Sunteți pe pagina 1din 107

ASC INFRATECH PVT. LTD.

Client:
S.P.SINGLA CONSTRUCTIONS PVT.LTD.
Project:
Design of Ganga Bridge Between Arrah Project No.:

And Chapra P101010


Title: Document Rev.:
Design notes of Box Girder Super Structure No.:
With Revised Dimensions of Segments (60m A
Span)
DN032
This document is the property of ASC INFRATECH PVT. LTD. and must not be passed on to any person or body not authorised by us to receive it nor be
copied or otherwise made use of either in full or in part by such person or body without our prior permission in writing.

Revision Details:

A 21-03-13 Revised as per TCPL Comments PP PP AS


0 14-02-13 Design notes of Box Girder Super Structure PP PP AS
Prepared Checked Approved
Ganga Bridge Between Arrah And Chapra P101010
Design of Box Girder Super Structure With Revised Dimensions of Segments (60m Span DN032RA

INTRODUCTION

This design note pertains to the design of simply supported PSC Box Superstructure of span
57.8 m c/c of bearing for Bridge across River Ganga. The bridge is four lane with footpath on
both side. The carriageway width is 15.0m and the overall width is 20.5m

Segmental construction is proposed to be adopted for the construction of the bridge.The


segments of the single cell Prestressed concrete box girder superstructure in M45 grade
concrete are proposed to be cast in the casting yard. The box shall be post tensioned in single
stage when web and deck slab concrete is 28 days old with minimum strength of 45 MPa.

The box section is single cell with a depth of 3.4m, a deck width of 20.5m and a soffit width of
6.9m. The deck slab is kept with 2.5% camber on both sides from the median edge. The
center to centre of bearings under the box girder in transverse direction of box is 5300mm
centre to centre. Typical cross-section of box superstructure is shown in Fig. 1.

1
Ganga Bridge Between Arrah And Chapra P101010
Design of Box Girder Super Structure With Revised Dimensions of Segments (60m Span DN032RA

DESIGN BASIS AND PARAMETERS

The analysis of the box girder has been carried out on the following basis:

The bending moment and shear forces in the longitudinal direction due to DL, SIDL
and Live Loads have been worked out based on Simple Beam Theory considering
centre to centre distance between bearings as span length.

In transverse direction the box girder has been analysed as RCC section. Box has
been analysed for transverse bending using plane frame analysis of the box frame by
considering a unit width of the box with load intensities due to live load calculated by
using effective width method.

To account for moment due to distorsion and warping, the live load bending moments
and shear forces in the longitudinal directions have been increased by 5% .

The resultant fibre stresses under service condition have been checked as per
IRC112.

Differential temperature variation across the depth has been taken as per fig 10 of
IRC:6-2000 for a temperature variation of 25 degrees. The value of E is taken 100%
for temperature effect. The differential temperature variation across the depth cause
secondary moment in the transverse frame and eigen stresses in the longitudinal
direction. This case has been combined with 50% Liveload with the permissible
stresses increased by 15%. In both transverse and longitudinal direction untensioned
steel is provided as per requirement.

Ultimate resistance of the box girder in flexure has been checked as per provision of
IRC112:2011.

Shear and torsion checks have been made as per IRC 112:2011. Section cracked or
uncracked in flexure has been decided on the basis of whether the maximum
ultimate capacity in shear is governed by cracked or uncracked capacity. Where
uncracked capacity governs, the relief due to prestress force has been added to the
shear capacity of the section obtained based on IRC:112-2011.

2
Ganga Bridge Between Arrah And Chapra P101010
Design of Box Girder Super Structure With Revised Dimensions of Segments (60m Span DN032RA

DESIGN DATA

Statical Scheme Simply Supported PSC


Box Girder Span 57.8 m

Carriageway Width on each side 7.50 m


Crash Barrier width on each side 0.45 m
Width of Median 0.45 m
Footpath on both side 1.20 m
Railing on each side 0.20 m
Total Width 20.50 m
Cross Slope (Camber) on both side 2.50%
Wearing Coat Thickness (Uniform) 0.065 m
Box Superstructure depth 3.4 m
Angle of Inclination of Web with Horizontal 45.50 deg

STRUCTURAL DESIGN DATA

Concrete Grade M45


2
Modulus of Elasticity for Concrete 3.354E+04 t/m
3
Density of Concrete (PSC) 2.5 t/m
o
Coefficient of Thermal Expansion 1.17E-05 / C
Untensioned Reinforcement Bars HYSD Fe-500
Prestressing Steel 19T15 Cables
Type of Sheathing HDPE
Friction Coefficient 0.17
Wobble Coefficient 0.002
Relaxation Losses 2.50%
( for Low Relaxation Loss strands)

3
Ganga Bridge Between Arrah And Chapra P101010
Design of Box Girder Super Structure With Revised Dimensions of Segments (60m Span DN032RA

CALCULATION FOR SECTIONAL PROPERTIES

Single cell box girder with a constant depth of 3.4m has been proposed. The deck width is
20.5m with a cantilever of 3.9m.There is a footpath of 1.5m on both side of the box.Concrete
strut of size 0.40.4 m has been proposed at 3.0m interval. The soffit width is 6.9m so that the
web inclination is 45.59 degres with the vertical.

The thickness of the deck slab is kept 230 mm. throughout and soffit thicknes has been kept
400mm upto distance 10.2m from the bearing and variable(400mm to 260mm) from 10.2m to
12.2m and then 260mm throughout.

The web thickness is constant 310mm at midspan and upto a distance of 10.2m on either side
of the support. It then increases uniformly to 460mm at 12.2m from support on both the sides.

Haunches have been provided both in the soffit and the deck. The top haunch of 900mm X
193mm has been provided at mid span based on the requirements of transverse bending. The
bottom haunch of size 900mm x 150 mm is provided at mid span .

Diaphragm of thickness 800mm have been provided at either support.

4
Ganga Bridge Between Arrah And Chapra P101010
Design of Box Girder Super Structure With Revised Dimensions of Segments (60m Span DN032RA

CALCULATION OF SECTION PROPERTIES

Section at midspan Section at Web thickness 460mm Section at Web thickness 610mm Section at diaphragm Location
Node No X (m) Y(m) Node No X (m) Y(m) Node No X (m) Y(m) Node No X (m) Y(m)
1 0 0 1 0 0 1 0 0 1 0 0
2 -3.45 0 2 -3.45 0 2 -3.45 0 2 -3.45 0
3 -6.35 2.8413 3 -6.35 2.8413 3 -6.35 2.8413 3 -6.2952 2.7876
4 -8.5 2.9876 4 -8.5 2.9876 4 -8.5 2.9876 4 -10.25 2.7876
5 -10.25 2.9876 5 -10.25 2.9876 5 -10.25 2.9876 5 -10.2494 3.1876
6 -10.2494 3.1876 6 -10.2494 3.1876 6 -10.2494 3.181 6 0 3.4
7 0 3.4 7 0 3.4 7 0 3.4 7 10.2494 3.1876
8 10.2494 3.1876 8 10.2494 3.1944 8 10.2494 3.1876 8 10.25 2.7876
9 10.2494 2.9876 9 10.2494 2.9876 9 10.25 2.9876 9 6.2952 2.7876
10 8.5 2.9876 10 8.5 2.9876 10 8.5 2.9876 10 3.45 0
11 6.35 2.8413 11 6.35 2.8413 11 6.35 2.8413 11 0 0
12 3.45 0 12 3.45 0 12 3.45 0 12 0 1.26
13 0 0 13 0 0 13 0 0 13 0.45 1.26
14 0 0.26 14 0 0.4 14 0 0.4 14 0.6 1.41
15 2.525 0.26 15 2.525 0.4 15 2.254 0.4 15 0.6 2.01
16 3.425 0.41 16 3.339 0.5357 16 3.067 0.5357 16 0.45 2.16
17 5.81 2.747 17 5.634 2.7846 17 5.369 2.7913 17 -0.45 2.16
18 5.771 2.8834 18 5.595 2.921 18 5.33 2.9277 18 -0.6 2.01
19 5.017 3.0445 19 5.017 3.0445 19 4.753 3.0511 19 -0.6 1.41
20 0.837 3.149 20 0.837 3.149 20 0.837 3.149 20 -0.45 1.26
21 0.4 2.76 21 0.4 2.76 21 0.4 2.76 21 0 1.26
22 -0.4 2.76 22 -0.4 2.76 22 -0.4 2.76
23 -0.837 3.149 23 -0.837 3.149 23 -0.837 3.149
24 -5.017 3.0445 24 -5.017 3.052 24 -4.753 3.0511
25 -5.771 2.8834 25 -5.595 2.921 25 -5.33 2.9277
26 -5.81 2.747 26 -5.6349 2.7846 26 -5.3698 2.7909
27 -3.425 0.41 27 -3.339 0.5357 27 -3.067 0.5357
28 -2.525 0.26 28 -2.525 0.4 28 -2.254 0.4
29 0 0.26 29 0 0.4 29 0 0.4
30 0 0 29 0 0

2 2 2 2
Area 10.371 m Area 12.362 m Area 13.739 m Area 36.507 m
Cg 2.214 m Cg 2.028 m Cg 1.990 m Cg 1.955 m
4 4 4 4
Ixx 16.023 m Ixx 19.716 m Ixx 20.576 m Ixx 34.440 m

5
Ganga Bridge Between Arrah And Chapra P101010
Design of Box Girder Super Structure With Revised Dimensions of Segments (60m Span DN032RA

SUMMARY OF SECTION PROPERTIES

Section Moment of
Location Area Cg
No Inertia

(m) (m2) (m) (m4)


1 1.100 13.739 1.990 20.576
2 2.900 13.739 1.990 20.576
3 5.900 13.739 1.990 20.576
4 7.800 12.362 2.028 19.716
5 9.700 12.362 2.028 19.716
6 12.700 10.371 2.213 16.023
7 15.700 10.371 2.213 16.023
8 18.700 10.371 2.213 16.023
9 21.700 10.371 2.213 16.023
10 24.700 10.371 2.213 16.023
11 27.700 10.371 2.213 16.023
12 28.900 10.371 2.213 16.023
6
Ganga Bridge Between Arrah And Chapra P101010
Design of Box Girder Super Structure With Revised Dimensions of Segments (60m Span DN032RA

LOADS AND BENDING MOMENT CALCULATIONS

Following pages pertain to calculation of various loads on box superstructure due to DL, SIDL, Live Load etc.
and corresponding moments and shear. The longitudinal analysis for moments at various sections has been
done using STAAD.

DEAD LOAD ANALYSIS

Dead load on superstructure has been applied using selfweight command of STAAD. The average section
properties have been adopted for member having variable cross-section. Other loads such as weight of
diaphragm have been applied as concentrated loads. These loads are as calculated below.

Section at Midspan

Section just after diaphragm location

7
Ganga Bridge Between Arrah And Chapra P101010
Design of Box Girder Super Structure With Revised Dimensions of Segments (60m Span DN032RA

SUPERIMPOSED DEAD LOAD ANALYSIS

Weight of wearing coat @ 0.175 0.175 *7.5*2 = 2.625 t/m


Barrier Load @ 0.75 = 1.50 t/m
Railing @ 0.3 = 0.60 t/m
median 1.2*0.25*2.4 = 0.75 t/m
=
Wearing coat on footpath 1.5*2*0.175 = 0.53 t/m
Assuming load due to Concrete srut = 0.30 t/m
Total load = 6.30 t/m
Say = 6.30 t/m

SIDL eccentricity with respect to centerline of box = 0.00 tm/m

SIDL is applied as UDL over the box superstructure. The analysis has been carried out using STAAD3.

LIVE LOAD ANALYSIS

The maximum live load moment at any section has been calculated by moving Cl A and Cl 70R train over the
structure. The analysis has been done by STAAD3. The STAAD input giving Live load positions for maximum
moments at any section are presented only. The

The live load combination for maximum live load moment is one lane or two lane Cl A or one lane Cl 70R. The
longitudinal moments are increased by impact factor as per IRC:6. The longitudinal moments are also
increased by 10% to cater for distortional and warping effects.

Impact factor (as per IRC : 6-2000)

Impact factor = 8.8% for span greater than 45m

The maximum live load moments and shear at various sections are summarised on next sheets in
tabular form.

FOOTPATH LIVE LOAD ANALYSIS

Width of footpath 1.5 m


2
Basic intensity of loading (P') 0.4 t/m
Span 57.8 m
2
Intencity of loading (Span >30m) 0.22 t/m
Intencity of loading per meter 0.669 t/m
Say 0.67 t/m

The maximum moment due to footpath liveload comes when the entire span is loaded. However for maximum
shear at any section only the appropriate portion which produces the maximum shear is loaded.

8
Ganga Bridge Between Arrah And Chapra P101010
Design of Box Girder Super Structure With Revised Dimensions of Segments (60m Span DN032RA

MOMENT DUE TO DEAD LOAD AND SIDL

MOMENT
Section No Location SIDL
STG1
m tm tm
1 1.100 881.2 198.0
2 2.900 2234.0 505.5
3 5.900 4248.9 972.2
4 7.800 5376.3 1238.3
5 9.700 6392.1 1481.4
6 12.700 7780.0 1818.5
7 15.700 8923.4 2098.6
8 18.700 9833.5 2321.5
9 21.700 10510.2 2487.2
10 24.700 10953.6 2595.8
11 27.700 11163.6 2647.2
12 28.900 11182.2 2651.8

9
Ganga Bridge Between Arrah And Chapra P101010
Design of Box Girder Super Structure With Revised Dimensions of Segments (60m Span DN032RA

SHEAR DUE TO DEAD LOAD AND SIDL

Section No Location SHEAR DL SIDL

(m) t t
1 1.100 782.4 176.5
2 2.900 720.6 165.1
3 5.900 622.7 146.1
4 7.800 564.0 134.0
5 9.700 505.3 121.9
6 12.700 420.0 102.9
7 15.700 342.2 83.8
8 18.700 264.5 64.8
9 21.700 186.7 45.7
10 24.700 108.9 26.7
11 27.700 31.1 7.6
12 28.900 0.0 0.0

10
Ganga Bridge Between Arrah And Chapra P101010
Design of Box Girder Super Structure With Revised Dimensions of Segments (60m Span DN032RA

FOOTPATH LIVELOAD(FOR BOTH SIDE)

Section FPLL CORR. ECC OF CORR CORR.


Location TORSIONAL MAX SHEAR CORR. MOMENT TORSIONAL
No MOMENT SHEAR FPLL
MOMENT MOMENT
( tm ) (t) (m) ( tm ) (t) ( tm ) ( tm )

1 1.100 20.894 18.626 0.0 0.000 18.633 20.496 0.000


2 2.900 53.335 17.420 0.0 0.000 17.469 50.659 0.000
3 5.900 102.580 15.410 0.0 0.000 15.612 92.109 0.000
4 7.800 130.650 14.137 0.0 0.000 14.490 113.019 0.000
5 9.700 156.301 12.864 0.0 0.000 13.409 130.071 0.000
6 12.700 191.878 10.854 0.0 0.000 11.789 149.718 0.000
7 15.700 221.425 8.844 0.0 0.000 10.273 161.280 0.000
8 18.700 244.942 6.834 0.0 0.000 8.861 165.696 0.000
9 21.700 262.429 4.824 0.0 0.000 7.553 163.905 0.000
10 24.700 273.886 2.814 0.0 0.000 6.350 156.845 0.000
11 27.700 279.313 0.804 0.0 0.000 5.251 145.455 0.000
12 28.900 279.795 0.000 0.0 0.000 4.447 151.274 0.000

11
Ganga Bridge Between Arrah And Chapra P101010
Design of Box Girder Super Structure With Revised Dimensions of Segments (60m Span DN032RA

MOMENT DUE TO LIVELOAD

Impact factor 1.088 Enhancement for distorsion and warping 5.0%

One lane Class A with Four lane Class A with impact Two lane Class 70R with
Section
Location Impact and enhancement and enhancement for impact and enhancement for
No Total Corr.
for distorsion and warping distorsion and warping distorsion and warping
moment Shear

Moment Corr. Shear Moment Corr. Shear Moment Corr. Shear

tm t tm t tm t tm t

1 1.100 71.2 51.7 228 165.5 206.5 187.7 228 165.5


2 2.900 175.5 48.4 562 154.8 516.3 178.0 561.5 154.8
3 5.900 336.0 41.7 1075 133.4 952.7 137.2 1075.2 133.4
4 7.800 420.2 38.4 1345 122.8 1183.3 96.8 1344.7 122.8
5 9.700 494.3 34.5 1582 110.5 1382.6 115.0 1581.7 110.5
6 12.700 589.2 17.8 1885 57.0 1650.5 72.8 1885.5 57.0
7 15.700 656.0 12.9 2099 41.3 1865.4 69.4 2099.2 41.3
8 18.700 699.0 7.6 2237 24.4 2049.1 33.2 2236.7 24.4
9 21.700 740.8 2.6 2371 8.5 2196.1 49.4 2370.6 8.5
10 24.700 763.5 10.7 2443 34.1 2297.1 9.5 2443.3 34.1
11 27.700 771.5 -6.4 2469 -20.4 2341.3 0.6 2468.8 -20.4
12 28.900 769.5 -8.0 2462 -25.6 2344.3 2.0 2462.3 -25.6

12
Ganga Bridge Between Arrah And Chapra P101010
Design of Box Girder Super Structure With Revised Dimensions of Segments (60m Span DN032RA

SHEAR DUE TO LIVELOAD

Impact factor 1.088 Enhancement for distorsion and warping 5.0%

One lane Class A with Impact Four lane Class A with impact Two lane Class 70R with
Section
Location and enhancement for and enhancement for distorsion impact and enhancement for
No Total Corr.
distorsion and warping and warping distorsion and warping
Shear Moment

Shear Corr. Moment Shear Corr. Moment Shear Corr. Moment

t tm t tm t tm t tm

1 1.100 63.9 70.3 204.5 225.0 187.7 206.5 204.5 225.0


2 2.900 60.6 175.4 193.9 561.2 178.0 516.3 193.9 561.2
3 5.900 53.9 333.6 172.4 1067.5 159.0 938.1 172.4 1067.5
4 7.800 50.6 420.2 161.9 1344.6 147.3 1149.1 161.9 1344.6
5 9.700 46.8 491.9 149.8 1574.1 139.6 1354.0 149.8 1574.1
6 12.700 41.0 578.4 131.2 1850.9 126.1 1601.7 131.2 1850.9
7 15.700 36.3 645.2 116.2 2064.6 116.6 1830.9 116.6 1830.9
8 18.700 32.8 612.6 104.8 1960.3 106.5 1991.5 106.5 1991.5
9 21.700 29.2 634.6 93.6 2030.8 97.6 2118.8 97.6 2118.8
10 24.700 26.2 646.6 83.8 2069.2 87.5 2161.8 87.5 2161.8
11 27.700 22.7 628.1 72.6 2010.0 78.7 2179.1 78.7 2179.1
12 28.900 21.4 617.3 42.7 1234.7 46.8 1352.4 46.8 1352.4

13
Ganga Bridge Between Arrah And Chapra P101010
Design of Box Girder Super Structure With Revised Dimensions of Segments (60m Span DN032RA

SAGGING MOMENT DUE TO ONE LANE CLASS A FORWARD TRAIN

First Second
Section First train Second train Total Corr.
Location train Corr. Shear train Corr. Shear
No Moment location Moment Shear
location Moment

m m tm t m tm t tm t

1 1.100 1.9 49.4 45 31.0 8.6 7.8 58 52.7


2 2.900 123.1 125.2 37 152.2 18.6 6.4 143.8 43.0
3 5.900 243.1 234.4 30 272.2 37.8 6.4 272.2 36.2
4 7.800 362.5 286.1 31 391.6 55.4 7.1 341.5 37.7
5 9.700 483.7 350.4 22 512.8 55.5 5.7 405.9 28.0
6 12.700 606.1 416.5 15 635.2 72.7 5.7 489.1 21.2
7 15.700 726.1 501.0 19 755.2 56.9 3.6 557.9 22.8
8 18.700 848.2 564.8 10 877.3 43.1 2.3 607.9 12.0
9 21.700 967.3 586.2 -1 996.4 62.3 2.9 648.5 2.3
10 24.700 1089.7 630.0 8 1118.8 38.4 1.6 668.3 9.3
11 27.700 1211.8 655.1 -6 1240.9 20.2 0.7 675.3 -5.6
12 28.900 1333.6 660.6 -7 1362.7 12.9 0.4 673.6 -7.0

14
Ganga Bridge Between Arrah And Chapra P101010
Design of Box Girder Super Structure With Revised Dimensions of Segments (60m Span DN032RA

POSITIVE SHEAR DUE TO ONE LANE CLASS A FORWARD TRAIN

Section First train Second train Second train Total Corr.


Location First train Shear Corr. Moment Corr. Moment
No location location Shear Shear Moment

m m t tm m t tm t tm

1 1.100 1.9 44.9 49.4 31.0 7.8 8.6 52.7 58.0


2 2.900 123.4 43.0 124.8 152.5 6.1 17.6 49.1 142.4
3 5.900 245.8 40.3 238.0 274.9 3.9 23.3 44.3 261.3
4 7.800 367.0 38.4 299.7 396.1 3.1 23.9 41.5 323.6
5 9.700 488.5 36.5 354.1 517.6 2.1 20.5 38.6 374.7
6 12.700 610.9 33.8 429.6 640.0 1.1 14.3 35.0 443.9
7 15.700 733.0 30.8 482.9 762.1 0.4 5.5 31.1 488.5
8 18.700 855.4 28.1 525.0 - 0.0 0.4 28.1 525.4
9 21.700 946.9 0.0 0.0 977.5 25.0 542.7 25.0 542.7
10 24.700 1066.9 0.0 0.0 1099.9 22.3 551.4 22.3 551.4
11 27.700 1186.9 0.0 0.0 1222.0 19.3 533.4 19.3 533.4
12 28.900 1306.9 0.0 0.0 1343.8 18.1 523.3 18.1 523.3

15
Ganga Bridge Between Arrah And Chapra P101010
Design of Box Girder Super Structure With Revised Dimensions of Segments (60m Span DN032RA

SAGGING MOMENT DUE TO ONE LANE CLASS A REVERSE TRAIN

First Second
Section First train Second train Total Corr.
Location train Corr. Shear train Corr. Shear
No Moment location Moment Shear
location Moment

m m tm t m tm t tm t
1 1.100 12.1 48.5 32.7 41.2 13.8 12.6 62.3 45.3
2 2.900 133.6 121.6 31.3 162.7 32.0 11.0 153.6 42.4
3 5.900 255.7 246.1 28.4 284.8 48.0 8.1 294.1 36.5
4 7.800 377.2 314.9 26.8 406.3 52.9 6.8 367.8 33.6
5 9.700 498.4 380.9 24.9 527.5 51.8 5.3 432.7 30.2
6 12.700 619.9 464.9 11.6 649.0 50.9 4.0 515.8 15.6
7 15.700 742.3 536.4 8.9 771.4 37.8 2.4 574.2 11.3
8 18.700 864.4 596.0 5.8 893.5 15.8 0.8 611.8 6.7
9 21.700 986.8 634.3 3.2 1015.9 5.0 0.2 639.2 3.4
10 24.700 1108.9 658.2 0.1 - 0.0 0.0 658.2 0.1
11 27.700 1202.2 7.1 -0.2 1231.3 663.1 -2.6 670.1 -2.8
12 28.900 1323.7 14.3 -0.5 1352.8 658.5 7.3 672.7 6.8

16
Ganga Bridge Between Arrah And Chapra P101010
Design of Box Girder Super Structure With Revised Dimensions of Segments (60m Span DN032RA

POSITIVE SHEAR DUE TO ONE LANE CLASS A REVERSE TRAIN

Section First train Second train Second train Total Corr.


Location First train Shear Corr. Moment Corr. Moment
No location location Shear Shear Moment

m m t tm m t tm t tm
1 1.100 12.4 43.8 48.1 41.5 12.2 13.4 55.9 61.5
2 2.900 133.6 42.4 122.6 162.7 10.6 30.9 53.0 153.5
3 5.900 256.0 39.4 246.0 285.1 7.8 46.0 47.2 292.0
4 7.800 377.5 37.8 317.5 406.6 6.4 50.3 44.3 367.8
5 9.700 498.7 35.9 381.6 527.8 5.0 49.0 41.0 430.6
6 12.700 621.1 32.9 467.7 650.2 3.0 38.6 35.9 506.3
7 15.700 743.2 30.2 539.2 772.3 1.6 25.5 31.8 564.8
8 18.700 868.9 28.7 536.1 - 0.0 0.2 28.7 536.2
9 21.700 960.4 0.0 0.0 991.0 25.6 555.5 25.6 555.5
10 24.700 1080.4 0.0 0.0 1113.4 22.9 566.0 22.9 566.0
11 27.700 1200.4 0.0 0.0 1235.5 19.8 549.8 19.8 549.8
12 28.900 1320.4 0.0 0.0 1357.3 18.7 540.4 18.7 540.4

17
Ganga Bridge Between Arrah And Chapra P101010
Design of Box Girder Super Structure With Revised Dimensions of Segments (60m Span DN032RA

SAGGING MOMENT DUE TO ONE LANE CLASS 70R FORWARD TRAIN

First Second
Section First train Second train Total Corr.
Location train Corr. Shear train Corr. Shear
No Moment location Moment Shear
location Moment

m m tm t m tm t tm t
1 1.100 -6.5 97.6 88.7 25.9 15.4 14.0 113.0 102.7
2 2.900 105.7 249.2 85.9 138.1 33.2 11.5 282.5 97.4
3 5.900 217.9 468.6 66.2 250.3 52.6 8.9 521.2 75.1
4 7.800 330.7 596.1 46.4 363.1 51.3 6.6 647.4 53.0
5 9.700 442.9 721.0 59.3 475.3 35.4 3.7 756.4 62.9
6 12.700 555.7 881.2 38.1 588.1 21.8 1.7 903.0 39.8
7 15.700 667.3 1001.0 36.7 699.7 19.5 1.2 1020.5 38.0
8 18.700 782.5 1119.7 27.7 - 0.0 0.0 1119.7 27.7
9 21.700 893.5 1201.5 27.0 - 0.0 0.0 1201.5 27.0
10 24.700 1006.6 1256.8 5.2 - 0.0 0.0 1256.8 5.2
11 27.700 1120.0 1280.9 0.3 - 0.0 0.0 1280.9 0.3
12 28.900 1231.6 1282.5 -1.7 - 0.0 0.0 1282.5 -1.7

18
Ganga Bridge Between Arrah And Chapra P101010
Design of Box Girder Super Structure With Revised Dimensions of Segments (60m Span DN032RA

POSITIVE SHEAR DUE TO ONE LANE CLASS 70R FORWARD TRAIN

Section First train Second train Second train Total Corr.


