Documente Academic
Documente Profesional
Documente Cultură
Types K, R, N, and C
Catalog
8501CT0301R7/08
2008
Class 8501
CONTENTS
Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Page
Type R Miniature Plug-in Relays . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .36
Type K Plug-in Relays . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .78
Type KA Alternating Relays. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .910
Type N Sockets and Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . 1113
Type C Power Relays . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .15
2
08/2008 2003-2008 Schneider Electric
All Rights Reserved
Type R Miniature Plug-in Relay
General and Order Information
Input
Options Type
Voltage
SPDT None RS41*
None RSD41*
RS43 S S RSD43 S
How to Order:
RS43M1 RSD43M1
To Order Specify: Catalog Number
RS43P14 S RSD43P14
Class Number
Class Type Voltage Code
RS43M1P14 S RSD43M1P14 Type Number
8501 RS42 V20
Voltage Code
RS44 S S S RSD44 S S (See Stocked Relay Table to left)
RS44M1 RSD44M1
Application Data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 5
RS44P14 S RSD44P14 S Wiring Diagrams . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 6
Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 6
RS44M1P14 S RSD44M1P14
S Stocked
Factory Order items require a minimum order quantity of 25 and have a lead time of 12 weeks.
3
2003-2008 Schneider Electric 08/2008
All Rights Reserved
Type R Miniature Plug-in Relay
General and Order Information
8501 R relays are suited for use as logic elements and power
switching output devices. The short stroke motion of the
armature provides long mechanical life required for high speed
operation of control systems. Different contact compositions
allow these relays to be used in a variety of applications. Fine
silver (gold flashed) and bifurcated crossbar (gold overlay
silver) are suitable for high contact reliability and low level 8501 RS4V14
switching requirements. Silver cadmium oxide is best suited for
inductive loads. Hermetically sealed relays can be used in
Pilot Light Option
adverse environments.
An Internal green pilot light is available in
1, 3, or 5 Ampere Versions Horsepower Rated
both AC and DC versions for positive
4PDT AC or DC Operation
indication of power to the coil. The pilot lights
Complete Socket Line Manual Operator/ are bidirectional LEDs.
Pilot Light Options
4
08/2008 2003-2008 Schneider Electric
All Rights Reserved
Type R Miniature Plug-in Relay
Ordering Information and Application Data
Stocked Relays
AC Voltage 50/60 Hz DC Voltage
Type Type
6 12 24 48 120 240 6 12 24 48 110
Voltage Code V35 V36 V14 V17 V20 V24 Voltage Code V50 V51 V53 V56 V60
RS4 S S RSD4 S S
RS4M1 S RSD4M1
RS4P14 S RSD4P14 S
RS4M1P14 S RSD4M1P14 S
RS14 S S S RSD14 S S S
RS14M1 S RSD14M1 S
RS14P14 S RSD14P14 S S S
RS14M1P14 S S RSD14M1P14 S S
RS24 S RSD24 S
RS34 S RSD34 S S
S Stocked
Factory Order items require a minimum order quantity of 25 and have a lead time of 12 weeks.
