Complete System Ordering Information

System Total Step No. of Nominal Nominal Reactors Network Group Cable Cable
Type Power Size Groups Voltage Frequency Percentage Typology Protection Connection Entry
EQ 1440 : 120 : 12 - 400 . 50 - P7 - W F C A

System Type
Total Power
EQ Equalizer Complete System
Total power in kVAr
Real-time power quality enhancement system:
Step Size
No. of Groups
Step size in kVAr (Switching Resolution)
Number of Groups (Physical, max. 12)
Power factor correction, energy savings,
Nominal Voltage
Nominal Frequency
Nominal Phase-to-Phase Voltage in Volts
Nominal Frequency in Hz (50 or 60 Hz)
voltage support, flicker reduction, current spike
Reactors Percentage
P0
P#
Inrush Limiting Reactors Only
Percents of Capacity. Example: P7 = 7%.
reduction, harmonic filtration and many other
D
W
Delta 3 wires
Wye 4 wires
applications for a variety of dynamic loads.
Network Typology
V Wye 3 wires
S Single phase
F Groups protected by Fuses
Group Protection
M Groups protected by MCCBs
C Single Point with Integral Circuit Breaker
Cable Connection S Single Connection Point
M Multiple Connection Points
T Top Cable Entry
B Bottom Cable Entry
Cable Entry A Top and Bottom Cable Entry
L Left-side Cable Entry
R Right-side Cable Entry

Example:
EQ 300:60:3-400.50-P7-WFSA
300kVAr real-time complete Equalizer system with 5 steps of 60 kVAr with 7%
inductors, for 400V/50Hz 4-wires Wye network.
Dimensions (W*D*H): 800*600*2100, Short Circuit 35kA, IP 20

Controller Ordering Information


Controller Type Measurement Level No. of Groups Comm. Card Power Supply Special Type
EQC 3 12 2 - 2 WT

Controller Type EQC Equalizer Controller


2
Measurement Level
3
No. of Groups Number of Groups (Physical, two digits, max. 12)
0 No Communication
Communication Card 1 RS 485 ELCOM Protocol
2 RS 485 ELCOM and MODBUS/RTU Protocols
1 115V
Power Supply
2 230V
See Controller section on previous pages
Special Type
Up to two types can be combined

Measured Parameters
Measurement Level
Parameter Phases Loads
2 3
Frequency Common Mains £ £
Phase Current L1, L2, L3 Mains,Load,Cap. £ £
Neutral Current Neutral Mains £ £
Phase to Phase Current* L1-2, L2-3, L3-1 Mains , Load £ £
Phase Voltage L1, L2, L3 Mains £ £
Neutral Voltage Neutral Mains £ £
Phase to Phase Voltage L1-2, L2-3, L3-1 Mains
ELSPEC Ltd. Active Power (kW) L1, L2, L3, Total Mains
£

£
£

£
Reactive Power (kVAr) L1, L2, L3, Total Mains,Load,Cap.
P. O. Box 3019, Apparent Power (kVA) L1, L2, L3, Total Mains,Load,Cap.
£
£
£
£

4 HaShoham St., Zone 23 Power Factor L1, L2, L3, Total Mains,Load,Cap. £ £

Time of use (TOU) - in, out, net, total:


C a e s a r e a I n d u s t r i a l Pa r k , Active Energy (kWh) Total Mains £ £
38900, ISRAEL Reactive Energy (kVARh) Total Mains £ £

THD at Phase Current L1, L2, L3 Mains,Load,Cap.


Tel: +972-4-6272-470 THD at Neutral Current Neutral Mains
£
£
£
£

Fax: +972-4-6272-465 THD at Phase to Phase Current L1-2, L2-3, L3-1 Mains , Load £ £
THD at Phase Voltage L1, L2, L3 Mains £ £
E-Mail: info@elspec-ltd.com THD at Neutral Voltage Neutral Mains £ £
THD at Phase to Phase Voltage L1-2, L2-3, L3-1 Mains £ £

Harmonics of Phase Current L1, L2, L3 Mains,Load,Cap.


Specifications are subject to Harmonics of Neutral Current Neutral Mains
£
£
Harmonics of Phase to Phase Current L1-2, L2-3, L3-1 Mains , Load
change without notification. Harmonics of Phase Voltage L1, L2, L3 Mains
£
£

All trademarks are the Harmonics of Neutral Voltage


Harmonics of Phase to Phase Voltage
Neutral
L1-2, L2-3, L3-1
Mains
Mains
£
£

property of their respective Waveforms of Phase Current L1, L2, L3 Mains,Load,Cap. £


Waveforms of Neutral Current Neutral Mains £
owners. Waveforms of Phase to Phase Current L1-2, L2-3, L3-1 Mains £
Waveforms of Phase Voltage L1, L2, L3 Mains
Copyright ELSPEC Waveforms of Neutral Voltage Neutral Mains
£
£
Waveforms of Phase to Phase Voltage L1-2, L2-3, L3-1 Mains
Engineering Ltd. 2004 System Log £
£

£
Event Log £ £

w w w. e l s p e c - l t d . c o m * Unique feature: metering internal current of feeder transformer (delta secondary)


P o w e r
EQUALIZER Technology The EQUALIZER Power Quality Solution
Definition
Capacitor Group Switching L1 L2 L3 L1 L2 L3 Power Quality is a term used to define any occurrence of voltage, current or frequency deviation that results in equipment failure,
The EQUALIZER switches capacitor groups process interruptions or power system inefficiency. These deviations can manifest themselves in harmonics, power factor, voltage
on and off using state-of-the-art electronic sags/swells, voltage flickering, transients and many other forms. The EQUALIZER from Elspec is an all-in-one solution for power
switches. The connection and disconnection quality problems, typically installed near the main service and near major distribution panels.
of capacitors occur precisely at zero-current
crossing. This smooth connection avoids Voltage Sags (Voltage Drops, Under-Voltage) Harmonics (non-linear loads)
transient effects typically created by Voltage sags, also known as voltage drops or under-voltage, High harmonic voltages and currents cause significant energy
electromechanically switched power factor are caused by local loads, either during motor startup or losses, overheating and dramatically increase site vulnerability
correction (PFC) systems, extending the life from rapidly changing loads. This condition is characterized to failures and fire. More details on harmonics appear under
expectancy of the EQUALIZER dramatically. by low power factor and high reactive energy demand. the applications section on next page.
The Elspec EQUALIZER’s ultra-fast technology is designed
2- and 3-Phase Switching Structure Electromechanical vs. to act in these specialized conditions. It connects all Spikes (Transients)
3 groups
Transient-free Switching required capacitor banks in 2/3 cycle typical (1/4 - 1 cycle Spikes (transients) can cause significant damage to equipment,
Groups are always engaged max.), compensating for the total reactive energy of the produce unpredicted power supply failures and degrade
event. Moreover, it changes the direction of the voltage capacitors. The EQUALIZER solution uses transient-free
SCAN Mode drop vector to minimize the sag. As a result, the voltage switching technology to eliminate all spikes associated with
6
The EQUALIZER is equipped with a unique SCAN feature that sag is minimized and in many cases, even eliminated (See conventional capacitor switching. The results are longer

