Sunteți pe pagina 1din 4

9.

Technical specifications
Mini modular headend MMH3000
RF output parameters
Modulation DVB-T QPSK, QAM16, QAM64
Bandwidth 7 MHz, 8 MHz COFDM to COFDM (DVB-T) transmodulator ttx311
Guard interval 1/4, 1/8, 1/16, 1/32
1. Product description
Code rate 1/2, 2/3, 3/4, 5/6, 7/8 The ttx311 is DVB-T receiver with DVB-T modulator and transport stream remultiplexer with transparent modulator option.
transparent 2k, 8k It is intended to receive DVB-T signal, restore lost data (if still technically possible) and modulate the signal again into DVB-T
Mode RF channel. It can also be used in multiplexed mode (filter services or modify parameters of transport stream).
multiplexed 2k
Transmodulator is intended to use in the MMH3000 headend.
RF output frequency 110...860 MHz by 0.5 MHz step ttx311 is designed in accordance with standard EN50083-5 class 2.
RF offset (7 MHz) -125 kHz, 0, +125 kHz The unit is intended for indoor usage only.
RF offset (8 MHz) -166 kHz, 0, +166 kHz RoHS compliant.
Attenuation 0...15.5 dB by 0.5 dB step 2. Safety instructions
Nominal output level 90 dBV 1.5 dB Any repairs must be performed by a qualified personnel.
Module shall not be exposed to dripping or splashing water and no objects filled with liquids, such as vases, shall be
Carrier stability 500 Hz placed on it.
MER 35.0 dB Avoid placing module next to central heating components and in areas of high humidity.
Output impedance 75 No naked flame sources, such as lighted candles, should be placed on module.
If the module has been kept in cold conditions for a long time, keep it in a warm room no less than 2 hours before plugging
RF input parameters into the mains.
The ventilation should not be impeded by covering with items, such as newspapers, table-cloths, curtains.
Modulation DVB-T QPSK, QAM16, QAM64
Input frequency 104 ... 862 MHz This product complies with the relevant clauses of the European Directive 2002/96/EC. The unit must be recycled
or discarded according to applicable local and national regulations.
Input level 40 ... 100 dBV
Input impedance 75 3. Electrostatic discharge caution
Caution: The module contain electrostatic sensitive components. To minimize electrostatic discharge, observe the
Loop through gain 0 ... +3.5 dB following precautions:
Signal/Noise 23 dB - Do not remove module from their antistatic plastic bag until you are ready to install it into the basic unit.
- Hold the module only by the front panel of module.
- Do not place the module on an unprotected surface. Immediately after you remove a module from the
Multiplexing parameters (multiplexed mode only) basic unit, you must insert it into its antistatic plastic bag.
Input bit rate 31.5 MBit/s - When the module is not in use, keep it in their antistatic plastic bag.
Output bit rate 31.5 MBit/s (modulator bandwidth limited) - Do not ship or store module near strong electrostatic, electromagnetic or radioactive fields.
Input services 256 4. External view and operating control
PID filter 256
PMT Yes
Version
PAT No
monitoring
SDT No
PCR restamping Yes
EPG (EIT) multiplexing Yes

Other parameters
Supply voltage 5.5 0.1 V [1] - indicator of addressing
Current consumption 1.4 A
[2] - indicator of module's status
Output for ext. preamplifier 12 V 0.1 A, max.
Operating temperature range see UC360, UC380 manuals technical characteristics [3] - MPEG2 TS output connector
Dimensions /Weight 47.5 x 117 x 220.5 mm / 0.7 kg
[4] - RF input of DVB-T signal, preamplifier powering