Location First train Shear Corr. Moment Corr. Moment
No location location Shear Shear Moment

m m t tm m t tm t tm
1 1.100 -6.5 88.7 97.6 25.9 14.0 15.4 102.7 113.0
2 2.900 106.0 85.9 249.2 138.7 11.5 33.2 97.4 282.5
3 5.900 219.1 80.4 474.4 251.5 6.6 38.8 87.0 513.2
4 7.800 331.6 76.9 600.2 364.3 3.7 28.5 80.6 628.7
5 9.700 444.1 74.2 719.5 476.5 2.2 21.2 76.4 740.7
6 12.700 557.2 68.6 871.8 589.9 0.4 4.5 69.0 876.3
7 15.700 670.6 63.8 1001.7 - 0.0 0.0 63.8 1001.7
8 18.700 783.7 58.3 1089.5 - 0.0 0.0 58.3 1089.5
9 21.700 897.1 53.4 1159.2 - 0.0 0.0 53.4 1159.2
10 24.700 1010.2 47.9 1182.7 - 0.0 0.0 47.9 1182.7
11 27.700 1123.6 43.0 1192.2 - 0.0 0.0 43.0 1192.2
12 28.900 1203.4 41.0 1183.8 1236.1 0.0 0.0 41.0 1183.8

19
Ganga Bridge Between Arrah And Chapra P101010
Design of Box Girder Super Structure With Revised Dimensions of Segments (60m Span DN032RA

SAGGING MOMENT DUE TO ONE LANE CLASS 70R REVERSE TRAIN

First Second
Section First train Second train Total Corr.
Location train Corr. Shear train Corr. Shear
No Moment location Moment Shear
location Moment

m m tm t m tm t tm t
1 1.100 8.5 90.0 82 40.9 17.0 15.4 107 97.3
2 2.900 120.7 229.9 79 153.1 36.7 12.7 266.6 91.9
3 5.900 232.9 448.7 63 265.3 50.6 8.6 499.4 71.8
4 7.800 345.1 572.7 50 377.5 57.9 7.4 630.7 57.3
5 9.700 457.3 691.8 47 489.7 53.3 5.5 745.1 52.6
6 12.700 569.5 849.2 44 601.9 46.6 3.7 895.7 48.0
7 15.700 682.9 997.7 39 715.3 21.4 1.4 1019.1 40.2
8 18.700 796.0 1111.7 18 828.7 9.3 0.5 1121.0 18.1
9 21.700 909.1 1199.5 29 941.5 1.2 0.1 1200.7 29.2
10 24.700 1022.2 1255.2 7 - 0.0 0.0 1255.2 7.3
11 27.700 1135.6 1280.0 2 - 0.0 0.0 1280.0 2.4
12 28.900 1247.2 1282.5 2 - 0.0 0.0 1282.5 1.7

20
Ganga Bridge Between Arrah And Chapra P101010
Design of Box Girder Super Structure With Revised Dimensions of Segments (60m Span DN032RA

POSITIVE SHEAR DUE TO ONE LANE CLASS 70R REVERSE TRAIN

Section First train Second train Second train Total Corr.


Location First train Shear Corr. Moment Corr. Moment
No location location Shear Shear Moment

m m t tm m t tm t tm
1 1.100 8.500 81.8 90.0 41 15.4 17.0 97.3 107
2 2.900 121.000 79.3 229.9 154 12.7 36.7 91.9 266.6
3 5.900 234.100 73.9 453.5 267 7.4 43.8 81.3 497.3
4 7.800 346.600 70.4 582.8 379 4.6 35.7 75.0 618.6
5 9.700 459.100 67.6 702.6 492 2.9 28.4 70.6 730.9
6 12.700 575.200 63.2 802.5 608 0.2 2.1 63.4 804.6
7 15.700 688.600 58.3 916.0 - 0.0 0.0 58.3 916.0
8 18.700 801.700 52.8 987.5 - 0.0 0.0 52.8 987.5
9 21.700 915.100 48.0 1040.8 - 0.0 0.0 48.0 1040.8
10 24.700 1028.200 42.4 1048.0 - 0.0 0.0 42.4 1048.0
11 27.700 1141.600 37.6 1041.1 - 0.0 0.0 37.6 1041.1
12 28.900 1221.400 35.5 1026.2 1254 0.0 0.0 35.5 1026.2

21
Ganga Bridge Between Arrah And Chapra P101010
Design of Box Girder Super Structure With Revised Dimensions of Segments (60m Span DN032RA

CABLE ARRANGEMENT FRICTION & SLIP LOSS

It is proposed to use 19T15 cables conforming to class 2 of IS:14268 (low relaxation strands) with
galvanised sheathing for prestressing.

The following are the properties of the cable

Type of Cable = 19T15


2
Area of One Cable = 2660 mm
2
E (for Cable Material) = 1.95E-07 t/m
U.T.S. of 19T15 Cable = 504.9 t
Jacking Force = 0.765 U.T.S.
Sheathing Diameter = 110 mm ( ID )
Sheathing Material = HDPE
Coefficient of Friction = 0.17
Wobble Coefficient = 0.002
Slip in Cable = 6 mm
Min. Radius of Curvature = 10.40 m
Maximum Splay = 1:6

The cable arrangement is indicated in the following pages. The coordinate system adopted for the cable
arrangement is given in sheet No. P101010/B102 . When the cable are in the web the bending in the
cable is along and across the inclined plane of the web therefore a local coordinate system is adopted
for this case. The equation connecting these two coordinate system is given below

Yglobal = Ylocal * cos( ) + Zlocal * sin ( )


Zglobal = Ylocal * sin( ) - Zlocal * cos ( ) + soffit width/2
Where
= angle of inclination of web with vertical

There are a total of 25.579 cables of which 21.579 are anchored in the webs while the rest 4 are
anchored in the soffit.

The box shall be stressed in single stages after 28 days with minimum compressive stress is 45MPa.

22
Ganga Bridge Between Arrah And Chapra P101010
Design of Box Girder Super Structure With Revised Dimensions of Segments (60m Span DN032RA

Cable No Cable Type No of Strands No of Cable Jacking Force (t)


1 19T15 15 1.579 304.95
2 19T15 19 2 386.27
3 19T15 19 2 386.27
4 19T15 19 2 386.27
5 19T15 19 2 386.27
6 19T15 19 2 386.27
7 19T15 19 2 386.27
8 19T15 19 2 386.27
9 19T15 19 2 386.27
10 19T15 19 2 386.27
11 19T15 19 2 386.27
12 19T15 19 2 386.27
13 19T15 19 2 386.27
Total No of cable 25.579
Provision has been kept in cable No 1 for stressing extra strand in case of emergency

The loss in prestressing force due to friction is based on the coefficient of friction and the wobble
coefficient as given above. Slip losses have been assumed to be 6mm. The calculation for the friction
and slips losses of each cable has been made using a standard in house software.

The Cable forces after friction and slip losses at any section are added togeter to get the net
Prestressing force and the Cg of the force at any section. These are given in the following pages

In addition the vertical component of the Presterssing force and the force due to cable curvature in plan
has also been calculated.

23
Ganga Bridge Between Arrah And Chapra P101010
Design of Box Girder Super Structure With Revised Dimensions of Segments (60m Span DN032RA

CABLE PROFILE

Cable No 1
Type of Cable 19T15
No of Strands 15
STAGE 1
Symmetrical Cable only half cable taken
Distances X are from cl of bearing
X (m) Y Elevation (m) Curve type Angle/Radius X (m) Z Plan (m) Curve type Angle/Radius

-0.45 3.980 -0.45 0.305


3.986 3.980 Straight 0.000 2.9 0.305 Straight 0.000
5.76 3.901 Circular 19.958 4.3999 0.268 Circular 30.019
27.7472191 1.944 Straight -0.089 4.4001 0.267 Straight -0.050
28.9 1.893 Circular 13.005 5.9 0.230 Circular 30.056
28.900 1.893 Straight 0.000 9.775 0.230 Straight 0.000
28.900 1.893 Straight 0.000 11.024 0.193 Circular 20.852
28.900 1.893 Straight 0.000 11.026 0.192 Straight -0.060
28.9 1.893 Straight 0.000 28.9 0.155 Straight 0.000

24
Ganga Bridge Between Arrah And Chapra P101010
Design of Box Girder Super Structure With Revised Dimensions of Segments (60m Span DN032RA

CABLE PROFILE
Cable No 2
Type of Cable 19T15
No of Strands 19
STAGE 1
Symmetrical Cable only half cable taken
Distances X are from cl of bearing
X (m) Y Elevation (m) Curve type Angle/Radius X (m) Z Plan (m) Curve type Angle/Radius

-0.45 3.623 -0.45 0.305


4.027 3.623 Straight 0.000 2.9 0.305 Straight 0.000
5.7 3.553 Circular 20.027 4.3999 0.268 Circular 30.019
27.7289728 1.704 Straight -0.084 4.4001 0.267 Straight -0.050
28.9 1.655 Circular 14.001 5.9 0.230 Circular 30.056
28.900 1.655 Straight 0.000 9.775 0.230 Straight 0.000
28.900 1.655 Straight 0.000 11.024 0.193 Circular 20.852
28.900 1.655 Straight 0.000 11.026 0.192 Straight -0.060
28.9 1.655 Straight 0.000 28.9 0.155 Straight 0.000

25
Ganga Bridge Between Arrah And Chapra P101010
Design of Box Girder Super Structure With Revised Dimensions of Segments (60m Span DN032RA

CABLE PROFILE
Cable No 3
Type of Cable 19T15
No of Strands 19
STAGE 1
Symmetrical Cable only half cable taken
Distances X are from cl of bearing
X (m) Y Elevation (m) Curve type Angle/Radius X (m) Z Plan (m) Curve type Angle/Radius

-0.45 3.266 -0.45 0.305


4.062 3.266 Straight 0.000 2.9 0.305 Straight 0.000
5.635 3.204 Circular 19.985 4.3999 0.268 Circular 30.019
27.7208838 1.463 Straight -0.079 4.4001 0.267 Straight -0.050
28.9 1.417 Circular 15.010 5.9 0.230 Circular 30.056
28.900 1.417 Straight 0.000 9.775 0.230 Straight 0.000
28.900 1.417 Straight 0.000 11.024 0.193 Circular 20.852
28.900 1.417 Straight 0.000 11.026 0.192 Straight -0.060
28.9 1.417 Straight 0.000 28.9 0.155 Straight 0.000

26
Ganga Bridge Between Arrah And Chapra P101010
Design of Box Girder Super Structure With Revised Dimensions of Segments (60m Span DN032RA

CABLE PROFILE
Cable No 4
Type of Cable 19T15
No of Strands 19
STAGE 1
Symmetrical Cable only half cable taken
Distances X are from cl of bearing
X (m) Y Elevation (m) Curve type Angle/Radius X (m) Z Plan (m) Curve type Angle/Radius

-0.45 2.909 -0.45 0.305


4.13727134 2.909 Straight 0.000 2.9 0.305 Straight 0.000
5.535 2.858 Circular 19.000 4.3999 0.268 Circular 30.019
27.79653 1.216 Straight -0.074 4.4001 0.267 Straight -0.050
28.9 1.175 Circular 15.000 5.9 0.230 Circular 30.056
28.900 1.175 Straight 0.000 9.775 0.230 Straight 0.000
28.900 1.175 Straight 0.000 11.024 0.193 Circular 20.852
28.900 1.175 Straight 0.000 11.026 0.192 Straight -0.060
28.9 1.175 Straight 0.000 28.9 0.155 Straight 0.000

27
Ganga Bridge Between Arrah And Chapra P101010
Design of Box Girder Super Structure With Revised Dimensions of Segments (60m Span DN032RA

CABLE PROFILE
Cable No 5
Type of Cable 19T15
No of Strands 19
STAGE 1
Symmetrical Cable only half cable taken
Distances X are from cl of bearing
X (m) Y Elevation (m) Curve type Angle/Radius X (m) Z Plan (m) Curve type Angle/Radius

-0.45 2.539 -0.45 0.305


4.40171316 2.539 Straight 0.000 2.9 0.305 Straight 0.000
5.635 2.497 Circular 18.000 4.3999 0.268 Circular 30.019
27.872261 0.969 Straight -0.069 4.4001 0.267 Straight -0.050
28.9 0.934 Circular 15.000 5.9 0.230 Circular 30.056
28.900 0.934 Straight 0.000 9.775 0.230 Straight 0.000
28.900 0.934 Straight 0.000 11.024 0.193 Circular 20.852
28.900 0.934 Straight 0.000 11.026 0.192 Straight -0.060
28.9 0.934 Straight 0.000 28.9 0.155 Straight 0.000

28
Ganga Bridge Between Arrah And Chapra P101010
Design of Box Girder Super Structure With Revised Dimensions of Segments (60m Span DN032RA

CABLE PROFILE
Cable No 6
Type of Cable 19T15
No of Strands 19
STAGE 1
Symmetrical Cable only half cable taken
Distances X are from cl of bearing
X (m) Y Elevation (m) Curve type Angle/Radius X (m) Z Plan (m) Curve type Angle/Radius

-0.45 2.171 -0.45 0.305


4.65070964 2.171 Straight 0.000 2.9 0.305 Straight 0.000
5.74 2.136 Circular 17.000 4.3999 0.268 Circular 30.019
27.948071 0.724 Straight -0.064 4.4001 0.267 Straight -0.050
28.9 0.694 Circular 14.994 5.9 0.230 Circular 30.056
28.900 0.694 Straight 0.000 9.775 0.230 Straight 0.000
28.900 0.694 Straight 0.000 11.024 0.193 Circular 20.852
28.900 0.694 Straight 0.000 11.026 0.192 Straight -0.060
28.9 0.694 Straight 0.000 28.9 0.155 Straight 0.000

29
Ganga Bridge Between Arrah And Chapra P101010
Design of Box Girder Super Structure With Revised Dimensions of Segments (60m Span DN032RA

CABLE PROFILE
Cable No 7
Type of Cable 19T15
No of Strands 19
STAGE 1
Symmetrical Cable only half cable taken
Distances X are from cl of bearing
X (m) Y Elevation (m) Curve type Angle/Radius X (m) Z Plan (m) Curve type Angle/Radius

-0.45 1.807 -0.45 0.305


4.82714819 1.807 Straight 0.000 2.9 0.305 Straight 0.000
5.82 1.778 Circular 17.000 4.3999 0.268 Circular 30.019
28.0239543 0.479 Straight -0.059 4.4001 0.267 Straight -0.050
28.9 0.453 Circular 15.000 5.9 0.230 Circular 30.056
28.900 0.453 Straight 0.000 9.775 0.230 Straight 0.000
28.900 0.453 Straight 0.000 11.024 0.193 Circular 20.852
28.900 0.453 Straight 0.000 11.026 0.192 Straight -0.060
28.9 0.453 Straight 0.000 28.9 0.155 Straight 0.000

30
Ganga Bridge Between Arrah And Chapra P101010
Design of Box Girder Super Structure With Revised Dimensions of Segments (60m Span DN032RA

CABLE PROFILE
Cable No 8
Type of Cable 19T15
No of Strands 19
STAGE 1
Symmetrical Cable only half cable taken
Distances X are from cl of bearing
X (m) Y Elevation (m) Curve type Angle/Radius X (m) Z Plan (m) Curve type Angle/Radius

-0.45 1.445 -0.45 0.305


4.99 1.445 Straight 0.000 2.9 0.305 Straight 0.000
5.90 1.421 Circular 17.000 4.3999 0.268 Circular 30.019
28.10 0.235 Straight -0.053 4.4001 0.267 Straight -0.050
28.90 0.213 Circular 15.000 5.9 0.230 Circular 30.056
28.90 0.213 Straight 0.000 9.775 0.230 Straight 0.000
28.90 0.213 Straight 0.000 11.024 0.193 Circular 20.852
28.90 0.213 Straight 0.000 11.026 0.192 Straight -0.060
28.90 0.213 Straight 0.000 28.9 0.155 Straight 0.000

31
Ganga Bridge Between Arrah And Chapra P101010
Design of Box Girder Super Structure With Revised Dimensions of Segments (60m Span DN032RA

CABLE PROFILE
Cable No 9
Type of Cable 19T15
No of Strands 19
STAGE 1
Symmetrical Cable only half cable taken
Distances X are from cl of bearing
X (m) Y Elevation (m) Curve type Angle/Radius X (m) Z Plan (m) Curve type Angle/Radius

-0.45 1.086 -0.45 0.305


5.04 1.086 Straight 0.000 2.9 0.305 Straight 0.000
5.90 1.065 Circular 17.000 4.3999 0.268 Circular 30.019
25.20 0.091 Straight -0.050 4.4001 0.267 Straight -0.050
27.70 0.130 Circular 49.644 5.9 0.230 Circular 30.056
28.90 0.130 Straight 0.000 9.775 0.230 Straight 0.000
28.90 0.130 Straight 0.000 11.024 0.193 Circular 20.852
28.90 0.130 Straight 0.000 11.026 0.192 Straight -0.060
28.90 0.130 Straight 0.000 28.9 0.155 Straight 0.000

32
Ganga Bridge Between Arrah And Chapra P101010
Design of Box Girder Super Structure With Revised Dimensions of Segments (60m Span DN032RA

CABLE PROFILE
Cable No 10
Type of Cable 19T15
No of Strands 19
STAGE 1
Symmetrical Cable only half cable taken
Distances X are from cl of bearing
X (m) Y Elevation (m) Curve type Angle/Radius X (m) Z Plan (m) Curve type Angle/Radius
-0.45 0.723 -0.45 0.305
4.92 0.723 Straight 0.000 2.9 0.305 Straight 0.000
5.90 0.694 Circular 17.000 4.3999 0.268 Circular 30.019
16.20 0.100 Straight -0.058 4.4001 0.267 Straight -0.050
18.70 0.130 Circular 43.442 5.9 0.230 Circular 30.056
28.90 0.130 Straight 0.000 9.775 0.230 Straight 0.000
28.90 0.130 Straight 0.000 11.024 0.193 Circular 20.852
28.90 0.130 Straight 0.000 11.026 0.192 Straight -0.060
28.90 0.130 Straight 0.000 12.275 0.155 Circular 20.889
28.9 0.130 Straight 0.000 18.700 3.361 Straight 0.000
28.9 0.130 Straight 0.000 21.700 3.213 Circular 30.479
28.9 0.130 Straight 0.000 23.200 3.139 Straight -0.049
28.9 0.130 Straight 0.000 28.9 2.991 Straight 0.000
* Y and Z are along global axis from X = 18.7 to X = 28.9

33
Ganga Bridge Between Arrah And Chapra P101010
Design of Box Girder Super Structure With Revised Dimensions of Segments (60m Span DN032RA

CABLE PROFILE
Cable No 11
Type of Cable 19T15
No of Strands 19
STAGE 1
Symmetrical Cable only half cable taken
Distances X are from cl of bearing
X (m) Y Elevation (m) Curve type Angle/Radius X (m) Z Plan (m) Curve type Angle/Radius
-0.45 0.362 -0.45 0.305
4.90 0.362 Straight 0.000 2.9 0.305 Straight 0.000
5.90 0.332 Circular 17.000 4.3999 0.268 Circular 30.019
9.80 0.102 Straight -0.059 4.4001 0.267 Straight -0.050
12.30 0.130 Circular 42.418 5.9 0.230 Circular 30.056
28.90 0.130 Straight 0.000 6.875 0.230 Straight 0.000
28.90 0.130 Straight 0.000 8.124 0.193 Circular 20.852
28.90 0.130 Straight 0.000 8.126 0.192 Straight -0.060
28.90 0.130 Straight 0.000 9.375 0.155 Circular 20.889
28.9 0.130 Straight 0.000 12.300 3.361 Straight 0.000
28.9 0.130 Straight 0.000 15.000 3.153 Circular 17.618
28.9 0.130 Straight 0.000 16.500 3.014 Straight -0.093
28.9 0.130 Straight 0.000 28.9 2.806 Straight 0.000
* Y and Z are along global axis from X = 12.3 to X = 28.9

34
Ganga Bridge Between Arrah And Chapra P101010
Design of Box Girder Super Structure With Revised Dimensions of Segments (60m Span DN032RA

CABLE PROFILE
Cable No 12
Type of Cable 19T15
No of Strands 19
STAGE 1
Symmetrical Cable only half cable taken
Distances X are from cl of bearing
X (m) Y Elevation (m) Curve type Angle/Radius X (m) Z Plan (m) Curve type Angle/Radius
-0.45 0.230 -0.45 1.530
3.69940064 0.230 Straight 0.000 28.9 1.530 Straight 0.000
5.9 0.223 Straight -0.003 28.9 1.530 Straight 0.000
9.6 0.153 Straight -0.019 28.9 1.530 Straight 0.000
12.1 0.130 Circular 133.100 28.9 1.530 Straight 0.000
28.9 0.130 Straight 0.000 28.9 1.530 Straight 0.000
* Y and Z are along global axis from X = -0.45 to X = 28.9

35
Ganga Bridge Between Arrah And Chapra P101010
Design of Box Girder Super Structure With Revised Dimensions of Segments (60m Span DN032RA

CABLE PROFILE
Cable No 13
Type of Cable 19T15
No of Strands 19
STAGE 1
Symmetrical Cable only half cable taken
Distances X are from cl of bearing
X (m) Y Elevation (m) Curve type Angle/Radius X (m) Z Plan (m) Curve type Angle/Radius
-0.45 0.230 -0.45 1.170
3.69940064 0.230 Straight 0.000 28.9 1.170 Straight 0.000
5.9 0.222 Straight -0.004 28.9 1.170 Straight 0.000
9.6 0.153 Straight -0.019 28.9 1.170 Straight 0.000
12.1 0.130 Circular 134.546 28.9 1.170 Straight 0.000
28.9 0.130 Straight 0.000 28.9 1.170 Straight 0.000
* Y and Z are along global axis from X = -0.35 to X = 28.9

36
Ganga Bridge Between Arrah And Chapra P101010
Design of Box Girder Super Structure With Revised Dimensions of Segments (60m Span DN032RA

Cable No 2
Type of Cable 19T15
No of Strands 19
Jacking Force 386.3 t
Symmetrical Cable only half cable taken
Distances X are from anchorage point
X (m) Y (m) Z (m) Slope y Slope z Deviation Length (m) Pfriction (t) Pslip (t) (P/R)z (t/m)
-0.45 3.623 0.305 0.000 0.000 386.3 336.9 0.0
2.90 3.623 0.305 0.000 0.000 0.000 3.350 383.7 339.4 -8.0
4.027 3.623 0.284 0.000 -0.038 0.038 1.127 380.4 342.7 12.3
4.40 3.620 0.268 -0.019 -0.050 0.031 0.373 378.1 345.0 12.3
4.40 3.620 0.267 -0.019 -0.050 0.000 0.000 378.1 345.0 12.5
5.70 3.553 0.231 -0.084 -0.007 0.109 1.302 370.2 352.9 8.2
5.90 3.536 0.230 -0.084 0.000 0.007 0.201 369.6 353.5 0.0
9.78 3.211 0.230 -0.084 0.000 0.000 3.889 366.8 356.3 -12.0
11.02 3.106 0.193 -0.084 -0.060 0.060 1.254 362.2 361.0 0.0
11.026 3.106 0.192 -0.084 -0.060 0.000 0.002 362.2 361.0 12.1
12.275 3.001 0.155 -0.084 0.000 0.060 1.254 357.6 357.6 0.0
27.72897 1.704 0.155 -0.084 0.000 0.000 15.508 346.7 346.7 -17.6
28.9 1.655 0.155 0.000 0.000 0.084 1.172 341.0 341.0 0.0
29.432
Emergence Angle 0.000 degrees
Length of Cable 58.865 m
Cut Length 60.865 m
Null point 29.432 m
Pmin 341.0 t

Pslipleft 361.6 t Xslipleft 11.187 m


Pslipright 361.6 t Xslipright 46.613 m

Extension 209 mm

37
Ganga Bridge Between Arrah And Chapra P101010
Design of Box Girder Super Structure With Revised Dimensions of Segments (60m Span DN032RA