Class 8501 Type RS4 RSD4 RS14 RSD14 RS24 RSD24 RS34 RSD34 RS41 RSD41 RS42 RSD42 RS43 RSD43 RS44 RSD44
Pick-Up
25 ms Maximum 13 ms Max. 20 ms Maximum
Time
Drop-Out
Operating 25 ms Maximum 6 ms Max. 20 ms Maximum
Time
Data
Operating
-40 C to +70 C -45 C to +70 C -40 C to +70 C
Temperature (-40 F to +158 F) (-49 F to +158 F) (-40 F to +158 F)
Range
DC Coils 0.9 watt 0.9 watt 0.9 watt 0.9 watt 0.7 watt 0.9 watt 1.0 watt 1.0 watt
E197072
File E196809
NRNT8 N/A
CCN NQMJ2, NQMJ8
(Approved but not marked)
Yes
5
2003-2008 Schneider Electric 08/2008
All Rights Reserved
Type R Miniature Plug-in Relay
Dimensions and Wiring Diagram
Wiring Diagrams
1
1 2 1 2 3 1 2 3 4 1 2 3 4
5
3 4 4 5 6 5 6 7 8 5 6 7 8
9 5 6 7 8 9 9 10 11 12 9 10 11 12
7 8 10 11
13 14 13 14 13 14
RS41, RSD41 RS42, RSD42 RS43, RSD43 RS44, RSD44 RS4, RSD4, RS14, RSD14, RS24,
RS24, RSD24, RS34, RSD34
.86 .91
For devices with 23.1 .75
manual operator 21.8 .75
.25 19 .04 .25 .31 19
.04 .31
.21 1 6 1 6 8
B65112-124 8 B65112-124
5
3 4 1 2 3 4
1 2
5 6 7 8 5 6 7 8
1.10 1.16
#3-48 NC- #3-48 NC- 29.5
12 27.9 9 10 11 12
9 10 11 2A THREAD
2A THREAD
13 14 13 14
.26 .26
7 7
16.002
0.630
0.070 Provided)
1.42
36.1
1.77
36.068
1.420
(When
22.10
0.870
(When Provided)
Provided) (When
Provided)
5
3
1
5
1
9
4
6
RS42, RSD42
8
RS41, RSD41
31.49
(When
(When
(When
(When
16.002
0.630
Provided) Provided)
16.002
0.630
36.07
1.42
36.07
1.42
22.10
0.870
22.10
0.870
10
7
4
1
6
2
11
5
8
3
7
11
14
12
3
6
9
4
8
Inches
Dual Dimensions:
Millimeters
6
08/2008 2003-2008 Schneider Electric
All Rights Reserved
Type K - Plug-in Relay
Dimensions and Wiring Diagram
8501 K relays are designed for multipole switching applications
at 240 volts or lower. These relays have industry standard Type KP Tubular Terminals
wiring and pin arrangements which allows for their use as Input Contact
Options Type
replacements for many similar relays without wiring or Voltage Arrangement
DPDT None KP12
hardware modifications.
AC DPDT Pilot Light KP12P14
50/60
10 or 15 Ampere Versions Horsepower Rated Hz 3PDT None KP13
c
3PDT Manual Operator KU13M1
Socket is not required with Type KF relays.
3PDT Pilot Light KU13P14
Manual Operator
3PDT KU13M1P14
Type KL Latching Relay Spade Terminals and Pilot Light
DPDT None KUD12
Input Contact
Options Type DPDT Manual Operator KUD12M1
Voltage Arrangement
DPDT Pilot Light KUD12P14
AC Manual Operator
DPDT None Available KL12 DPDT KUD12M1P14
50/60 Hz and Pilot Light
DC
3PDT None KUD13
3PDT Manual Operator KUD13M1
DC DPDT None Available KLD12
3PDT Pilot Light KUD13P14
Manual Operator
3PDT KUD13M1P14
and Pilot Light
Pilot Light Option Available on Types KP and KU. Internal pilot lights are available in both
Stocked Relays ac and dc versions for positive indication of power to the coil. The pilot light will be a red
bidirectional LED.
AC Voltage 50/60 Hz DC Voltage Manual Operator Option Available on Type KU only. To speed circuit testing a manual
Type Type
6 12 24 120 240 6 12 24 48 110 125 operator can be provided. With this feature the relay can be manually switched to simulate
Voltage normal operation.