[5] - RF loop through output

[6] - fixing screws

Figure 1. External view of module

5. Installation instructions
Read the instruction first.
Disconnect base unit from the mains before insertion/changing the module.
Before pushing the module into the direction of bus bar, carefully put the edges of module PCB into grooved guides,
stamped in the base unit. Fasten the module by supplied fixing screws.
Draugystes str. 22, LT-51256 Kaunas, Lithuania, tel.: +370 37 - 31 34 44, fax: +370 37 - 31 35 55 Place serrated lock washer with external teeth on module and nut on adapters as described in the user manuals of base
E-mail: terra@terraelectronics.com, http://www.terraelectronics.com units UC360, UC380.
After 7-10 seconds of powering the module will run in normal operation mode. Input stream => Rescan
RF input signal can be connected directly to [4] connector, or via loop through outputs of other modules. Command will erase previous list of services, and rescan new list. After scanning, all services are disabled. Each service
Any other module's DVB-T RF input (or analog TV RF input) can be connected to ttx311 loop through output [5]. must be enabled individually.
Comments of the front panel indicators:
[ 1 ] - Address indicator. It lights on green when the module is addressed on Terra Bus bus. Blinking indicator indicates Input stream =><List of services>
addressing error. "Enter" key will toggle selection of the service. If the second character has "^" sign, it means that the service is selected.
[ 2 ] - Status indicator. It lights on red when any error occurs. It will start blinking at power on to indicate a starting up Otherwise it is disabled.
status. Input stream => Save & Run
Will save all information, generate all SI tables and run with new settings.
6. Default settings
DVB-T receiver parameters: Input Params => Input Freq.
- Input Frequency, kHz: 474000 DVB-T input frequency, kHz.
- Bandwidth, MHz 8 Input Params => Input Bandw.
DVB-T input channel bandwidth (7 or 8 MHz).
DVB-T modulator parameters:
- Modulation QAM64 Input Params => Preamp. Power
- Bandwidth: 8 MHz DVB-T input antenna powering On/Off.
- Guard interval: 1/32 OFDM Params => Modulation
- Code rate: 7/8 Allows to select the modulation (constellation) between QPSK, QAM16 and QAM64.
- Cell ID: 0 OFDM Params => Bandwidth
- RF: Off Allows to select the bandwidth of the RF output between 7 and 8 MHz.
- Saw filter: Off OFDM Params => Guard Interval
- RF Frequency: 474 MHz Allows to select guard interval between 1/4, 1/8, 1/16 and 1/32.
- RF Offset: 0 kHz OFDM Params => Code Rate
- Attenuator: 0.0 dB Allows to select code rate between 1/2, 2/3, 3/4, 5/6 and 7/8.
OFDM Output stream parameters (in multiplexed mode only): OFDM Params => Cell ID
- Transport Stream ID: 1 Allows to enter Cell ID value 0..65535.
- Network ID: 1 OFDM Params => RF
- Network Name: none Allows to turn On / Off RF of modulator.
- Date/Time source: DVB-T Input
- Timing zone: 0 GMT OFDM Params => Saw filter
- NIT: Disabled Allows to turn On / Off saw filter of intermedium frequency. Parameter can be actual if analog TV channel is adjacent
- EPG Multiplexing: Enabled to OFDM channel.
OFDM Params => Out. Frequency
7. Operating Allows to setup output frequency of modulator.
Device receives DVB-T signal and outputs transport stream to connector [3] transparently (without any modification). This
signal can be connected to other devices of MMH headend, which accepts TS. OFDM Params => RF Offset
In case of multiplexed mode, system processes incoming transport stream (measures bitrate, generates PSI, filters services, Allows to setup RF offset of modulator. 166 kHz for 8 MHz bandwidth, and 125 kHz for 7 MHz channel.
restamples PCR, multiplexes EPG) and passes to modulator. System monitors PMT tables (up to 32) and updates the output OFDM Params => Attenuator
of multiplexer if any changes detected (for example: new stream detected, new descriptors added or removed). Allows to setup RF attenuation in a range of 0..15.5 dB.