Cable No 3
Type of Cable 19T15
No of Strands 19
Jacking Force 386.3 t
Symmetrical Cable only half cable taken
Distances X are from anchorage point
X (m) Y (m) Z (m) Slope y Slope z Deviation Length (m) Pfriction (t) Pslip (t) (P/R)z (t/m)
-0.45 3.266 0.305 0.000 0.000 386.3 337.2 0.0
2.90 3.266 0.305 0.000 0.000 0.000 3.350 383.7 339.8 -8.0
4.062 3.266 0.283 0.000 -0.039 0.039 1.162 380.3 343.2 12.3
4.40 3.263 0.268 -0.017 -0.050 0.028 0.338 378.2 345.3 12.3
4.40 3.263 0.267 -0.017 -0.050 0.000 0.000 378.2 345.3 12.5
5.64 3.204 0.231 -0.079 -0.009 0.103 1.237 370.7 352.7 8.2
5.90 3.183 0.230 -0.079 0.000 0.009 0.266 370.0 353.5 0.0
9.78 2.878 0.230 -0.079 0.000 0.000 3.887 367.1 356.4 -12.0
11.02 2.779 0.193 -0.079 -0.060 0.060 1.253 362.5 361.0 0.0
11.026 2.779 0.192 -0.079 -0.060 0.000 0.002 362.5 361.0 12.1
12.275 2.681 0.155 -0.079 0.000 0.060 1.253 357.9 357.9 0.0
27.72088 1.463 0.155 -0.079 0.000 0.000 15.494 347.0 347.0 -16.4
28.9 1.417 0.155 0.000 0.000 0.079 1.180 341.6 341.6 0.0
29.423
Emergence Angle 0.000 degrees
Length of Cable 58.846 m
Cut Length 60.846 m
Null point 29.423 m
Pmin 341.6 t

Pslipleft 361.7 t Xslipleft 11.228 m


Pslipright 361.7 t Xslipright 46.572 m

Extension 209 mm

38
Ganga Bridge Between Arrah And Chapra P101010
Design of Box Girder Super Structure With Revised Dimensions of Segments (60m Span DN032RA

Cable No 4
Type of Cable 19T15
No of Strands 19
Jacking Force 386.3 t
Symmetrical Cable only half cable taken
Distances X are from anchorage point
X (m) Y (m) Z (m) Slope y Slope z Deviation Length (m) Pfriction (t) Pslip (t) (P/R)z (t/m)
-0.45 2.909 0.305 0.000 0.000 386.3 337.5 0.0
2.90 2.909 0.305 0.000 0.000 0.000 3.350 383.7 340.1 -8.0
4.137 2.909 0.279 0.000 -0.041 0.041 1.238 380.1 343.7 13.0
4.40 2.908 0.268 -0.014 -0.050 0.023 0.263 378.4 345.4 13.0
4.40 2.908 0.267 -0.014 -0.050 0.000 0.000 378.4 345.4 13.2
5.54 2.858 0.232 -0.074 -0.012 0.098 1.137 371.3 352.5 8.2
5.90 2.831 0.230 -0.074 0.000 0.012 0.366 370.3 353.5 0.0
9.78 2.545 0.230 -0.074 0.000 0.000 3.886 367.4 356.4 -12.0
11.02 2.453 0.193 -0.074 -0.060 0.060 1.253 362.8 361.0 0.0
11.026 2.453 0.192 -0.074 -0.060 0.000 0.002 362.8 361.0 12.1
12.275 2.361 0.155 -0.074 0.000 0.060 1.253 358.2 358.2 0.0
27.79653 1.216 0.155 -0.074 0.000 0.000 15.564 347.2 347.2 -16.5
28.9 1.175 0.155 0.000 0.000 0.074 1.104 342.1 342.1 0.0
29.415
Emergence Angle 0.000 degrees
Length of Cable 58.829 m
Cut Length 60.829 m
Null point 29.415 m
Pmin 342.1 t

Pslipleft 361.9 t Xslipleft 11.267 m


Pslipright 361.9 t Xslipright 46.533 m

Extension 210 mm

39
Ganga Bridge Between Arrah And Chapra P101010
Design of Box Girder Super Structure With Revised Dimensions of Segments (60m Span DN032RA

Cable No 5
Type of Cable 19T15
No of Strands 19
Jacking Force 386.3 t
Symmetrical Cable only half cable taken
Distances X are from anchorage point
X (m) Y (m) Z (m) Slope y Slope z Deviation Length (m) Pfriction (t) Pslip (t) (P/R)z (t/m)
-0.45 2.539 0.305 0.000 0.000 386.3 338.0 0.0
2.90 2.539 0.305 0.000 0.000 0.000 3.350 383.7 340.6 -8.0
4.400 2.539 0.268 0.000 -0.050 0.050 1.500 379.3 345.0 0.0
4.40 2.539 0.267 0.000 -0.050 0.000 0.000 379.3 345.0 8.1
4.40 2.539 0.267 0.000 -0.050 0.000 0.002 379.3 345.0 13.9
5.64 2.497 0.231 -0.069 -0.009 0.110 1.235 371.4 352.9 8.2
5.90 2.478 0.230 -0.069 0.000 0.009 0.266 370.6 353.7 0.0
9.78 2.212 0.230 -0.069 0.000 0.000 3.884 367.7 356.5 -12.1
11.02 2.127 0.193 -0.069 -0.060 0.060 1.253 363.1 361.2 0.0
11.026 2.126 0.192 -0.069 -0.060 0.000 0.002 363.1 361.2 12.1
12.275 2.041 0.155 -0.069 0.000 0.060 1.253 358.5 358.5 0.0
27.87226 0.969 0.155 -0.069 0.000 0.000 15.634 347.5 347.5 -16.5
28.9 0.934 0.155 0.000 0.000 0.069 1.028 342.7 342.7 0.0
29.406
Emergence Angle 0.000 degrees
Length of Cable 58.812 m
Cut Length 60.812 m
Null point 29.406 m
Pmin 342.7 t

Pslipleft 362.1 t Xslipleft 11.286 m


Pslipright 362.1 t Xslipright 46.514 m

Extension 210 mm

40
Ganga Bridge Between Arrah And Chapra P101010
Design of Box Girder Super Structure With Revised Dimensions of Segments (60m Span DN032RA

Cable No 6
Type of Cable 19T15
No of Strands 19
Jacking Force 386.3 t
Symmetrical Cable only half cable taken
Distances X are from anchorage point
X (m) Y (m) Z (m) Slope y Slope z Deviation Length (m) Pfriction (t) Pslip (t) (P/R)z (t/m)
-0.45 2.171 0.305 0.000 0.000 386.3 338.5 0.0
2.90 2.171 0.305 0.000 0.000 0.000 3.350 383.7 341.1 -8.0
4.400 2.171 0.268 0.000 -0.050 0.050 1.500 379.3 345.5 0.0
4.40 2.171 0.267 0.000 -0.050 0.000 0.000 379.3 345.5 8.1
4.65 2.171 0.256 0.000 -0.042 0.008 0.251 378.6 346.2 14.6
5.74 2.136 0.230 -0.064 -0.005 0.100 1.090 371.4 353.4 8.3
5.90 2.126 0.230 -0.064 0.000 0.005 0.160 370.9 353.8 0.0
9.78 1.880 0.230 -0.064 0.000 0.000 3.883 368.1 356.7 -12.1
11.02 1.800 0.193 -0.064 -0.060 0.060 1.252 363.4 361.3 0.0
11.026 1.800 0.192 -0.064 -0.060 0.000 0.002 363.4 361.3 12.1
12.275 1.721 0.155 -0.064 0.000 0.060 1.252 358.8 358.8 0.0
27.94807 0.724 0.155 -0.064 0.000 0.000 15.705 347.7 347.7 -16.5
28.9 0.694 0.155 0.000 0.000 0.064 0.952 343.3 343.3 0.0
29.398
Emergence Angle 0.000 degrees
Length of Cable 58.796 m
Cut Length 60.796 m
Null point 29.398 m
Pmin 343.3 t

Pslipleft 362.4 t Xslipleft 11.309 m


Pslipright 362.4 t Xslipright 46.491 m

Extension 210 mm

41
Ganga Bridge Between Arrah And Chapra P101010
Design of Box Girder Super Structure With Revised Dimensions of Segments (60m Span DN032RA

Cable No 7
Type of Cable 19T15
No of Strands 19
Jacking Force 386.3 t
Symmetrical Cable only half cable taken
Distances X are from anchorage point
X (m) Y (m) Z (m) Slope y Slope z Deviation Length (m) Pfriction (t) Pslip (t) (P/R)z (t/m)
-0.45 1.807 0.305 0.000 0.000 386.3 338.9 0.0
2.90 1.807 0.305 0.000 0.000 0.000 3.350 383.7 341.5 -8.0
4.400 1.807 0.268 0.000 -0.050 0.050 1.500 379.3 345.9 0.0
4.40 1.807 0.267 0.000 -0.050 0.000 0.000 379.3 345.9 8.1
4.83 1.807 0.249 0.000 -0.036 0.014 0.427 378.1 347.1 14.7
5.82 1.778 0.230 -0.059 -0.003 0.092 0.993 371.5 353.7 8.3
5.90 1.773 0.230 -0.059 0.000 0.003 0.080 371.3 353.9 0.0
9.78 1.546 0.230 -0.059 0.000 0.000 3.882 368.4 356.8 -12.1
11.02 1.473 0.193 -0.059 -0.060 0.060 1.252 363.7 361.4 0.0
11.026 1.473 0.192 -0.059 -0.060 0.000 0.002 363.7 361.4 12.1
12.275 1.400 0.155 -0.059 0.000 0.060 1.252 359.1 359.1 0.0
28.02395 0.479 0.155 -0.059 0.000 0.000 15.776 348.0 348.0 -16.5
28.9 0.453 0.155 0.000 0.000 0.059 0.876 343.9 343.9 0.0
29.391
Emergence Angle 0.000 degrees
Length of Cable 58.782 m
Cut Length 60.782 m
Null point 29.391 m
Pmin 343.9 t

Pslipleft 362.6 t Xslipleft 11.338 m


Pslipright 362.6 t Xslipright 46.462 m

Extension 210 mm

42
Ganga Bridge Between Arrah And Chapra P101010
Design of Box Girder Super Structure With Revised Dimensions of Segments (60m Span DN032RA

Cable No 8
Type of Cable 19T15
No of Strands 19
Jacking Force 386.3 t
Symmetrical Cable only half cable taken
Distances X are from anchorage point
X (m) Y (m) Z (m) Slope y Slope z Deviation Length (m) Pfriction (t) Pslip (t) (P/R)z (t/m)
-0.45 1.445 0.305 0.000 0.000 386.3 339.3 0.0
2.90 1.445 0.305 0.000 0.000 0.000 3.350 383.7 341.9 -8.0
4.400 1.445 0.268 0.000 -0.050 0.050 1.500 379.3 346.3 0.0
4.40 1.445 0.267 0.000 -0.050 0.000 0.000 379.3 346.3 8.1
4.99 1.445 0.244 0.000 -0.030 0.020 0.594 377.6 348.0 14.8
5.90 1.421 0.230 -0.053 0.000 0.084 0.907 371.6 354.0 0.0
9.78 1.214 0.230 -0.053 0.000 0.000 3.881 368.7 356.9 -12.1
11.02 1.147 0.193 -0.053 -0.060 0.060 1.251 364.0 361.5 0.0
11.03 1.147 0.192 -0.053 -0.060 0.000 0.002 364.0 361.5 12.1
12.275 1.080 0.155 -0.053 0.000 0.060 1.251 359.5 359.5 0.0
28.09991 0.235 0.155 -0.053 0.000 0.000 15.847 348.2 348.2 -16.5
28.9 0.213 0.155 0.000 0.000 0.053 0.800 344.5 344.5 0.0
29.384
Emergence Angle 0.000 degrees
Length of Cable 58.769 m
Cut Length 60.769 m
Null point 29.384 m
Pmin 344.5 t

Pslipleft 362.8 t Xslipleft 11.369 m


Pslipright 362.8 t Xslipright 46.431 m

Extension 210 mm

43
Ganga Bridge Between Arrah And Chapra P101010
Design of Box Girder Super Structure With Revised Dimensions of Segments (60m Span DN032RA

Cable No 9
Type of Cable 19T15
No of Strands 19
Jacking Force 386.3 t
Symmetrical Cable only half cable taken
Distances X are from anchorage point
X (m) Y (m) Z (m) Slope y Slope z Deviation Length (m) Pfriction (t) Pslip (t) (P/R)z (t/m)
-0.45 1.086 0.305 0.000 0.000 386.3 339.5 0.0
2.90 1.086 0.305 0.000 0.000 0.000 3.350 383.7 342.1 -8.0
4.400 1.086 0.268 0.000 -0.050 0.050 1.500 379.3 346.5 0.0
4.40 1.086 0.267 0.000 -0.050 0.000 0.000 379.3 346.5 8.1
5.04 1.086 0.242 0.000 -0.029 0.021 0.644 377.4 348.3 14.8
5.90 1.065 0.230 -0.050 0.000 0.079 0.857 371.8 354.0 0.0
9.78 0.869 0.230 -0.050 0.000 0.000 3.880 368.9 356.9 -12.1
11.02 0.806 0.193 -0.050 -0.060 0.060 1.251 364.2 361.5 0.0
11.03 0.806 0.192 -0.050 -0.060 0.000 0.002 364.2 361.5 12.1
12.275 0.743 0.155 -0.050 0.000 0.060 1.251 359.6 359.6 0.0
25.2 0.091 0.155 -0.050 0.000 0.000 12.941 350.4 350.4 -5.0
27.7 0.130 0.155 0.000 0.000 0.050 2.501 345.7 345.7 0.0
28.9 0.130 0.155 0.000 0.000 0.000 1.200 344.9 344.9 0.0
29.378
Emergence Angle 0.000 degrees
Length of Cable 58.756 m
Cut Length 60.756 m
Null point 29.378 m
Pmin 344.9 t

Pslipleft 362.9 t Xslipleft 11.392 m


Pslipright 362.9 t Xslipright 46.408 m

Extension 210 mm

44
Ganga Bridge Between Arrah And Chapra P101010
Design of Box Girder Super Structure With Revised Dimensions of Segments (60m Span DN032RA

Cable No 10
Type of Cable 19T15
No of Strands 19
Jacking Force 386.3 t
Symmetrical Cable only half cable taken
Distances X are from anchorage point
X (m) Y (m) Z (m) Slope y Slope z Deviation Length (m) Pfriction (t) Pslip (t) (P/R)z (t/m)
-0.45 0.723 0.305 0.000 0.000 386.3 339.0 0.0
2.90 0.723 0.305 0.000 0.000 0.000 3.350 383.7 341.6 -8.0
4.400 0.723 0.268 0.000 -0.050 0.050 1.500 379.3 346.0 0.0
4.40 0.723 0.267 0.000 -0.050 0.000 0.000 379.3 346.0 8.1
4.92 0.723 0.246 0.000 -0.033 0.017 0.521 377.8 347.5 14.8
5.90 0.694 0.230 -0.058 0.000 0.090 0.980 371.3 354.0 0.0
9.78 0.471 0.230 -0.058 0.000 0.000 3.881 368.4 356.8 -12.1
11.02 0.399 0.193 -0.058 -0.060 0.060 1.252 363.8 361.5 0.0
11.03 0.399 0.192 -0.058 -0.060 0.000 0.002 363.8 361.5 12.1
12.275 0.327 0.155 -0.058 0.000 0.060 1.252 359.2 359.2 0.0
16.2 0.100 0.155 -0.058 0.000 0.000 3.932 356.4 356.4 -4.4
18.7 0.130 3.361 0.000 0.000 0.058 2.501 351.1 351.1 4.8
21.7 0.130 3.213 0.000 -0.049 0.049 3.001 346.1 346.1 0.0
23.2 0.130 3.139 0.000 -0.049 0.000 1.502 345.1 345.1 -11.2
24.7 0.130 2.991 0.000 0.000 0.049 1.500 341.2 341.2 0.0
28.9 0.130 2.991 0.000 0.000 0.000 4.200 338.3 338.3 0.0
29.374
Emergence Angle 0.000 degrees
Length of Cable 58.748 m
Cut Length 60.748 m
Null point 29.374 m
Pmin 338.3 t

Pslipleft 362.6 t Xslipleft 11.337 m


Pslipright 362.6 t Xslipright 46.463 m

Extension 208 mm

45
Ganga Bridge Between Arrah And Chapra P101010
Design of Box Girder Super Structure With Revised Dimensions of Segments (60m Span DN032RA

Cable No 11
Type of Cable 19T15
No of Strands 19
Jacking Force 386.3 t
Symmetrical Cable only half cable taken
Distances X are from anchorage point
X (m) Y (m) Z (m) Slope y Slope z Deviation Length (m) Pfriction (t) Pslip (t) (P/R)z (t/m)
-0.45 0.362 0.305 0.000 0.000 386.3 335.6 0.0
2.90 0.362 0.305 0.000 0.000 0.000 3.350 383.7 338.2 -7.9
4.400 0.362 0.268 0.000 -0.050 0.050 1.500 379.3 342.6 0.0
4.40 0.362 0.267 0.000 -0.050 0.000 0.000 379.3 342.6 8.0
4.90 0.362 0.247 0.000 -0.033 0.017 0.498 377.9 344.0 14.6
5.90 0.332 0.230 -0.059 0.000 0.093 1.003 371.2 350.7 0.0
6.88 0.275 0.230 -0.059 0.000 0.000 0.977 370.5 351.4 -11.9
8.12 0.201 0.193 -0.059 -0.060 0.060 1.252 365.8 356.1 0.0
8.13 0.201 0.192 -0.059 -0.060 0.000 0.002 365.8 356.1 12.0
9.375 0.127 0.155 -0.059 0.000 0.060 1.252 361.2 360.7 0.0
9.8 0.102 0.155 -0.059 0.000 0.000 0.426 360.9 360.9 -4.5
12.3 0.130 3.361 0.000 0.000 0.059 2.501 355.5 355.5 9.7
15 0.130 3.153 0.000 -0.093 0.093 2.703 348.1 348.1 0.0
16.5 0.130 3.014 0.000 -0.093 0.000 1.506 347.0 347.0 -21.0
18 0.130 2.806 0.000 0.000 0.093 1.502 340.6 340.6 0.0
28.9 0.130 2.806 0.000 0.000 0.000 10.900 333.2 333.2 0.0
29.371
Emergence Angle 0.000 degrees
Length of Cable 58.743 m
Cut Length 60.743 m
Null point 29.371 m
Pmin 333.2 t

Pslipleft 360.9 t Xslipleft 9.724 m


Pslipright 360.9 t Xslipright 48.076 m

Extension 205 mm

46
Ganga Bridge Between Arrah And Chapra P101010
Design of Box Girder Super Structure With Revised Dimensions of Segments (60m Span DN032RA

Cable No 12
Type of Cable 19T15
No of Strands 19
Jacking Force 386.3 t
Symmetrical Cable only half cable taken
Distances X are from anchorage point
X (m) Y (m) Z (m) Slope y Slope z Deviation Length (m) Pfriction (t) Pslip (t) (P/R)z (t/m)
-0.45 0.230 1.530 0.000 0.000 386.3 352.7 0.0
3.70 0.230 1.530 0.000 0.000 0.000 4.149 383.1 355.9 0.0
5.900 0.223 1.530 -0.019 0.000 0.019 2.201 380.2 358.8 0.0
9.60 0.153 1.530 -0.019 0.000 0.000 3.701 377.4 361.6 0.0
12.10 0.130 1.530 0.000 0.000 0.019 2.500 374.3 364.7 0.0
28.90 0.130 1.530 0.000 0.000 0.000 16.800 361.9 361.9 0.0
29.351
Emergence Angle 0.000 degrees
Length of Cable 58.702 m
Cut Length 60.702 m
Null point 29.351 m
Pmin 361.9 t

Pslipleft 369.5 t Xslipleft 18.572 m


Pslipright 369.5 t Xslipright 39.228 m

Extension 216 mm

47
Ganga Bridge Between Arrah And Chapra P101010
Design of Box Girder Super Structure With Revised Dimensions of Segments (60m Span DN032RA

Cable No 13
Type of Cable 19T15
No of Strands 19
Jacking Force 386.3 t
Symmetrical Cable only half cable taken
Distances X are from anchorage point
X (m) Y (m) Z (m) Slope y Slope z Deviation Length (m) Pfriction (t) Pslip (t) (P/R)z (t/m)
-0.45 0.230 1.170 0.000 0.000 386.3 353.3 0.0
3.70 0.230 1.170 0.000 0.000 0.000 4.149 383.1 356.5 0.0
5.900 0.222 1.170 -0.015 0.000 0.015 2.201 380.4 359.1 0.0
9.60 0.167 1.170 -0.015 0.000 0.000 3.700 377.6 361.9 0.0
12.10 0.130 1.170 0.000 0.000 0.015 2.500 374.8 364.7 0.0
28.90 0.130 1.170 0.000 0.000 0.000 16.800 362.4 362.4 0.0
29.351
Emergence Angle 0.000 degrees
Length of Cable 58.701 m
Cut Length 60.701 m
Null point 29.351 m
Pmin 362.4 t

Pslipleft 369.8 t Xslipleft 18.857 m


Pslipright 369.8 t Xslipright 38.943 m

Extension 216 mm

48
Ganga Bridge Between Arrah And Chapra P101010
Design of Box Girder Super Structure With Revised Dimensions of Segments (60m Span DN032RA

SUMMARRY OF CABLE FORCES AFTER FRICTION AND SLIP LOSSES


AT SECTIONS

Distance Stage1
Section from end No of Ecc from
Hor Force Ver force
No Support Cables bottom
(m) (m) (t) (t)
1 1 1.100 25.579 1.473 8734.703
2 3 2.900 25.579 1.473 8770.099
3 6 5.900 25.579 1.402 9048.165
4 8 7.800 25.579 1.321 9086.335
5 10 9.700 25.579 1.237 9132.404
6 13 12.700 25.579 1.080 9166.835
7 16 15.700 25.579 0.971 9118.512
8 19 18.700 25.579 0.867 9067.581
9 22 21.700 25.579 0.770 8998.741
10 25 24.700 25.579 0.673 8923.936
11 28 27.700 25.579 0.576 8889.472
12 29 28.900 25.579 0.577 8848.505

49
Ganga Bridge Between Arrah And Chapra P101010
Design of Box Girder Super Structure With Revised Dimensions of Segments (60m Span DN032RA

EFFECT OF TEMPERATURE GRADIENT

There are no stresses developed in structure due to uniform rise/fall in temperature as the structure is
free to expand/contract. However due to temperature gradient along depth of box (rise and fall case),
eigen stresses are developed.

The temperature gradient along depth (rise/fall) have been considered as per fig 10 of IRC:6-2010 as
shown below.

Temperature Gradient

o o
17.80 C 10.6 C
150

250
o o
4 C 0.7 C
250

200
3.4

200
o
0.8 C
150

250
o o
2.1 C 6.6 C
(Temp. Rise) (Temp. Fall)

The eigen stresses have been calculated for each section along with the force and eccentricity based on
full value of E value.

The resultant temperature stresses have been combined later with stresses due to other effects like DL,
SIDL etc in tabular manner. Only 50% live load has been considered for load combination with
temperature gradient. In case there tension in the box in this load combination then untensioned steel has
been provided as per requirement.

50
Ganga Bridge Between Arrah And Chapra P101010
Design of Box Girder Super Structure With Revised Dimensions of Segments (60m Span DN032RA

CABLE ARRANGEMENT FRICTION & SLIP LOSS

It is proposed to use 19T15 cables conforming to class 2 of IS:14268 (low relaxation strands) with
galvanised sheathing for prestressing.

The following are the properties of the cable

Type of Cable = 19T15


2
Area of One Cable = 2660 mm
2
E (for Cable Material) = 1.95E-07 t/m
U.T.S. of 19T15 Cable = 504.9 t
Jacking Force = 0.765 U.T.S.
Sheathing Diameter = 110 mm ( ID )
Sheathing Material = HDPE
Coefficient of Friction = 0.17
Wobble Coefficient = 0.002
Slip in Cable = 6 mm
Min. Radius of Curvature = 10.40 m
Maximum Splay = 1:6

The cable arrangement is indicated in the following pages. The coordinate system adopted for the cable
arrangement is given in sheet No. P101010/B102 . When the cable are in the web the bending in the
cable is along and across the inclined plane of the web therefore a local coordinate system is adopted
for this case. The equation connecting these two coordinate system is given below

Yglobal = Ylocal * cos( ) + Zlocal * sin ( )


Zglobal = Ylocal * sin( ) - Zlocal * cos ( ) + soffit width/2
Where
= angle of inclination of web with vertical

There are a total of 25.579 cables of which 21.579 are anchored in the webs while the rest 4 are
anchored in the soffit.

The box shall be stressed in single stages after 28 days with minimum compressive stress is 45MPa.

51
Ganga Bridge Between Arrah And Chapra P101010
Design of Box Girder Super Structure With Revised Dimensions of Segments (60m Span DN032RA

Cable No Cable Type No of Strands No of Cable Jacking Force (t)


1 19T15 15 1.579 304.95
2 19T15 19 2 386.27
3 19T15 19 2 386.27
4 19T15 19 2 386.27
5 19T15 19 2 386.27
6 19T15 19 2 386.27
7 19T15 19 2 386.27
8 19T15 19 2 386.27
9 19T15 19 2 386.27
10 19T15 19 2 386.27
11 19T15 19 2 386.27
12 19T15 19 2 386.27
13 19T15 19 2 386.27
Total No of cable 25.579
Provision has been kept in cable No 1 for stressing extra strand in case of emergency

The loss in prestressing force due to friction is based on the coefficient of friction and the wobble
coefficient as given above. Slip losses have been assumed to be 6mm. The calculation for the friction
and slips losses of each cable has been made using a standard in house software.