V35 V36 V14 V20 V24 Voltage Codes V50 V51 V53 V56 V60 V63
Codes
KP12 S S S S S KPD12 S S S S S S Application Data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 8
KP12P14 S S S S KPD12P14 S S S S Dimensions. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 8
KP13 S S S S KPD13 S S S S S Sockets . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 14
KP13P14 S S S KPD13P14 S S
KU12 S S S S KUD12 S S
KU12M1 KUD12M1 S
KU12P14 S S KUD12P14
KU12M1P14 S S S KUD12M1P14 S
KU13 S S S S KUD13 S S S S
KU13M1 KUD13M1 S
KU13P14 S S KUD13P14
KU13M1P14 S S S KUD13M1P14 S S S
KF12 S S S KFD12 S S
KF13 S S KFD13 S
KL12 S S S KLD12 S S
S Stocked
Factory Order items require a minimum order quantity of 25 and have a lead time of 12
weeks.
Voltage code must be specified to order this product. Refer to standard voltage codes listed in the
How to Order:
To Order Specify: Catalog Number
Class Number
Class Type Voltage Code
Type Number
8501 KP12 V20
Voltage Code
(See Stocked Relay Table above)
7
2003-2008 Schneider Electric 08/2008
All Rights Reserved
Type K Plug-in Relay
Application Data, Dimensions, Wiring Diagrams
Wiring Diagrams
Contact Ratings
1 3 4 5 1 3
AC DC 3 6 4 6
4 6
Resistive 75% 7 9 7 9
AC DC Resistive 2 7
Type PF Continuous HP 8
Volts Volts Amperes A B
Amperes 1 8 RESET
1/ A B
120 10 3 KU12, KUD12 KP12, KPD12
KPl 28 10 COMMON LATCH
240 10 c 1/ KF12, KFD12
2
6
120 15q 1/ 5 7 KL12
KUl 3 1 2 3
28 10
KFl 240 10c 1/ 4 8 1 3
2 4 5 6
4 6
120 10 1/ 7 8 9
3 3 9
KL 28 10 7 9
240 10 1/ 2 10
2 A B
1 11
l 8501 KP, KU, and KF relays have a B300 rating. A B
c 3 pole devices have a 20 A max. total (sum of currents in all 3 poles), continuous rating. KU13, KUD13 LATCH +
KP13, KPD13 + RESET
q 3 pole devices have a 30 A max. total (sum of currents in all 3 poles), continuous rating. KF13, KFD13
KLD12
Operating Data
Approximate Dimensions
Type Comments
.16 dia.
AC coil: approximately 12 ms 4.0
KP
DC coil: approximately 18 ms 1.79 2.13
Typical Pick-Up 45.5 54.2
AC coil: approximately 8 ms MAX
Time KF, KU 1.15 2.07 2.66
DC coil: approximately 11 ms
29.3 52.6 67.5
KL approximately 25 ms
Type KP
Contacts
Configuration 2PDT or 3PDT (2 or 3 Form C)
8
08/2008 2003-2008 Schneider Electric
All Rights Reserved
Type KA Alternating Relays
General Information and Specifications
LED, Toggle,
AC & DC DPDT 8501KA82
Duplex Pumping
LED, Toggle
AC & DC DPDT (N.C.) 8501KA112
LED, Toggle
AC & DC DPDT (N.O.) 8501KA112A
Contact Ratings
AC DC
Type Resistive Resistive
AC Volts HP Pilot Duty DC Volts
8501 KA alternating relays are designed to minimize pump and Amperes Amperes
motor wear by equalizing run time between parallel 120 12 1/3 B300
8501KA 30 12
components in a multi-pump system. These relays are 240 12 1/2 B300
controlled by an external control switch. This switch may be any
type of contact closure; for example, the contacts of a timing Relay Availability
relay or the closure of a float switch. The 8501 KA relays also
have a toggle switch that allows the operator to lock one side of AC & DC Voltage AC Voltage
Type
the duplex system, preventing alternation. 12 24 120 240
Voltage Code V36 V14 V20 V24
8501KA S S
SPDT or DPDT AC and DC Control
8501KA S S
Toggle switch for load control UL Listed w/ SquareD Socket
8501KA S S
LED Load Indicators Rohs Compliant
AC Voltage = 50/60 Hz
S Stocked. Stocked items do not require a minimum quantitiy and have a lead time of 2 weeks.