In case of transparent mode, incomming transport stream passes directly to modulator without any modification of transport Network Params => Stream ID
stream. Only PCR restamping is turned on in this mode. Stream ID value. Requires to execute "Save & Run" command from "Input Stream" menu.
All parameters can be setup via user friendly graphic interface, which supports Terra Link, CMH Master software, PCS200 server. Network Params => Network ID
"Home" tab of ttx311's control panel will appear when device was selected (see corresponding software user manual). See Figure 2. Network ID value. Requires to execute "Save & Run" command from "Input Stream" menu.
System Status => List of Errors
Shows all errors of the systems. Use "Up" and "Down" buttons to review all of them.
System status => Input status
Shows input bitrate and C/N. It also shows RF level if tuner is unlocked.
System status => Output status
Shows output bitrate and the usage of available bandwidth
System Info => Product
Shows the name of the device.
System Info => Serial Number
Shows serial number of the device.
System Info => Soft. Version
Shows software version of the device.
System Info => System time
Shows system time of the device. NOTE: timing zone and date/time source must be setup correctly. These settings
Figure 2. Home tab of ttx311 control panel available only with PC control software.
System Info => Temperature
Three sections exist on this page. "Input channel" table shows parameters of incoming transport stream (DVB-T demodulator).
Shows internal temperature C of the device.
"Signal status" shows transport stream detection status. "Bit Rate" shows bit rate of incoming transport stream.
"Output channel" table shows parameters of outgoing transport stream. "Max. Bitrate" - this is the maximum available
output bit rate according to OFDM modulation parameters (code rate, guard interval, etc). "Current Bitrate" shows bitrate
of outgoing transport stream. "Used bandwidth" value is calculated from previous two values, and indicates the percentage
of used bandwidth.
NOTE: Ensure that used bandwidth would not exceed 95%. Otherwise bit rate overflow would occurs. In case of bitrate overflow
error, indicated bitrate values will be inaccurate because a device can not measure bitrate in such error condition.
"System status" table indicates main information about the device (device name, serial number, software and hardware
version, internal temperature, system time). This table also will show all errors of device operation.
Device has internal clock, and a value 1970.01.01 00:00:00 will be assigned after system startup. The clock will be updated
automatically from transport stream TDT table.
Information on this page is updated automatically in real time.
2 7
Exact broadcasting parameters must be written for selected stream.
All streams (modulators) must be described here and all other modulators must have the same description table.
NOTE: Only terrestrial descriptor has user-friendly editor. All the reset descriptors can be added in hex format only. Values
must be added according to EN 300 468 standard, starting after descriptor_length field. descriptor_tag and descriptor_length
will be added/calculated automatically.
NOTE: This descriptor for current modulator (current transport stream) is generated automatically according to modulation
parameters. User must take care only about the rest transport stream descriptions.
Spaces between hex values can be added, but it is not necessary.
Press "Save and RUN" when all NIT modifications are done.
Logical Channel Descriptors can be added into the 1st section of NIT, which represents services of current stream only.
"Selected channels" table has a list of all currently enabled services. If "Log. channel" field is other than zero, a LCD (Logical
Channel Descriptor) will be added for that channel.
LOGs section