The Cable forces after friction and slip losses at any section are added togeter to get the net
Prestressing force and the Cg of the force at any section. These are given in the following pages

In addition the vertical component of the Presterssing force and the force due to cable curvature in plan
has also been calculated.

52
Ganga Bridge Between Arrah And Chapra P101010
Design of Box Girder Super Structure With Revised Dimensions of Segments (60m Span DN032RA

CABLE PROFILE

Cable No 1
Type of Cable 19T15
No of Strands 15
STAGE 1
Symmetrical Cable only half cable taken
Distances X are from cl of bearing
X (m) Y Elevation (m) Curve type Angle/Radius X (m) Z Plan (m) Curve type Angle/Radius

-0.45 3.980 -0.45 0.305


3.986 3.980 Straight 0.000 2.9 0.305 Straight 0.000
5.76 3.901 Circular 19.958 4.3999 0.268 Circular 30.019
27.7472191 1.944 Straight -0.089 4.4001 0.267 Straight -0.050
28.9 1.893 Circular 13.005 5.9 0.230 Circular 30.056
28.900 1.893 Straight 0.000 9.775 0.230 Straight 0.000
28.900 1.893 Straight 0.000 11.024 0.193 Circular 20.852
28.900 1.893 Straight 0.000 11.026 0.192 Straight -0.060
28.9 1.893 Straight 0.000 28.9 0.155 Straight 0.000

53
Ganga Bridge Between Arrah And Chapra P101010
Design of Box Girder Super Structure With Revised Dimensions of Segments (60m Span DN032RA

CABLE PROFILE
Cable No 2
Type of Cable 19T15
No of Strands 19
STAGE 1
Symmetrical Cable only half cable taken
Distances X are from cl of bearing
X (m) Y Elevation (m) Curve type Angle/Radius X (m) Z Plan (m) Curve type Angle/Radius

-0.45 3.623 -0.45 0.305


4.027 3.623 Straight 0.000 2.9 0.305 Straight 0.000
5.7 3.553 Circular 20.027 4.3999 0.268 Circular 30.019
27.7289728 1.704 Straight -0.084 4.4001 0.267 Straight -0.050
28.9 1.655 Circular 14.001 5.9 0.230 Circular 30.056
28.900 1.655 Straight 0.000 9.775 0.230 Straight 0.000
28.900 1.655 Straight 0.000 11.024 0.193 Circular 20.852
28.900 1.655 Straight 0.000 11.026 0.192 Straight -0.060
28.9 1.655 Straight 0.000 28.9 0.155 Straight 0.000

54
Ganga Bridge Between Arrah And Chapra P101010
Design of Box Girder Super Structure With Revised Dimensions of Segments (60m Span DN032RA

CABLE PROFILE
Cable No 3
Type of Cable 19T15
No of Strands 19
STAGE 1
Symmetrical Cable only half cable taken
Distances X are from cl of bearing
X (m) Y Elevation (m) Curve type Angle/Radius X (m) Z Plan (m) Curve type Angle/Radius

-0.45 3.266 -0.45 0.305


4.062 3.266 Straight 0.000 2.9 0.305 Straight 0.000
5.635 3.204 Circular 19.985 4.3999 0.268 Circular 30.019
27.7208838 1.463 Straight -0.079 4.4001 0.267 Straight -0.050
28.9 1.417 Circular 15.010 5.9 0.230 Circular 30.056
28.900 1.417 Straight 0.000 9.775 0.230 Straight 0.000
28.900 1.417 Straight 0.000 11.024 0.193 Circular 20.852
28.900 1.417 Straight 0.000 11.026 0.192 Straight -0.060
28.9 1.417 Straight 0.000 28.9 0.155 Straight 0.000

55
Ganga Bridge Between Arrah And Chapra P101010
Design of Box Girder Super Structure With Revised Dimensions of Segments (60m Span DN032RA

CABLE PROFILE
Cable No 4
Type of Cable 19T15
No of Strands 19
STAGE 1
Symmetrical Cable only half cable taken
Distances X are from cl of bearing
X (m) Y Elevation (m) Curve type Angle/Radius X (m) Z Plan (m) Curve type Angle/Radius

-0.45 2.909 -0.45 0.305


4.13727134 2.909 Straight 0.000 2.9 0.305 Straight 0.000
5.535 2.858 Circular 19.000 4.3999 0.268 Circular 30.019
27.79653 1.216 Straight -0.074 4.4001 0.267 Straight -0.050
28.9 1.175 Circular 15.000 5.9 0.230 Circular 30.056
28.900 1.175 Straight 0.000 9.775 0.230 Straight 0.000
28.900 1.175 Straight 0.000 11.024 0.193 Circular 20.852
28.900 1.175 Straight 0.000 11.026 0.192 Straight -0.060
28.9 1.175 Straight 0.000 28.9 0.155 Straight 0.000

56
Ganga Bridge Between Arrah And Chapra P101010
Design of Box Girder Super Structure With Revised Dimensions of Segments (60m Span DN032RA

CABLE PROFILE
Cable No 5
Type of Cable 19T15
No of Strands 19
STAGE 1
Symmetrical Cable only half cable taken
Distances X are from cl of bearing
X (m) Y Elevation (m) Curve type Angle/Radius X (m) Z Plan (m) Curve type Angle/Radius

-0.45 2.539 -0.45 0.305


4.40171316 2.539 Straight 0.000 2.9 0.305 Straight 0.000
5.635 2.497 Circular 18.000 4.3999 0.268 Circular 30.019
27.872261 0.969 Straight -0.069 4.4001 0.267 Straight -0.050
28.9 0.934 Circular 15.000 5.9 0.230 Circular 30.056
28.900 0.934 Straight 0.000 9.775 0.230 Straight 0.000
28.900 0.934 Straight 0.000 11.024 0.193 Circular 20.852
28.900 0.934 Straight 0.000 11.026 0.192 Straight -0.060
28.9 0.934 Straight 0.000 28.9 0.155 Straight 0.000

57
Ganga Bridge Between Arrah And Chapra P101010
Design of Box Girder Super Structure With Revised Dimensions of Segments (60m Span DN032RA

CABLE PROFILE
Cable No 6
Type of Cable 19T15
No of Strands 19
STAGE 1
Symmetrical Cable only half cable taken
Distances X are from cl of bearing
X (m) Y Elevation (m) Curve type Angle/Radius X (m) Z Plan (m) Curve type Angle/Radius

-0.45 2.171 -0.45 0.305


4.65070964 2.171 Straight 0.000 2.9 0.305 Straight 0.000
5.74 2.136 Circular 17.000 4.3999 0.268 Circular 30.019
27.948071 0.724 Straight -0.064 4.4001 0.267 Straight -0.050
28.9 0.694 Circular 14.994 5.9 0.230 Circular 30.056
28.900 0.694 Straight 0.000 9.775 0.230 Straight 0.000
28.900 0.694 Straight 0.000 11.024 0.193 Circular 20.852
28.900 0.694 Straight 0.000 11.026 0.192 Straight -0.060
28.9 0.694 Straight 0.000 28.9 0.155 Straight 0.000

58
Ganga Bridge Between Arrah And Chapra P101010
Design of Box Girder Super Structure With Revised Dimensions of Segments (60m Span DN032RA

CABLE PROFILE
Cable No 7
Type of Cable 19T15
No of Strands 19
STAGE 1
Symmetrical Cable only half cable taken
Distances X are from cl of bearing
X (m) Y Elevation (m) Curve type Angle/Radius X (m) Z Plan (m) Curve type Angle/Radius

-0.45 1.807 -0.45 0.305


4.82714819 1.807 Straight 0.000 2.9 0.305 Straight 0.000
5.82 1.778 Circular 17.000 4.3999 0.268 Circular 30.019
28.0239543 0.479 Straight -0.059 4.4001 0.267 Straight -0.050
28.9 0.453 Circular 15.000 5.9 0.230 Circular 30.056
28.900 0.453 Straight 0.000 9.775 0.230 Straight 0.000
28.900 0.453 Straight 0.000 11.024 0.193 Circular 20.852
28.900 0.453 Straight 0.000 11.026 0.192 Straight -0.060
28.9 0.453 Straight 0.000 28.9 0.155 Straight 0.000

59
Ganga Bridge Between Arrah And Chapra P101010
Design of Box Girder Super Structure With Revised Dimensions of Segments (60m Span DN032RA

CABLE PROFILE
Cable No 8
Type of Cable 19T15
No of Strands 19
STAGE 1
Symmetrical Cable only half cable taken
Distances X are from cl of bearing
X (m) Y Elevation (m) Curve type Angle/Radius X (m) Z Plan (m) Curve type Angle/Radius

-0.45 1.445 -0.45 0.305


4.99 1.445 Straight 0.000 2.9 0.305 Straight 0.000
5.90 1.421 Circular 17.000 4.3999 0.268 Circular 30.019
28.10 0.235 Straight -0.053 4.4001 0.267 Straight -0.050
28.90 0.213 Circular 15.000 5.9 0.230 Circular 30.056
28.90 0.213 Straight 0.000 9.775 0.230 Straight 0.000
28.90 0.213 Straight 0.000 11.024 0.193 Circular 20.852
28.90 0.213 Straight 0.000 11.026 0.192 Straight -0.060
28.90 0.213 Straight 0.000 28.9 0.155 Straight 0.000

60
Ganga Bridge Between Arrah And Chapra P101010
Design of Box Girder Super Structure With Revised Dimensions of Segments (60m Span DN032RA

CABLE PROFILE
Cable No 9
Type of Cable 19T15
No of Strands 19
STAGE 1
Symmetrical Cable only half cable taken
Distances X are from cl of bearing
X (m) Y Elevation (m) Curve type Angle/Radius X (m) Z Plan (m) Curve type Angle/Radius

-0.45 1.086 -0.45 0.305


5.04 1.086 Straight 0.000 2.9 0.305 Straight 0.000
5.90 1.065 Circular 17.000 4.3999 0.268 Circular 30.019
25.20 0.091 Straight -0.050 4.4001 0.267 Straight -0.050
27.70 0.130 Circular 49.644 5.9 0.230 Circular 30.056
28.90 0.130 Straight 0.000 9.775 0.230 Straight 0.000
28.90 0.130 Straight 0.000 11.024 0.193 Circular 20.852
28.90 0.130 Straight 0.000 11.026 0.192 Straight -0.060
28.90 0.130 Straight 0.000 28.9 0.155 Straight 0.000

61
Ganga Bridge Between Arrah And Chapra P101010
Design of Box Girder Super Structure With Revised Dimensions of Segments (60m Span DN032RA

CABLE PROFILE
Cable No 10
Type of Cable 19T15
No of Strands 19
STAGE 1
Symmetrical Cable only half cable taken
Distances X are from cl of bearing
X (m) Y Elevation (m) Curve type Angle/Radius X (m) Z Plan (m) Curve type Angle/Radius
-0.45 0.723 -0.45 0.305
4.92 0.723 Straight 0.000 2.9 0.305 Straight 0.000
5.90 0.694 Circular 17.000 4.3999 0.268 Circular 30.019
16.20 0.100 Straight -0.058 4.4001 0.267 Straight -0.050
18.70 0.130 Circular 43.442 5.9 0.230 Circular 30.056
28.90 0.130 Straight 0.000 9.775 0.230 Straight 0.000
28.90 0.130 Straight 0.000 11.024 0.193 Circular 20.852
28.90 0.130 Straight 0.000 11.026 0.192 Straight -0.060
28.90 0.130 Straight 0.000 12.275 0.155 Circular 20.889
28.9 0.130 Straight 0.000 18.700 3.361 Straight 0.000
28.9 0.130 Straight 0.000 21.700 3.213 Circular 30.479
28.9 0.130 Straight 0.000 23.200 3.139 Straight -0.049
28.9 0.130 Straight 0.000 28.9 2.991 Straight 0.000
* Y and Z are along global axis from X = 18.7 to X = 28.9

62
Ganga Bridge Between Arrah And Chapra P101010
Design of Box Girder Super Structure With Revised Dimensions of Segments (60m Span DN032RA

CABLE PROFILE
Cable No 11
Type of Cable 19T15
No of Strands 19
STAGE 1
Symmetrical Cable only half cable taken
Distances X are from cl of bearing
X (m) Y Elevation (m) Curve type Angle/Radius X (m) Z Plan (m) Curve type Angle/Radius
-0.45 0.362 -0.45 0.305
4.90 0.362 Straight 0.000 2.9 0.305 Straight 0.000
5.90 0.332 Circular 17.000 4.3999 0.268 Circular 30.019
9.80 0.102 Straight -0.059 4.4001 0.267 Straight -0.050
12.30 0.130 Circular 42.418 5.9 0.230 Circular 30.056
28.90 0.130 Straight 0.000 6.875 0.230 Straight 0.000
28.90 0.130 Straight 0.000 8.124 0.193 Circular 20.852
28.90 0.130 Straight 0.000 8.126 0.192 Straight -0.060
28.90 0.130 Straight 0.000 9.375 0.155 Circular 20.889
28.9 0.130 Straight 0.000 12.300 3.361 Straight 0.000
28.9 0.130 Straight 0.000 15.000 3.153 Circular 17.618
28.9 0.130 Straight 0.000 16.500 3.014 Straight -0.093
28.9 0.130 Straight 0.000 28.9 2.806 Straight 0.000
* Y and Z are along global axis from X = 12.3 to X = 28.9

63
Ganga Bridge Between Arrah And Chapra P101010
Design of Box Girder Super Structure With Revised Dimensions of Segments (60m Span DN032RA

CABLE PROFILE
Cable No 12
Type of Cable 19T15
No of Strands 19
STAGE 1
Symmetrical Cable only half cable taken
Distances X are from cl of bearing
X (m) Y Elevation (m) Curve type Angle/Radius X (m) Z Plan (m) Curve type Angle/Radius
-0.45 0.230 -0.45 1.530
3.69940064 0.230 Straight 0.000 28.9 1.530 Straight 0.000
5.9 0.223 Straight -0.003 28.9 1.530 Straight 0.000
9.6 0.153 Straight -0.019 28.9 1.530 Straight 0.000
12.1 0.130 Circular 133.100 28.9 1.530 Straight 0.000
28.9 0.130 Straight 0.000 28.9 1.530 Straight 0.000
* Y and Z are along global axis from X = -0.45 to X = 28.9

64
Ganga Bridge Between Arrah And Chapra P101010
Design of Box Girder Super Structure With Revised Dimensions of Segments (60m Span DN032RA

CABLE PROFILE
Cable No 13
Type of Cable 19T15
No of Strands 19
STAGE 1
Symmetrical Cable only half cable taken
Distances X are from cl of bearing
X (m) Y Elevation (m) Curve type Angle/Radius X (m) Z Plan (m) Curve type Angle/Radius
-0.45 0.230 -0.45 1.170
3.69940064 0.230 Straight 0.000 28.9 1.170 Straight 0.000
5.9 0.222 Straight -0.004 28.9 1.170 Straight 0.000
9.6 0.153 Straight -0.019 28.9 1.170 Straight 0.000
12.1 0.130 Circular 134.546 28.9 1.170 Straight 0.000
28.9 0.130 Straight 0.000 28.9 1.170 Straight 0.000
* Y and Z are along global axis from X = -0.35 to X = 28.9

65
Ganga Bridge Between Arrah And Chapra P101010
Design of Box Girder Super Structure With Revised Dimensions of Segments (60m Span DN032RA

CABLE FORCES AFTER FRICTION AND SLIP LOSSES

Cable No 1
Type of Cable 19T15
No of Strands 15
Jacking Force 304.9 t
Symmetrical Cable only half cable taken
Distances X are from anchorage point
X (m) Y (m) Z (m) Slope y Slope z Deviation Length (m) Pfriction (t) Pslip (t) (P/R)z (t/m)
-0.45 3.980 0.305 0.000 0.000 304.9 265.7 0.0
2.90 3.980 0.305 0.000 0.000 0.000 3.350 302.9 267.7 -6.3
3.986 3.980 0.285 0.000 -0.036 0.036 1.086 300.4 270.2 9.7
4.40 3.976 0.268 -0.021 -0.050 0.035 0.414 298.4 272.2 9.7
4.40 3.976 0.267 -0.021 -0.050 0.000 0.000 298.4 272.2 9.9
5.76 3.901 0.230 -0.089 -0.005 0.114 1.362 291.9 278.7 6.5
5.90 3.889 0.230 -0.089 0.000 0.005 0.141 291.6 279.0 0.0
9.78 3.544 0.230 -0.089 0.000 0.000 3.890 289.3 281.3 -9.5
11.02 3.432 0.193 -0.089 -0.060 0.060 1.254 285.7 285.0 0.0
11.026 3.432 0.192 -0.089 -0.060 0.000 0.002 285.7 285.0 9.5
12.275 3.321 0.155 -0.089 0.000 0.060 1.254 282.1 282.1 0.0
27.74722 1.944 0.155 -0.089 0.000 0.000 15.533 273.4 273.4 -14.9
28.9 1.893 0.155 0.000 0.000 0.089 1.154 268.7 268.7 0.0
29.442
Emergence Angle 0.000 degrees
Length of Cable 58.885 m
Cut Length 60.885 m
Null point 29.442 m
Pmin 268.7 t

Pslipleft 285.3 t Xslipleft 11.148 m


Pslipright 350.8 t Xslipright 46.652 m

Extension 209 mm

66
Ganga Bridge Between Arrah And Chapra P101010
Design of Box Girder Super Structure With Revised Dimensions of Segments (60m Span DN032RA

Cable No 2
Type of Cable 19T15
No of Strands 19
Jacking Force 386.3 t
Symmetrical Cable only half cable taken
Distances X are from anchorage point
X (m) Y (m) Z (m) Slope y Slope z Deviation Length (m) Pfriction (t) Pslip (t) (P/R)z (t/m)
-0.45 3.623 0.305 0.000 0.000 386.3 336.9 0.0
2.90 3.623 0.305 0.000 0.000 0.000 3.350 383.7 339.4 -8.0
4.027 3.623 0.284 0.000 -0.038 0.038 1.127 380.4 342.7 12.3
4.40 3.620 0.268 -0.019 -0.050 0.031 0.373 378.1 345.0 12.3
4.40 3.620 0.267 -0.019 -0.050 0.000 0.000 378.1 345.0 12.5
5.70 3.553 0.231 -0.084 -0.007 0.109 1.302 370.2 352.9 8.2
5.90 3.536 0.230 -0.084 0.000 0.007 0.201 369.6 353.5 0.0
9.78 3.211 0.230 -0.084 0.000 0.000 3.889 366.8 356.3 -12.0
11.02 3.106 0.193 -0.084 -0.060 0.060 1.254 362.2 361.0 0.0
11.026 3.106 0.192 -0.084 -0.060 0.000 0.002 362.2 361.0 12.1
12.275 3.001 0.155 -0.084 0.000 0.060 1.254 357.6 357.6 0.0
27.72897 1.704 0.155 -0.084 0.000 0.000 15.508 346.7 346.7 -17.6
28.9 1.655 0.155 0.000 0.000 0.084 1.172 341.0 341.0 0.0
29.432
Emergence Angle 0.000 degrees
Length of Cable 58.865 m
Cut Length 60.865 m
Null point 29.432 m
Pmin 341.0 t

Pslipleft 361.6 t Xslipleft 11.187 m


Pslipright 361.6 t Xslipright 46.613 m

Extension 209 mm

67
Ganga Bridge Between Arrah And Chapra P101010
Design of Box Girder Super Structure With Revised Dimensions of Segments (60m Span DN032RA

Cable No 3
Type of Cable 19T15
No of Strands 19
Jacking Force 386.3 t
Symmetrical Cable only half cable taken
Distances X are from anchorage point
X (m) Y (m) Z (m) Slope y Slope z Deviation Length (m) Pfriction (t) Pslip (t) (P/R)z (t/m)
-0.45 3.266 0.305 0.000 0.000 386.3 337.2 0.0
2.90 3.266 0.305 0.000 0.000 0.000 3.350 383.7 339.8 -8.0
4.062 3.266 0.283 0.000 -0.039 0.039 1.162 380.3 343.2 12.3
4.40 3.263 0.268 -0.017 -0.050 0.028 0.338 378.2 345.3 12.3
4.40 3.263 0.267 -0.017 -0.050 0.000 0.000 378.2 345.3 12.5
5.64 3.204 0.231 -0.079 -0.009 0.103 1.237 370.7 352.7 8.2
5.90 3.183 0.230 -0.079 0.000 0.009 0.266 370.0 353.5 0.0
9.78 2.878 0.230 -0.079 0.000 0.000 3.887 367.1 356.4 -12.0
11.02 2.779 0.193 -0.079 -0.060 0.060 1.253 362.5 361.0 0.0
11.026 2.779 0.192 -0.079 -0.060 0.000 0.002 362.5 361.0 12.1
12.275 2.681 0.155 -0.079 0.000 0.060 1.253 357.9 357.9 0.0
27.72088 1.463 0.155 -0.079 0.000 0.000 15.494 347.0 347.0 -16.4
28.9 1.417 0.155 0.000 0.000 0.079 1.180 341.6 341.6 0.0
29.423
Emergence Angle 0.000 degrees
Length of Cable 58.846 m
Cut Length 60.846 m
Null point 29.423 m
Pmin 341.6 t

Pslipleft 361.7 t Xslipleft 11.228 m


Pslipright 361.7 t Xslipright 46.572 m

Extension 209 mm

68
Ganga Bridge Between Arrah And Chapra P101010
Design of Box Girder Super Structure With Revised Dimensions of Segments (60m Span DN032RA

Cable No 4
Type of Cable 19T15
No of Strands 19
Jacking Force 386.3 t
Symmetrical Cable only half cable taken
Distances X are from anchorage point
X (m) Y (m) Z (m) Slope y Slope z Deviation Length (m) Pfriction (t) Pslip (t) (P/R)z (t/m)
-0.45 2.909 0.305 0.000 0.000 386.3 337.5 0.0
2.90 2.909 0.305 0.000 0.000 0.000 3.350 383.7 340.1 -8.0
4.137 2.909 0.279 0.000 -0.041 0.041 1.238 380.1 343.7 13.0
4.40 2.908 0.268 -0.014 -0.050 0.023 0.263 378.4 345.4 13.0
4.40 2.908 0.267 -0.014 -0.050 0.000 0.000 378.4 345.4 13.2
5.54 2.858 0.232 -0.074 -0.012 0.098 1.137 371.3 352.5 8.2
5.90 2.831 0.230 -0.074 0.000 0.012 0.366 370.3 353.5 0.0
9.78 2.545 0.230 -0.074 0.000 0.000 3.886 367.4 356.4 -12.0
11.02 2.453 0.193 -0.074 -0.060 0.060 1.253 362.8 361.0 0.0
11.026 2.453 0.192 -0.074 -0.060 0.000 0.002 362.8 361.0 12.1
12.275 2.361 0.155 -0.074 0.000 0.060 1.253 358.2 358.2 0.0
27.79653 1.216 0.155 -0.074 0.000 0.000 15.564 347.2 347.2 -16.5
28.9 1.175 0.155 0.000 0.000 0.074 1.104 342.1 342.1 0.0
29.415
Emergence Angle 0.000 degrees
Length of Cable 58.829 m
Cut Length 60.829 m
Null point 29.415 m
Pmin 342.1 t

Pslipleft 361.9 t Xslipleft 11.267 m


Pslipright 361.9 t Xslipright 46.533 m

Extension 210 mm

69
Ganga Bridge Between Arrah And Chapra P101010
Design of Box Girder Super Structure With Revised Dimensions of Segments (60m Span DN032RA

Cable No 5
Type of Cable 19T15
No of Strands 19
Jacking Force 386.3 t
Symmetrical Cable only half cable taken
Distances X are from anchorage point
X (m) Y (m) Z (m) Slope y Slope z Deviation Length (m) Pfriction (t) Pslip (t) (P/R)z (t/m)
-0.45 2.539 0.305 0.000 0.000 386.3 338.0 0.0
2.90 2.539 0.305 0.000 0.000 0.000 3.350 383.7 340.6 -8.0
4.400 2.539 0.268 0.000 -0.050 0.050 1.500 379.3 345.0 0.0
4.40 2.539 0.267 0.000 -0.050 0.000 0.000 379.3 345.0 8.1
4.40 2.539 0.267 0.000 -0.050 0.000 0.002 379.3 345.0 13.9
5.64 2.497 0.231 -0.069 -0.009 0.110 1.235 371.4 352.9 8.2
5.90 2.478 0.230 -0.069 0.000 0.009 0.266 370.6 353.7 0.0
9.78 2.212 0.230 -0.069 0.000 0.000 3.884 367.7 356.5 -12.1
11.02 2.127 0.193 -0.069 -0.060 0.060 1.253 363.1 361.2 0.0
11.026 2.126 0.192 -0.069 -0.060 0.000 0.002 363.1 361.2 12.1
12.275 2.041 0.155 -0.069 0.000 0.060 1.253 358.5 358.5 0.0
27.87226 0.969 0.155 -0.069 0.000 0.000 15.634 347.5 347.5 -16.5
28.9 0.934 0.155 0.000 0.000 0.069 1.028 342.7 342.7 0.0
29.406
Emergence Angle 0.000 degrees
Length of Cable 58.812 m
Cut Length 60.812 m
Null point 29.406 m
Pmin 342.7 t

