Lake Charles Clean Energy, LLC

Lake Charles Clean Energy Project


Document ID
4200 STPD MeOH Unit S-03848 P58001-T 0
Job No. Doc. No Rev.
Page Item No.
Vent wash column
1 of 4
09-T-0001

Process Specification
for
09-T-0001
Vent wash column

Revision Description Date Made By Chd. By Appd. By


0 First Issue 26-Aug-2013 RKUM JASW JYH
Information contained herein is confidential; it may not be used for any purpose other than for which it has been
issued, and may not be used by or disclosed to third parties without written approval of Haldor Topse A/S.
RESEARCH | TECHNOLOGY | CATALYSTS
Lake Charles Clean Energy, LLC
Lake Charles Clean Energy Project
Document ID
4200 STPD MeOH Unit S-03848 P58001-T 0
Job No. Doc. No Rev.
Page Item No.
Vent wash column
2 of 4
09-T-0001

Datasheet for Packed Column


General Equipment Information
Design case 1) Special
Location Outdoor

Inlet Streams
Wash water inlet
Performance point Normal
Temperature 109 F
Pressure psig
Liquid flow 8927 lb/h
Liquid density 61.89 lb/ft
Liquid viscosity 0.623 cP
Liquid surface tension 69 dyn/cm
Vent gas inlet
Performance point Normal
Temperature 107 F
Pressure psig
Gas flow 2) 11953 lb/h
Gas density 0.07 lb/ft
Gas viscosity 0.017 cP
Gas molecular weight 30.34 lb/lbmol

Outlet Streams
Wash water outlet
Performance point Normal
Temperature 97 F
Liquid flow 9385 lb/h
Liquid density 60.17 lb/ft
Liquid viscosity 0.691 cP
Liquid surface tension 61 dyn/cm
Washed vent gas outlet
Performance point Normal
Temperature 110 F
Gas flow 11495 lb/h
Gas density 0.07 lb/ft
Gas viscosity 0.017 cP
Gas molecular weight 29.17 lb/lbmol

Column
Mechanical Design Conditions
Fluid description Water / vent gas
Design temperature (min.) 14 F Design pressure (min.) psig
Design temperature (max.) 220 F Design pressure (max.) 50 psig
Geometrical and Mechanical Data
Inner diameter 3) 42 38 in Tangent to tangent distance 3) 279 in
Mounting Elevation 6) in
Construction code ASME Sec. VIII Stress relieving According to code
Construction material SS304 Corrosion allowance 0 in
Insulation purpose None Insulation thickness in
Top head type Ellipsoidal Bottom head type Ellipsoidal

Information contained herein is confidential; it may not be used for any purpose other than for which it has been
issued, and may not be used by or disclosed to third parties without written approval of Haldor Topse A/S.
RESEARCH | TECHNOLOGY | CATALYSTS
Lake Charles Clean Energy, LLC
Lake Charles Clean Energy Project
Document ID
4200 STPD MeOH Unit S-03848 P58001-T 0
Job No. Doc. No Rev.
Page Item No.
Vent wash column
3 of 4
09-T-0001

Packed Bed
Approach to flooding (design) 4) 48 % Location (from lower TL) 40 in
Turndown ratio (design) % Packed bed diameter 3) 38 in
Foaming tendency Negligible
Inlet Distributor
Distributor type Koch-Glitsch model 906 or equivalent
Distributor thickness in Distributor material SS
Location from feed nozzle in Wall wiper required No
Packed Layers (from Top)
Description Size Volume Unit Height Unit Rem.
SS 304 IMTP or equivalent IMTP 2'' 129 ft 197 in
Support Grid
Support grid type Koch-Glitsch model 814 or equivalent
Support grid material SS
Packing weight lb Liquid holdup design weight lb
Total design weight lb Total design load 5) 1.2 psi

Nozzles and Connections


Ref. No. Size Description Nozzle Device
A1 1 2" Wash water inlet Liquid feed pipe
A2 1 12" 14" Vent gas inlet
B1 1 2" Wash water outlet Vortex breaker
B2 1 12" 14" Washed vent gas outlet
H 1 8" Handhole
M 1 20" Manhole
Liquid feed pipe details (nozzle A1)
Koch-Glitsch type 719 or equivalent.

Remarks
1 Max. venting from tanks TK-0001,TK-0002 A/B and TK-0003
2 Maximum flow calculated includes vent gas from raw methanol buffer tank (TK-0001), methanol product buffer tanks (TK-
0002 A/B) and liquid off stream tank (TK-0003). Figure represents steady state flow. Actual flow may vary due to thermal
breathing and product movement.
3 To be confirmed during detailed design.
4 Pressure drop for whole system including gas venting piping shall be below 10 mbar.
5 To be confirmed by packing vendor.
6 Column to be located at an elevation that allows gravity flow of liquid back to the raw methanol buffer tank, TK-0001.

L2 DC1 C1 rkum 1618779


Information contained herein is confidential; it may not be used for any purpose other than for which it has been
issued, and may not be used by or disclosed to third parties without written approval of Haldor Topse A/S.
RESEARCH | TECHNOLOGY | CATALYSTS
Lake Charles Clean Energy, LLC
Lake Charles Clean Energy Project
Document ID
4200 STPD MeOH Unit S-03848 P58001-T 0
Job No. Doc. No Rev.
Page Item No.
Vent wash column
4 of 4
09-T-0001

42
38
B2

T.L.

M
42

A1
197

279

A2
40

T.L.

B1

All sketch measurements are indicated in inches.


Information contained herein is confidential; it may not be used for any purpose other than for which it has been
issued, and may not be used by or disclosed to third parties without written approval of Haldor Topse A/S.
RESEARCH | TECHNOLOGY | CATALYSTS