Sunteți pe pagina 1din 4

B200 Beton clasic de antier.

Agregat de ru
C 140/86: BC 15 L 3 Pa 35/031-II
NE 012/99: C 12/15 T 3 II/A s 32.5 R/0-31
A = 185 l/m3 Ag = 1890 Kg/m3 N0.2-3 = 756 Kg/m3
A/C = 0.65 b = 2360 Kg/m3 N3-7 = 378 Kg/m3
C = A/A/C = 185/0.65 = 285 Kg/m3 P7-16 = 378 Kg/m3
P16-31 = 378 Kg/m3
C 285
Ag ag 1000 A P 2.71000 185 20 1890 Kg / m 3
c 3.0

Pentru: C = 285 Kg/m3 Zona a II-a de granulozitate recomandat


T3

P3 = 40%; P7 = 60%; P16 = 80%; P31 = 100%
Pe sorturi
N0.2-3 = 40/100 1890 = 756 Kg/m3
N3-7 = 60 - 40/100 1890 = 378 Kg/m3
P7-16 = 80 - 60/100 1890 = 378 Kg/m3
P16-31 = 100 - 80/100 1890 = 378 Kg/m3

B250
C 140/86: BC 20 L 3 Pa 35/031-II
NE 012/99: C 16/20 T 3 II/A s 32.5 R/0-31
A = 185 l/m3 Ag = 1844 Kg/m3 N0.2-3 = 553 Kg/m3
A/C = 0.55 b = 2365 Kg/m3 N3-7 = 369 Kg/m3
C = A/A/C = 185/0.55 = 336 Kg/m3 P7-16 = 369 Kg/m3
P16-31 = 553 Kg/m3
336
Ag 2.7 1000 185 20 1844 Kg / m 3
3
Pentru: C = 336 Kg/m3 Zona a III-a de granulozitate recomandat
T3

P3 = 30%; P7 = 50%; P16 = 70%; P31 = 100%
Pe sorturi
N0.2-3 = 30/100 1844 = 553 Kg/m3
N3-7 = 50 - 30/100 1844 = 369 Kg/m3
P7-16 = 70 - 50/100 1844 = 369 Kg/m3
P16-31 = 100 - 70/100 1844 = 553 Kg/m3

B300 Bc 22.5 C 18/22.5 n normele europene nu se regsate aceast clas.


Chiar i C 140/86 adopt Bc 22.5 doar pentru echivalarea cu marca B300.
C 140/86: BC 22.5 L 3 Pa 35/031-II
NE 012/99: C 18/22.5 T 3 II/A s 32.5 R/0-31
A = 185 l/m3 Ag = 1832 Kg/m3 N0.2-3 = 550 Kg/m3
A/C = 0.53 b = 2366 Kg/m3 N3-7 = 366 Kg/m3
C = A/A/C = 185/0.53 = 349 Kg/m3 P7-16 = 366 Kg/m3
P16-31 = 550 Kg/m3
349
Ag 2.7 1000 185 20 1832Kg / m 3
3
Pentru: C = 349 Kg/m3 Zona a III-a de granulozitate recomandat
T3

P3 = 30%; P7 = 50%; P16 = 70%; P31 = 100%
Pe sorturi
N0.2-3 = 30/100 1832 = 550 Kg/m3
N3-7 = 50 - 30/100 1832 = 366 Kg/m3
P7-16 = 70 - 50/100 1832 = 366 Kg/m3
P16-31 = 100 - 70/100 1832 = 550 Kg/m3

B300 Bc 25 C 20/25 Clasa Bc 25 se accept c echivaleaz marca B350 (cu


avizul proiectantului) dar n realitate echivaleaz marca veche B330.
C 140/86: BC 25 L 3 Pa 35/031-II
NE 012/99: C 20/25 T 3 II/A s 32.5 R/0-31
A = 185 l/m3 Ag = 1814 Kg/m3 N0.2-3 = 544 Kg/m3
A/C = 0.50 b = 2369 Kg/m3 N3-7 = 363 Kg/m3
C = A/A/C = 185/0.50 = 370 Kg/m3 P7-16 = 363 Kg/m3
P16-31 = 544 Kg/m3
370
Ag 2.7 1000 185 20 1814 Kg / m 3
3
Pentru: C = 370 Kg/m3 Zona a III-a de granulozitate recomandat
T3

P3 = 30%; P7 = 50%; P16 = 70%; P31 = 100%
Pe sorturi
N0.2-3 = 30/100 1814 = 544 Kg/m3
N3-7 = 50 - 30/100 1814 = 363 Kg/m3
P7-16 = 70 - 50/100 1814 = 363 Kg/m3
P16-31 = 100 - 70/100 1814 = 544 Kg/m3

B250 16 Diametrul agregatului max. (ochi ciur).


C 140/86: BC 20 L 3 Pa 35/016-II
NE 012/99: C 16/20 T 3 II/A s 32.5 R/0-16
A = 185 + 0.1 185 = 203.5 l/m3 Ag = 1737 Kg/m3 N0.2-3 = 695 Kg/m3
A/C = 0.55 b = 2310 Kg/m3 N3-7 = 347 Kg/m3
C = A/A/C = 203.5/0.55 = 370 Kg/m3 P7-16 = 695 Kg/m3
370
Ag 2.7 1000 203.5 30 1737 Kg / m 3
3
Pentru: C = 370 Kg/m3 Zona a III-a de granulozitate recomandat
T3

P3 = 40%; P7 = 60%; P16 = 100%
Pe sorturi
N0.2-3 = 40/100 1737 = 695 Kg/m3
N3-7 = 60 - 40/100 1737 = 347 Kg/m3
P7-16 = 100 - 60/100 1737 = 695 Kg/m3

Compoziiile etalon (de baz) au fost calculate n urmtoarele ipoteze i date:


agregat de ru perfect uscat;
gradul II de omogenitate (preparare n staie semiautomat:
dac se prepar normal (gr.III omogenitate) valoarea raportului A/C crete cu 0.05;
dac betonul se trateaz termic gr.II devine gr.III, deci valoarea raportului A/C se
reduce cu 0.05 (atenie: se coreleaz i cu modul de preparare: gr.I gr.II, gr.II
gr.III).
L3 T3 (tasare 80 20 mm C 140/86; tasare 70 20 mm NE 012/99);
Pa 35 II/A s 32.5 R ciment compozit etalon n Romnia STAS 1500/78 sau SR
1500/96; MPZ 400 pe vechi (nainte de 1969);
nu se pune nici o condiie de permeabilitate i gelivitate (dac s-ar pune, se limiteaz
valoarea raportului A/C la cifre precise: A/C 0.6 P 4 10; A/C 0.5 P8 10; A/C
0.45 P12 10;
nu am comparat dozajul de ciment minim cu dozajul calculat pentru condiii foarte severe.
Pentru condiii normale i moderate Cmin 250 270 Kg/m3.