Pslipleft 362.1 t Xslipleft 11.286 m


Pslipright 362.1 t Xslipright 46.514 m

Extension 210 mm

70
Ganga Bridge Between Arrah And Chapra P101010
Design of Box Girder Super Structure With Revised Dimensions of Segments (60m Span DN032RA

Cable No 6
Type of Cable 19T15
No of Strands 19
Jacking Force 386.3 t
Symmetrical Cable only half cable taken
Distances X are from anchorage point
X (m) Y (m) Z (m) Slope y Slope z Deviation Length (m) Pfriction (t) Pslip (t) (P/R)z (t/m)
-0.45 2.171 0.305 0.000 0.000 386.3 338.5 0.0
2.90 2.171 0.305 0.000 0.000 0.000 3.350 383.7 341.1 -8.0
4.400 2.171 0.268 0.000 -0.050 0.050 1.500 379.3 345.5 0.0
4.40 2.171 0.267 0.000 -0.050 0.000 0.000 379.3 345.5 8.1
4.65 2.171 0.256 0.000 -0.042 0.008 0.251 378.6 346.2 14.6
5.74 2.136 0.230 -0.064 -0.005 0.100 1.090 371.4 353.4 8.3
5.90 2.126 0.230 -0.064 0.000 0.005 0.160 370.9 353.8 0.0
9.78 1.880 0.230 -0.064 0.000 0.000 3.883 368.1 356.7 -12.1
11.02 1.800 0.193 -0.064 -0.060 0.060 1.252 363.4 361.3 0.0
11.026 1.800 0.192 -0.064 -0.060 0.000 0.002 363.4 361.3 12.1
12.275 1.721 0.155 -0.064 0.000 0.060 1.252 358.8 358.8 0.0
27.94807 0.724 0.155 -0.064 0.000 0.000 15.705 347.7 347.7 -16.5
28.9 0.694 0.155 0.000 0.000 0.064 0.952 343.3 343.3 0.0
29.398
Emergence Angle 0.000 degrees
Length of Cable 58.796 m
Cut Length 60.796 m
Null point 29.398 m
Pmin 343.3 t

Pslipleft 362.4 t Xslipleft 11.309 m


Pslipright 362.4 t Xslipright 46.491 m

Extension 210 mm

71
Ganga Bridge Between Arrah And Chapra P101010
Design of Box Girder Super Structure With Revised Dimensions of Segments (60m Span DN032RA

Cable No 7
Type of Cable 19T15
No of Strands 19
Jacking Force 386.3 t
Symmetrical Cable only half cable taken
Distances X are from anchorage point
X (m) Y (m) Z (m) Slope y Slope z Deviation Length (m) Pfriction (t) Pslip (t) (P/R)z (t/m)
-0.45 1.807 0.305 0.000 0.000 386.3 338.9 0.0
2.90 1.807 0.305 0.000 0.000 0.000 3.350 383.7 341.5 -8.0
4.400 1.807 0.268 0.000 -0.050 0.050 1.500 379.3 345.9 0.0
4.40 1.807 0.267 0.000 -0.050 0.000 0.000 379.3 345.9 8.1
4.83 1.807 0.249 0.000 -0.036 0.014 0.427 378.1 347.1 14.7
5.82 1.778 0.230 -0.059 -0.003 0.092 0.993 371.5 353.7 8.3
5.90 1.773 0.230 -0.059 0.000 0.003 0.080 371.3 353.9 0.0
9.78 1.546 0.230 -0.059 0.000 0.000 3.882 368.4 356.8 -12.1
11.02 1.473 0.193 -0.059 -0.060 0.060 1.252 363.7 361.4 0.0
11.026 1.473 0.192 -0.059 -0.060 0.000 0.002 363.7 361.4 12.1
12.275 1.400 0.155 -0.059 0.000 0.060 1.252 359.1 359.1 0.0
28.02395 0.479 0.155 -0.059 0.000 0.000 15.776 348.0 348.0 -16.5
28.9 0.453 0.155 0.000 0.000 0.059 0.876 343.9 343.9 0.0
29.391
Emergence Angle 0.000 degrees
Length of Cable 58.782 m
Cut Length 60.782 m
Null point 29.391 m
Pmin 343.9 t

Pslipleft 362.6 t Xslipleft 11.338 m


Pslipright 362.6 t Xslipright 46.462 m

Extension 210 mm

72
Ganga Bridge Between Arrah And Chapra P101010
Design of Box Girder Super Structure With Revised Dimensions of Segments (60m Span DN032RA

Cable No 8
Type of Cable 19T15
No of Strands 19
Jacking Force 386.3 t
Symmetrical Cable only half cable taken
Distances X are from anchorage point
X (m) Y (m) Z (m) Slope y Slope z Deviation Length (m) Pfriction (t) Pslip (t) (P/R)z (t/m)
-0.45 1.445 0.305 0.000 0.000 386.3 339.3 0.0
2.90 1.445 0.305 0.000 0.000 0.000 3.350 383.7 341.9 -8.0
4.400 1.445 0.268 0.000 -0.050 0.050 1.500 379.3 346.3 0.0
4.40 1.445 0.267 0.000 -0.050 0.000 0.000 379.3 346.3 8.1
4.99 1.445 0.244 0.000 -0.030 0.020 0.594 377.6 348.0 14.8
5.90 1.421 0.230 -0.053 0.000 0.084 0.907 371.6 354.0 0.0
9.78 1.214 0.230 -0.053 0.000 0.000 3.881 368.7 356.9 -12.1
11.02 1.147 0.193 -0.053 -0.060 0.060 1.251 364.0 361.5 0.0
11.03 1.147 0.192 -0.053 -0.060 0.000 0.002 364.0 361.5 12.1
12.275 1.080 0.155 -0.053 0.000 0.060 1.251 359.5 359.5 0.0
28.09991 0.235 0.155 -0.053 0.000 0.000 15.847 348.2 348.2 -16.5
28.9 0.213 0.155 0.000 0.000 0.053 0.800 344.5 344.5 0.0
29.384
Emergence Angle 0.000 degrees
Length of Cable 58.769 m
Cut Length 60.769 m
Null point 29.384 m
Pmin 344.5 t

Pslipleft 362.8 t Xslipleft 11.369 m


Pslipright 362.8 t Xslipright 46.431 m

Extension 210 mm

73
Ganga Bridge Between Arrah And Chapra P101010
Design of Box Girder Super Structure With Revised Dimensions of Segments (60m Span DN032RA

Cable No 9
Type of Cable 19T15
No of Strands 19
Jacking Force 386.3 t
Symmetrical Cable only half cable taken
Distances X are from anchorage point
X (m) Y (m) Z (m) Slope y Slope z Deviation Length (m) Pfriction (t) Pslip (t) (P/R)z (t/m)
-0.45 1.086 0.305 0.000 0.000 386.3 339.5 0.0
2.90 1.086 0.305 0.000 0.000 0.000 3.350 383.7 342.1 -8.0
4.400 1.086 0.268 0.000 -0.050 0.050 1.500 379.3 346.5 0.0
4.40 1.086 0.267 0.000 -0.050 0.000 0.000 379.3 346.5 8.1
5.04 1.086 0.242 0.000 -0.029 0.021 0.644 377.4 348.3 14.8
5.90 1.065 0.230 -0.050 0.000 0.079 0.857 371.8 354.0 0.0
9.78 0.869 0.230 -0.050 0.000 0.000 3.880 368.9 356.9 -12.1
11.02 0.806 0.193 -0.050 -0.060 0.060 1.251 364.2 361.5 0.0
11.03 0.806 0.192 -0.050 -0.060 0.000 0.002 364.2 361.5 12.1
12.275 0.743 0.155 -0.050 0.000 0.060 1.251 359.6 359.6 0.0
25.2 0.091 0.155 -0.050 0.000 0.000 12.941 350.4 350.4 -5.0
27.7 0.130 0.155 0.000 0.000 0.050 2.501 345.7 345.7 0.0
28.9 0.130 0.155 0.000 0.000 0.000 1.200 344.9 344.9 0.0
29.378
Emergence Angle 0.000 degrees
Length of Cable 58.756 m
Cut Length 60.756 m
Null point 29.378 m
Pmin 344.9 t

Pslipleft 362.9 t Xslipleft 11.392 m


Pslipright 362.9 t Xslipright 46.408 m

Extension 210 mm

74
Ganga Bridge Between Arrah And Chapra P101010
Design of Box Girder Super Structure With Revised Dimensions of Segments (60m Span DN032RA

Cable No 10
Type of Cable 19T15
No of Strands 19
Jacking Force 386.3 t
Symmetrical Cable only half cable taken
Distances X are from anchorage point
X (m) Y (m) Z (m) Slope y Slope z Deviation Length (m) Pfriction (t) Pslip (t) (P/R)z (t/m)
-0.45 0.723 0.305 0.000 0.000 386.3 339.0 0.0
2.90 0.723 0.305 0.000 0.000 0.000 3.350 383.7 341.6 -8.0
4.400 0.723 0.268 0.000 -0.050 0.050 1.500 379.3 346.0 0.0
4.40 0.723 0.267 0.000 -0.050 0.000 0.000 379.3 346.0 8.1
4.92 0.723 0.246 0.000 -0.033 0.017 0.521 377.8 347.5 14.8
5.90 0.694 0.230 -0.058 0.000 0.090 0.980 371.3 354.0 0.0
9.78 0.471 0.230 -0.058 0.000 0.000 3.881 368.4 356.8 -12.1
11.02 0.399 0.193 -0.058 -0.060 0.060 1.252 363.8 361.5 0.0
11.03 0.399 0.192 -0.058 -0.060 0.000 0.002 363.8 361.5 12.1
12.275 0.327 0.155 -0.058 0.000 0.060 1.252 359.2 359.2 0.0
16.2 0.100 0.155 -0.058 0.000 0.000 3.932 356.4 356.4 -4.4
18.7 0.130 3.361 0.000 0.000 0.058 2.501 351.1 351.1 4.8
21.7 0.130 3.213 0.000 -0.049 0.049 3.001 346.1 346.1 0.0
23.2 0.130 3.139 0.000 -0.049 0.000 1.502 345.1 345.1 -11.2
24.7 0.130 2.991 0.000 0.000 0.049 1.500 341.2 341.2 0.0
28.9 0.130 2.991 0.000 0.000 0.000 4.200 338.3 338.3 0.0
29.374
Emergence Angle 0.000 degrees
Length of Cable 58.748 m
Cut Length 60.748 m
Null point 29.374 m
Pmin 338.3 t

Pslipleft 362.6 t Xslipleft 11.337 m


Pslipright 362.6 t Xslipright 46.463 m

Extension 208 mm

75
Ganga Bridge Between Arrah And Chapra P101010
Design of Box Girder Super Structure With Revised Dimensions of Segments (60m Span DN032RA

Cable No 11
Type of Cable 19T15
No of Strands 19
Jacking Force 386.3 t
Symmetrical Cable only half cable taken
Distances X are from anchorage point
X (m) Y (m) Z (m) Slope y Slope z Deviation Length (m) Pfriction (t) Pslip (t) (P/R)z (t/m)
-0.45 0.362 0.305 0.000 0.000 386.3 335.6 0.0
2.90 0.362 0.305 0.000 0.000 0.000 3.350 383.7 338.2 -7.9
4.400 0.362 0.268 0.000 -0.050 0.050 1.500 379.3 342.6 0.0
4.40 0.362 0.267 0.000 -0.050 0.000 0.000 379.3 342.6 8.0
4.90 0.362 0.247 0.000 -0.033 0.017 0.498 377.9 344.0 14.6
5.90 0.332 0.230 -0.059 0.000 0.093 1.003 371.2 350.7 0.0
6.88 0.275 0.230 -0.059 0.000 0.000 0.977 370.5 351.4 -11.9
8.12 0.201 0.193 -0.059 -0.060 0.060 1.252 365.8 356.1 0.0
8.13 0.201 0.192 -0.059 -0.060 0.000 0.002 365.8 356.1 12.0
9.375 0.127 0.155 -0.059 0.000 0.060 1.252 361.2 360.7 0.0
9.8 0.102 0.155 -0.059 0.000 0.000 0.426 360.9 360.9 -4.5
12.3 0.130 3.361 0.000 0.000 0.059 2.501 355.5 355.5 9.7
15 0.130 3.153 0.000 -0.093 0.093 2.703 348.1 348.1 0.0
16.5 0.130 3.014 0.000 -0.093 0.000 1.506 347.0 347.0 -21.0
18 0.130 2.806 0.000 0.000 0.093 1.502 340.6 340.6 0.0
28.9 0.130 2.806 0.000 0.000 0.000 10.900 333.2 333.2 0.0
29.371
Emergence Angle 0.000 degrees
Length of Cable 58.743 m
Cut Length 60.743 m
Null point 29.371 m
Pmin 333.2 t

Pslipleft 360.9 t Xslipleft 9.724 m


Pslipright 360.9 t Xslipright 48.076 m

Extension 205 mm

76
Ganga Bridge Between Arrah And Chapra P101010
Design of Box Girder Super Structure With Revised Dimensions of Segments (60m Span DN032RA

Cable No 12
Type of Cable 19T15
No of Strands 19
Jacking Force 386.3 t
Symmetrical Cable only half cable taken
Distances X are from anchorage point
X (m) Y (m) Z (m) Slope y Slope z Deviation Length (m) Pfriction (t) Pslip (t) (P/R)z (t/m)
-0.45 0.230 1.530 0.000 0.000 386.3 352.7 0.0
3.70 0.230 1.530 0.000 0.000 0.000 4.149 383.1 355.9 0.0
5.900 0.223 1.530 -0.019 0.000 0.019 2.201 380.2 358.8 0.0
9.60 0.153 1.530 -0.019 0.000 0.000 3.701 377.4 361.6 0.0
12.10 0.130 1.530 0.000 0.000 0.019 2.500 374.3 364.7 0.0
28.90 0.130 1.530 0.000 0.000 0.000 16.800 361.9 361.9 0.0
29.351
Emergence Angle 0.000 degrees
Length of Cable 58.702 m
Cut Length 60.702 m
Null point 29.351 m
Pmin 361.9 t

Pslipleft 369.5 t Xslipleft 18.572 m


Pslipright 369.5 t Xslipright 39.228 m

Extension 216 mm

77
Ganga Bridge Between Arrah And Chapra P101010
Design of Box Girder Super Structure With Revised Dimensions of Segments (60m Span DN032RA

Cable No 13
Type of Cable 19T15
No of Strands 19
Jacking Force 386.3 t
Symmetrical Cable only half cable taken
Distances X are from anchorage point
X (m) Y (m) Z (m) Slope y Slope z Deviation Length (m) Pfriction (t) Pslip (t) (P/R)z (t/m)
-0.45 0.230 1.170 0.000 0.000 386.3 353.3 0.0
3.70 0.230 1.170 0.000 0.000 0.000 4.149 383.1 356.5 0.0
5.900 0.222 1.170 -0.015 0.000 0.015 2.201 380.4 359.1 0.0
9.60 0.167 1.170 -0.015 0.000 0.000 3.700 377.6 361.9 0.0
12.10 0.130 1.170 0.000 0.000 0.015 2.500 374.8 364.7 0.0
28.90 0.130 1.170 0.000 0.000 0.000 16.800 362.4 362.4 0.0
29.351
Emergence Angle 0.000 degrees
Length of Cable 58.701 m
Cut Length 60.701 m
Null point 29.351 m
Pmin 362.4 t

Pslipleft 369.8 t Xslipleft 18.857 m


Pslipright 369.8 t Xslipright 38.943 m

Extension 216 mm

78
Ganga Bridge Between Arrah And Chapra P101010
Design of Box Girder Super Structure With Revised Dimensions of Segments (60m Span DN032RA

SUMMARRY OF CABLE FORCES AFTER FRICTION AND SLIP LOSSES


AT SECTIONS

Distance Stage1
Section from end No of Ecc from
Hor Force Ver force
No Support Cables bottom
(m) (m) (t) (t)
1 1 1.100 25.579 1.473 8734.703
2 3 2.900 25.579 1.473 8770.099
3 6 5.900 25.579 1.402 9048.165
4 8 7.800 25.579 1.321 9086.335
5 10 9.700 25.579 1.237 9132.404
6 13 12.700 25.579 1.080 9166.835
7 16 15.700 25.579 0.971 9118.512
8 19 18.700 25.579 0.867 9067.581
9 22 21.700 25.579 0.770 8998.741
10 25 24.700 25.579 0.673 8923.936
11 28 27.700 25.579 0.576 8889.472
12 29 28.900 25.579 0.577 8848.505

79
Ganga Bridge Between Arrah And Chapra P101010
Design of Box Girder Super Structure With Revised Dimensions of Segments (60m Span DN032RA

EFFECT OF TEMPERATURE GRADIENT

There are no stresses developed in structure due to uniform rise/fall in temperature as the structure is
free to expand/contract. However due to temperature gradient along depth of box (rise and fall case),
eigen stresses are developed.

The temperature gradient along depth (rise/fall) have been considered as per fig 10 of IRC:6-2010 as
shown below.

Temperature Gradient

o o
17.80 C 10.6 C
150

250
o o
4 C 0.7 C
250

200
3.4

200
o
0.8 C
150

250
o o
2.1 C 6.6 C
(Temp. Rise) (Temp. Fall)

The eigen stresses have been calculated for each section along with the force and eccentricity based on
full value of E value.

The resultant temperature stresses have been combined later with stresses due to other effects like DL,
SIDL etc in tabular manner. Only 50% live load has been considered for load combination with
temperature gradient. In case there tension in the box in this load combination then untensioned steel has
been provided as per requirement.

80
Ganga Bridge Between Arrah And Chapra P101010
Design of Box Girder Super Structure With Revised Dimensions of Segments (60m Span DN032RA

EIGEN STRESSES DUE TO TEMPERATURE

Rise in Temperature Fall in Temperature


Section No Location
Top Stress Bottom Stress Top Stress Bottom Stress
2 2 2 2
(m) T/m T/m T/m T/m

1.000 1.100 715.30 82.30 -344.59 4.30


2.000 2.900 715.30 82.30 -344.59 4.30
3.000 5.900 715.30 82.30 -341.24 24.01
4.000 7.800 715.30 82.30 -341.24 24.01
5.000 9.700 715.30 82.30 -341.24 24.01
6.000 12.700 715.30 82.30 -341.24 24.01
7.000 15.700 715.30 82.30 -341.24 24.01
8.000 18.700 715.30 82.30 -341.24 24.01
9.000 21.700 715.30 82.30 -341.24 24.01
10.000 24.700 715.30 82.30 -341.24 24.01
11.000 27.700 715.30 82.30 -341.24 24.01
12.000 28.900 432.4 130.8 -425.20 -17.40

81
Ganga Bridge Between Arrah And Chapra P101010
Design of Box Girder Super Structure With Revised Dimensions of Segments (60m Span DN032RA

STRESS CHECK AT VARIOUS SECTIONS AT DIFFERENT STAGES

SECTIONS FOR STRESS CHECK


Sec. No. Location Dist. From C.L. Brg.
1 1.100 m
2 2.900 m
3 5.900 m
4 7.800 m
5 9.700 m
6 12.700 m
7 15.700 m
8 18.700 m
9 21.700 m
10 24.700 m
11 27.700 m
12 28.900 m
All these are the key points from flexure and shear considerations which are being investigated in the
design. The calculations for stresses and losses are presented here in tabular form which is self
explanatory.

Forces due to prestress after friction and slip losses are input along with sectional properties and
various design moments like dead load, SIDL and live load

Stagewise calculations of losses and stresses is done in systematic manner. The following are the
stages for Stress Check:

1 Immediately after Prestressing. Prestressing shall be done when web and deck slab concrete is
28 days old with a minimum strength of 45 MPa.
2 Immediately after prestessing considering elastic shortening loss.
3 Immediately after prestessing considering elastic relaxation loss.
4 Immediately after SIDL is laid.
5 At 90 days considering creep, shrinkage & relaxation losses as per clause IRC112

6 Immediately after SIDL is laid.


7 In service condition considering moment due to foot path live load and positive moment due to
live load.
8 After losses at infinity days without live load.

9 After losses at infinity days with live load

10 Considering rise in temperature with with 50% live load.


11 Considering fall in temperature without live load.

82
Ganga Bridge Between Arrah And Chapra P101010
Design of Box Girder Super Structure With Revised Dimensions of Segments (60m Span DN032RA

Time dependent Losses in Prestress for each of these stage have been Calculated as follows

Losses due to elastic shortening of concrete has been calculated as given below

Elastic Shortening = (final stress - initial stress)/2 * area of cable * E steel / Econc

Where the initial and final stresses in concrete are calculated at net cg of Cable before and after the
elastic shortening losses.

The effect of elastic shortening has been taken into account as per sequence of prestressing.

Losses due to Creep of Concrete has been calculated as given below:

Creep = (Initial Stress + final Stress) / 2 * (initial creep - final creep) * E steel * area of Cable

Where
Initial and final stresses in concrete are calculated at net cg of Cable before and after the losses

Initial creep and final creep in concrete is as per IRC112.

Losses due to Shrinkage of Concrete has been calculated as given below

Shrinkage = (Initial residual shrinkage - final residual shrinkage ) * Esteel * area of Cable

Where
Initial Shrinkage and final Shrinkage in concrete is as per IRC112

Losses due to Relaxation in steel has been calculated as given below

The 1000 hr relaxation loss based on low relaxation steel and average initial force in the cable is
calculated as per IRC 112. The total relaxation losses is taken 3 times the 1000hr relaxation losses.
Losses in intermediate time is calculated as per IRC 112

83
Ganga Bridge Between Arrah And Chapra P101010
Design of Box Girder Super Structure With Revised Dimensions of Segments (60m Span DN032RA

Creep and Shrinkage Calculations as Per IRC 112

S.No Parameters Units


Creep strain calculations
1 Cross Sectional area,Ac m2 10.37
2 Perimeter,u m 43.70

3 Notional Size of member,h=2Ac/u mm 475


4 fck N/mm2 45.00
5 fcm=10+fck N/mm2 55
6 Relative Humidity,RH % 80.00
7 =sqrt(45/fcm) 0.90
8 H 1280
9 Age of concrte at the time of loading,t0 days 90.00
10 Age of concrte at the time considered,t days 120.00
11 (t,t0) 0.322
12 (,t0) 1.256
13 (t,t0) 0.404

Shrinkage calculations
Age of concrte at the time considered,t days 120.00 90.000 50000.000
Age of concrte at the time of beginning of dry
15 shrinkage,ts days 14.00 14.00 14.00
16 kh 0.706 0.706 0.706
17 ds(t,ts) 0.204 0.155 0.992
18 cd 0.000252 0.000252 0.000252
19 cd(t) 0.0000363 0.0000276 0.0001765
20 as 0.888 0.850 1.000
21 cw 0.000065 0.000065 0.000065
22 ca(t) 0.000058 0.000055 0.000065
23 cs=cs+cs 0.000094 0.000083 0.000242

84
Ganga Bridge Between Arrah And Chapra P101010
Design of Box Girder Super Structure With Revised Dimensions of Segments (60m Span DN032RA

TIME DEPENDENT LOSSES IN PRESTRESSED CABLES

Grade of Concrete M 45 Elastic Shortening losses


Conc. Strength ( 28 days) 45.00 E Steel 1.950E+07 t/m2
E CONC 28day 3.35E+06 t/m2
Type of Cable 19T15 E CONC 28day 3.35E+06 t/m2
Area of One Cable (m2) 2.660E-03
UTS of Cable (t) 504.92

Cable Average Stress


Elastic Shortening loss
Stage At Cable cg
Time

Actual = (final stress


Initial Final Assumed
- initial stress)/2*
Stress Stress Econc (t/m2) Elastic
0.00266 * 19500000
(t/m2) (t/m2) Shortening (t)
/ Econc

Immediate after stage1


Prestressing stage 1 0.000 903.6 3354102.0 7.021 6.987
120 day after casting (before stage 1 890.7 857.7
SIDL)

At infinite time stage 1 720.7 582.9 0.000

85
Ganga Bridge Between Arrah And Chapra P101010
Design of Box Girder Super Structure With Revised Dimensions of Segments (60m Span DN032RA

TIME DEPENDENT LOSSES IN PRESTRESSED CABLES

Grade of Concrete M 45 Relaxation losses (As per IRC112) % of 1000hr loss


Conc. Strength ( 28 days) 45.00 Immediatr after stressing 120 hours 47.0%
E CONC 28day
Immediatr after stressing 120 hours 47.0%
Type of Cable 19T15 E CONC 28day
At 90 days 2160 hours 100.0%
Area of One Cable (m2) 2.660E-03 At 120 days 2880 hours 100.0%
UTS of Cable (t) 504.92

Cable Average Stress


Relaxation Losses
Stage At Cable cg
Time

Relaxation loss
= %age of total
Initial Final Av. Force/Cable Total Relaxation %age of
Relaxation
Stress Stress after Elastic Losses =3*1000 HR total
*Total
(t/m2) (t/m2) Shortening (t) losses (t) Relaxation
Relaxation
Loss (t)

Immediate after stage1


15.7%
Prestressing stage 1 0.000 903.6 344.60 23.58 3.70
120 day after casting (before stage 1 890.7 857.7 17.7% 4.17
SIDL)

At infinite time stage 1 720.7 582.9 66.7% 15.73

86
Ganga Bridge Between Arrah And Chapra P101010
Design of Box Girder Super Structure With Revised Dimensions of Segments (60m Span DN032RA

