Cat Electronic Technician 2017A v1.

0
Product Status Report

30/07/2017 11:36

Product Status Report


Parameter Value
Product ID M4T01049
Equipment ID M4T01049
Comments

C9 330D (THX31187)
Parameter Value
Equipment ID M4T01049
Engine Serial Number THX31187
ECM Part Number 3722906-00
ECM Serial Number 31416054JM
Personality Module Part Number 3770005-00
Personality Module Release Date JUN11
Personality Module Description 330D-HEX-C9-HI_LRC
Active Event Codes Present Unavailable

Logged Diagnostic Codes [Diagnostic Clock = 6586.8989 hours] - C9 330D (THX31187)


Code Description Occ. First Last
No Logged
Diagnostic
Codes

Logged Event Codes [Diagnostic Clock = 6586.8989 hours] - C9 330D (THX31187)


Code Description Occ. First Last
No Logged
Event Codes

Active Diagnostic Codes - C9 330D (THX31187)


Code Description
No Active
Diagnostic
Codes

Active Event Codes - C9 330D (THX31187)


Code Description
No Active
Event Codes

Current Totals - C9 330D (THX31187)


Description Value Unit
Engine Lifetime Hours Unavailable hours
Total Operating Hours 6587 hours
Total Fuel 157510 L
Engine Starts 3713
Lifetime Total Engine 612733656 rev
Revolutions
Total Idle Time 1669:27 hours
Total Idle Fuel 6489 L
Total Max Fuel 334997 L
Average Load Factor 45 %
Overall Load Factor 47 %

Configuration - C9 330D (THX31187)


Description Value Unit
Equipment ID M4T01049
Engine Serial Number THX31187
ECM Part Number 3722906-00
ECM Serial Number 31416054JM
Personality Module Part Number 3770005-00
Personality Module Release Date JUN11
Personality Module Description 330D-HEX-C9-HI_LRC
Rated Power 213 kW at 1800 rpm
Rated Peak Torque 1356 N-m at 1400 rpm
Test Spec 0K6787 0K6788
Top Engine Speed Range 1980 - 1980 rpm
Ether Solenoid Configuration Continuous Flow Solenoid
FLS -37
FTS 41
Security System Immobilizer Installation Disabled or Not Installed
Status
Total Tattletale 8

Lifetime: Time vs Engine Coolant Temperature - C9 330D (THX31187)


Engine Coolant Temperature( hours %
Deg C )
<50 191.55 2.92
50-54 48.35 0.74
55-59 48.00 0.73
60-64 51.95 0.79
65-69 155.45 2.37
70-74 627.60 9.57
75-79 659.55 10.06
80-84 2402.30 36.65
85-89 1734.20 26.46
90-94 635.00 9.69
95-99 0.80 0.01
100-104 0.00 0.00
105-109 0.00 0.00
110-114 0.00 0.00
115-119 0.00 0.00
>120 0.00 0.00

Lifetime: Time vs Inlet Air Temperature - C9 330D (THX31187)


Inlet Air Temperature( Deg C ) hours %
<40 1099.65 39.30
40-44 682.15 24.38
45-49 633.50 22.64
50-54 325.25 11.62
55-59 56.70 2.03
60-64 0.95 0.03
65-69 0.00 0.00
70-74 0.00 0.00
75-79 0.00 0.00
80-84 0.00 0.00
85-89 0.00 0.00
90-94 0.00 0.00
95-99 0.00 0.00
>100 0.00 0.00

Lifetime: Time vs Boost Pressure - C9 330D (THX31187)


Boost Pressure( kPa ) hours %
<80 357.65 12.78
80-89 364.50 13.03
90-99 558.05 19.94
100-109 626.15 22.38
110-119 564.90 20.19
120-129 276.05 9.87
130-139 50.60 1.81
140-149 0.30 0.01
150-159 0.00 0.00
160-169 0.00 0.00
170-179 0.00 0.00
180-189 0.00 0.00
190-199 0.00 0.00
>200 0.00 0.00

Lifetime: Time vs Engine Speed And Engine Load Factor - C9 330D (THX31187)
rpm <1100 1100- 1300- 1500- 1700- 1900- 2100- >2300 Total
1299 1499 1699 1899 2099 2299
%
<50 912.30 52.25 638.30 18.45 136.10 375.80 0.00 0.00 2133.20
50-60 0.00 0.15 0.90 2.55 42.30 43.70 0.00 0.00 89.60
60-70 0.00 0.00 0.35 2.65 46.40 41.40 0.00 0.00 90.80
70-80 0.00 0.00 0.10 2.65 53.45 43.20 0.00 0.00 99.40
80-90 0.00 0.00 0.00 1.50 106.65 79.35 0.00 0.00 187.50
>90 0.10 0.00 0.10 10.90 1860.65 965.70 0.00 0.00 2837.45
Total 912.40 52.40 639.75 38.70 2245.55 1549.15 0.00 0.00 5437.95
Lifetime: Total Occurrences vs Engine Speed - C9 330D (THX31187)
Engine Speed( rpm ) %
<2500 0.00 0.00
2500-2599 0.00 0.00
2600-2699 0.00 0.00
2700-2799 0.00 0.00
2800-2899 0.00 0.00
2900-2999 0.00 0.00
3000-3099 0.00 0.00
3100-3199 0.00 0.00
3200-3299 0.00 0.00
>3300 1.00 100.00

Injector Trim Calibration - C9 330D (THX31187)


Injector Serial Number File Version Tattletale
Injector1 000000003B12756147 0 0
DE
Injector2 000000003B12778464 0 1
3D
Injector3 000000003B12756046 0 0
B2
Injector4 000000003B12756039 0 0
F4
Injector5 000000003B12756121 0 0
B2
Injector6 000000003B12756038 0 0
F3