All other part numbers require a minimum order quantity of 100 and have a lead time of
18 weeks.
Alternating Functions
Diagram Toggle Switch Position Detail S1 = Control Switch 1 S2 = Control Switch 2 LA = Load 1 LB = Load 2
Alternate Closing S1 alternates the loads between LA and LB.
Alternate Closing S1 alternates the loads between LA and LB. S2 will only control LA.
The cross wired option allows extra system load capacity through simultaneous operation of both motors when needed (LA and LB energize simultaneously when both S1 and
S2 are closed - relay contacts are not isolated).
Input voltage must be applied at all times for proper alternation. Use of a solid state control switch for S1 or S2 may not initiate alternation correctly. S1 or S2 voltage must be
All
from the same supply as the units input voltage (see wiring diagrams). Loss of input voltage resets the unit; LA becomes the lead load for the next operation.
9
2003-2008 Schneider Electric 08/2008
All Rights Reserved
Type KA Alternating Relays
Wiring Diagrams and Approximate Dimensions
Wiring Diagrams
A B
V
S1
8501KA81 8501KA82
Socket = 8501NR51 or NR52 Socket = 8501NR51 or NR52
C D
8501KA112 8501KA112A
Socket = 8501NR61 or NR62 Socket = 8501NR61 or NR62
Approximate Dimensions
10
08/2008 2003-2008 Schneider Electric
All Rights Reserved
Type N Sockets and Accessories
General and Order Information
8501 NR sockets are designed for use with plug-in 8501 K and
Type R relays, 8430 MPS phase failure relays and 9050 JCK
timers. The 8501 NR45 screw terminal sockets have pressure
wire clamps that accept 1 or 2 #16-22 wires. All other sockets
have pressure clamps that will accept 1 or 2 #12-22 wires.
The recommended tightening torque for all terminals is
7-8 lb-in.
8501 NR51 8501 NR61
All Devices Stocked in Central Warehouse
DIN Track Mount or Direct Panel Mount
Tubular Sockets Available in Easy-to-Wire Single Tier or
Space-Saving Multi-Tier Versions
Snapmount Sockets
Socket
For Use With
Rating Class
Std.
8501 NR52 8501 NR62 8501 NR82
Class Class Class Description 8501
Qty.
8501 8430 9050 UL CSA Type
Type Type Type
10 A
JCK11 19 8 Pin Tubular 600 V 10 A NR51 1
JCK31 39 Single Tier 15 A 300 V NR51B 10
JCK51 59 Screw Terminal
KP12 MPS 300 V
JCK60
KPD12 (240 volts) 5A
JCK1 F 8 Pin Tubular
JCK3 F 600 V 10 A NR52 1
JCK5 F
Double Tier 16 A 300 V NR52B 10 8501 NR45 8501 NR41 8501 NR42
Screw Terminal 300 V
5 A 10 A
11 Pin Tubular 600 V 300 NR61 1
JCK21 29 Single Tier V
15 A q NR61B 10
JCK41 49 Screw Terminal
KP13 300 V
JCK70
KPD13 5 A 10 A
JCK2F 11 Pin Tubular
JCK4F 600 V 300 NR62 1
Double Tier V
16 A q NR62B 10
Screw Terminal 300 V
11 Pin Spade 8501 NR34
KL MPS Double Tier 15 A NR82 1 8501 NH7 8501 NR43
KU (480 Volts) 300 V j NR82B 10
Screw Terminal
5 Pin Spade
RS41 15 A NR41 1
Double Tier
RSD41 300 V j NR41B 10
Screw Terminal Socket Accessories
8 Pin Spade
RS42 10 A NR42 1
Double Tier
RSD42 Screw Terminal 300 V NR42B 10 Catalog Std.