TIME DEPENDENT LOSSES IN PRESTRESSED CABLES

Grade of Concrete M 45 Creep Strain per ( as per IRC:112 )


Conc. Strength ( 28 days) 45.00 at 90 days 4.383E-05
E CONC 28day
at 120 days 1.204E-04
Type of Cable 19T15 E CONC 28day
at infinity 3.745E-04
Area of One Cable (m2) 2.660E-03
UTS of Cable (t) 504.92

Cable Average Stress


Creep Losses
Stage At Cable cg
Time

Actual Creep = (
Initial Final Initial Stress + final
Creep Strain Creep Strain Creep
Stress Stress Stress ) / 2 * ( initial -
(Initial) (final) assumed (t)
(t/m2) (t/m2) final ) * 19500000 *
0.00266 / 1000

Immediate after stage1


Prestressing stage 1 0.000 903.6 0.000
120 day after casting (before stage 1 890.7 857.7 0.00004 0.00012 3.48 3.47
SIDL)

At infinite time stage 1 720.7 582.9 0.00012 0.0004 8.63 8.59

87
Ganga Bridge Between Arrah And Chapra P101010
Design of Box Girder Super Structure With Revised Dimensions of Segments (60m Span DN032RA

TIME DEPENDENT LOSSES IN PRESTRESSED CABLES

Grade of Concrete M 45 Shrinkage Strain ( as per IRC:112)


Conc. Strength ( 28 days) 45.00 at 90 days 8.288E-05
E CONC 28day
at 120 days 9.404E-05
Type of Cable 19T15 E CONC 28day
at infinity 2.415E-04
Area of One Cable (m2) 2.660E-03
UTS of Cable (t) 504.92

Cable Average Stress


Shrinkage
Stage At Cable cg
Time

Initial Final Shrinkage loss = ( Initial -


Shrinkage Strain Shrinkage Strain
Stress Stress final ) * 19500000 *
(Initial) (Final)
(t/m2) (t/m2) 0.00266

Immediate after stage1


Prestressing stage 1 0.000 903.6
120 day after casting (before stage 1 890.7 857.7 0.00009 0.00009 0.00
SIDL)

At infinite time stage 1 720.7 582.9 0.00009 0.000 7.66

88
Ganga Bridge Between Arrah And Chapra P101010
Design of Box Girder Super Structure With Revised Dimensions of Segments (60m Span DN032RA

STRESS CHECK FOR BOX GIRDER

Sr. Section No. SEC#1 SEC#2 SEC#3 SEC#4 SEC#5 SEC#6 SEC#7 SEC#8 SEC#9 SEC#10 SEC#11 SEC#12
No
Distance from end support (m) 1.100 2.900 5.900 7.800 9.700 12.700 15.700 18.700 21.700 24.700 27.700 28.900
1. AREA (m 2 ) 13.739 13.739 13.739 12.362 12.362 10.371 10.371 10.371 10.371 10.371 10.371 10.371
2. Total Depth (m) 3.400 3.400 3.400 3.400 3.400 3.400 3.400 3.400 3.400 3.400 3.400 3.400
3. MOI (m4) 20.576 20.576 20.576 19.716 19.716 16.023 16.023 16.023 16.023 16.023 16.023 16.023
4. Y top (m) 1.410 1.410 1.410 1.372 1.372 1.187 1.187 1.187 1.187 1.187 1.187 1.187
5. Y bot (m) 1.990 1.990 1.990 2.028 2.028 2.213 2.213 2.213 2.213 2.213 2.213 2.213
6. Z top (m3) 14.593 14.593 14.593 14.370 14.370 13.499 13.499 13.499 13.499 13.499 13.499 13.499
7. Z bot (m3) 10.340 10.340 10.340 9.722 9.722 7.240 7.240 7.240 7.240 7.240 7.240 7.240

DL MOMENT
8. DL MOMENT ( tm ) 881.2 2234.0 4248.9 5376.3 6392.1 7780.0 8923.4 9833.5 10510 10954 11164 11182.2
9. TOP STRESS (t/m 2 ) 60.4 153.1 291.2 374.1 444.8 576.4 661.1 728.5 778.6 811.5 827.0 828.4
10. BOTTOM STRESS (t/m 2 ) -85.2 -216.1 -410.9 -553.0 -657.5 -1074.5 -1232.5 -1358.1 -1451.6 -1512.8 -1541.8 -1544.4

STAGE 1 STRESSING Factor for Prestressing Force 1.0


11. NO OF CABLES 25.58 25.58 25.58 25.58 25.58 25.58 25.58 25.58 25.58 25.58 25.58 25.58
12. HORIZ. PRESTR. FORCE (t) 8734.7 8770.1 9048.2 9086.3 9132.4 9166.8 9118.5 9067.6 8998.7 8923.9 8889.5 8848.5
13. CABLE C.G.(FROM BOTT.) (m) 1.473 1.473 1.402 1.321 1.237 1.080 0.971 0.867 0.770 0.673 0.576 0.577
14. ECC. OF CABLES (m) -0.517 -0.517 -0.588 -0.707 -0.791 -1.133 -1.242 -1.346 -1.443 -1.540 -1.637 -1.636
15. (1/a + Eb/z top ) 0.037 0.037 0.032 0.032 0.026 0.012 0.004 -0.003 -0.010 -0.018 -0.025 -0.025
16. (1/a - Eb/z bot ) 0.123 0.123 0.130 0.154 0.162 0.253 0.268 0.282 0.296 0.309 0.322 0.322

89
Ganga Bridge Between Arrah And Chapra P101010
Design of Box Girder Super Structure With Revised Dimensions of Segments (60m Span DN032RA

STRESS CHECK FOR BOX GIRDER

Sr. Section No. SEC#1 SEC#2 SEC#3 SEC#4 SEC#5 SEC#6 SEC#7 SEC#8 SEC#9 SEC#10 SEC#11 SEC#12
No
Distance from end support (m) 1.100 2.900 5.900 7.800 9.700 12.700 15.700 18.700 21.700 24.700 27.700 28.900
23 PRESTR STG1 CABLE- AFTER ES (t) 8555.1 8590.5 8868.6 8906.7 8952.8 8987.2 8938.9 8888.0 8819.2 8744.3 8709.9 8668.9
24 TOP STRESS (t/m 2 ) 319.5 320.9 287.9 282.1 231.4 112.1 39.6 -29.2 -92.5 -154.7 -216.1 -214.8
25 BOTTOM STRESS (t/m 2 ) 1050.5 1054.9 1150.2 1368.5 1452.7 2273.2 2395.0 2509.2 2608.3 2703.5 2808.5 2794.7
29 SIGMA (Top) (t/m 2 ) 380 474 579 656 676 689 701 699 686 657 611 614
30 SIGMA (Bottom) (t/m 2 ) 965 839 739 816 795 1199 1163 1151 1157 1191 1267 1250
STR @ C.G. OF STG1 BOT CABLE (t/m 2 ) 711.7 680.8 673.3 753.6 751.9 1036.7 1030.6 1035.9 1050.2 1085.1 1155.5 1142.3
AVG STR AT EACH SECTION (m) 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0
0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0
LENGTH (m) (m)
2
STR @ C.G.OF STG1 TOP CABLE (t/m ) 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0
AVG STR AT EACH SECTION (m) 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0

STRESS CHECK (IMMEDIATE LOSSES STAGE 1)


31 RELAXATION LOSS STG1 CABLE (t) 94.7 94.7 94.7 94.7 94.7 94.7 94.7 94.7 94.7 94.7 94.7 94.7
32 TOP STRESS (t/m 2 ) -3.5 -3.5 -3.1 -3.0 -2.4 -1.2 -0.4 0.3 1.0 1.7 2.3 2.3
33 BOTTOM STRESS (t/m 2 ) -11.6 -11.6 -12.3 -14.6 -15.4 -24.0 -25.4 -26.7 -28.0 -29.3 -30.5 -30.5
37 SIGMA ( Top ) (t/m 2 ) 376 471 576 653 674 687 700 700 687 659 613 616
38 SIGMA ( Bottom ) (t/m 2 ) 954 827 727 801 780 1175 1137 1124 1129 1161 1236 1220
STRESS CHECK AT 28 DAYS
53 SIGMA ( Top ) (t/m 2 ) 377 471 577 654 674 688 700 700 687 658 613 616
54 SIGMA ( Bottom ) (t/m 2 ) 956 829 729 804 783 1179 1142 1129 1134 1167 1242 1226

Stress Check ( After SIDL is laid )

55 SIDL MOMENT (tm) 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0
56 TOP STRESS (t/m 2 ) 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0
57 BOTTOM STRESS (t/m 2 ) 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0
58 SIGMA ( Top ) (t/m 2 ) 377 471 577 654 674 688 700 700 687 658 613 616
59 SIGMA ( Bottom ) (t/m 2 ) 956 829 729 804 783 1179 1142 1129 1134 1167 1242 1226

90
Ganga Bridge Between Arrah And Chapra P101010
Design of Box Girder Super Structure With Revised Dimensions of Segments (60m Span DN032RA

STRESS CHECK FOR BOX GIRDER

Sr. Section No. SEC#1 SEC#2 SEC#3 SEC#4 SEC#5 SEC#6 SEC#7 SEC#8 SEC#9 SEC#10 SEC#11 SEC#12
No
Distance from end support (m) 1.100 2.900 5.900 7.800 9.700 12.700 15.700 18.700 21.700 24.700 27.700 28.900

STRESS CHECK AT 90 DAYS


60 CREEP LOSS STG1 CABLE (t) 89.01 89.01 89.01 89.01 89.01 89.01 89.01 89.01 89.01 89.01 89.01 89.01
61 SHRINKAGE LOSS STG1 CABLE (t) 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
62 RELAXATION LOSS STG1 CABLE (t) 106.66 106.66 106.66 106.66 106.66 106.66 106.66 106.66 106.66 106.66 106.66 106.66
63 TOTAL LOSSES STG1 CABLE (t) 195.67 195.67 195.67 195.67 195.67 195.67 195.67 195.67 195.67 195.67 195.67 195.67
64 TOTAL WITH LONG TERM LOSSES (t) 195.67 195.67 195.67 195.67 195.67 195.67 195.67 195.67 195.67 195.67 195.67 195.67
65 TOP STRESS (t/m 2 ) -7.3 -7.3 -6.4 -6.2 -5.1 -2.4 -0.9 0.6 2.1 3.5 4.9 4.8
66 BOTTOM STRESS (t/m 2 ) -24.0 -24.0 -25.4 -30.1 -31.7 -49.5 -52.4 -55.2 -57.9 -60.5 -63.1 -63.1
67 SIGMA ( Top ) (t/m 2 ) 370 464 570 648 669 685 700 700 689 662 618 620
68 SIGMA ( Bottom ) (t/m 2 ) 932 805 704 774 751 1130 1090 1074 1076 1106 1179 1162

STRESS CHECK (AFTER SIDL)


69 SIDL MOMENT (tm) 198.0 505.5 972.2 1238.3 1481.4 1818.5 2098.6 2321.5 2487.2 2595.8 2647.2 2651.8
70 TOP STRESS (t/m 2 ) 13.6 34.6 66.6 86.2 103.1 134.7 155.5 172.0 184.3 192.3 196.1 196.4
2
71 BOTTOM STRESS (t/m ) -19.2 -48.9 -94.0 -127.4 -152.4 -251.2 -289.8 -320.6 -343.5 -358.5 -365.6 -366.2
72 SIGMA ( Top ) (t/m 2 ) 383 499 637 734 772 820 855 872 873 854 814 817
73 SIGMA ( Bottom ) (t/m 2 ) 913 757 610 646 599 879 800 754 733 748 813 796
STRESS CHECK (SERVICE CONDITION)
74 LL Positive MOMENT (tm) 227.9 561.5 1075.2 1344.7 1581.7 1885.5 2099.2 2236.7 2370.6 2443.3 2468.8 2462.3
Footpath liveload 20.9 53.3 102.6 130.7 156.3 191.9 221.4 244.9 262.4 273.9 279.3 279.8
75 TOP STRESS (t/m 2 ) 17.0 42.1 80.7 102.7 120.9 153.9 171.9 183.8 195.1 201.3 203.6 203.1
76 BOTTOM STRESS (t/m 2 ) -24.1 -59.5 -113.9 -151.8 -178.8 -286.9 -320.5 -342.7 -363.7 -375.3 -379.6 -378.7
77 SIGMA ( Top ) (t/m 2 ) 400 541 718 837 893 974 1027 1056 1068 1055 1017 1020
78 SIGMA ( Bottom ) (t/m 2 ) 889 697 496 494 420 592 479 411 369 373 434 418

91
Ganga Bridge Between Arrah And Chapra P101010
Design of Box Girder Super Structure With Revised Dimensions of Segments (60m Span DN032RA

STRESS CHECK FOR BOX GIRDER

Sr. Section No. SEC#1 SEC#2 SEC#3 SEC#4 SEC#5 SEC#6 SEC#7 SEC#8 SEC#9 SEC#10 SEC#11 SEC#12
No
Distance from end support (m) 1.100 2.900 5.900 7.800 9.700 12.700 15.700 18.700 21.700 24.700 27.700 28.900
LOSSES @ INFINITY DAYS
79 CREEP LOSS STG1 CABLE (t) 220.75 220.75 220.75 220.75 220.75 220.75 220.75 220.75 220.75 220.75 220.75 220.75
80 SHRINKAGE LOSS STG1 CABLE (t) 195.93 195.93 195.93 195.93 195.93 195.93 195.93 195.93 195.93 195.93 195.93 195.93
81 RELAXATION LOSS STG1 CABLE (t) 402.36 402.36 402.36 402.36 402.36 402.36 402.36 402.36 402.36 402.36 402.36 402.36
82 TOTAL LOSSES STG1 CABLE (t) 819.04 819.04 819.04 819.04 819.04 819.04 819.04 819.04 819.04 819.04 819.04 819.04
83 TOTAL WITH LONG TERM LOSSES (t) 819.0 819.0 819.0 819.0 819.0 819.0 819.0 819.0 819.0 819.0 819.0 819.0
84 TOP STRESS (t/m 2 ) -30.6 -30.6 -26.6 -25.9 -21.2 -10.2 -3.6 2.7 8.6 14.5 20.3 20.3
85 BOTTOM STRESS (t/m 2 ) -100.6 -100.6 -106.2 -125.8 -132.9 -207.2 -219.4 -231.2 -242.2 -253.2 -264.1 -264.0
STRESS CHECK (AT INFINITY WITHOUT LIVELOAD)
86 SIGMA ( Top ) (t/m 2 ) 352.8 467.9 610.2 707.9 751.1 809.6 851.4 874.8 881.9 868.5 834.1 837.0
87 SIGMA ( Bottom ) (t/m 2 ) 812.1 655.9 503.7 520.3 465.7 671.3 580.3 522.4 490.4 494.7 549.1 532.2
STRESS CHECK (AT INFINITY WITH LIVELOAD)
88 SIGMA ( Top ) (t/m 2 ) 370 510 691 811 872 964 1023 1059 1077 1070 1038 1040
89 SIGMA ( Bottom ) (t/m 2 ) 788 596 390 369 287 384 260 180 127 119 170 154

STRESS CHECK (RISE IN TEMP WITH 50% LIVELOAD)


90 50 % LL Positive Moment (tm) 113.9 280.8 537.6 672.4 790.9 942.7 1049.6 1118.3 1185.3 1221.6 1234.4 1231.2
91 Settlement Positive Moment (tm) 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0
92 Eigen stresses top (t/m 2 ) 715.3 715.3 715.3 715.3 715.3 715.3 715.3 715.3 715.3 715.3 715.3 432.4
93 Eigen stresses bottom (t/m 2 ) 82.3 82.3 82.3 82.3 82.3 82.3 82.3 82.3 82.3 82.3 82.3 130.8
94 SIGMA ( Top ) (t/m 2 ) 1075.9 1202.4 1362.3 1470.0 1521.4 1594.7 1644.5 1672.9 1685.0 1674.3 1640.8 1360.6
95 SIGMA ( Bottom ) (t/m 2 ) 883.4 711.0 534.0 533.4 466.7 623.4 517.6 450.2 409.0 408.3 460.9 493.0

STRESS CHECK (FALL IN TEMP WITH LIVELOAD)


96 Eigen stresses top (t/m 2 ) -344.6 -344.6 -341.2 -341.2 -341.2 -341.2 -341.2 -341.2 -341.2 -341.2 -341.2 -425.2
97 Eigen stresses bottom (t/m 2 ) 4.3 4.3 24.0 24.0 24.0 24.0 24.0 24.0 24.0 24.0 24.0 -17.4
98 SIGMA ( Top ) (t/m 2 ) 17 144 309 418 470 545 596 625 638 628 595 412
99 SIGMA ( Bottom ) (t/m 2 ) 1261 1009 776 791 700 991 844 752 699 705 790 515

92
Ganga Bridge Between Arrah And Chapra P101010
Design of Box Girder Super Structure With Revised Dimensions of Segments (60m Span DN032RA

ULTIMATE STRENGTH CHECK(MAXIMUM SHEAR CASE)-For 1 Lane ClassA

SR SECTION NO. UNITS SEC#2 SEC#3 SEC#4 SEC#5 SEC#6 SEC#7 SEC#8 SEC#9 SEC#10 SEC#11 SEC#12
NO
DISTANCE FROM END SUPPORT 2.900 5.900 7.800 9.700 12.700 15.700 18.700 21.700 24.700 27.700 28.900

DETAILS OF PRESTRESSING

1 HORIZ. PRESTR. FORCE - STG1 BOT (t) 8780.3 9053.1 9094.0 9139.6 9166.8 9118.5 9068.1 9003.0 8928.2 8893.7 8852.7
2 NO OF CABLES - STG1 BOT 25.58 25.58 25.58 25.58 25.58 25.58 25.58 25.58 25.58 25.58 25.58
3 CABLE C.G.(FROM BOTT.) (m) 1.475 1.401 1.323 1.243 1.088 0.976 0.869 0.769 0.672 0.576 0.577
4 VERT COMPONENT OF PRESTR. - STG1 BOT (t) 0.0 364.1 388.0 367.3 339.0 337.1 306.2 295.3 293.5 267.2 265.5
5 HORIZ. PRESTR. FORCE AFTER LOSSES - STG1 BOT (t) 7602.1 7875.0 7915.8 7961.4 7988.6 7940.3 7889.9 7824.8 7750.0 7715.5 7674.6
6 VERT PRESTR. FORCE AFTER LOSSES - STG1 BOT (t) 0.0 316.7 337.8 320.0 295.4 293.5 266.4 256.6 254.8 231.8 230.2
13 TOTAL HORIZ. PRESTR. FORCE AFTER LOSSES (t) 7602.1 7875.0 7915.8 7961.4 7988.6 7940.3 7889.9 7824.8 7750.0 7715.5 7674.6
14 TOTAL VERT COMPONENT OF PRESTR. AFTER LOSSES (t) 0.0 316.7 337.8 320.0 295.4 293.5 266.4 256.6 254.8 231.8 230.2
15 TOTAL NO OF CABLES 25.6 25.6 25.6 25.6 25.6 25.6 25.6 25.6 25.6 25.6 25.6
16 NET ECC FROM BOTTOM (m) 1.475 1.401 1.323 1.243 1.088 0.976 0.869 0.769 0.672 0.576 0.577

SECTION PROPERTIES

35 SOFFIT WIDTH (m) 6.900 6.900 6.900 6.900 6.900 6.900 6.900 6.900 6.900 6.900 6.900
36 DECK WIDTH (m) 20.500 20.500 20.500 20.500 20.500 20.500 20.500 20.500 20.500 20.500 20.500
17 WIDTH AT TOP OF CELL (m) 12.700 12.700 12.700 12.700 12.700 12.700 12.700 12.700 12.700 12.700 12.700
18 EFF WIDTH OF COMPR FLANGE (m) 20.500 20.500 20.500 20.500 20.500 20.500 20.500 20.500 20.500 20.500 20.500
19 WIDTH OF WEB BW (m) 0.610 0.460 0.460 0.460 0.310 0.310 0.310 0.310 0.310 0.310 0.310
20 NO OF WEB 2 2 2 2 2 2 2 2 2 2 2
21 DUCT DIA DDUCT m 0.110 0.110 0.110 0.110 0.110 0.110 0.110 0.110 0.110 0.110 0.110
22 EFFECTIVE WIDTHOF WEB (BW-0.5*DDUCT) m 1.110 0.810 0.810 0.810 0.510 0.510 0.510 0.510 0.510 0.510 0.510
23 DECK SLAB THICKNESS m 0.230 0.230 0.230 0.230 0.230 0.230 0.230 0.230 0.230 0.230 0.230
24 SOFFIT SLAB THICKNESS m 0.400 0.400 0.400 0.400 0.260 0.260 0.260 0.260 0.260 0.260 0.260
23 DEP OF COMPRESSION FLANGE m 0.230 0.230 0.230 0.230 0.230 0.230 0.230 0.230 0.230 0.230 0.230
24 Db m 2.720 2.720 2.720 2.720 2.720 2.720 2.720 2.720 2.728 2.824 2.823
25 TOTAL DEPTH OF BOX SECTION FOR SHEAR (m) 3.400 3.400 3.400 3.400 3.400 3.400 3.400 3.400 3.400 3.400 3.400
26 AREA OF BOX SECTION (m2) 13.739 13.739 12.362 12.362 10.371 10.371 10.371 10.371 10.371 10.371 10.371
27 C.G. OF BOX SECTION FROM BOTTOM (m) 1.990 1.990 2.028 2.028 2.213 2.213 2.213 2.213 2.213 2.213 2.213
28 MOMENT OF INERTIA OF BOX SECTION (m4) 20.576 20.576 19.716 19.716 16.023 16.023 16.023 16.023 16.023 16.023 16.023
29 AY BOX SECTION (m3) 10.340 10.340 9.722 9.722 7.240 7.240 7.240 7.240 7.240 7.240 7.240
30 AREA ENCL C/I OF BOX (Ak) (m2) 29.292 29.523 29.523 29.523 30.430 30.430 30.430 30.430 30.430 30.430 30.430
31 PERIMETER OF Ak (m) 25.160 25.310 25.310 25.310 25.600 25.600 25.600 25.600 25.600 25.600 25.600
S= First Moment of Inertia (m3) 5.310 5.310 5.310 5.310 5.310 5.310 5.310 5.310 5.310 5.310 5.310
32 FCK (Mpa) 45 45 45 45 45 45 45 45 45 45 45

93
Ganga Bridge Between Arrah And Chapra P101010
Design of Box Girder Super Structure With Revised Dimensions of Segments (60m Span DN032RA

ULTIMATE STRENGTH CHECK(MAXIMUM SHEAR CASE)-For 1 Lane ClassA

SR SECTION NO. UNITS SEC#2 SEC#3 SEC#4 SEC#5 SEC#6 SEC#7 SEC#8 SEC#9 SEC#10 SEC#11 SEC#12
NO
DISTANCE FROM END SUPPORT 2.900 5.900 7.800 9.700 12.700 15.700 18.700 21.700 24.700 27.700 28.900

ULTIMATE SHEAR AND CORR. MOMENT


0 Shear Forces

33 DUE TO DL (t) 801.8 694.6 629.9 565.3 470.7 383.5 296.3 209.2 122.0 34.9 0.0
55 DUE TO STAGE 2 DL (t) 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0
34 DUE TO S.I.D.L. (t) 83.9 74.2 68.0 61.9 52.2 42.6 32.9 23.2 13.5 3.9 0.0
35 DUE TO LIVE LOAD (t) 60.6 53.9 50.6 46.8 41.0 36.3 32.8 29.2 26.2 22.7 52.3
36 DUE TO FOOTPATH LIVE LOAD (t) 17.5 15.6 14.5 13.4 11.8 10.3 8.9 7.6 6.4 5.3 12.0
36 DUE TO HYPERSTATIC REACTIONS IMM (t) 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0

TOTAL SHEAR (t) 1340.2 1166.3 1062.1 957.1 801.9 658.5 516.9 375.6 235.0 93.9 160.8
37

Bending Moments

38 DUE TO STAGE1 DL (tm) 2482.7 4727.4 5985.7 7121.1 8675.0 9956.2 10975.9 11734.2 12231.0 12466.3 12487.3
66 DUE TO STAGE 2 DL (tm) 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0
39 DUE TO S.I.D.L. (tm) 256.7 493.8 628.9 752.3 923.6 1065.8 1179.0 1263.2 1318.3 1344.5 1346.8
40 DUE TO CREEP REDISTRIBUTION OF DL (tm) 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0
40 DUE TO LIVE LOAD (tm) 175.7 333.6 420.6 491.9 578.4 645.2 612.6 634.6 646.6 628.1 1574.3
41 DUE TO FOOTPATH LIVE LOAD (tm) 50.7 92.1 113.0 130.1 149.7 161.3 165.7 163.9 156.8 145.5 4.4
41 HYP IMM (tm) 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0
42 HYP INF (tm) 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0
43 DUE TO HYPERSTATIC REACTIONS (tm) 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0
44 DUE TO CREEP REDISTRIBUTION OF PRESTRESS (tm) 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0
45 DUE TO DIFFERENTIAL SETTLEMENT (tm) 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0
46 DESIGN MOMENT (tm) 4123 7852 9942 11818 14367 16459 17990 19192 19969 20292 21583
42 ULTIMATE DESIGN MOMENT (tm) 4123 7852 9942 11818 14367 16459 17990 19192 19969 20292 21583
533 262 192 72 28 -151 -259 -336 -362 -314 -615
Fctk0.05/1.5 -156 -156 -156 -156 -156 -156 -156 -156 -156 -156 156