Machine Control 330D/336D (M4T01049)


Parameter Value
Product ID M4T01049
ECM Part Number 2218874-07
ECM Serial Number 01435752EM
Software Group Part Number 3495467-00
Software Group Release Date SEP2009
Software Group Description 330D/336D HEX CONTROL
Active Diagnostic Codes Present No

Logged Diagnostic Codes [Diagnostic Clock = 8392 hours] - Machine Control 330D/336D
(M4T01049)
Code Description Occ. First Last
No Logged
Diagnostic
Codes

Logged Event Codes [Diagnostic Clock = 8392 hours] - Machine Control 330D/336D (M4T01049)
Code Description Occ. First Last
No Logged
Event Codes
Active Diagnostic Codes - Machine Control 330D/336D (M4T01049)
Code Description
No Active
Diagnostic
Codes

Current Totals - Machine Control 330D/336D (M4T01049)


Description Value Unit
Total Operating Hours 8393 hours
Engine Maintenance Hours 8391 hours
Engine Oil Hours 5476 hours
Engine Oil Filter Hours 5476 hours
Engine Coolant Hours 4872 hours
Fuel/ Water Separator Hours 0 hours
Fuel Filter Hours 5476 hours
Hydraulic Pump Hours 8391 hours
Hydraulic Pilot Oil Filter Hours 5476 hours
Hydraulic Case Drain Oil Filter 5476 hours
Hours
Return Hydraulic Oil Filter 5476 hours
Hours
Attachment Hydraulic Oil Filter 0 hours
Hours
Hydraulic Oil Hours 5476 hours
Final Drive Oil Hours 5476 hours
Swing Drive Oil Hours 5476 hours
Travel Motor Hours 1101 hours
Tool #1 Hours 0 hours
Tool #2 Hours 0 hours
Tool #3 Hours 0 hours
Tool #4 Hours 0 hours
Tool #5 Hours 0 hours
Tool #6 Hours 0 hours
Tool #7 Hours 0 hours
Tool #8 Hours 0 hours
Tool #9 Hours 0 hours
Tool #10 Hours 0 hours
Return Hydraulic Oil Filter 338.6 hours
Bypass Hours
Return Hydraulic Oil Filter 22.6 hours
Bypass at Cold Temperature
Hours
Hours of Operation at High 361.3 hours
Hydraulic Pressure
Hours of Operation at Relief 99.2 hours
Hydraulic Pressure

Configuration - Machine Control 330D/336D (M4T01049)