Socket For Use With Description
Number Pack
RS43 11 Pin Spade 10 A NR43 1
Double Tier 8501NR51 8501KP12, KPD12 Hold Down Clip Not Available
RSD43 300 V q NR43B 10
Screw Terminal
14 Pin Spade 8430MPSV24 Restraining Strap 8501NH7 1
RS44 10 A NR34 1
Double Tier
RSD44 300 V q NR34B 10 9050JCK Restraining Strap 8501NH7 1
Screw Terminal
RS4 8501NR52 8501KP12, KPD12 Hold Down Clip 8501NH52 10
RSD4
RS14 8430MPSV24 Restraining Strap 8501NH7 1
14 Pin Spade
RSD14 10 A NR45 1
Double Tier
RS24 300 V NR45B 10 9050JCK Restraining Strap 8501NH7 1
Screw Terminal
RSD24
RS34 8501NR61 8501KP13, KPD13 Hold Down Clip Not Available
RSD34
9050JCK Restraining Strap 8501NH7 1
Must be ordered in multiples of the quantity listed. Units provided in standard quantity of one
are individually packaged; devices with B suffix have a standard quantity of 10 per bulk pack. 8501NR62 8501KP13, KPD13 Hold Down Clip 8501NH52 10
Rated for use with Class 8430 Type MPS at 480 Volts.
q 20 A maximum total load (CSA) 9050JCK Restraining Strap 8501NH7 1
File E66924 File LR84913 8501NR43 8501RS43, RSD43 Hold Down Clip 8501NH42 10
CCN SW1V2 Class 3211 07
8501NR34 8501RS44, RSD44 Hold Down Clip 8501NH42 10
11
2003-2008 Schneider Electric 08/2008
All Rights Reserved
Type N Sockets and Accessories
General and Order Information
TERMINAL 1.016
3 2 1 LOCATION 25.79
80.26
3.16
6 5 4 0.718
0.150 18.20
MADE IN CHINA
1.210
3.81 0.656
76.20
3.00
3 2 1 TERMINAL
30.73
16.66
31.75
1.250
LOCATION
8 7 6 5 8 7 6 5
B A
42.16
1.660
4 3 2 1
0.070 4 3 2 1
1.18
2.032 Typ.
0.080
9 8 7
31.75
1.250
1.52 0.680
17.26
69.85
2.750
38.70
1.55 0.865
39.31 21.97 B A 14 13
32.13
1.265
1.703
0.955 1 1
64.29
2.530
43.25 9 4 3 12 11 10 9
24.25 8 7
Terminal Screws M3.5 x 0.6 1.030 TOP VIEW TOP VIEW
1 1 1
9
26.16 2 1 0
12
2003-2008 Schneider Electric All Rights Reserved 12/03
Type N Sockets and Accessories
General and Order Information
Terminal Screws M3 X 0.5 Terminal Screws M3.5 X 0.6 Terminal Screws 6-32 x 5/16"
4 3
TERMINAL
A1
14
LOCATION
17.27
0.680
9
17.45
0.675
TERMINAL
20.06
0.790
4 3
2 1 0.170
LOCATION
11
14
12
4.32 DIA.
A2
13
TYP. 2 1
0.165 5
2.03
0.080
69.09
2.720
1.560 4.19
67.81
2.67 REF
1
31.75
1.250
39.62
1.820
46.22
65.99
2.598
14 13 8 7
28.95
1.140
8 7
32.99
1.299
6 5
9
17.01
0.670
6 5
1.178 0.653
1.390 29.92 16.59
35.30 0.995
2.637 25.27
66.97 2.875
73.02
69.6
2.74
65.5
2.58
69.6
2.74
47.0
1.85
4.1
0.16
4.11
0.16
65.5
2.58
1
36.8
1.45
1
36.8
1.45
1 1
1 0 4 3
7
11 10 1 1 1 14 13
9 8 2 9
1 0
9 8 7 12 11 10 9
TOP VIEW
1.27 0.653 1.63 TOP VIEW
32.3 16.59 0.653
1.44 1.09 1.83 41.4 16.59
36.6 1.59 27.7 46.5 1.98 1.09
40.4 50.3 27.7
13
2003-2008 Schneider Electric 08/2008
All Rights Reserved
Type C Power Relays
Application Data, Dimensions, Order Information
Class 8501 Type C relays are ideally suited for controlling small
single phase motors and other light loads such as electric
heaters, pilot lights or audible signals.