Q u a l i t y
5
protects capacitors from exploding and contributes to longer life Motor Startup and Elevator application notes on next page). capacitor life expectancy, less maintenance costs and higher
expectancy by reducing over-current and minimizing capacitor network reliability.
4
heating. The electronic switching element (unlimited operations) Voltage Flickering
Each group connects one capacitor group simultaneously as another group is Voltage flickering is caused by fast voltage fluctuations Service Utilization
3
is engaged disconnected. This operation occurs every few seconds, engaging commonly associated with rapid loads, such as spot Higher service utilization is a constant wish of all electricity
50% of each capacitor group in turn, with total compensation unchanged. welders. The EQUALIZER’s control technology connects users, whether the power is provided by the utility, generators
the time
2 This results in mean current reduction due to lower duty cycle and disconnects all required capacitor banks in 2/3 cycle or other local generation such as wind turbines. Employing
(engagement time to cycle time). Together with the unique reactor typical (1/4 - 1 cycle max.), effectively reducing the flicker the EQUALIZER may dramatically increase the existing service
1 design, temperature rise of the reactors is substantially reduced to acceptable levels (See Spot Welding application note). utilization by reducing the average current and stabilizing
and the potential for cabinet overheating is minimized. current fluctuations. Existing installations show service
1 2 3 4 5 6 Time
Power Factor utilization increases of up to 60% (See Generator application
SCAN Mode
In many cases, low power factors result in higher utility note).
bills through penalties and increased demand charges.
Consistent Capacity Ideal PFC Control They also cause system energy losses, overheating, increased Voltage Control
Conventional electromechanical Using exclusive automatic control maintenance costs and low service utilization. The Elspec In addition to power factor and other power quality issues, at
capacitor banks suffer from an ongoing algorithms and rapid electronic EQUALIZER is the foremost solution for low power factor, times there is a need to maintain voltage levels within certain
cumulative reduction in capacity due switching, total acquisition time preventing utility penalties, saving energy, reducing limits due to sensitive equipment or other facility requirements.
to the effect of transients during (complete compensation of reactive maintenance costs and increasing service utilization. The EQUALIZER voltage control option offers 6 different
connection and disconnection. This current) is achieved in 2/3 cycle typical voltage control levels that facilitate both high and low
can be especially detrimental in tuned (1/4 - 1 cycle max.; 50Hz = 13.3 ms; parameters. The voltage control operates in parallel with the
and detuned electromechanically 60Hz = 11.1 ms), irrespective of the power factor control and complements it.
switched systems where changes in number of steps required.
the ratio between the capacitors and The power factor is controlled very
reactors shift the resonant frequency. accurately through an advanced open

S o l u t i o n s
This scenario can cause resonance, and closed-loop control & measuring
which can cause extreme damage to system that uses information from all Power Factor Compensation – A Comparison
equipment in the facility. The three phases, as well as accounts for the The EQUALIZER is an ideal solution for power quality applications. Regardless of the application, the EQUALIZER solution
EQUALIZER prevents this scenario, effect of harmonics (1 through 63). achieves near-perfect power factor control, network stabilization and energy savings.
resulting in longer system life, lower Minimum, maximum and average power
maintenance costs and more consistent factor modes, as well as threshold levels, In many cases, the EQUALIZER is Adverse effects of slower response
harmonic filtration over time. The Controller can be selected for perfect compliance the only proper solution. 1.0 systems
with specific network requirements. Implementing slow-response power Load Current The bottom graphs demonstrate incorrect
Fast and Accurate Measurements The EQUALIZER includes a unique factor compensation or even quasi- compensation where response time is 3
The EQUALIZER controller uses FFT (Fast Fourier Transform) analysis of all phases solution for line-to-line loads, in which real-time systems in these 0 2 4 6 8 10 12 14 16 18 20 22 24 Cycles
cycles to connect a single group and
each cycle. Power information, system status and detailed logs of events are displayed it calculates a transformer’s internal applications would actually reduce Equalizer Current
acquisition time required to connect a
on a large backlit graphic LCD screen, or via communication using the user-friendly currents and compensates accordingly. power quality and possibly produce
1.0
total of 4 groups is 12 cycles. Due to
PowerIQ software. Third party measurements have proven wasted energy. The following the delay in connections, the current is
the EQUALIZER to be the ultimate example compares the results of only partially reduced. Further, the
Acquisition Time
solution to offer precise compensation the EQUALIZER (2/3 cycle typical, corresponding delay in disconnection
for voltage drop and flickering. 1/4 - 1 cycle max.) with a quasi- 1.0 causes residual current. The overall effect
real-time solution (1 step / 3 cycles): Total Current with Equalizer Correct
of this compensation system on total
compensation current is negative, as the average current
Correct compensation using the of the load is increased, rather than
Equalizer 1.0
Current of slow response system
(3 cycles per step)
decreased. This phenomena will increase
The top graphs demonstrate the voltage flickering due to
EQUALIZER’s compensation of the overcompensation.
reactive current in a 14-cycle energy Acquisition Time
PowerIQ Measurement & load. Typical acquisition time ( full
Analysis Software (optional) compensation of reactive current) 1.0
0.6
This Windows-based software is less than one cycle and total 0.2
Total Current with slow
response system
can display the system's status, current is substantially reduced.
measurement results and 1 Group Incorrect
compensation
real-time data. Switching Module
P o w e r
EQUALIZER Technology The EQUALIZER Power Quality Solution
Definition
Capacitor Group Switching L1 L2 L3 L1 L2 L3 Power Quality is a term used to define any occurrence of voltage, current or frequency deviation that results in equipment failure,
The EQUALIZER switches capacitor groups process interruptions or power system inefficiency. These deviations can manifest themselves in harmonics, power factor, voltage
on and off using state-of-the-art electronic sags/swells, voltage flickering, transients and many other forms. The EQUALIZER from Elspec is an all-in-one solution for power
switches. The connection and disconnection quality problems, typically installed near the main service and near major distribution panels.
of capacitors occur precisely at zero-current
crossing. This smooth connection avoids Voltage Sags (Voltage Drops, Under-Voltage) Harmonics (non-linear loads)
transient effects typically created by Voltage sags, also known as voltage drops or under-voltage, High harmonic voltages and currents cause significant energy
electromechanically switched power factor are caused by local loads, either during motor startup or losses, overheating and dramatically increase site vulnerability
correction (PFC) systems, extending the life from rapidly changing loads. This condition is characterized to failures and fire. More details on harmonics appear under
expectancy of the EQUALIZER dramatically. by low power factor and high reactive energy demand. the applications section on next page.
The Elspec EQUALIZER’s ultra-fast technology is designed
2- and 3-Phase Switching Structure Electromechanical vs. to act in these specialized conditions. It connects all Spikes (Transients)
3 groups
Transient-free Switching required capacitor banks in 2/3 cycle typical (1/4 - 1 cycle Spikes (transients) can cause significant damage to equipment,
Groups are always engaged max.), compensating for the total reactive energy of the produce unpredicted power supply failures and degrade
event. Moreover, it changes the direction of the voltage capacitors. The EQUALIZER solution uses transient-free
SCAN Mode drop vector to minimize the sag. As a result, the voltage switching technology to eliminate all spikes associated with
6
The EQUALIZER is equipped with a unique SCAN feature that sag is minimized and in many cases, even eliminated (See conventional capacitor switching. The results are longer