Description Value Unit
Product ID M4T01049
Hydraulic Power Mode High
Fuel Economy Mode Enable Status Enabled
Economy Mode Off
Travel Alarm Installation Status Installed
Water Separator Level Switch Normally Closed (to Ground)
Configuration
Fuel Filter Differential Pressure Switch Not Installed
Config
Secondary Fuel Filter Differential Pressure Not Installed
Switch Config
Attachment Hydraulic Oil Filter Switch Not Installed
Configuration
Auto Lube Warning Indicator Enable Switch Not Installed
Configuration
Machine Overload Pressure Sensor Not Installed
Installation
Machine Overload Pressure Threshold Disabled or Not Installed kPa
Heavy Lift System Installation Status Installed
Engine Cooling Fan Map High Ambient
Engine Fan Reversing Feature Installation Not Installed
Status
Engine Fan Reverse Operation Time Disabled or Not Installed sec
Machine Application Configuration EAME Hammer
Main Pump Flow Limitation Pressure Installed
Solenoid Installation Status
Attachment Valve #1 Configuration F2 - One Way
Attachment Valve #2 Configuration F2 - One Way
Attachment Valve #3 Configuration Not Installed
Attachment Valve #4 Configuration Not Installed
Attachment Valve #1 Control Type Electrical
Configuration
Attachment Valve #2 Control Type Electrical
Configuration
Attachment Valve #3 Control Type Disabled or Not Installed
Configuration
Attachment Valve #4 Control Type Disabled or Not Installed
Configuration
Attachment Valve #1 Combiner Valve #2 Combined with Valve #1
Configuration
Auxiliary Circuit Flow Combining Solenoid Disabled or Not Installed
Installation Status
Hammer Return to Tank Solenoid Disabled or Not Installed
Installation Status
Variable Relief Valve Type Configuration Disabled or Not Installed
Variable Relief Valve #1 Configuration Not Installed
Variable Relief Valve #2 Configuration Not Installed
F2 Type Valve Load Sense Pres Sensor Not Installed
Installation
Joystick Handle Configuration Joystick Switch
Foot Switch Installation Status Not Installed
Left Attachment Pedal Installation Status Not Installed
Right Attachment Pedal Installation Status Not Installed
Left Joystick Switch #1 Control Mode No valve controlled
Left Joystick Switch #2 Control Mode No valve controlled
Left Joystick Switch #4 Control Mode No valve controlled
Right Joystick Switch #1 Control Mode No valve controlled
Right Joystick Switch #2 Control Mode No valve controlled
Right Joystick Switch #4 Control Mode Momentary - Valve #1 Extend
Foot Switch Control Mode Disabled or Not Installed
Left Joystick Thumbwheel Control Mode Disabled or Not Installed
Right Joystick Thumbwheel Control Mode Disabled or Not Installed
Left Attachment Pedal Control Mode Disabled or Not Installed
Right Attachment Pedal Control Mode Disabled or Not Installed
Travel Speed Shift Low Delay 0.4 sec
Travel Speed Shift High Delay 0.4 sec
Travel Speed Shift Low Pres 18000 kPa
Travel Speed Shift High Pressure 32000 kPa
One Touch Engine Speed Setting 1020 rpm
AESC Setting 1300 rpm
AESC Delay Time 5.0 sec
Throttle Dial Position 1 Engine Speed 800 rpm
Throttle Dial Position 2 Engine Speed 1020 rpm
Throttle Dial Position 3 Engine Speed 1160 rpm
Throttle Dial Position 4 Engine Speed 1300 rpm
Throttle Dial Position 5 Engine Speed 1470 rpm
Throttle Dial Position 6 Engine Speed 1590 rpm
Throttle Dial Position 7 Engine Speed 1700 rpm
Throttle Dial Position 8 Engine Speed 1800 rpm
Throttle Dial Position 9 Engine Speed 1900 rpm
Throttle Dial Position 10 Engine Speed 1980 rpm
Throttle Dial Position 1 Hydraulic System 20.0 %
Torque Percentage
Throttle Dial Position 2 Hydraulic System 35.0 %
Torque Percentage
Throttle Dial Position 3 Hydraulic System 45.0 %
Torque Percentage
Throttle Dial Position 4 Hydraulic System 69.0 %
Torque Percentage
Throttle Dial Position 5 Hydraulic System 78.0 %
Torque Percentage
Throttle Dial Position 6 Hydraulic System 84.0 %
Torque Percentage
Throttle Dial Position 7 Hydraulic System 84.0 %
Torque Percentage
Throttle Dial Position 8 Hydraulic System 84.0 %
Torque Percentage
Throttle Dial Position 9 Hydraulic System 92.0 %
Torque Percentage
Throttle Dial Position 10 Hydraulic System 100.0 %
Torque Percentage
Engine Oil Recommended Maintenance 500 hours
Interval
Engine Oil Filter Recommended 500 hours
Maintenance Interval
Engine Coolant Recommended 3000 hours
Maintenance Interval
Fuel/ Water Separator Recommended 0 hours
Maint Interval
Fuel Filter Recommended Maintenance 500 hours
Interval
Hydraulic Pilot Oil Filter Recommended 1000 hours
Maintenance Interval
Hydraulic Case Drain Oil Filter 1000 hours
Recommended MI
Return Hyd Oil Filter Recommended Maint 2000 hours
Interval
Attachment Hydraulic Oil Filter 0 hours
Recommended Maintenance Interval
Final Drive Oil Recommended 2000 hours
Maintenance Interval
Hydraulic Oil Recommended Maintenance 2000 hours
Interval
Swing Drive Oil Recommended 1000 hours
Maintenance Interval
Advanced Machine Security System Not Installed
Installation Status
Sunday Security System Bypass Start Disabled or Not Installed
Time
Sunday Security System Bypass Stop Time Disabled or Not Installed
Monday Security System Bypass Start Disabled or Not Installed
Time
Monday Security System Bypass Stop Disabled or Not Installed
Time
Tuesday Security System Bypass Start Disabled or Not Installed
Time
Tuesday Security System Bypass Stop Disabled or Not Installed
Time
Wednesday Security System Bypass Start Disabled or Not Installed
Time
Wednesday Security System Bypass Stop Disabled or Not Installed
Time
Thursday Security System Bypass Start Disabled or Not Installed
Time
Thursday Security System Bypass Stop Disabled or Not Installed
Time
Friday Security System Bypass Start Time Disabled or Not Installed
Friday Security System Bypass Stop Time Disabled or Not Installed
Saturday Security System Bypass Start Disabled or Not Installed
Time
Saturday Security System Bypass Stop Disabled or Not Installed
Time
Crane System Installation Status Disabled or Not Installed
Undercarriage Length Configuration Disabled or Not Installed
Boom Angle Adjustment Unavailable Deg
Crane Actual Load Adjustment Unavailable kg
Crane Swing Speed Adjustment Unavailable %
AccuGrade System Installation Status Disabled or Not Installed
Hydraulic Cab Riser Installation Status Disabled or Not Installed
Hydraulic Cab Riser Raise Snubbing Angle Disabled or Not Installed
Gain
Hydraulic Cab Riser Raise Snubbing Rate Disabled or Not Installed
Gain
Hydraulic Cab Riser Lower Snubbing Angle Disabled or Not Installed
Gain
Hydraulic Cab Riser Lower Snubbing Rate Disabled or Not Installed
Gain

Calibration Status - Machine Control 330D/336D (M4T01049)


Calibration Status Last Successful Completion
Attachment Valve #1 Extend Not Calibrated Never Successfully Calibrated
Attachment Valve #1 Retract Not Calibrated Never Successfully Calibrated
Attachment Valve #2 Extend Not Calibrated Never Successfully Calibrated
Attachment Valve #2 Retract Not Calibrated Never Successfully Calibrated
Attachment Valve #3 Extend Not Calibrated Never Successfully Calibrated
Attachment Valve #3 Retract Not Calibrated Never Successfully Calibrated
Attachment Valve #4 Extend Not Calibrated Never Successfully Calibrated
Attachment Valve #4 Retract Not Calibrated Never Successfully Calibrated
Engine Cooling Fan Calibration Success 0.7 hours
Engine Speed Calibration Success 0.1 hours
Left Joystick Thumbwheel Not Calibrated Never Successfully Calibrated
Calibration
Right Joystick Thumbwheel Not Calibrated Never Successfully Calibrated
Calibration
Left Attachment Pedal Not Calibrated Never Successfully Calibrated
Calibration
Right Attachment Pedal Not Calibrated Never Successfully Calibrated
Calibration
PRV - Pressure Gauge Not Calibrated Never Successfully Calibrated
PRV - Flow Meter for Two Not Calibrated Never Successfully Calibrated
Pump Flow Combined
PRV - Attachment Valve #1 Not Calibrated Never Successfully Calibrated
Flow Limit
PRV - Combined Attachment Not Calibrated Never Successfully Calibrated
Valve Flow Limit
PRV - Power Shift Pressure Success 0.2 hours
Calibration
Boom Cylinder Extend Pilot Not Calibrated Never Successfully Calibrated
Pressure Limit Solenoid Cal
Stick Cylinder Retract Pilot Not Calibrated Never Successfully Calibrated
Pressure Limit Solenoid Cal
PRV - Variable Relief Pressure Not Calibrated Never Successfully Calibrated
Calibration Solenoid 1
PRV - Variable Relief Pressure Not Calibrated Never Successfully Calibrated
Calibration Solenoid 2