94
Ganga Bridge Between Arrah And Chapra P101010
Design of Box Girder Super Structure With Revised Dimensions of Segments (60m Span DN032RA

ULTIMATE STRENGTH CHECK(MAXIMUM SHEAR CASE)-For 1 Lane ClassA

SR SECTION NO. UNITS SEC#2 SEC#3 SEC#4 SEC#5 SEC#6 SEC#7 SEC#8 SEC#9 SEC#10 SEC#11 SEC#12
NO
DISTANCE FROM END SUPPORT 2.900 5.900 7.800 9.700 12.700 15.700 18.700 21.700 24.700 27.700 28.900

Shear capacity of the uncracked section

60 Design value of Concrete tensile strength(f ctd = f ct / g m ) (t/m2) 170.0 170.0 170.0 170.0 170.0 170.0 170.0 170.0 170.0 170.0 161.0

61 k1 = 1 for prestressed concrete 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0

61 s cp = Mean Compressive strength (t/m2) 553.3 573.2 640.3 644.0 770.3 765.6 760.8 754.5 747.3 744.0 740.0
FCD (t/m2) 2050.2 2050.2 2050.2 2050.2 2050.2 2050.2 2050.2 2050.2 2050.2 2050.2 2050.2
UNCRACKED SHEAR CAPACITY OF THE SECTION
2 1508.3 1115.6 1116.3 1118.8 615.3 613.8 612.2 610.1 607.7 606.6 404.5
(I * Bw /S * (SQRT (fctd2+ k1* s cp *f ctd )) (t/m )
62
1.25 1.25 1.25 1.25 1.25 1.25 1.25 1.25 1.25 1.25 1.25
Shear capacity of the cracked section

63 K =(1+sqrt(200/d)),d is in mm. (m) 1.271 1.271 1.271 1.271 1.271 1.271 1.271 1.271 1.271 1.266 2.823

64 r 1 = Min(A sl /b w /d,.02) (m) 0.020 0.020 0.020 0.020 0.020 0.020 0.020 0.020 0.020 0.020 2.213

(t/m2) 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 2474.4
3/2 (1/2)
65 Vmin = 0.031K f ck
66 V Rd,c 1 (tm) 443.0 329.8 352.0 353.2 248.6 247.7 246.7 245.4 244.5 252.1 16129.8

67 V Rd,c 2 =(V min +.15* s cp )b w *d t 342.2 256.2 278.4 279.6 202.3 201.4 200.3 199.0 198.1 204.1 116.3

68 SHEAR CAPACITY OF THE CRACKED SECTION (VCR) (t) 443 330 352 353 249 248 247 245 245 252 155.9

Check for Shear capacity & Shear Reinf. Calculations

69 SHEAR CAPACITY OF THE CONCRETE SECTION (t) 1508.3 1115.6 1116.3 1118.8 615.3 613.8 246.7 245.4 244.5 252.1 155.9

70 CRACKED OR UNCRACKED un cr un cr un cr un cr un cr un cr cr cr cr cr cr

71 V -Vp(ULTIMATE) (CALCULATED ABOVE) (t) 1340.2 849.6 724.4 637.1 506.4 365.0 250.5 118.9 0.0 0.0 0.0

73 MAX ALLOWABLE SHEAR STRESS ( FOR M 50 GRADE ) T/m2 487 487 487 487 487 487 487 487 487 487 487

75 Ved =(V-Vp) (t) 1340.2 849.6 724.4 637.1 506.4 365.0 250.5 118.9 0.0 0.0 0.0

a cw = 1.3 1.3 1.3 1.3 1.3 1.3 1.3 1.3 1.3 1.3 1.3
V Rd,max /(COT(THETA)+TAN(THETA)) (t) 3285.9 2489.4 2586.6 2686.9 1813.5 1900.9 1985.0 2062.9 2139.1 2214.4 2214.1

Theta( q ) 27.4 22.5 22.5 22.5 22.5 22.5 22.5 22.5 22.5 22.5 22.5
V Rd,max (t) 1341.8 880.2 914.5 950.0 641.2 672.1 701.8 729.3 756.3 782.9 782.8
OK OK OK OK OK OK OK OK OK OK OK

76 ASV/SV (TOTAL) (cm2/m) 11.78 8.89 8.89 8.89 5.99 5.99 11.78 5.99 5.99 5.99 5.99

78 ASV/SV PER WEB (cm2/m) 5.89 4.44 4.44 4.44 2.99 2.99 5.89 2.99 2.99 2.99 2.99

95
Ganga Bridge Between Arrah And Chapra P101010
Design of Box Girder Super Structure With Revised Dimensions of Segments (60m Span DN032RA

ULTIMATE STRENGTH CHECK(MAXIMUM SHEAR CASE)-For 2 Lane ClassA

SR SECTION NO. UNITS SEC#2 SEC#3 SEC#4 SEC#5 SEC#6 SEC#7 SEC#8 SEC#9 SEC#10 SEC#11 SEC#12
NO
DISTANCE FROM END SUPPORT 2.900 5.900 7.800 9.700 12.700 15.700 18.700 21.700 24.700 27.700 28.900

DETAILS OF PRESTRESSING

1 HORIZ. PRESTR. FORCE - STG1 BOT (t) 8780.3 9053.1 9094.0 9139.6 9166.8 9118.5 9068.1 9003.0 8928.2 8893.7 8852.7
2 NO OF CABLES - STG1 BOT 25.58 25.58 25.58 25.58 25.58 25.58 25.58 25.58 25.58 25.58 25.58
3 CABLE C.G.(FROM BOTT.) (m) 1.475 1.401 1.323 1.243 1.088 0.976 0.869 0.769 0.672 0.576 0.577
4 VERT COMPONENT OF PRESTR. - STG1 BOT (t) 0.0 364.1 388.0 367.3 339.0 337.1 306.2 295.3 293.5 267.2 265.5
5 HORIZ. PRESTR. FORCE AFTER LOSSES - STG1 BOT (t) 7602.1 7875.0 7915.8 7961.4 7988.6 7940.3 7889.9 7824.8 7750.0 7715.5 7674.6
6 VERT PRESTR. FORCE AFTER LOSSES - STG1 BOT (t) 0.0 316.7 337.8 320.0 295.4 293.5 266.4 256.6 254.8 231.8 230.2
13 TOTAL HORIZ. PRESTR. FORCE AFTER LOSSES (t) 7602.1 7875.0 7915.8 7961.4 7988.6 7940.3 7889.9 7824.8 7750.0 7715.5 7674.6
14 TOTAL VERT COMPONENT OF PRESTR. AFTER LOSSES (t) 0.0 316.7 337.8 320.0 295.4 293.5 266.4 256.6 254.8 231.8 230.2
15 TOTAL NO OF CABLES 25.6 25.6 25.6 25.6 25.6 25.6 25.6 25.6 25.6 25.6 25.6
16 NET ECC FROM BOTTOM (m) 1.475 1.401 1.323 1.243 1.088 0.976 0.869 0.769 0.672 0.576 0.577

SECTION PROPERTIES

35 SOFFIT WIDTH (m) 6.900 6.900 6.900 6.900 6.900 6.900 6.900 6.900 6.900 6.900 6.900
36 DECK WIDTH (m) 20.500 20.500 20.500 20.500 20.500 20.500 20.500 20.500 20.500 20.500 20.500
17 WIDTH AT TOP OF CELL (m) 12.700 12.700 12.700 12.700 12.700 12.700 12.700 12.700 12.700 12.700 12.700
18 EFF WIDTH OF COMPR FLANGE (m) 20.500 20.500 20.500 20.500 20.500 20.500 20.500 20.500 20.500 20.500 20.500
19 WIDTH OF WEB BW (m) 0.610 0.460 0.460 0.460 0.310 0.310 0.310 0.310 0.310 0.310 0.310
20 NO OF WEB 2 2 2 2 2 2 2 2 2 2 2
21 DUCT DIA DDUCT m 0.110 0.110 0.110 0.110 0.110 0.110 0.110 0.110 0.110 0.110 0.110
22 EFFECTIVE WIDTHOF WEB (BW-0.5*DDUCT) m 1.110 0.810 0.810 0.810 0.510 0.510 0.510 0.510 0.510 0.510 0.510
23 DECK SLAB THICKNESS m 0.230 0.230 0.230 0.230 0.230 0.230 0.230 0.230 0.230 0.230 0.230
24 SOFFIT SLAB THICKNESS m 0.400 0.400 0.400 0.400 0.260 0.260 0.260 0.260 0.260 0.260 0.260
23 DEP OF COMPRESSION FLANGE m 0.230 0.230 0.230 0.230 0.230 0.230 0.230 0.230 0.230 0.230 0.230
24 Db m 2.720 2.720 2.720 2.720 2.720 2.720 2.720 2.720 2.728 2.824 2.823
25 TOTAL DEPTH OF BOX SECTION FOR SHEAR (m) 3.400 3.400 3.400 3.400 3.400 3.400 3.400 3.400 3.400 3.400 3.400
26 AREA OF BOX SECTION (m2) 13.739 13.739 12.362 12.362 10.371 10.371 10.371 10.371 10.371 10.371 10.371
27 C.G. OF BOX SECTION FROM BOTTOM (m) 1.990 1.990 2.028 2.028 2.213 2.213 2.213 2.213 2.213 2.213 2.213
28 MOMENT OF INERTIA OF BOX SECTION (m4) 20.576 20.576 19.716 19.716 16.023 16.023 16.023 16.023 16.023 16.023 16.023
29 AY BOX SECTION (m3) 10.340 10.340 9.722 9.722 7.240 7.240 7.240 7.240 7.240 7.240 7.240
30 AREA ENCL C/I OF BOX (Ak) (m2) 29.292 29.523 29.523 29.523 30.430 30.430 30.430 30.430 30.430 30.430 30.430
31 PERIMETER OF Ak (m) 25.160 25.310 25.310 25.310 25.600 25.600 25.600 25.600 25.600 25.600 25.600
S= First Moment of Inertia (m3) 5.310 5.310 5.310 5.310 5.310 5.310 5.310 5.310 5.310 5.310 5.310
32 FCK (Mpa) 45 45 45 45 45 45 45 45 45 45 45

97
Ganga Bridge Between Arrah And Chapra P101010
Design of Box Girder Super Structure With Revised Dimensions of Segments (60m Span DN032RA

ULTIMATE STRENGTH CHECK(MAXIMUM SHEAR CASE)-For 2 Lane ClassA

SR SECTION NO. UNITS SEC#2 SEC#3 SEC#4 SEC#5 SEC#6 SEC#7 SEC#8 SEC#9 SEC#10 SEC#11 SEC#12
NO
DISTANCE FROM END SUPPORT 2.900 5.900 7.800 9.700 12.700 15.700 18.700 21.700 24.700 27.700 28.900

ULTIMATE SHEAR AND CORR. MOMENT


0 Shear Forces

33 DUE TO DL (t) 801.8 694.6 629.9 565.3 470.7 383.5 296.3 209.2 122.0 34.9 0.0
55 DUE TO STAGE 2 DL (t) 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0
34 DUE TO S.I.D.L. (t) 83.9 74.2 68.0 61.9 52.2 42.6 32.9 23.2 13.5 3.9 0.0
35 DUE TO LIVE LOAD (t) 121.1 107.8 101.3 93.6 82.0 72.6 65.5 58.5 52.4 45.4 38.7
36 DUE TO FOOTPATH LIVE LOAD (t) 17.5 15.6 14.5 13.4 11.8 10.3 8.9 7.6 6.4 5.3 4.4
36 DUE TO HYPERSTATIC REACTIONS IMM (t) 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0

TOTAL SHEAR (t) 1431.0 1247.1 1138.1 1027.3 863.4 713.0 566.1 419.4 274.3 127.9 63.2
37

Bending Moments

38 DUE TO STAGE1 DL (tm) 2482.7 4727.4 5985.7 7121.1 8675.0 9956.2 10975.9 11734.2 12231.0 12466.3 12487.3
66 DUE TO STAGE 2 DL (tm) 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0
39 DUE TO S.I.D.L. (tm) 256.7 493.8 628.9 752.3 923.6 1065.8 1179.0 1263.2 1318.3 1344.5 1346.8
40 DUE TO CREEP REDISTRIBUTION OF DL (tm) 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0
40 DUE TO LIVE LOAD (tm) 351.3 667.2 841.2 983.8 1156.8 1290.4 1225.2 1269.2 1293.3 1256.2 1166.1
41 DUE TO FOOTPATH LIVE LOAD (tm) 50.7 92.1 113.0 130.1 149.7 161.3 165.7 163.9 156.8 145.5 151.3
41 HYP IMM (tm) 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0
42 HYP INF (tm) 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0
43 DUE TO HYPERSTATIC REACTIONS (tm) 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0
44 DUE TO CREEP REDISTRIBUTION OF PRESTRESS (tm) 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0
45 DUE TO DIFFERENTIAL SETTLEMENT (tm) 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0
46 DESIGN MOMENT (tm) 4386 8353 10573 12555 15235 17427 18909 20144 20939 21234 21138
42 ULTIMATE DESIGN MOMENT (tm) 4386 8353 10573 12555 15235 17427 18909 20144 20939 21234 21138
508 214 127 -4 -92 -285 -386 -468 -496 -445 -445
Fctk0.05/1.5 -156 -156 -156 -156 -156 -156 -156 -156 -156 -156 -156

98
Ganga Bridge Between Arrah And Chapra P101010
Design of Box Girder Super Structure With Revised Dimensions of Segments (60m Span DN032RA

ULTIMATE STRENGTH CHECK(MAXIMUM SHEAR CASE)-For 2 Lane ClassA

SR SECTION NO. UNITS SEC#2 SEC#3 SEC#4 SEC#5 SEC#6 SEC#7 SEC#8 SEC#9 SEC#10 SEC#11 SEC#12
NO
DISTANCE FROM END SUPPORT 2.900 5.900 7.800 9.700 12.700 15.700 18.700 21.700 24.700 27.700 28.900

Shear capacity of the uncracked section

60 Design value of Concrete tensile strength(f ctd = f ct / g m ) (t/m2) 170.0 170.0 170.0 170.0 170.0 170.0 170.0 170.0 170.0 170.0 170.0

61 k1 = 1 for prestressed concrete 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0

61 s cp = Mean Compressive strength (t/m2) 553.3 573.2 640.3 644.0 770.3 765.6 760.8 754.5 747.3 744.0 740.0
FCD (t/m2) 2050.2 2050.2 2050.2 2050.2 2050.2 2050.2 2050.2 2050.2 2050.2 2050.2 2050.2
UNCRACKED SHEAR CAPACITY OF THE SECTION
2 1508.3 1115.6 1116.3 1118.8 615.3 613.8 612.2 610.1 607.7 606.6 605.3
(I * Bw /S * (SQRT (fctd2+ k1* s cp *f ctd )) (t/m )
62
1.25 1.25 1.25 1.25 1.25 1.25 1.25 1.25 1.25 1.25 1.25
Shear capacity of the cracked section

63 K =(1+sqrt(200/d)),d is in mm. (m) 1.271 1.271 1.271 1.271 1.271 1.271 1.271 1.271 1.271 1.266 1.266

64 r 1 = Min(A sl /b w /d,.02) (m) 0.020 0.020 0.020 0.020 0.020 0.020 0.020 0.020 0.020 0.020 0.020

(t/m2) 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3
3/2 (1/2)
65 Vmin = 0.031K f ck
66 V Rd,c 1 (tm) 443.0 329.8 352.0 353.2 248.6 247.7 246.7 245.4 244.5 252.1 251.2

67 V Rd,c 2 =(V min +.15* s cp )b w *d t 342.2 256.2 278.4 279.6 202.3 201.4 200.3 199.0 198.1 204.1 203.2

68 SHEAR CAPACITY OF THE CRACKED SECTION (VCR) (t) 443 330 352 353 249 248 247 245 245 252 251

Check for Shear capacity & Shear Reinf. Calculations

69 SHEAR CAPACITY OF THE CONCRETE SECTION (t) 1508.3 1115.6 1116.3 1118.8 615.3 247.7 246.7 245.4 244.5 252.1 251.2

70 CRACKED OR UNCRACKED un cr un cr un cr un cr un cr cr cr cr cr cr cr

71 V -Vp(ULTIMATE) (CALCULATED ABOVE) (t) 1431.0 930.4 800.3 707.3 567.9 419.5 299.7 162.8 19.5 0.0 0.0

73 MAX ALLOWABLE SHEAR STRESS ( FOR M 50 GRADE ) T/m2 487 487 487 487 487 487 487 487 487 487 487

75 Ved =(V-Vp) (t) 1431.0 930.4 800.3 707.3 567.9 419.5 299.7 162.8 19.5 0.0 0.0

a cw = 1.3 1.3 1.3 1.3 1.3 1.3 1.3 1.3 1.3 1.3 1.3
V Rd,max /(COT(THETA)+TAN(THETA)) (t) 3285.9 2489.4 2586.6 2686.9 1813.5 1900.9 1985.0 2062.9 2139.1 2214.4 2214.1

Theta( q ) 30.3 24.2 22.5 22.5 22.5 22.5 22.5 22.5 22.5 22.5 22.5
V Rd,max (t) 1432.4 931.9 914.5 950.0 641.2 672.1 701.8 729.3 756.3 782.9 782.8
OK OK OK OK OK OK OK OK OK OK OK

76 ASV/SV (TOTAL) (cm2/m) 11.78 8.89 8.89 8.89 5.99 20.60 14.09 5.99 5.99 5.99 5.99

78 ASV/SV PER WEB (cm2/m) 5.89 4.44 4.44 4.44 2.99 10.30 7.05 2.99 2.99 2.99 2.99

99
Ganga Bridge Between Arrah And Chapra P101010
Design of Box Girder Super Structure With Revised Dimensions of Segments (60m Span DN032RA

ULTIMATE STRENGTH CHECK(MAXIMUM SHEAR CASE)-For 1 Lane 70R

SR SECTION NO. UNITS SEC#2 SEC#3 SEC#4 SEC#5 SEC#6 SEC#7 SEC#8 SEC#9 SEC#10 SEC#11 SEC#12
NO
DISTANCE FROM END SUPPORT 2.900 5.900 7.800 9.700 12.700 15.700 18.700 21.700 24.700 27.700 28.900

DETAILS OF PRESTRESSING

1 HORIZ. PRESTR. FORCE - STG1 BOT (t) 8780.3 9053.1 9094.0 9139.6 9166.8 9118.5 9068.1 9003.0 8928.2 8893.7 8852.7
2 NO OF CABLES - STG1 BOT 25.58 25.58 25.58 25.58 25.58 25.58 25.58 25.58 25.58 25.58 25.58
3 CABLE C.G.(FROM BOTT.) (m) 1.475 1.401 1.323 1.243 1.088 0.976 0.869 0.769 0.672 0.576 0.577
4 VERT COMPONENT OF PRESTR. - STG1 BOT (t) 0.0 364.1 388.0 367.3 339.0 337.1 306.2 295.3 293.5 267.2 265.5
5 HORIZ. PRESTR. FORCE AFTER LOSSES - STG1 BOT (t) 7602.1 7875.0 7915.8 7961.4 7988.6 7940.3 7889.9 7824.8 7750.0 7715.5 7674.6
6 VERT PRESTR. FORCE AFTER LOSSES - STG1 BOT (t) 0.0 316.7 337.8 320.0 295.4 293.5 266.4 256.6 254.8 231.8 230.2
13 TOTAL HORIZ. PRESTR. FORCE AFTER LOSSES (t) 7602.1 7875.0 7915.8 7961.4 7988.6 7940.3 7889.9 7824.8 7750.0 7715.5 7674.6
14 TOTAL VERT COMPONENT OF PRESTR. AFTER LOSSES (t) 0.0 316.7 337.8 320.0 295.4 293.5 266.4 256.6 254.8 231.8 230.2
15 TOTAL NO OF CABLES 25.6 25.6 25.6 25.6 25.6 25.6 25.6 25.6 25.6 25.6 25.6
16 NET ECC FROM BOTTOM (m) 1.475 1.401 1.323 1.243 1.088 0.976 0.869 0.769 0.672 0.576 0.577

SECTION PROPERTIES

35 SOFFIT WIDTH (m) 6.900 6.900 6.900 6.900 6.900 6.900 6.900 6.900 6.900 6.900 6.900
36 DECK WIDTH (m) 20.500 20.500 20.500 20.500 20.500 20.500 20.500 20.500 20.500 20.500 20.500
17 WIDTH AT TOP OF CELL (m) 12.700 12.700 12.700 12.700 12.700 12.700 12.700 12.700 12.700 12.700 12.700
18 EFF WIDTH OF COMPR FLANGE (m) 20.500 20.500 20.500 20.500 20.500 20.500 20.500 20.500 20.500 20.500 20.500
19 WIDTH OF WEB BW (m) 0.610 0.460 0.460 0.460 0.310 0.310 0.310 0.310 0.310 0.310 0.310
20 NO OF WEB 2 2 2 2 2 2 2 2 2 2 2
21 DUCT DIA DDUCT m 0.110 0.110 0.110 0.110 0.110 0.110 0.110 0.110 0.110 0.110 0.110
22 EFFECTIVE WIDTHOF WEB (BW-0.5*DDUCT) m 1.110 0.810 0.810 0.810 0.510 0.510 0.510 0.510 0.510 0.510 0.510
23 DECK SLAB THICKNESS m 0.230 0.230 0.230 0.230 0.230 0.230 0.230 0.230 0.230 0.230 0.230
24 SOFFIT SLAB THICKNESS m 0.400 0.400 0.400 0.400 0.260 0.260 0.260 0.260 0.260 0.260 0.260
23 DEP OF COMPRESSION FLANGE m 0.230 0.230 0.230 0.230 0.230 0.230 0.230 0.230 0.230 0.230 0.230
24 Db m 2.720 2.720 2.720 2.720 2.720 2.720 2.720 2.720 2.728 2.824 2.823
25 TOTAL DEPTH OF BOX SECTION FOR SHEAR (m) 3.400 3.400 3.400 3.400 3.400 3.400 3.400 3.400 3.400 3.400 3.400
26 AREA OF BOX SECTION (m2) 13.739 13.739 12.362 12.362 10.371 10.371 10.371 10.371 10.371 10.371 10.371
27 C.G. OF BOX SECTION FROM BOTTOM (m) 1.990 1.990 2.028 2.028 2.213 2.213 2.213 2.213 2.213 2.213 2.213
28 MOMENT OF INERTIA OF BOX SECTION (m4) 20.576 20.576 19.716 19.716 16.023 16.023 16.023 16.023 16.023 16.023 16.023
29 AY BOX SECTION (m3) 10.340 10.340 9.722 9.722 7.240 7.240 7.240 7.240 7.240 7.240 7.240
30 AREA ENCL C/I OF BOX (Ak) (m2) 29.292 29.523 29.523 29.523 30.430 30.430 30.430 30.430 30.430 30.430 30.430
31 PERIMETER OF Ak (m) 25.160 25.310 25.310 25.310 25.600 25.600 25.600 25.600 25.600 25.600 25.600
S= First Moment of Inertia (m3) 5.310 5.310 5.310 5.310 5.310 5.310 5.310 5.310 5.310 5.310 5.310
32 FCK (Mpa) 45 45 45 45 45 45 45 45 45 45 45

101
Ganga Bridge Between Arrah And Chapra P101010
Design of Box Girder Super Structure With Revised Dimensions of Segments (60m Span DN032RA

ULTIMATE STRENGTH CHECK(MAXIMUM SHEAR CASE)-For 1 Lane 70R

SR SECTION NO. UNITS SEC#2 SEC#3 SEC#4 SEC#5 SEC#6 SEC#7 SEC#8 SEC#9 SEC#10 SEC#11 SEC#12
NO
DISTANCE FROM END SUPPORT 2.900 5.900 7.800 9.700 12.700 15.700 18.700 21.700 24.700 27.700 28.900

ULTIMATE SHEAR AND CORR. MOMENT


0 Shear Forces

33 DUE TO DL (t) 801.8 694.6 629.9 565.3 470.7 383.5 296.3 209.2 122.0 34.9 0.0
55 DUE TO STAGE 2 DL (t) 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0
34 DUE TO S.I.D.L. (t) 83.9 74.2 68.0 61.9 52.2 42.6 32.9 23.2 13.5 3.9 0.0
35 DUE TO LIVE LOAD (t) 111.3 99.4 92.1 87.2 78.8 72.9 66.6 61.0 54.7 49.2 52.3
36 DUE TO FOOTPATH LIVE LOAD (t) 17.5 15.6 14.5 13.4 11.8 10.3 8.9 7.6 6.4 5.3 12.0
36 DUE TO HYPERSTATIC REACTIONS IMM (t) 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0