Q u a l i t y
5
protects capacitors from exploding and contributes to longer life Motor Startup and Elevator application notes on next page). capacitor life expectancy, less maintenance costs and higher
expectancy by reducing over-current and minimizing capacitor network reliability.
4
heating. The electronic switching element (unlimited operations) Voltage Flickering
Each group connects one capacitor group simultaneously as another group is Voltage flickering is caused by fast voltage fluctuations Service Utilization
3
is engaged disconnected. This operation occurs every few seconds, engaging commonly associated with rapid loads, such as spot Higher service utilization is a constant wish of all electricity
50% of each capacitor group in turn, with total compensation unchanged. welders. The EQUALIZER’s control technology connects users, whether the power is provided by the utility, generators
the time
2 This results in mean current reduction due to lower duty cycle and disconnects all required capacitor banks in 2/3 cycle or other local generation such as wind turbines. Employing
(engagement time to cycle time). Together with the unique reactor typical (1/4 - 1 cycle max.), effectively reducing the flicker the EQUALIZER may dramatically increase the existing service
1 design, temperature rise of the reactors is substantially reduced to acceptable levels (See Spot Welding application note). utilization by reducing the average current and stabilizing
and the potential for cabinet overheating is minimized. current fluctuations. Existing installations show service
1 2 3 4 5 6 Time
Power Factor utilization increases of up to 60% (See Generator application
SCAN Mode
In many cases, low power factors result in higher utility note).
bills through penalties and increased demand charges.
Consistent Capacity Ideal PFC Control They also cause system energy losses, overheating, increased Voltage Control
Conventional electromechanical Using exclusive automatic control maintenance costs and low service utilization. The Elspec In addition to power factor and other power quality issues, at
capacitor banks suffer from an ongoing algorithms and rapid electronic EQUALIZER is the foremost solution for low power factor, times there is a need to maintain voltage levels within certain
cumulative reduction in capacity due switching, total acquisition time preventing utility penalties, saving energy, reducing limits due to sensitive equipment or other facility requirements.
to the effect of transients during (complete compensation of reactive maintenance costs and increasing service utilization. The EQUALIZER voltage control option offers 6 different
connection and disconnection. This current) is achieved in 2/3 cycle typical voltage control levels that facilitate both high and low
can be especially detrimental in tuned (1/4 - 1 cycle max.; 50Hz = 13.3 ms; parameters. The voltage control operates in parallel with the
and detuned electromechanically 60Hz = 11.1 ms), irrespective of the power factor control and complements it.
switched systems where changes in number of steps required.
the ratio between the capacitors and The power factor is controlled very
reactors shift the resonant frequency. accurately through an advanced open

S o l u t i o n s
This scenario can cause resonance, and closed-loop control & measuring
which can cause extreme damage to system that uses information from all Power Factor Compensation – A Comparison
equipment in the facility. The three phases, as well as accounts for the The EQUALIZER is an ideal solution for power quality applications. Regardless of the application, the EQUALIZER solution
EQUALIZER prevents this scenario, effect of harmonics (1 through 63). achieves near-perfect power factor control, network stabilization and energy savings.
resulting in longer system life, lower Minimum, maximum and average power
maintenance costs and more consistent factor modes, as well as threshold levels, In many cases, the EQUALIZER is Adverse effects of slower response
harmonic filtration over time. The Controller can be selected for perfect compliance the only proper solution. 1.0 systems
with specific network requirements. Implementing slow-response power Load Current The bottom graphs demonstrate incorrect
Fast and Accurate Measurements The EQUALIZER includes a unique factor compensation or even quasi- compensation where response time is 3
The EQUALIZER controller uses FFT (Fast Fourier Transform) analysis of all phases solution for line-to-line loads, in which real-time systems in these 0 2 4 6 8 10 12 14 16 18 20 22 24 Cycles
cycles to connect a single group and
each cycle. Power information, system status and detailed logs of events are displayed it calculates a transformer’s internal applications would actually reduce Equalizer Current
acquisition time required to connect a
on a large backlit graphic LCD screen, or via communication using the user-friendly currents and compensates accordingly. power quality and possibly produce
1.0
total of 4 groups is 12 cycles. Due to
PowerIQ software. Third party measurements have proven wasted energy. The following the delay in connections, the current is
the EQUALIZER to be the ultimate example compares the results of only partially reduced. Further, the
Acquisition Time
solution to offer precise compensation the EQUALIZER (2/3 cycle typical, corresponding delay in disconnection
for voltage drop and flickering. 1/4 - 1 cycle max.) with a quasi- 1.0 causes residual current. The overall effect
real-time solution (1 step / 3 cycles): Total Current with Equalizer Correct
of this compensation system on total
compensation current is negative, as the average current
Correct compensation using the of the load is increased, rather than
Equalizer 1.0
Current of slow response system
(3 cycles per step)
decreased. This phenomena will increase
The top graphs demonstrate the voltage flickering due to
EQUALIZER’s compensation of the overcompensation.
reactive current in a 14-cycle energy Acquisition Time
PowerIQ Measurement & load. Typical acquisition time ( full
Analysis Software (optional) compensation of reactive current) 1.0
0.6
This Windows-based software is less than one cycle and total 0.2
Total Current with slow
response system
can display the system's status, current is substantially reduced.
measurement results and 1 Group Incorrect
compensation
real-time data. Switching Module
P o w e r
Applications Applications (cont.)