Lifetime: Time vs Hydraulic Oil Temperature - Machine Control 330D/336D (M4T01049)


Hydraulic Oil Temperature( Deg hours %
C)
<20 436.50 5.20
20-29 674.55 8.04
30-39 838.75 9.99
40-49 1380.95 16.45
50-59 1135.30 13.53
60-69 1845.90 21.99
70-79 1895.70 22.58
80-89 186.00 2.22
90-99 0.00 0.00
100-109 0.00 0.00
110-119 0.00 0.00
>120 0.00 0.00

Lifetime: Time vs Front Hyd Pump Pres - Machine Control 330D/336D (M4T01049)
Front Hyd Pump Pres( kPa ) hours %
<20000 6779.35 80.77
20000-21999 586.75 6.99
22000-23999 442.75 5.27
24000-25999 271.65 3.24
26000-27999 132.80 1.58
28000-29999 62.55 0.75
30000-31999 35.25 0.42
32000-33999 24.05 0.29
34000-35999 43.70 0.52
36000-37999 11.60 0.14
38000-39999 0.55 0.01
>40000 2.45 0.03

Lifetime: Time vs Rear Hyd Pump Pres - Machine Control 330D/336D (M4T01049)
Rear Hyd Pump Pres( kPa ) hours %
<20000 6341.75 75.56
20000-21999 520.60 6.20
22000-23999 392.80 4.68
24000-25999 286.15 3.41
26000-27999 262.30 3.13
28000-29999 283.30 3.38
30000-31999 183.50 2.19
32000-33999 50.70 0.60
34000-35999 43.80 0.52
36000-37999 25.70 0.31
38000-39999 0.45 0.01
>40000 2.45 0.03

Tool Configuration - Machine Control 330D/336D (M4T01049)


Description Value Unit
Tool Program Name H130S
Maximum Throttle Dial 10
Minimum Throttle Dial Position 1
Underspeed Enable Enabled
Two Pump Flow Combine Disabled
Enable
Initial Tool Program Medium Disabled or Not Installed %
Pressure Circuit Main Pump
Torque Reduction
Total Tool Program Medium Disabled or Not Installed %
Pressure Circuit Main Pump
Torque Reduction
One Way/ Two Way Valve Disabled or Not Installed
Mode
Variable Relief Valve #1 Disabled or Not Installed kPa
Pressure
Variable Relief Valve #2 Disabled or Not Installed kPa
Pressure
F2 Type Valve Max Flow Disabled or Not Installed kPa
Derate Pressure
F2 Type Valve Flow Derate Disabled or Not Installed kPa
Start Pressure
F2 Type Valve Flow Derate End Disabled or Not Installed kPa
Pressure
Multiple Operation Maximum 4000 kPa
Extend Pilot Pressure for
Attachment Valve #1
Multiple Operation Maximum Disabled or Not Installed kPa
Retract Pilot Pressure for
Attachment Valve #1
Multiple Operation Maximum 4000 kPa
Extend Pilot Pres for Combined
Attachment Valve
Multiple Operation Maximum Disabled or Not Installed kPa
Retract Pilot Pres for Combined
Attachment Valve
Hydraulic Temperature High 80.0 Deg C
Warning Event Threshold
Attachment Valve #1 Flow 190 L/min
Setting
Attachment Valve #1 Multi- 0 L/min
Operation Additional Flow
Valve #1 Nominal Pressure 16000 kPa
Attachment Valve #1 Maximum 4000 kPa
Extend Pressure
Attachment Valve #1 Maximum Disabled or Not Installed kPa
Retract Pressure
Attachment Valve #1 Open 0.20 sec
Time
Attachment Valve #1 Close 0.20 sec
Time
Attachment Valve #1 Tool Flow Disabled or Not Installed
Direction
Attachment Valve #2 Flow Disabled or Not Installed L/min
Setting
Attachment Valve #2 Multi- Disabled or Not Installed L/min
Operation Additional Flow
Valve #2 Nominal Pressure Disabled or Not Installed kPa
Attachment Valve #2 Maximum 4000 kPa
Extend Pressure
Attachment Valve #2 Maximum Disabled or Not Installed kPa
Retract Pressure
Attachment Valve #2 Open 0.20 sec
Time
Attachment Valve #2 Close 0.20 sec
Time
Attachment Valve #2 Tool Flow Disabled or Not Installed
Direction
Attachment Valve #3 Flow Disabled or Not Installed L/min
Setting
Attachment Valve #3 Multi- Disabled or Not Installed L/min
Operation Additional Flow
Valve #3 Nominal Pressure Disabled or Not Installed kPa
Attachment Valve #3 Maximum Disabled or Not Installed kPa
Extend Pressure
Attachment Valve #3 Maximum Disabled or Not Installed kPa
Retract Pressure
Attachment Valve #3 Open Disabled or Not Installed sec
Time
Attachment Valve #3 Close Disabled or Not Installed sec
Time
Attachment Valve #3 Tool Flow Disabled or Not Installed
Direction
Attachment Valve #4 Flow Disabled or Not Installed L/min
Setting
Attachment Valve #4 Multi- Disabled or Not Installed L/min
Operation Additional Flow
Valve #4 Nominal Pressure Disabled or Not Installed kPa
Attachment Valve #4 Maximum Disabled or Not Installed kPa
Extend Pressure
Attachment Valve #4 Maximum Disabled or Not Installed kPa
Retract Pressure
Attachment Valve #4 Open Disabled or Not Installed sec
Time
Attachment Valve #4 Close Disabled or Not Installed sec
Time
Attachment Valve #4 Tool Flow Disabled or Not Installed
Direction