8501CDO6V51
30 Ampere Contact Rating CE Approved
Horsepower Rated Visible Contacts
UL Listed Low Cost
CSA Certified
Selection Table AC Rated Contacts Application Data AC Contact Ratings Application Data Coil Burden
Number AC DC
Maximum Nominal
of Operated Operated Maximum Resistive Ampere Rating Nominal
Contact Single Phase DC
Fixed Coil Coil Contact 75% Power Factor Power
Arrangement Horsepower Burden
Contacts Open Type Open Type Voltage (VAC Coil)
(VDC Coil)
N.O. N.C. Type Type 300V 600V 120V 230V 600V
SPST 1 0 CO6 CDO6 600 30 10 2 2 2 10VA 2W
DPST 2 0 CO7 CDO7 600 30 5 11/2 11/2 11/2 10VA 2W
SPST 0 1 CO8 CDO8 600 30 10 2 2 2 10VA 2W
SPDT 1 1 CO15 CDO15 600 30 5 11/2 11/2 11/2 10VA 2W
DPDT 2 2 CO16 CDO16 600 30 5 11/2 11/2 11/2 10VA 2W
Selection Table DC Rated Contacts Application Data DC Contact Ratings Application Data Coil Burden
110V 220V
SPST 1 0 CO21 CDO21 500 20 8 10VA 2W
N.A.
DPDT 2 2 CO22 CDO22 325 10 4 10VA 2W
Voltage code must be specified to order this product. Refer to standard voltage codes listed in the Stocked Relays table below and insert as shown in How to Order.
Enclosure:
Dimensions
Separately packed NEMA Type 1 sheet steel enclosure for Catalog A B C D E F
Types CO & CDO relays order Class 9991 Type UE1 Number
IN mm IN mm IN mm IN mm IN mm IN mm
8501
CO6, CO7, CO8,
Operating Data CDO6, CDO7, 2.43 61.7 2.50 63.5 0.31 8.0 0.81 20.6 2.25 57.2 0.38 9.5
CDO8
Operating Voltages/ AC 6 through 480 volts, + 10/-15% of nominal at 25C CO15, CO21,
DC 6 through 110 volts, + 10/-20% of nominal at 25C 2.43 61.7 2.50 63.5 0.31 8.0 0.81 20.6 2.18 55.4 0.38 9.5
Voltage Range CDO15, CDO21
Coil Inrush (VAC Coil) 15VA CO16,CDO16 3.12 79.2 2.50 63.5 0.31 8.0 1.5 38.1 2.31 58.7 0.38 9.5
CO22, CDO22 3.12 79.2 2.50 63.5 0.31 8.0 1.5 38.1 2.53 64.3 0.38 9.5
Coils Duty: Continuous rated coils. (Non-replaceable)
How to Order:
To Order Specify: Catalog Number
Class Number Class Type Voltage Code
Type Number
8501 CO6 V20
Voltage Code
(See Stocked Relay Table above)
14
2003-2008 Schneider Electric 08/2008
All Rights Reserved
Type C Power Relays
Application Data, Dimensions, Order Information
15
2003-2008 Schneider Electric 08/2008
All Rights Reserved
Schneider Electric USA Schneider Electric Canada
8001 Knightdale Blvd. 19 Waterman Avenue,
Knightdale, NC 27545 M4B 1 Y2
1-888-SquareD Toronto, Ontario
(1-888-778-2733) 1-800-565-6699 8501CT0301R7/08 2003-2008 Schneider Electric All Rights Reserved
www.schneider-electric.us www.schneider-electric.ca Replaces 8501CT0301, December 2003
08/2008