Voltage (V)
Welding Machines 230
Harmonics Filtration
Spot welding loads fluctuate extremely rapidly and consume large amounts of 220
Utilities generate an almost perfect sinusoidal voltage. Harmonics, created by
reactive power. Due to high current changes caused by the near-instantaneous 210
1800 Without With nonlinear loads such as variable speed drives, power rectifiers, inverters etc.,

Current (A)
reactive energy consumption, large voltage drops are produced. These sags cause nonlinear voltage drops and change the sinusoidal nature of the voltage. C1 CN
Source
reduce weld quality and decrease welding productivity. Additionally, these loads When reactive energy is compensated using capacitors, there is a frequency
1400
Impedance -
Harmonics
often create a high incidence of voltage flickering, which frequently exceeds 1000
at which the capacitors are in parallel resonance with the power source (high L1
L2 L2N
Source

Q (kVAr)
300

recommended IEEE limits. Elspec’s real-time EQUALIZER benefits: 150 impedance). If the resonant frequency occurs in proximity to one of the harmonic
•Improved weld quality and reduced scrap/rework 0
sources, current can circulate between the supply and the capacitors, resulting
•Increased process output Time [2 sec./Div]
in high voltage on the line. In this scenario, current levels may exceed the
•Reduced voltage flickering Spot Welding - Car Industry capacitor’s rated current by more than two or three times, and can cause Harmonic Polluted Network
•Enhanced service utilization for the facility 11800 trasformer burn.
(better utilization of the existing power infrastructure) 11600 Resonance can occur on any frequency, however in most cases, current harmonic k

•Reduced maintenance costs 11400


sources exist at the 5th, 7th, 11th, and 13th harmonic. The EQUALIZER's 10 with without
The top graph on the right demonstrates how the EQUALIZER prevents voltage With Without custom-designed reactors, used in series with the capacitors, prevent resonance 8
reactors reactors

drop and flickering, substantially reduces the current and fully compensates 11200
by shifting the capacitor/ network resonance frequency below the first dominant

Amps
6
reactive energy requirements. The bottom graph on the right illustrates welder 11000
harmonic (usually 5th).
tips DC current with and without the EQUALIZER solution. Optimal welding

Q u a l i t y
10800 Tuned Equalizer vs. Active Harmonic Filters 4

conditions require a stable current at the weld tips. In this example, current 10600 Active filters connect power to the network with an amplitude opposite that 2

variations are reduced 33% with the EQUALIZER solution (±1200A vs. ±1800A). 10400
of the harmonics. Active filter technology is an expensive solution, and inherently 1 2 3 4 5 6 7 n
1 2 3 4 5 6 7 8 9 10 increases system losses. In applications having one or two dominant harmonics,
Spot Number
a harmonic tuned Elspec EQUALIZER is the right technical and economic Shifting resonance frequency below the 5th harmonic
DC Current at Welder Tip
Voltage (V)

230

220
choice, effectively minimizing system losses and reducing overall THD (Total
Harmonic Distortion). 10%
210
1500
Motor Start-up 9%
Without With
With Without When connected directly to the line, large squirrel-case Electric Trains 8%

inductive motors consume very high current during the Electric rail lines have long power distribution systems and rapid load changes,
7%
Current (A)

6%

1000 start-up period (six times higher than steady state operation). leading to substantial voltage drops and voltage flickering. The Elspec EQUALIZER 5%

This high current consumption can lead to significant system: 4%

voltage drops on both the low and high voltage sides of •Provides voltage support to the distribution network
3%

2%
500 the transformer, which interfere with other loads, reduce •Stabilizes network power 1%

Time [0.2 sec./Div] initial torque and increase start-up time. The EQUALIZER •Prevents low power factor penalties 0%
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 THD

system tracks the reactive current and fully compensates •Minimizes system losses and maintenance costs Voltage Harmonic Filtration Example
AC Motor Startup it in 2/3 cycle typical (1/4 - 1 cycle max.), offering the •Increases network loading capabilities
following benefits:
Plastic Injection Molding •Protection against voltage drop on the main service Hospitals, High-rises and Other Commercial Buildings (elevators, air Generators (emergency stand-by, parallel
Due to widely varying unsynchronized load conditions, plastic •Capability to central-start all loads, avoiding the use of conditioning, critical loads) and stand-alone operation)
injection molding applications have rapid & inconsistent reactive •individual starters commonly used to protect against Most commercial buildings have significant load variations caused by elevators, Use of generators for local power generation
energy requirements. Power supply failure during a production •voltage drop air conditioninig equipment and other rapidly changing loads. Further, today’s for normal facility operations and emergency
cycle can cause enormous financial and physical damage caused •Direct connection of motors to main service, obtaining medical equipment, computers and other sensitive loads can be damaged by back-up have become much more prevalent
by plastic cooling inside the machines. Besides reducing overall •maximum torque during start-ups. This benefit is unique spikes caused by conventional capacitor systems. The EQUALIZER: in recent years. All types of generators can
system energy losses, Elspec’s EQUALIZER solution drastically •to the EQUALIZER solution, as starters of all types •Stabilizes the facility load benefit from power factor compensation