Tool Configuration - Machine Control 330D/336D (M4T01049)


Description Value Unit
Tool Program Name H140DS
Maximum Throttle Dial 10
Minimum Throttle Dial Position 1
Underspeed Enable Enabled
Two Pump Flow Combine Enabled
Enable
Initial Tool Program Medium Disabled or Not Installed %
Pressure Circuit Main Pump
Torque Reduction
Total Tool Program Medium Disabled or Not Installed %
Pressure Circuit Main Pump
Torque Reduction
One Way/ Two Way Valve Disabled or Not Installed
Mode
Variable Relief Valve #1 Disabled or Not Installed kPa
Pressure
Variable Relief Valve #2 Disabled or Not Installed kPa
Pressure
F2 Type Valve Max Flow Disabled or Not Installed kPa
Derate Pressure
F2 Type Valve Flow Derate Disabled or Not Installed kPa
Start Pressure
F2 Type Valve Flow Derate End Disabled or Not Installed kPa
Pressure
Multiple Operation Maximum 4000 kPa
Extend Pilot Pressure for
Attachment Valve #1
Multiple Operation Maximum Disabled or Not Installed kPa
Retract Pilot Pressure for
Attachment Valve #1
Multiple Operation Maximum 4000 kPa
Extend Pilot Pres for Combined
Attachment Valve
Multiple Operation Maximum Disabled or Not Installed kPa
Retract Pilot Pres for Combined
Attachment Valve
Hydraulic Temperature High 80.0 Deg C
Warning Event Threshold
Attachment Valve #1 Flow 200 L/min
Setting
Attachment Valve #1 Multi- 0 L/min
Operation Additional Flow
Valve #1 Nominal Pressure 16000 kPa
Attachment Valve #1 Maximum 4000 kPa
Extend Pressure
Attachment Valve #1 Maximum Disabled or Not Installed kPa
Retract Pressure
Attachment Valve #1 Open 0.20 sec
Time
Attachment Valve #1 Close 0.20 sec
Time
Attachment Valve #1 Tool Flow Disabled or Not Installed
Direction
Attachment Valve #2 Flow Disabled or Not Installed L/min
Setting
Attachment Valve #2 Multi- Disabled or Not Installed L/min
Operation Additional Flow
Valve #2 Nominal Pressure Disabled or Not Installed kPa
Attachment Valve #2 Maximum 4000 kPa
Extend Pressure
Attachment Valve #2 Maximum Disabled or Not Installed kPa
Retract Pressure
Attachment Valve #2 Open 0.20 sec
Time
Attachment Valve #2 Close 0.20 sec
Time
Attachment Valve #2 Tool Flow Disabled or Not Installed
Direction
Attachment Valve #3 Flow Disabled or Not Installed L/min
Setting
Attachment Valve #3 Multi- Disabled or Not Installed L/min
Operation Additional Flow
Valve #3 Nominal Pressure Disabled or Not Installed kPa
Attachment Valve #3 Maximum Disabled or Not Installed kPa
Extend Pressure
Attachment Valve #3 Maximum Disabled or Not Installed kPa
Retract Pressure
Attachment Valve #3 Open Disabled or Not Installed sec
Time
Attachment Valve #3 Close Disabled or Not Installed sec
Time
Attachment Valve #3 Tool Flow Disabled or Not Installed
Direction
Attachment Valve #4 Flow Disabled or Not Installed L/min
Setting
Attachment Valve #4 Multi- Disabled or Not Installed L/min
Operation Additional Flow
Valve #4 Nominal Pressure Disabled or Not Installed kPa
Attachment Valve #4 Maximum Disabled or Not Installed kPa
Extend Pressure
Attachment Valve #4 Maximum Disabled or Not Installed kPa
Retract Pressure
Attachment Valve #4 Open Disabled or Not Installed sec
Time
Attachment Valve #4 Close Disabled or Not Installed sec
Time
Attachment Valve #4 Tool Flow Disabled or Not Installed
Direction

Tool Configuration - Machine Control 330D/336D (M4T01049)