TOTAL SHEAR (t) 1416.2 1234.5 1124.3 1017.8 858.6 713.4 567.6 423.3 277.8 133.6 160.8
37

Bending Moments

38 DUE TO STAGE1 DL (tm) 2482.7 4727.4 5985.7 7121.1 8675.0 9956.2 10975.9 11734.2 12231.0 12466.3 12487.3
66 DUE TO STAGE 2 DL (tm) 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0
39 DUE TO S.I.D.L. (tm) 256.7 493.8 628.9 752.3 923.6 1065.8 1179.0 1263.2 1318.3 1344.5 1346.8
40 DUE TO CREEP REDISTRIBUTION OF DL (tm) 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0
40 DUE TO LIVE LOAD (tm) 322.7 586.3 718.2 846.2 1001.0 1144.3 1244.7 1324.3 1351.1 1361.9 1574.3
41 DUE TO FOOTPATH LIVE LOAD (tm) 50.7 92.1 113.0 130.1 149.7 161.3 165.7 163.9 156.8 145.5 4.4
41 HYP IMM (tm) 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0
42 HYP INF (tm) 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0
43 DUE TO HYPERSTATIC REACTIONS (tm) 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0
44 DUE TO CREEP REDISTRIBUTION OF PRESTRESS (tm) 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0
45 DUE TO DIFFERENTIAL SETTLEMENT (tm) 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0
46 DESIGN MOMENT (tm) 4343 8231 10388 12349 15001 17208 18938 20227 21026 21393 21583
42 ULTIMATE DESIGN MOMENT (tm) 4343 8231 10388 12349 15001 17208 18938 20227 21026 21393 21583
512 225 146 17 -60 -254 -390 -479 -508 -466 -615
Fctk0.05/1.5 -156 -156 -156 -156 -156 -156 -156 -156 -156 -156 156

102
Ganga Bridge Between Arrah And Chapra P101010
Design of Box Girder Super Structure With Revised Dimensions of Segments (60m Span DN032RA

ULTIMATE STRENGTH CHECK(MAXIMUM SHEAR CASE)-For 1 Lane 70R

SR SECTION NO. UNITS SEC#2 SEC#3 SEC#4 SEC#5 SEC#6 SEC#7 SEC#8 SEC#9 SEC#10 SEC#11 SEC#12
NO
DISTANCE FROM END SUPPORT 2.900 5.900 7.800 9.700 12.700 15.700 18.700 21.700 24.700 27.700 28.900

Shear capacity of the uncracked section

60 Design value of Concrete tensile strength(f ctd = f ct / g m ) (t/m2) 170.0 170.0 170.0 170.0 170.0 170.0 170.0 170.0 170.0 170.0 170.0

61 k1 = 1 for prestressed concrete 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0

61 s cp = Mean Compressive strength (t/m2) 553.3 573.2 640.3 644.0 770.3 765.6 760.8 754.5 747.3 744.0 740.0
FCD (t/m2) 2050.2 2050.2 2050.2 2050.2 2050.2 2050.2 2050.2 2050.2 2050.2 2050.2 2050.2
UNCRACKED SHEAR CAPACITY OF THE SECTION
2 1508.3 1115.6 1116.3 1118.8 615.3 613.8 612.2 610.1 607.7 606.6 605.3
(I * Bw /S * (SQRT (fctd2+ k1* s cp *f ctd )) (t/m )
62
1.25 1.25 1.25 1.25 1.25 1.25 1.25 1.25 1.25 1.25 1.25
Shear capacity of the cracked section

63 K =(1+sqrt(200/d)),d is in mm. (m) 1.271 1.271 1.271 1.271 1.271 1.271 1.271 1.271 1.271 1.266 2.823

64 r 1 = Min(A sl /b w /d,.02) (m) 0.020 0.020 0.020 0.020 0.020 0.020 0.020 0.020 0.020 0.020 2.213

(t/m2) 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 2474.4
3/2 (1/2)
65 Vmin = 0.031K f ck
66 V Rd,c 1 (tm) 443.0 329.8 352.0 353.2 248.6 247.7 246.7 245.4 244.5 252.1 16129.8

67 V Rd,c 2 =(V min +.15* s cp )b w *d t 342.2 256.2 278.4 279.6 202.3 201.4 200.3 199.0 198.1 204.1 116.3

68 SHEAR CAPACITY OF THE CRACKED SECTION (VCR) (t) 443 330 352 353 249 248 247 245 245 252 155.9

Check for Shear capacity & Shear Reinf. Calculations

69 SHEAR CAPACITY OF THE CONCRETE SECTION (t) 1508.3 1115.6 1116.3 1118.8 615.3 247.7 246.7 245.4 244.5 252.1 155.9

70 CRACKED OR UNCRACKED un cr un cr un cr un cr un cr cr cr cr cr cr cr

71 V -Vp(ULTIMATE) (CALCULATED ABOVE) (t) 1416.2 917.8 786.5 697.8 563.2 419.8 301.2 166.6 23.0 0.0 160.8

73 MAX ALLOWABLE SHEAR STRESS ( FOR M 50 GRADE ) T/m2 487 487 487 487 487 487 487 487 487 487 470

75 Ved =(V-Vp) (t) 1416.2 917.8 786.5 697.8 563.2 419.8 301.2 166.6 23.0 0.0 160.8

a cw = 1.3 1.3 1.3 1.3 1.3 1.3 1.3 1.3 1.3 1.3 1.3
V Rd,max /(COT(THETA)+TAN(THETA)) (t) 3285.9 2489.4 2586.6 2686.9 1813.5 1900.9 1985.0 2062.9 2139.1 2214.4 2214.1

Theta( q ) 29.8 23.8 22.5 22.5 22.5 22.5 22.5 22.5 22.5 22.5 22.5
V Rd,max (t) 1417.7 919.3 914.5 950.0 641.2 672.1 701.8 729.3 756.3 782.9 782.8
OK OK OK OK OK OK OK OK OK OK OK

76 ASV/SV (TOTAL) (cm2/m) 11.78 8.89 8.89 8.89 5.99 20.62 14.16 5.99 5.99 5.99 6.78

78 ASV/SV PER WEB (cm2/m) 5.89 4.44 4.44 4.44 2.99 10.31 7.08 2.99 2.99 2.99 3.39

103
Ganga Bridge Between Arrah And Chapra P101010
Design of Box Girder Super Structure With Revised Dimensions of Segments (60m Span DN032RA

ULTIMATE STRENGTH CHECK(MAXIMUM SHEAR CASE)-For 2 Lane 70R

SR SECTION NO. UNITS SEC#2 SEC#3 SEC#4 SEC#5 SEC#6 SEC#7 SEC#8 SEC#9 SEC#10 SEC#11 SEC#12
NO
DISTANCE FROM END SUPPORT 2.900 5.900 7.800 9.700 12.700 15.700 18.700 21.700 24.700 27.700 28.900

DETAILS OF PRESTRESSING

1 HORIZ. PRESTR. FORCE - STG1 BOT (t) 8780.3 9053.1 9094.0 9139.6 9166.8 9118.5 9068.1 9003.0 8928.2 8893.7 8852.7
2 NO OF CABLES - STG1 BOT 25.58 25.58 25.58 25.58 25.58 25.58 25.58 25.58 25.58 25.58 25.58
3 CABLE C.G.(FROM BOTT.) (m) 1.475 1.401 1.323 1.243 1.088 0.976 0.869 0.769 0.672 0.576 0.577
4 VERT COMPONENT OF PRESTR. - STG1 BOT (t) 0.0 364.1 388.0 367.3 339.0 337.1 306.2 295.3 293.5 267.2 265.5
5 HORIZ. PRESTR. FORCE AFTER LOSSES - STG1 BOT (t) 7602.1 7875.0 7915.8 7961.4 7988.6 7940.3 7889.9 7824.8 7750.0 7715.5 7674.6
6 VERT PRESTR. FORCE AFTER LOSSES - STG1 BOT (t) 0.0 316.7 337.8 320.0 295.4 293.5 266.4 256.6 254.8 231.8 230.2
13 TOTAL HORIZ. PRESTR. FORCE AFTER LOSSES (t) 7602.1 7875.0 7915.8 7961.4 7988.6 7940.3 7889.9 7824.8 7750.0 7715.5 7674.6
14 TOTAL VERT COMPONENT OF PRESTR. AFTER LOSSES (t) 0.0 316.7 337.8 320.0 295.4 293.5 266.4 256.6 254.8 231.8 230.2
15 TOTAL NO OF CABLES 25.6 25.6 25.6 25.6 25.6 25.6 25.6 25.6 25.6 25.6 25.6
16 NET ECC FROM BOTTOM (m) 1.475 1.401 1.323 1.243 1.088 0.976 0.869 0.769 0.672 0.576 0.577

SECTION PROPERTIES

35 SOFFIT WIDTH (m) 6.900 6.900 6.900 6.900 6.900 6.900 6.900 6.900 6.900 6.900 6.900
36 DECK WIDTH (m) 20.500 20.500 20.500 20.500 20.500 20.500 20.500 20.500 20.500 20.500 20.500
17 WIDTH AT TOP OF CELL (m) 12.700 12.700 12.700 12.700 12.700 12.700 12.700 12.700 12.700 12.700 12.700
18 EFF WIDTH OF COMPR FLANGE (m) 20.500 20.500 20.500 20.500 20.500 20.500 20.500 20.500 20.500 20.500 20.500
19 WIDTH OF WEB BW (m) 0.610 0.460 0.460 0.460 0.310 0.310 0.310 0.310 0.310 0.310 0.310
20 NO OF WEB 2 2 2 2 2 2 2 2 2 2 2
21 DUCT DIA DDUCT m 0.110 0.110 0.110 0.110 0.110 0.110 0.110 0.110 0.110 0.110 0.110
22 EFFECTIVE WIDTHOF WEB (BW-0.5*DDUCT) m 1.110 0.810 0.810 0.810 0.510 0.510 0.510 0.510 0.510 0.510 0.510
23 DECK SLAB THICKNESS m 0.230 0.230 0.230 0.230 0.230 0.230 0.230 0.230 0.230 0.230 0.230
24 SOFFIT SLAB THICKNESS m 0.400 0.400 0.400 0.400 0.260 0.260 0.260 0.260 0.260 0.260 0.260
23 DEP OF COMPRESSION FLANGE m 0.230 0.230 0.230 0.230 0.230 0.230 0.230 0.230 0.230 0.230 0.230
24 Db m 2.720 2.720 2.720 2.720 2.720 2.720 2.720 2.720 2.728 2.824 2.823
25 TOTAL DEPTH OF BOX SECTION FOR SHEAR (m) 3.400 3.400 3.400 3.400 3.400 3.400 3.400 3.400 3.400 3.400 3.400
26 AREA OF BOX SECTION (m2) 13.739 13.739 12.362 12.362 10.371 10.371 10.371 10.371 10.371 10.371 10.371
27 C.G. OF BOX SECTION FROM BOTTOM (m) 1.990 1.990 2.028 2.028 2.213 2.213 2.213 2.213 2.213 2.213 2.213
28 MOMENT OF INERTIA OF BOX SECTION (m4) 20.576 20.576 19.716 19.716 16.023 16.023 16.023 16.023 16.023 16.023 16.023
29 AY BOX SECTION (m3) 10.340 10.340 9.722 9.722 7.240 7.240 7.240 7.240 7.240 7.240 7.240
30 AREA ENCL C/I OF BOX (Ak) (m2) 29.292 29.523 29.523 29.523 30.430 30.430 30.430 30.430 30.430 30.430 30.430
31 PERIMETER OF Ak (m) 25.160 25.310 25.310 25.310 25.600 25.600 25.600 25.600 25.600 25.600 25.600
S= First Moment of Inertia (m3) 5.310 5.310 5.310 5.310 5.310 5.310 5.310 5.310 5.310 5.310 5.310
32 FCK (Mpa) 45 45 45 45 45 45 45 45 45 45 45

104
Ganga Bridge Between Arrah And Chapra P101010
Design of Box Girder Super Structure With Revised Dimensions of Segments (60m Span DN032RA

ULTIMATE STRENGTH CHECK(MAXIMUM SHEAR CASE)-For 2 Lane 70R

SR SECTION NO. UNITS SEC#2 SEC#3 SEC#4 SEC#5 SEC#6 SEC#7 SEC#8 SEC#9 SEC#10 SEC#11 SEC#12
NO
DISTANCE FROM END SUPPORT 2.900 5.900 7.800 9.700 12.700 15.700 18.700 21.700 24.700 27.700 28.900

ULTIMATE SHEAR AND CORR. MOMENT


0 Shear Forces

33 DUE TO DL (t) 801.8 694.6 629.9 565.3 470.7 383.5 296.3 209.2 122.0 34.9 0.0
55 DUE TO STAGE 2 DL (t) 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0
34 DUE TO S.I.D.L. (t) 83.9 74.2 68.0 61.9 52.2 42.6 32.9 23.2 13.5 3.9 0.0
35 DUE TO LIVE LOAD (t) 178.0 159.0 147.3 139.6 126.1 116.6 106.5 97.6 87.5 78.7 52.3
36 DUE TO FOOTPATH LIVE LOAD (t) 17.5 15.6 14.5 13.4 11.8 10.3 8.9 7.6 6.4 5.3 12.0
36 DUE TO HYPERSTATIC REACTIONS IMM (t) 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0

TOTAL SHEAR (t) 1516.4 1323.9 1207.1 1096.3 929.5 779.0 627.6 478.2 327.0 177.9 160.8
37

Bending Moments

38 DUE TO STAGE1 DL (tm) 2482.7 4727.4 5985.7 7121.1 8675.0 9956.2 10975.9 11734.2 12231.0 12466.3 12487.3
66 DUE TO STAGE 2 DL (tm) 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0
39 DUE TO S.I.D.L. (tm) 256.7 493.8 628.9 752.3 923.6 1065.8 1179.0 1263.2 1318.3 1344.5 1346.8
40 DUE TO CREEP REDISTRIBUTION OF DL (tm) 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0
40 DUE TO LIVE LOAD (tm) 516.3 938.1 1149.1 1354.0 1601.7 1830.9 1991.5 2118.8 2161.8 2179.1 1574.3
41 DUE TO FOOTPATH LIVE LOAD (tm) 50.7 92.1 113.0 130.1 149.7 161.3 165.7 163.9 156.8 145.5 4.4
41 HYP IMM (tm) 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0
42 HYP INF (tm) 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0
43 DUE TO HYPERSTATIC REACTIONS (tm) 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0
44 DUE TO CREEP REDISTRIBUTION OF PRESTRESS (tm) 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0
45 DUE TO DIFFERENTIAL SETTLEMENT (tm) 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0
46 DESIGN MOMENT (tm) 4634 8759 11035 13111 15902 18238 20059 21419 22242 22618 21582.8

42 ULTIMATE DESIGN MOMENT (tm) 4634 8759 11035 13111 15902 18238 20059 21419 22242 22618 21582.8

484 174 79 -61 -184 -397 -545 -644 -676 -636 -614.8
Fctk0.05/1.5 -156 -156 -156 -156 -156 -156 -156 -156 -156 -156 156.4

105
Ganga Bridge Between Arrah And Chapra P101010
Design of Box Girder Super Structure With Revised Dimensions of Segments (60m Span DN032RA

ULTIMATE STRENGTH CHECK(MAXIMUM SHEAR CASE)-For 2 Lane 70R

SR SECTION NO. UNITS SEC#2 SEC#3 SEC#4 SEC#5 SEC#6 SEC#7 SEC#8 SEC#9 SEC#10 SEC#11 SEC#12
NO
DISTANCE FROM END SUPPORT 2.900 5.900 7.800 9.700 12.700 15.700 18.700 21.700 24.700 27.700 28.900

Shear capacity of the uncracked section

60 Design value of Concrete tensile strength(f ctd = f ct / g m ) (t/m2) 170.0 170.0 170.0 170.0 170.0 170.0 170.0 170.0 170.0 170.0 161.0

61 k1 = 1 for prestressed concrete 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0

61 s cp = Mean Compressive strength (t/m2) 553.3 573.2 640.3 644.0 770.3 765.6 760.8 754.5 747.3 744.0 740.0
FCD (t/m2) 2050.2 2050.2 2050.2 2050.2 2050.2 2050.2 2050.2 2050.2 2050.2 2050.2 2050.2
UNCRACKED SHEAR CAPACITY OF THE SECTION
2 1508.3 1115.6 1116.3 1118.8 615.3 613.8 612.2 610.1 607.7 606.6 404.5
(I * Bw /S * (SQRT (fctd2+ k1* s cp *f ctd )) (t/m )
62
1.25 1.25 1.25 1.25 1.25 1.25 1.25 1.25 1.25 1.25 1.25
Shear capacity of the cracked section

63 K =(1+sqrt(200/d)),d is in mm. (m) 1.271 1.271 1.271 1.271 1.271 1.271 1.271 1.271 1.271 1.266 2.823

64 r 1 = Min(A sl /b w /d,.02) (m) 0.020 0.020 0.020 0.020 0.020 0.020 0.020 0.020 0.020 0.020 2.213

(t/m2) 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 2474.4
3/2 (1/2)
65 Vmin = 0.031K f ck
66 V Rd,c 1 (tm) 443.0 329.8 352.0 353.2 248.6 247.7 246.7 245.4 244.5 252.1 16129.8

67 V Rd,c 2 =(V min +.15* s cp )b w *d t 342.2 256.2 278.4 279.6 202.3 201.4 200.3 199.0 198.1 204.1 116.3

68 SHEAR CAPACITY OF THE CRACKED SECTION (VCR) (t) 443 330 352 353 249 248 247 245 245 252 155.9

Check for Shear capacity & Shear Reinf. Calculations

69 SHEAR CAPACITY OF THE CONCRETE SECTION (t) 1508.3 1115.6 1116.3 1118.8 248.6 247.7 246.7 245.4 244.5 252.1 155.9

70 CRACKED OR UNCRACKED un cr un cr un cr un cr cr cr cr cr cr cr cr

71 V -Vp(ULTIMATE) (CALCULATED ABOVE) (t) 1516.4 1007.3 869.4 776.3 634.1 485.4 361.1 221.5 72.2 0.0 0.0

73 MAX ALLOWABLE SHEAR STRESS ( FOR M 50 GRADE ) T/m2 487 487 487 487 487 487 487 487 487 487 487

75 Ved =(V-Vp) (t) 1516.4 1007.3 869.4 776.3 634.1 485.4 361.1 221.5 72.2 0.0 0.0

a cw = 1.3 1.3 1.3 1.3 1.3 1.3 1.3 1.3 1.3 1.3 1.3
V Rd,max /(COT(THETA)+TAN(THETA)) (t) 3285.9 2489.4 2586.6 2686.9 1813.5 1900.9 1985.0 2062.9 2139.1 2214.4 2214.1

Theta( q ) 33.7 27.1 22.5 22.5 22.5 22.5 22.5 22.5 22.5 22.5 22.5
V Rd,max (t) 1517.5 1008.5 914.5 950.0 641.2 672.1 701.8 729.3 756.3 782.9 782.8
OK OK OK OK OK OK OK OK OK OK OK

76 ASV/SV (TOTAL) (cm2/m) 151.12 8.89 8.89 8.89 32.64 23.84 16.98 5.99 5.99 5.99 5.99

78 ASV/SV PER WEB (cm2/m) 75.56 4.44 4.44 4.44 16.32 11.92 8.49 2.99 2.99 2.99 2.99

106
Annexure: STAAD Input File for Longitudinal Analysis

STAAD SPACE
START JOB INFORMATION
ENGINEER DATE 17-Jan-11
END JOB INFORMATION
INPUT WIDTH 79
PAGE LENGTH 1000000
UNIT METER MTON
JOINT COORDINATES
28 -0.4 0 0; 1 0 0 0; 2 0.5 0 0; 3 1.1 0 0; 4 2.9 0 0; 5 5.9 0 0; 6 7.8 0 0;
7 9.7 0 0;
8 12.7 0 0; 9 15.7 0 0; 10 18.7 0 0; 11 21.7 0 0; 12 24.7 0 0; 13 27.7 0 0;
14 28.9 0 0; 15 30.1 0 0; 16 33.1 0 0; 17 36.1 0 0; 18 39.1 0 0; 19 42.1 0 0;
20 45.1 0 0; 21 48.1 0 0; 22 50 0 0; 23 51.9 0 0; 24 54.9 0 0; 25 56.7 0 0;
26 57.3 0 0; 27 57.8 0 0; 29 58.2 0 0
MEMBER INCIDENCES
1 1 2; 2 2 3; 3 3 4; 4 4 5; 5 5 6; 6 6 7; 7 7 8; 8 8 9; 9 9 10; 10 10 11;
11 11 12; 12 12 13; 13 13 14; 14 14 15; 15 15 16; 16 16 17; 17 17 18; 18 18 19;
19 19 20; 20 20 21; 21 21 22; 22 22 23; 23 23 24; 24 24 25; 25 25 26; 26 26 27;
27 28 1; 28 27 29;
START GROUP DEFINITION
MEMBER
_BGDIAPHR 27 28 1 26
_BGSUP 2 3 24 25
*_BGSUP1 3 4 23 24
_BG 8 TO 19
END GROUP DEFINITION
DEFINE MATERIAL START
ISOTROPIC MAT1
E 3.41906e+006
POISSON 0.17
DENSITY 2.5
ALPHA 1e-005
DAMP 0.05
END DEFINE MATERIAL
MEMBER PROPERTY INDIAN
_BGDIAPHR PRIS AX 36.507 IX 1e-005 IY 1e-005 IZ 34.440
_BGSUP PRIS AX 13.739 IX 1e-005 IY 1e-005 IZ 20.576
4 23 PRIS AX 13.050 IX 1e-005 IY 1e-005 IZ 20.146
5 6 21 22 PRIS AX 12.362 IX 1e-005 IY 1e-005 IZ 19.716
7 20 PRIS AX 11.3665 IX 1e-005 IY 1e-005 IZ 17.869
_BG PRIS AX 10.371 IX 1e-005 IY 1e-005 IZ 16.023
*MEMBER PROPERTY
*5 PRIS AX 12.849 IX 1e-005 IY 1e-005 IZ 19.97
*22 PRIS AX 12.849 IX 1e-005 IY 1e-005 IZ 19.97
*21 PRIS AX 12.362 IX 1e-005 IY 1e-005 IZ 19.716
*6 PRIS AX 12.362 IX 1e-005 IY 1e-005 IZ 19.716
*7 PRIS AX 12.362 IX 1e-005 IY 1e-005 IZ 19.716
*20 PRIS AX 12.36 IX 1e-005 IY 1e-005 IZ 19.716
CONSTANTS
MATERIAL MAT1 ALL
DEFINE MOVING LOAD
**************************CLASS A LOADING
**************************FORWARD TRAIN
TYPE 1 LOAD 2.7 2.7 11.4 11.4 6.8 6.8 6.8 6.8
DIST 1.1 3.2 1.2 4.3 3 3 3
**************************REVERSE TRAIN
TYPE 2 LOAD 6.8 6.8 6.8 6.8 11.4 11.4 2.7 2.7
DIST 3 3 3 4.3 1.2 3.2 1.1
**************************CLASS 70R LOADING
**************************FORWARD TRAIN
TYPE 3 LOAD 8 12 12 17 17 17 17
DIST 3.96 1.52 2.13 1.37 3.05 1.37
**************************REVERSE TRAIN
TYPE 4 LOAD 17 17 17 17 12 12 8
DIST 1.37 3.05 1.37 2.13 1.52 3.96
SUPPORTS
1 27 PINNED
*LOAD 1 SELF WT
*SELFWEIGHT Y -1
***DIAPHRAGM WT Due to Overhanging Portion
*JOINT LOAD
*1 27 FY -36.51
*LOAD 2 SIDL WEARING COAT
*MEMBER LOAD
**AS per Calculation
*1 TO 26 UNI GY -6.35
**
*LOAD 3 FOOTPATH LIVELOAD 1
*MEMBER LOAD
*1 TO 26 UNI GY -0.67
*LOAD 4 FOOTPATH LIVELOAD 2
*MEMBER LOAD
*2 TO 26 UNI GY -0.67
*LOAD 5 FOOTPATH LIVELOAD 3
*MEMBER LOAD
*3 TO 26 UNI GY -0.67
*LOAD 6 FOOTPATH LIVELOAD 4
*MEMBER LOAD
*4 TO 26 UNI GY -0.67
*LOAD 7 FOOTPATH LIVELOAD 5
*MEMBER LOAD
*5 TO 26 UNI GY -0.67
*LOAD 8 FOOTPATH LIVELOAD 6
*MEMBER LOAD
*6 TO 26 UNI GY -0.67
*LOAD 9 FOOTPATH LIVELOAD 7
*MEMBER LOAD
*7 TO 26 UNI GY -0.67
*LOAD 10 FOOTPATH LIVELOAD 8
*MEMBER LOAD
*8 TO 26 UNI GY -0.67
*LOAD 11 FOOTPATH LIVELOAD 9
*MEMBER LOAD
*9 TO 26 UNI GY -0.67
*LOAD 12 FOOTPATH LIVELOAD 10
*MEMBER LOAD
*10 TO 26 UNI GY -0.67
*LOAD 13 FOOTPATH LIVELOAD 11
*MEMBER LOAD
*11 TO 26 UNI GY -0.67
*LOAD 14 FOOTPATH LIVELOAD 12
*MEMBER LOAD
*12 TO 26 UNI GY -0.67
*LOAD 15 FOOTPATH LIVELOAD 13
*MEMBER LOAD
*13 TO 26 UNI GY -0.67
************************CLASS A FORWARD TRAIN
LOAD GENERATION 200
TYPE 1 -18.8 0 0 XINC 0.4
****************************CLASS A REVERSE TRAIN
LOAD GENERATION 200
TYPE 2 -18.8 0 0 XINC 0.4
***********************CLASS 70R FORWARD TRAIN
LOAD GENERATION 200
TYPE 3 -13.4 0 0 XINC 0.4
***************************CLASS 70R REVERSE TRAIN
LOAD GENERATION 200
TYPE 4 -13.4 0 0 XINC 0.4
PERFORM ANALYSIS
PRINT MEMBER FORCES LIST 1 TO 12
FINISH