S o l u t i o n s
reduces the risk for such an event by stabilizing the current and •typically reduce the current going through the motor, •Eliminates spikes caused by capacitor switching provided by the EQUALIZER. Further, the
voltage levels in the facility on a cycle-by-cycle basis. •thereby reducing the starting torque. •Increases life expectancy of sensitive equipment EQUALIZER is the only power factor correction
•Reduces maintenance costs equipment approved for connection by
Harbor Cranes •Increases available power for new generator manufacturers.
The complete operation cycle of harbor cranes is approximately •loads on existing infrastructure The Elspec Equalizer:
one minute. During this time, the crane requires variable • Increases useable power
amounts of reactive energy, fluctuating rapidly throughout • Allows separate target power factor
the entire crane cycle. programming, dependent on generator
The Elspec EQUALIZER’s real-time solution: operational mode, when specified with
•Stabilizes the voltage generator option
•Reduces the current • Potentially increases financial savings when
•Allows installation of a smaller multiple generator systems are used in tandem
•service (less cable, less heat) • Enables downsizing of new generator
•Lowers system losses installations
•Saves energy

Other Industrial Loads


Wind Energy The Elspec EQUALIZER is successfully
Wind turbine generators have become a significant contributor to power installed in thousands of sites with other
generation throughout the world. As a result, utility regulations for wind turbines applications that due to space limitation were
have become more constrained, and now require stable voltage, reactive energy not described in this catalog. The
supply to the network and voltage control to support network failures. The EQUALIZER can benefit all users, regardless
Elspec EQUALIZER-W is specifically engineered for the wind energy market, of their specific application, to save energy,
and features communication protocols that match its controller to the algorithms improve power quality, filter harmonics,
of leading wind turbine manufacturers worldwide. prevent voltage drops and much more.
P o w e r
Applications Applications (cont.)

Voltage (V)
Welding Machines 230
Harmonics Filtration
Spot welding loads fluctuate extremely rapidly and consume large amounts of 220
Utilities generate an almost perfect sinusoidal voltage. Harmonics, created by
reactive power. Due to high current changes caused by the near-instantaneous 210
1800 Without With nonlinear loads such as variable speed drives, power rectifiers, inverters etc.,

Current (A)
reactive energy consumption, large voltage drops are produced. These sags cause nonlinear voltage drops and change the sinusoidal nature of the voltage. C1 CN
Source
reduce weld quality and decrease welding productivity. Additionally, these loads When reactive energy is compensated using capacitors, there is a frequency
1400
Impedance -
Harmonics
often create a high incidence of voltage flickering, which frequently exceeds 1000
at which the capacitors are in parallel resonance with the power source (high L1
L2 L2N
Source

Q (kVAr)
300

recommended IEEE limits. Elspec’s real-time EQUALIZER benefits: 150 impedance). If the resonant frequency occurs in proximity to one of the harmonic
•Improved weld quality and reduced scrap/rework 0
sources, current can circulate between the supply and the capacitors, resulting
•Increased process output Time [2 sec./Div]
in high voltage on the line. In this scenario, current levels may exceed the
•Reduced voltage flickering Spot Welding - Car Industry capacitor’s rated current by more than two or three times, and can cause Harmonic Polluted Network
•Enhanced service utilization for the facility 11800 trasformer burn.
(better utilization of the existing power infrastructure) 11600 Resonance can occur on any frequency, however in most cases, current harmonic k

•Reduced maintenance costs 11400


sources exist at the 5th, 7th, 11th, and 13th harmonic. The EQUALIZER's 10 with without
The top graph on the right demonstrates how the EQUALIZER prevents voltage With Without custom-designed reactors, used in series with the capacitors, prevent resonance 8
reactors reactors

drop and flickering, substantially reduces the current and fully compensates 11200
by shifting the capacitor/ network resonance frequency below the first dominant

Amps
6
reactive energy requirements. The bottom graph on the right illustrates welder 11000
harmonic (usually 5th).
tips DC current with and without the EQUALIZER solution. Optimal welding

Q u a l i t y
10800 Tuned Equalizer vs. Active Harmonic Filters 4

conditions require a stable current at the weld tips. In this example, current 10600 Active filters connect power to the network with an amplitude opposite that 2

variations are reduced 33% with the EQUALIZER solution (±1200A vs. ±1800A). 10400
of the harmonics. Active filter technology is an expensive solution, and inherently 1 2 3 4 5 6 7 n
1 2 3 4 5 6 7 8 9 10 increases system losses. In applications having one or two dominant harmonics,
Spot Number
a harmonic tuned Elspec EQUALIZER is the right technical and economic Shifting resonance frequency below the 5th harmonic
DC Current at Welder Tip
Voltage (V)

230

220
choice, effectively minimizing system losses and reducing overall THD (Total
Harmonic Distortion). 10%
210
1500
Motor Start-up 9%
Without With
With Without When connected directly to the line, large squirrel-case Electric Trains 8%

inductive motors consume very high current during the Electric rail lines have long power distribution systems and rapid load changes,
7%
Current (A)

6%

1000 start-up period (six times higher than steady state operation). leading to substantial voltage drops and voltage flickering. The Elspec EQUALIZER 5%

This high current consumption can lead to significant system: 4%

voltage drops on both the low and high voltage sides of •Provides voltage support to the distribution network
3%

2%
500 the transformer, which interfere with other loads, reduce •Stabilizes network power 1%

Time [0.2 sec./Div] initial torque and increase start-up time. The EQUALIZER •Prevents low power factor penalties 0%
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 THD

system tracks the reactive current and fully compensates •Minimizes system losses and maintenance costs Voltage Harmonic Filtration Example
AC Motor Startup it in 2/3 cycle typical (1/4 - 1 cycle max.), offering the •Increases network loading capabilities
following benefits:
Plastic Injection Molding •Protection against voltage drop on the main service Hospitals, High-rises and Other Commercial Buildings (elevators, air Generators (emergency stand-by, parallel
Due to widely varying unsynchronized load conditions, plastic •Capability to central-start all loads, avoiding the use of conditioning, critical loads) and stand-alone operation)
injection molding applications have rapid & inconsistent reactive •individual starters commonly used to protect against Most commercial buildings have significant load variations caused by elevators, Use of generators for local power generation
energy requirements. Power supply failure during a production •voltage drop air conditioninig equipment and other rapidly changing loads. Further, today’s for normal facility operations and emergency
cycle can cause enormous financial and physical damage caused •Direct connection of motors to main service, obtaining medical equipment, computers and other sensitive loads can be damaged by back-up have become much more prevalent
by plastic cooling inside the machines. Besides reducing overall •maximum torque during start-ups. This benefit is unique spikes caused by conventional capacitor systems. The EQUALIZER: in recent years. All types of generators can
system energy losses, Elspec’s EQUALIZER solution drastically •to the EQUALIZER solution, as starters of all types •Stabilizes the facility load benefit from power factor compensation