Description Value Unit
Tool Program Name H160DS
Maximum Throttle Dial 10
Minimum Throttle Dial Position 1
Underspeed Enable Enabled
Two Pump Flow Combine Enabled
Enable
Initial Tool Program Medium Disabled or Not Installed %
Pressure Circuit Main Pump
Torque Reduction
Total Tool Program Medium Disabled or Not Installed %
Pressure Circuit Main Pump
Torque Reduction
One Way/ Two Way Valve Disabled or Not Installed
Mode
Variable Relief Valve #1 Disabled or Not Installed kPa
Pressure
Variable Relief Valve #2 Disabled or Not Installed kPa
Pressure
F2 Type Valve Max Flow Disabled or Not Installed kPa
Derate Pressure
F2 Type Valve Flow Derate Disabled or Not Installed kPa
Start Pressure
F2 Type Valve Flow Derate End Disabled or Not Installed kPa
Pressure
Multiple Operation Maximum 4000 kPa
Extend Pilot Pressure for
Attachment Valve #1
Multiple Operation Maximum Disabled or Not Installed kPa
Retract Pilot Pressure for
Attachment Valve #1
Multiple Operation Maximum 4000 kPa
Extend Pilot Pres for Combined
Attachment Valve
Multiple Operation Maximum Disabled or Not Installed kPa
Retract Pilot Pres for Combined
Attachment Valve
Hydraulic Temperature High 80.0 Deg C
Warning Event Threshold
Attachment Valve #1 Flow 261 L/min
Setting
Attachment Valve #1 Multi- 0 L/min
Operation Additional Flow
Valve #1 Nominal Pressure 16000 kPa
Attachment Valve #1 Maximum 4000 kPa
Extend Pressure
Attachment Valve #1 Maximum Disabled or Not Installed kPa
Retract Pressure
Attachment Valve #1 Open 0.20 sec
Time
Attachment Valve #1 Close 0.20 sec
Time
Attachment Valve #1 Tool Flow Disabled or Not Installed
Direction
Attachment Valve #2 Flow Disabled or Not Installed L/min
Setting
Attachment Valve #2 Multi- Disabled or Not Installed L/min
Operation Additional Flow
Valve #2 Nominal Pressure Disabled or Not Installed kPa
Attachment Valve #2 Maximum 4000 kPa
Extend Pressure
Attachment Valve #2 Maximum Disabled or Not Installed kPa
Retract Pressure
Attachment Valve #2 Open 0.20 sec
Time
Attachment Valve #2 Close 0.20 sec
Time
Attachment Valve #2 Tool Flow Disabled or Not Installed
Direction
Attachment Valve #3 Flow Disabled or Not Installed L/min
Setting
Attachment Valve #3 Multi- Disabled or Not Installed L/min
Operation Additional Flow
Valve #3 Nominal Pressure Disabled or Not Installed kPa
Attachment Valve #3 Maximum Disabled or Not Installed kPa
Extend Pressure
Attachment Valve #3 Maximum Disabled or Not Installed kPa
Retract Pressure
Attachment Valve #3 Open Disabled or Not Installed sec
Time
Attachment Valve #3 Close Disabled or Not Installed sec
Time
Attachment Valve #3 Tool Flow Disabled or Not Installed
Direction
Attachment Valve #4 Flow Disabled or Not Installed L/min
Setting
Attachment Valve #4 Multi- Disabled or Not Installed L/min
Operation Additional Flow
Valve #4 Nominal Pressure Disabled or Not Installed kPa
Attachment Valve #4 Maximum Disabled or Not Installed kPa
Extend Pressure
Attachment Valve #4 Maximum Disabled or Not Installed kPa
Retract Pressure
Attachment Valve #4 Open Disabled or Not Installed sec
Time
Attachment Valve #4 Close Disabled or Not Installed sec
Time
Attachment Valve #4 Tool Flow Disabled or Not Installed
Direction

Tool Configuration - Machine Control 330D/336D (M4T01049)


Description Value Unit
Tool Program Name 0
Maximum Throttle Dial 10
Minimum Throttle Dial Position 1
Underspeed Enable Enabled
Two Pump Flow Combine Disabled
Enable
Initial Tool Program Medium Disabled or Not Installed %
Pressure Circuit Main Pump
Torque Reduction
Total Tool Program Medium Disabled or Not Installed %
Pressure Circuit Main Pump
Torque Reduction
One Way/ Two Way Valve Disabled or Not Installed
Mode
Variable Relief Valve #1 Disabled or Not Installed kPa
Pressure
Variable Relief Valve #2 Disabled or Not Installed kPa
Pressure
F2 Type Valve Max Flow Disabled or Not Installed kPa
Derate Pressure
F2 Type Valve Flow Derate Disabled or Not Installed kPa
Start Pressure
F2 Type Valve Flow Derate End Disabled or Not Installed kPa
Pressure
Multiple Operation Maximum 4000 kPa
Extend Pilot Pressure for
Attachment Valve #1
Multiple Operation Maximum Disabled or Not Installed kPa
Retract Pilot Pressure for
Attachment Valve #1
Multiple Operation Maximum 4000 kPa
Extend Pilot Pres for Combined
Attachment Valve
Multiple Operation Maximum Disabled or Not Installed kPa
Retract Pilot Pres for Combined
Attachment Valve
Hydraulic Temperature High 126.0 Deg C
Warning Event Threshold
Attachment Valve #1 Flow 0 L/min
Setting
Attachment Valve #1 Multi- 0 L/min
Operation Additional Flow
Valve #1 Nominal Pressure 16000 kPa
Attachment Valve #1 Maximum 4000 kPa
Extend Pressure
Attachment Valve #1 Maximum Disabled or Not Installed kPa
Retract Pressure
Attachment Valve #1 Open 0.20 sec
Time
Attachment Valve #1 Close 0.20 sec
Time
Attachment Valve #1 Tool Flow Disabled or Not Installed
Direction
Attachment Valve #2 Flow Disabled or Not Installed L/min
Setting
Attachment Valve #2 Multi- Disabled or Not Installed L/min
Operation Additional Flow
Valve #2 Nominal Pressure Disabled or Not Installed kPa
Attachment Valve #2 Maximum 4000 kPa
Extend Pressure
Attachment Valve #2 Maximum Disabled or Not Installed kPa
Retract Pressure
Attachment Valve #2 Open 0.20 sec
Time
Attachment Valve #2 Close 0.20 sec
Time
Attachment Valve #2 Tool Flow Disabled or Not Installed
Direction
Attachment Valve #3 Flow Disabled or Not Installed L/min
Setting
Attachment Valve #3 Multi- Disabled or Not Installed L/min
Operation Additional Flow
Valve #3 Nominal Pressure Disabled or Not Installed kPa
Attachment Valve #3 Maximum Disabled or Not Installed kPa
Extend Pressure
Attachment Valve #3 Maximum Disabled or Not Installed kPa
Retract Pressure
Attachment Valve #3 Open Disabled or Not Installed sec
Time
Attachment Valve #3 Close Disabled or Not Installed sec
Time
Attachment Valve #3 Tool Flow Disabled or Not Installed
Direction
Attachment Valve #4 Flow Disabled or Not Installed L/min
Setting
Attachment Valve #4 Multi- Disabled or Not Installed L/min
Operation Additional Flow
Valve #4 Nominal Pressure Disabled or Not Installed kPa
Attachment Valve #4 Maximum Disabled or Not Installed kPa
Extend Pressure
Attachment Valve #4 Maximum Disabled or Not Installed kPa
Retract Pressure
Attachment Valve #4 Open Disabled or Not Installed sec
Time
Attachment Valve #4 Close Disabled or Not Installed sec
Time
Attachment Valve #4 Tool Flow Disabled or Not Installed
Direction