Figure 3. "DVB-T Input" section of ttx311 control panel

DVB-T Input section (see figure 3) allows to setup RF reception parameters, displays status of demodulator.
Figure 9. LOGs section of ttx311 "Input Frequency" - The frequency of RF input signal. Dimmension - kHz.
All errors or most important events will be logged in this section. "Erase log" button allows to clear all logs. "Bandwidth" - The bandwidth of DVB-T input channels. Possible values: 7 MHz, 8 MHz
20 records per page can be displayed. Page selector will appear on the screen if more than 20 records are in the system. "Preamplifier Powering" - +12 V Preamplifier Powering On/Off
This page will be refreshed automatically when a new event occurs in the system. "DVB-T receiver status" shows the status of demodulator. Device measures signal level, signal/noise ratio and shows
"Download log" link allows to download all log records from the system as a text file. other information of transponder (modulation, guard interval, code rate, mode).
NOTE: This feature works with Terra Link starting from 1.6.0 version or CMH Master starting from 1.0.3.0. Parameters of demodulator in this page are updated in real time.
8. Handheld control unit Transparent mode can monitor DVB-T input channel parameters and update the output modulation parameters accordingly.
Handheld unit allows to control the most important parameters of the device. Select "Update automatically on any change" option to synchronize modulation parameters automatically.
Select the ttx311 device (see user manual of handheld unit). "Control" menu item will appear. Menu tree will appear on
the screen. The first character ">" marks currently selected menu item. Some menu items has "^" character in the second DVB-T Input / Stream section (Multiplexed operating mode only)
position of the line. It means that current menu item is checked.
Use "Up" and "Down" buttons to surf through the menu. Use "Enter" key to enter into deeper submenu or execute the
command associated with it. "Esc" key will exit to upper menu or cancel the execution of a command.
ttx311 has the following menu tree:
Input streams Rescan...

List of services

SAVE & RUN

Input params Input freq.


Figure 4. "DVB-T Input / Stream" section of ttx311 control panel
Input bandw.
This is a transport stream multiplexer section of device, which is available in "multiplexed" mode only (see "DVB-T Output"
description). Valid transport stream must exists (DVB-T demodulator must be locked) to start working with this section. "Load
Preamp.power streams" button will load information of the stream. All found services will be listed below the button. Lock symbol at the
OFDM params Modulation beginning of service name indicates that a service is scrambled. Next icon represents the type of service. Following icons
are possible:
Bandwidth Cell ID Out.frequency
- High definition television

Guard interval RF RF offset - Standard definition television

Code rate Saw filter Attenuator - Radio


Unidentified service types will not have any icon.
Network params Stream ID NOTE: Lock sign only identifies a flag of SDT table, and does not check the content itself.
Check "Enable" checkbox and press "Enable services" to pass that service to modulator. After few seconds a service will
Network ID be activated and passed to modulator.
NOTE: Press "Home" tab to see used bandwidth of selected services. Ensure that it takes not more than 90-95% of
System status List of errors available bandwidth, and no any bitrate overflow errors are there.
Press sign if you want to see or change more details about the service. New area with information about the service
Input status will be expanded. See Figure 5.

Output status

System info Product

Serial number System time

Soft. version Temperature


6 3
In case of transparent mode original NIT (if any) will be passed to the output.
Other parameters:
Operating mode - this parameter switches device between two operating modes - transparent or multiplexed mode.
In case of transparent mode, original transport stream passes to modulator without any modifycations. Transparent
operation mode supports 2k and 8k modulation modes.
In case of multiplexed mode all multiplexing features are enabled (NIT generation, service filtering). Modulator can work
in 2k modulation mode only in multiplexed case.
A device will be restarted after switching this parameter, and will start operating after 10 seconds.
"Timing zone" selection used for system clock only, and it does not affect the output stream. This parameter exists in both
operating modes, but in case of multiplexed mode, the parameter is moved to "DVB-T Output/Stream" control panel.
DVB-T Output / Stream section (Multiplexed mode only)

Figure 5. Service details


List of all streams and other parameters will appear. Some streams will have icons, which indicates the type of the stream.
Following icons are possible:
- Sound stream