S o l u t i o n s
reduces the risk for such an event by stabilizing the current and •typically reduce the current going through the motor, •Eliminates spikes caused by capacitor switching provided by the EQUALIZER. Further, the
voltage levels in the facility on a cycle-by-cycle basis. •thereby reducing the starting torque. •Increases life expectancy of sensitive equipment EQUALIZER is the only power factor correction
•Reduces maintenance costs equipment approved for connection by
Harbor Cranes •Increases available power for new generator manufacturers.
The complete operation cycle of harbor cranes is approximately •loads on existing infrastructure The Elspec Equalizer:
one minute. During this time, the crane requires variable • Increases useable power
amounts of reactive energy, fluctuating rapidly throughout • Allows separate target power factor
the entire crane cycle. programming, dependent on generator
The Elspec EQUALIZER’s real-time solution: operational mode, when specified with
•Stabilizes the voltage generator option
•Reduces the current • Potentially increases financial savings when
•Allows installation of a smaller multiple generator systems are used in tandem
•service (less cable, less heat) • Enables downsizing of new generator
•Lowers system losses installations
•Saves energy

Other Industrial Loads


Wind Energy The Elspec EQUALIZER is successfully
Wind turbine generators have become a significant contributor to power installed in thousands of sites with other
generation throughout the world. As a result, utility regulations for wind turbines applications that due to space limitation were
have become more constrained, and now require stable voltage, reactive energy not described in this catalog. The
supply to the network and voltage control to support network failures. The EQUALIZER can benefit all users, regardless
Elspec EQUALIZER-W is specifically engineered for the wind energy market, of their specific application, to save energy,
and features communication protocols that match its controller to the algorithms improve power quality, filter harmonics,
of leading wind turbine manufacturers worldwide. prevent voltage drops and much more.
P o w e r
The Controller System Structure
A digital signal processor (DSP) and a VLSI Switching Module Capacitor/Reactor Modules
component form the basis of the controller’s The switching module is comprised of Iron Core Reactors
technology. It features an LCD display, analog solid-state switching elements that Each Elspec EQUALIZER includes specially designed, iron core reactors
and digital circuitry, precise firing algorithms provide reliable, high-speed, transient- used in series with the capacitors. Each reactor is manufactured under
and optional communication capabilities. free operation. Single, double or three- tight control tolerances to ensure quality, constructed with a laminated,
The controller has 9 input channels: 4 voltages phase electronic switches, SCR/SCR or low-hysterisis loss iron core, copper windings, precision-controlled air
(for Wye networks), 3 main currents and 2 SCR/diode, are used for each capacitor gaps and Class H insulation (1800C).
internal system currents. The information group. Switching modules are
obtained from these measurements is used specifically selected for each EQUALIZER Available reactor types:
for Fast Fourier Transform (FFT) analysis, system based on the number of overall Inrush-only: Reactors designed to limit the inrush current which may
performed each network cycle on all Digits Display Waveform Display capacitor groups, current requirements develop in the capacitors during power up, avoiding damage to switching
channels. The advanced control algorithm, and voltage ratings. elements, fuses and capacitors
which includes unique patent-pending De-tuned: Prevent resonance condition by shifting the capacitor/network
technology for fast compensation, calculates resonant frequency to below the first dominant harmonic (usually the 5th)
the required compensation in 1ms. Further, Tuned: Designed to absorb a majority of the dominant harmonic(s), usually
harmonics are calculated on all phases, the 5th and/or 7th.
allowing the EQUALIZER to achieve ideal

Q u a l i t y
compensation even in the presence of Capacitors
harmonics. Elspec EQUALIZER features MKP-type capacitors that are low-loss
(0.25W/kVAr) and housed in cylindrical aluminum casings.
The EQUALIZER’s controller is available with The MKP-type capacitor is a metallized polypropylene film capacitor
a choice of data gathering levels, from featuring self-healing properties and an overpressure tear-off fuse.
essential power parameter measurements To reduce the effects of electrical and thermal overload and extend
only (V, I, f, kW, kVA, kVAr) to complete Harmonic Bar Display Text Display
operating life expectancy, the capacitors are connected during zero-current
power system performance monitoring that crossing and operated in a time-sharing mode (SCAN).
takes advantage of the comprehensive The Equalizer controller is available with several configuration options (see
measurement system (over 2,000 electrical ordering information on back page of catalog): Specifications Ambient Temperature Limits:
parameters, including min/max levels and U - Unbalanced system for three-phase networks with single-phase capacitors Rated Voltage: + 400C: max (< 8 hours)
four-quadrant measurement of power and S - Single phase system for single-phase networks with single-phase capacitors Low voltage systems: + 350C: max 24 hr average
power factor). W - Wind Energy, a version specifically designed for wind turbine generator 220 V - 690 V + 200C: yearly average
applications 50 or 60 Hz - 100C: minimum
The large LCD display is full-graphic, 160x128 V - Voltage Control, where the controller connects or disconnects steps Single phase or three-phase
pixels, and has long-lasting LED backlighting according to user-defined voltage limits (6-level) Capacitors:
with FSTN technology. Characters are T - Medium Voltage compensation, using LV capacitors and step-down 1 Group Switching Module System Structure Medium voltage systems: Low loss, self healing, IEC 831-1/2
displayed in varying sizes and methods to transformer up to 69 kV
enhance visibility. These include a Large M - Medium Voltage compensation, using MV capacitors (see Type T) Cabinet Design 50 or 60Hz Protection class:
Digits display, Harmonic spectrums, real-time G - Generator applications, allows two power factor targets dependent on Each EQUALIZER system IP20/NEMA1 IP 20 / NEMA 1 (Other on request)
Waveform plots and simple Text screens that generator mode of operation cabinet is made of steel sheet, which is
include menus, easy-to-use setup programs P - External trigger signal for synchronized compensation, allowing instantaneous epoxy powder coated gray (RAL 7032). Controller Display:
and various measurements. compensation (0ms) 5” Graphic LCD