Tool Configuration - Machine Control 330D/336D (M4T01049)


Description Value Unit
Tool Program Name 0
Maximum Throttle Dial 10
Minimum Throttle Dial Position 1
Underspeed Enable Enabled
Two Pump Flow Combine Disabled
Enable
Initial Tool Program Medium Disabled or Not Installed %
Pressure Circuit Main Pump
Torque Reduction
Total Tool Program Medium Disabled or Not Installed %
Pressure Circuit Main Pump
Torque Reduction
One Way/ Two Way Valve Disabled or Not Installed
Mode
Variable Relief Valve #1 Disabled or Not Installed kPa
Pressure
Variable Relief Valve #2 Disabled or Not Installed kPa
Pressure
F2 Type Valve Max Flow Disabled or Not Installed kPa
Derate Pressure
F2 Type Valve Flow Derate Disabled or Not Installed kPa
Start Pressure
F2 Type Valve Flow Derate End Disabled or Not Installed kPa
Pressure
Multiple Operation Maximum 4000 kPa
Extend Pilot Pressure for
Attachment Valve #1
Multiple Operation Maximum Disabled or Not Installed kPa
Retract Pilot Pressure for
Attachment Valve #1
Multiple Operation Maximum 4000 kPa
Extend Pilot Pres for Combined
Attachment Valve
Multiple Operation Maximum Disabled or Not Installed kPa
Retract Pilot Pres for Combined
Attachment Valve
Hydraulic Temperature High 126.0 Deg C
Warning Event Threshold
Attachment Valve #1 Flow 0 L/min
Setting
Attachment Valve #1 Multi- 0 L/min
Operation Additional Flow
Valve #1 Nominal Pressure 16000 kPa
Attachment Valve #1 Maximum 4000 kPa
Extend Pressure
Attachment Valve #1 Maximum Disabled or Not Installed kPa
Retract Pressure
Attachment Valve #1 Open 0.20 sec
Time
Attachment Valve #1 Close 0.20 sec
Time
Attachment Valve #1 Tool Flow Disabled or Not Installed
Direction
Attachment Valve #2 Flow Disabled or Not Installed L/min
Setting
Attachment Valve #2 Multi- Disabled or Not Installed L/min
Operation Additional Flow
Valve #2 Nominal Pressure Disabled or Not Installed kPa
Attachment Valve #2 Maximum 4000 kPa
Extend Pressure
Attachment Valve #2 Maximum Disabled or Not Installed kPa
Retract Pressure
Attachment Valve #2 Open 0.20 sec
Time
Attachment Valve #2 Close 0.20 sec
Time
Attachment Valve #2 Tool Flow Disabled or Not Installed
Direction
Attachment Valve #3 Flow Disabled or Not Installed L/min
Setting
Attachment Valve #3 Multi- Disabled or Not Installed L/min
Operation Additional Flow
Valve #3 Nominal Pressure Disabled or Not Installed kPa
Attachment Valve #3 Maximum Disabled or Not Installed kPa
Extend Pressure
Attachment Valve #3 Maximum Disabled or Not Installed kPa
Retract Pressure
Attachment Valve #3 Open Disabled or Not Installed sec
Time
Attachment Valve #3 Close Disabled or Not Installed sec
Time
Attachment Valve #3 Tool Flow Disabled or Not Installed
Direction
Attachment Valve #4 Flow Disabled or Not Installed L/min
Setting
Attachment Valve #4 Multi- Disabled or Not Installed L/min
Operation Additional Flow
Valve #4 Nominal Pressure Disabled or Not Installed kPa
Attachment Valve #4 Maximum Disabled or Not Installed kPa
Extend Pressure
Attachment Valve #4 Maximum Disabled or Not Installed kPa
Retract Pressure
Attachment Valve #4 Open Disabled or Not Installed sec
Time
Attachment Valve #4 Close Disabled or Not Installed sec
Time
Attachment Valve #4 Tool Flow Disabled or Not Installed
Direction

Tool Configuration - Machine Control 330D/336D (M4T01049)


