 0.816 in
X =
= 0.869
= (2 x X) / (1+((1-X)) 1
= 1.369
The tensile force is zero & the shear forces values are very small
Hence the fasteners are required only for the fixing purpose of the column.
3. CONCLUSION
Section profiles provided for the Base plate satisfies the stress ratio limits.
Fastener sizes are decided by the material availability. But less than 10mm dia. Bolts are not
advisable.