S o l u t i o n s
Cabinet Options 160*128 pixels
•Protection class upgrades (IP/NEMA) High visibility (FSTN)
•Top-mounted fan unit and filters Durable LED Backlight
PowerIQ - Measurement & Analysis Software •Lockable controller panel
This optional proprietary software works in parallel with the on-board controller, displaying system status and measurement results •Blown fuse indication Design:
in a Windows operating environment, and allows the user remote-access to control various parameters of EQUALIZER system. •Magnetic door lock Steel sheet cabinet
All network parameters, including harmonics, can be recorded continually or for pre-selected intervals. Recording time is limited •Top cable supports
only by the size of the computer's hard disk or other storage device (server, memory card, etc). Electrical events can be captured •Lifting eye bolts Enclosure Finish:
by associating trigger values to various network power parameters, such as low voltage or high current. The event recording will •Pad-lock entry Switching Module Epoxy powder coated
capture a user-selected before and after window of time. PowerIQ has intranet and internet support capabilities. Gray (RAL 7032)

Controller Internal parts:


Rust-proof alu-zinc

EMC Standards:
Capacitor/Reactor EN 50081-2
Module EN 50082-2
EN 55011,
EN 61000-4-2/3/4/5
ENV 50204
ENV 50141
Reactor
Safety Standards:
EN 61010-1
EN 60439-1
Capacitors UL 508 (on request)

3 Group Switching
PowerIQ Windows Examples Module System Structure
P o w e r
The Controller System Structure
A digital signal processor (DSP) and a VLSI Switching Module Capacitor/Reactor Modules
component form the basis of the controller’s The switching module is comprised of Iron Core Reactors
technology. It features an LCD display, analog solid-state switching elements that Each Elspec EQUALIZER includes specially designed, iron core reactors
and digital circuitry, precise firing algorithms provide reliable, high-speed, transient- used in series with the capacitors. Each reactor is manufactured under
and optional communication capabilities. free operation. Single, double or three- tight control tolerances to ensure quality, constructed with a laminated,
The controller has 9 input channels: 4 voltages phase electronic switches, SCR/SCR or low-hysterisis loss iron core, copper windings, precision-controlled air
(for Wye networks), 3 main currents and 2 SCR/diode, are used for each capacitor gaps and Class H insulation (1800C).
internal system currents. The information group. Switching modules are
obtained from these measurements is used specifically selected for each EQUALIZER Available reactor types:
for Fast Fourier Transform (FFT) analysis, system based on the number of overall Inrush-only: Reactors designed to limit the inrush current which may
performed each network cycle on all Digits Display Waveform Display capacitor groups, current requirements develop in the capacitors during power up, avoiding damage to switching
channels. The advanced control algorithm, and voltage ratings. elements, fuses and capacitors
which includes unique patent-pending De-tuned: Prevent resonance condition by shifting the capacitor/network
technology for fast compensation, calculates resonant frequency to below the first dominant harmonic (usually the 5th)
the required compensation in 1ms. Further, Tuned: Designed to absorb a majority of the dominant harmonic(s), usually
harmonics are calculated on all phases, the 5th and/or 7th.
allowing the EQUALIZER to achieve ideal

Q u a l i t y
compensation even in the presence of Capacitors
harmonics. Elspec EQUALIZER features MKP-type capacitors that are low-loss
(0.25W/kVAr) and housed in cylindrical aluminum casings.
The EQUALIZER’s controller is available with The MKP-type capacitor is a metallized polypropylene film capacitor
a choice of data gathering levels, from featuring self-healing properties and an overpressure tear-off fuse.
essential power parameter measurements To reduce the effects of electrical and thermal overload and extend
only (V, I, f, kW, kVA, kVAr) to complete Harmonic Bar Display Text Display
operating life expectancy, the capacitors are connected during zero-current
power system performance monitoring that crossing and operated in a time-sharing mode (SCAN).
takes advantage of the comprehensive The Equalizer controller is available with several configuration options (see
measurement system (over 2,000 electrical ordering information on back page of catalog): Specifications Ambient Temperature Limits:
parameters, including min/max levels and U - Unbalanced system for three-phase networks with single-phase capacitors Rated Voltage: + 400C: max (< 8 hours)
four-quadrant measurement of power and S - Single phase system for single-phase networks with single-phase capacitors Low voltage systems: + 350C: max 24 hr average
power factor). W - Wind Energy, a version specifically designed for wind turbine generator 220 V - 690 V + 200C: yearly average
applications 50 or 60 Hz - 100C: minimum
The large LCD display is full-graphic, 160x128 V - Voltage Control, where the controller connects or disconnects steps Single phase or three-phase
pixels, and has long-lasting LED backlighting according to user-defined voltage limits (6-level) Capacitors:
with FSTN technology. Characters are T - Medium Voltage compensation, using LV capacitors and step-down 1 Group Switching Module System Structure Medium voltage systems: Low loss, self healing, IEC 831-1/2
displayed in varying sizes and methods to transformer up to 69 kV
enhance visibility. These include a Large M - Medium Voltage compensation, using MV capacitors (see Type T) Cabinet Design 50 or 60Hz Protection class:
Digits display, Harmonic spectrums, real-time G - Generator applications, allows two power factor targets dependent on Each EQUALIZER system IP20/NEMA1 IP 20 / NEMA 1 (Other on request)
Waveform plots and simple Text screens that generator mode of operation cabinet is made of steel sheet, which is
include menus, easy-to-use setup programs P - External trigger signal for synchronized compensation, allowing instantaneous epoxy powder coated gray (RAL 7032). Controller Display:
and various measurements. compensation (0ms) 5” Graphic LCD