- DVB Subtitles
- Teletext
- Video
Language code will be visible in round brackets if presented in the stream.
Lock sign identifiers conditional access streams, which affects a stream or a whole service (like in example above).
Most of the streams of the service can be disabled (filtered) by unchecking "Enabled" check box.
A service name and service provider name can be changed here.
"Monitoring" check box turns on monitoring of PMT version changes. If it is checked, new PMT table will be reloaded if
the version of the table is changed. New appeared streams will be added to the service automatically. Disappeared streams
will be removed from the service as well. The device does not take into account possible bit rate overflow of new multiplex.
User must take care about it. Use this feature only in case if it is necessary. If unsure, leave it unchecked.
"Scrambled" flag can be switched on/off. If the flag is off, SDT table will be generated without "scrambled" flag and all CA
descriptors will be removed from the service.
Press "Update program information" button to modify details of the service. Figure 7. OFDM Output/Stream parameters of ttx311
NOTE: "Enable services" button will need to be pressed to save all the changes and for them to take effect.
Output stream parameters can be configured in this section. The most important parameters are Stream ID and Network
DVB-T Output section ID. User must ensure that Network ID number is identical in all broadcasting equipments, and Transport stream ID must be
unique for every modulator or other streaming equipment.
Private Data Specifier field optionally can be used to identify the broadcaster or country. It should be assigned according to
EN 101 162 specification. All allocated values can be find here: http://www.dvbservices.com/identifiers/private_data_spec_id
Hexadecimal value should be entered here. The descriptor will be used together with LCN descriptor. If unsure - enter
zero. In that case the Private_Data_Specifier will not be used at all.
"Network Name" used in NIT (Network Identification Table) and it represents broadcaster.
"Date/Time source" selects the source of the clock. TDT (Time and Date Table) will be passed to the output from selected
source. Also a system clock will capture current time values from this source.
"Timing zone" selection used for system clock only and it does not affect the output stream. TOT (Time Offset Table) is
passed transparently to the output from selected source, which carry timing zone information to the end-user.
"NIT Enable" parameter allows to turn On/Off NIT generation.
"EPG Multiplexing" parameter allows to turn On/Off multiplexing of EPG (Electronic Program Guide). The system will
multiplex EPG (EIT) if this parameter is turned on. EPG multiplexing part takes original EIT (Event Information Table),
modifies StreamID, NetworkID values, and sends the stream to the output of multiplexer. EIT will be passed (multiplexed)
for enabled services only.
New button "Save and RUN" will appear if any value of this section was changed. Press it to save all changes and run
Figure 6. OFDM parameters of ttx311 control panel the system with modified values.
Next important part of this section is NIT configuration. Broadcaster can describe whole network there, so receivers (TV, set-
There are three tables in this section - modulator parameters, RF parameters and other parameters. top-boxes) will be able to scan all channels automatically. The most important note to remember - Network ID number must be
Modulator parameters: identical in all broadcasting equipments and Transport stream ID must be unique for every modulator or other streaming equipment.
Modulation - modulation type. Possible values: QPSK, QAM16, QAM64 Enter NetworkID and StreamID values in "New Stream Description" table to start describing a stream (the output of each
Bandwidth - 7 or 8 MHz modulator in the system). New empty record for that stream will appear above that table. Press sign to expand a description
Guard interval - 1/4, 1/8, 1/16, 1/32 and add all necessary descriptors for that stream. Select a descriptor (probably only "terrestrial_delivery_system_descriptor"
Code rate - 1/2, 2/3, 3/4, 5/6, 7/8 will need) from the list and press "Create new descriptor" button. New empty descriptor will be added. Press onto again
Cell ID: - Any value 0..65535 can be entered. to expand stream description. New inserted descriptor will be found. Press onto to edit it's values (see Figure 8).
Mode: - 2k/8k (2k only in case of multiplexed operating mode)
RF parameters:
RF On/Off - Allows to switch RF On or Off at the output
Saw filter - Enable or disable 8 MHz (or 7 MHz) saw filter at intermediate (36 MHz) frequency. If the frequency
offset 166/125 kHz is used, a filter will be switched off automatically.
RF Frequency - Output frequency of modulated COFDM signal. Step - 0.5 MHz.
RF Offset - Output frequency offset 166 kHz or 125 kHz in 7 MHz bandwidth case.
Attenuator - RF Output attenuation in 0.0 .. 15.5 dB range.
NOTE: terrestrial_delivery_descriptor in NIT will be changed automatically after a change of any modulation parameters in
multiplexed operating mode. Open "DVB-T Output/Stream" tab and press "Save & Run" to save new values of descriptor.
4 Figure 8. Terrestrial descriptor 5