S o l u t i o n s
Cabinet Options 160*128 pixels
•Protection class upgrades (IP/NEMA) High visibility (FSTN)
•Top-mounted fan unit and filters Durable LED Backlight
PowerIQ - Measurement & Analysis Software •Lockable controller panel
This optional proprietary software works in parallel with the on-board controller, displaying system status and measurement results •Blown fuse indication Design:
in a Windows operating environment, and allows the user remote-access to control various parameters of EQUALIZER system. •Magnetic door lock Steel sheet cabinet
All network parameters, including harmonics, can be recorded continually or for pre-selected intervals. Recording time is limited •Top cable supports
only by the size of the computer's hard disk or other storage device (server, memory card, etc). Electrical events can be captured •Lifting eye bolts Enclosure Finish:
by associating trigger values to various network power parameters, such as low voltage or high current. The event recording will •Pad-lock entry Switching Module Epoxy powder coated
capture a user-selected before and after window of time. PowerIQ has intranet and internet support capabilities. Gray (RAL 7032)

Controller Internal parts:


Rust-proof alu-zinc

EMC Standards:
Capacitor/Reactor EN 50081-2
Module EN 50082-2
EN 55011,
EN 61000-4-2/3/4/5
ENV 50204
ENV 50141
Reactor
Safety Standards:
EN 61010-1
EN 60439-1
Capacitors UL 508 (on request)

3 Group Switching
PowerIQ Windows Examples Module System Structure
Complete System Ordering Information
System Total Step No. of Nominal Nominal Reactors Network Group Cable Cable
Type Power Size Groups Voltage Frequency Percentage Typology Protection Connection Entry
EQ 1440 : 120 : 12 - 400 . 50 - P7 - W F C A

System Type
Total Power
EQ Equalizer Complete System
Total power in kVAr
Real-time power quality enhancement system:
Step Size
No. of Groups
Step size in kVAr (Switching Resolution)
Number of Groups (Physical, max. 12)
Power factor correction, energy savings,
Nominal Voltage
Nominal Frequency
Nominal Phase-to-Phase Voltage in Volts
Nominal Frequency in Hz (50 or 60 Hz)
voltage support, flicker reduction, current spike
Reactors Percentage
P0
P#
Inrush Limiting Reactors Only
Percents of Capacity. Example: P7 = 7%.
reduction, harmonic filtration and many other
D
W
Delta 3 wires
Wye 4 wires
applications for a variety of dynamic loads.
Network Typology
V Wye 3 wires
S Single phase
F Groups protected by Fuses
Group Protection
M Groups protected by MCCBs
C Single Point with Integral Circuit Breaker
Cable Connection S Single Connection Point
M Multiple Connection Points
T Top Cable Entry
B Bottom Cable Entry
Cable Entry A Top and Bottom Cable Entry
L Left-side Cable Entry
R Right-side Cable Entry

Example:
EQ 300:60:3-400.50-P7-WFSA
300kVAr real-time complete Equalizer system with 5 steps of 60 kVAr with 7%
inductors, for 400V/50Hz 4-wires Wye network.
Dimensions (W*D*H): 800*600*2100, Short Circuit 35kA, IP 20

Controller Ordering Information


Controller Type Measurement Level No. of Groups Comm. Card Power Supply Special Type
EQC 3 12 2 - 2 WT

Controller Type EQC Equalizer Controller


2
Measurement Level
3
No. of Groups Number of Groups (Physical, two digits, max. 12)
0 No Communication
Communication Card 1 RS 485 ELCOM Protocol
2 RS 485 ELCOM and MODBUS/RTU Protocols
1 115V
Power Supply
2 230V
See Controller section on previous pages
Special Type
Up to two types can be combined

Measured Parameters
Measurement Level
Parameter Phases Loads
2 3
Frequency Common Mains £ £
Phase Current L1, L2, L3 Mains,Load,Cap. £ £
Neutral Current Neutral Mains £ £
Phase to Phase Current* L1-2, L2-3, L3-1 Mains , Load £ £
Phase Voltage L1, L2, L3 Mains £ £
Neutral Voltage Neutral Mains £ £
Phase to Phase Voltage L1-2, L2-3, L3-1 Mains
ELSPEC Ltd. Active Power (kW) L1, L2, L3, Total Mains
£

£
£

£
Reactive Power (kVAr) L1, L2, L3, Total Mains,Load,Cap.
P. O. Box 3019, Apparent Power (kVA) L1, L2, L3, Total Mains,Load,Cap.
£
£
£
£

4 HaShoham St., Zone 23 Power Factor L1, L2, L3, Total Mains,Load,Cap. £ £

Time of use (TOU) - in, out, net, total:


C a e s a r e a I n d u s t r i a l Pa r k , Active Energy (kWh) Total Mains £ £
38900, ISRAEL Reactive Energy (kVARh) Total Mains £ £

THD at Phase Current L1, L2, L3 Mains,Load,Cap.


Tel: +972-4-6272-470 THD at Neutral Current Neutral Mains
£
£
£
£

Fax: +972-4-6272-465 THD at Phase to Phase Current L1-2, L2-3, L3-1 Mains , Load £ £
THD at Phase Voltage L1, L2, L3 Mains £ £
E-Mail: info@elspec-ltd.com THD at Neutral Voltage Neutral Mains £ £
THD at Phase to Phase Voltage L1-2, L2-3, L3-1 Mains £ £

Harmonics of Phase Current L1, L2, L3 Mains,Load,Cap.


Specifications are subject to Harmonics of Neutral Current Neutral Mains
£
£
Harmonics of Phase to Phase Current L1-2, L2-3, L3-1 Mains , Load
change without notification. Harmonics of Phase Voltage L1, L2, L3 Mains
£
£

All trademarks are the Harmonics of Neutral Voltage


Harmonics of Phase to Phase Voltage
Neutral
L1-2, L2-3, L3-1
Mains
Mains
£
£

property of their respective Waveforms of Phase Current L1, L2, L3 Mains,Load,Cap. £


Waveforms of Neutral Current Neutral Mains £
owners. Waveforms of Phase to Phase Current L1-2, L2-3, L3-1 Mains £
Waveforms of Phase Voltage L1, L2, L3 Mains
Copyright ELSPEC Waveforms of Neutral Voltage Neutral Mains
£
£
Waveforms of Phase to Phase Voltage L1-2, L2-3, L3-1 Mains
Engineering Ltd. 2004 System Log £
£

£
Event Log £ £

w w w. e l s p e c - l t d . c o m * Unique feature: metering internal current of feeder transformer (delta secondary)