Description Value Unit
Tool Program Name 0
Maximum Throttle Dial 10
Minimum Throttle Dial Position 1
Underspeed Enable Enabled
Two Pump Flow Combine Disabled
Enable
Initial Tool Program Medium Disabled or Not Installed %
Pressure Circuit Main Pump
Torque Reduction
Total Tool Program Medium Disabled or Not Installed %
Pressure Circuit Main Pump
Torque Reduction
One Way/ Two Way Valve Disabled or Not Installed
Mode
Variable Relief Valve #1 Disabled or Not Installed kPa
Pressure
Variable Relief Valve #2 Disabled or Not Installed kPa
Pressure
F2 Type Valve Max Flow Disabled or Not Installed kPa
Derate Pressure
F2 Type Valve Flow Derate Disabled or Not Installed kPa
Start Pressure
F2 Type Valve Flow Derate End Disabled or Not Installed kPa
Pressure
Multiple Operation Maximum 4000 kPa
Extend Pilot Pressure for
Attachment Valve #1
Multiple Operation Maximum Disabled or Not Installed kPa
Retract Pilot Pressure for
Attachment Valve #1
Multiple Operation Maximum 4000 kPa
Extend Pilot Pres for Combined
Attachment Valve
Multiple Operation Maximum Disabled or Not Installed kPa
Retract Pilot Pres for Combined
Attachment Valve
Hydraulic Temperature High 126.0 Deg C
Warning Event Threshold
Attachment Valve #1 Flow 0 L/min
Setting
Attachment Valve #1 Multi- 0 L/min
Operation Additional Flow
Valve #1 Nominal Pressure 16000 kPa
Attachment Valve #1 Maximum 4000 kPa
Extend Pressure
Attachment Valve #1 Maximum Disabled or Not Installed kPa
Retract Pressure
Attachment Valve #1 Open 0.20 sec
Time
Attachment Valve #1 Close 0.20 sec
Time
Attachment Valve #1 Tool Flow Disabled or Not Installed
Direction
Attachment Valve #2 Flow Disabled or Not Installed L/min
Setting
Attachment Valve #2 Multi- Disabled or Not Installed L/min
Operation Additional Flow
Valve #2 Nominal Pressure Disabled or Not Installed kPa
Attachment Valve #2 Maximum 4000 kPa
Extend Pressure
Attachment Valve #2 Maximum Disabled or Not Installed kPa
Retract Pressure
Attachment Valve #2 Open 0.20 sec
Time
Attachment Valve #2 Close 0.20 sec
Time
Attachment Valve #2 Tool Flow Disabled or Not Installed
Direction
Attachment Valve #3 Flow Disabled or Not Installed L/min
Setting
Attachment Valve #3 Multi- Disabled or Not Installed L/min
Operation Additional Flow
Valve #3 Nominal Pressure Disabled or Not Installed kPa
Attachment Valve #3 Maximum Disabled or Not Installed kPa
Extend Pressure
Attachment Valve #3 Maximum Disabled or Not Installed kPa
Retract Pressure
Attachment Valve #3 Open Disabled or Not Installed sec
Time
Attachment Valve #3 Close Disabled or Not Installed sec
Time
Attachment Valve #3 Tool Flow Disabled or Not Installed
Direction
Attachment Valve #4 Flow Disabled or Not Installed L/min
Setting
Attachment Valve #4 Multi- Disabled or Not Installed L/min
Operation Additional Flow
Valve #4 Nominal Pressure Disabled or Not Installed kPa
Attachment Valve #4 Maximum Disabled or Not Installed kPa
Extend Pressure
Attachment Valve #4 Maximum Disabled or Not Installed kPa
Retract Pressure
Attachment Valve #4 Open Disabled or Not Installed sec
Time
Attachment Valve #4 Close Disabled or Not Installed sec
Time
Attachment Valve #4 Tool Flow Disabled or Not Installed
Direction

Tool Configuration - Machine Control 330D/336D (M4T01049)


Description Value Unit
Tool Program Name 0
Maximum Throttle Dial 10
Minimum Throttle Dial Position 1
Underspeed Enable Enabled
Two Pump Flow Combine Disabled
Enable
Initial Tool Program Medium Disabled or Not Installed %
Pressure Circuit Main Pump
Torque Reduction
Total Tool Program Medium Disabled or Not Installed %
Pressure Circuit Main Pump
Torque Reduction
One Way/ Two Way Valve Disabled or Not Installed
Mode
Variable Relief Valve #1 Disabled or Not Installed kPa
Pressure
Variable Relief Valve #2 Disabled or Not Installed kPa
Pressure
F2 Type Valve Max Flow Disabled or Not Installed kPa
Derate Pressure
F2 Type Valve Flow Derate Disabled or Not Installed kPa
Start Pressure
F2 Type Valve Flow Derate End Disabled or Not Installed kPa
Pressure
Multiple Operation Maximum 4000 kPa
Extend Pilot Pressure for
Attachment Valve #1
Multiple Operation Maximum Disabled or Not Installed kPa
Retract Pilot Pressure for
Attachment Valve #1
Multiple Operation Maximum 4000 kPa
Extend Pilot Pres for Combined
Attachment Valve
Multiple Operation Maximum Disabled or Not Installed kPa
Retract Pilot Pres for Combined
Attachment Valve
Hydraulic Temperature High 126.0 Deg C
Warning Event Threshold
Attachment Valve #1 Flow 0 L/min
Setting
Attachment Valve #1 Multi- 0 L/min
Operation Additional Flow
Valve #1 Nominal Pressure 16000 kPa
Attachment Valve #1 Maximum 4000 kPa
Extend Pressure
Attachment Valve #1 Maximum Disabled or Not Installed kPa
Retract Pressure
Attachment Valve #1 Open 0.20 sec
Time
Attachment Valve #1 Close 0.20 sec
Time
Attachment Valve #1 Tool Flow Disabled or Not Installed
Direction
Attachment Valve #2 Flow Disabled or Not Installed L/min
Setting
Attachment Valve #2 Multi- Disabled or Not Installed L/min
Operation Additional Flow
Valve #2 Nominal Pressure Disabled or Not Installed kPa
Attachment Valve #2 Maximum 4000 kPa
Extend Pressure
Attachment Valve #2 Maximum Disabled or Not Installed kPa
Retract Pressure
Attachment Valve #2 Open 0.20 sec
Time
Attachment Valve #2 Close 0.20 sec
Time
Attachment Valve #2 Tool Flow Disabled or Not Installed
Direction
Attachment Valve #3 Flow Disabled or Not Installed L/min
Setting
Attachment Valve #3 Multi- Disabled or Not Installed L/min
Operation Additional Flow
Valve #3 Nominal Pressure Disabled or Not Installed kPa
Attachment Valve #3 Maximum Disabled or Not Installed kPa
Extend Pressure
Attachment Valve #3 Maximum Disabled or Not Installed kPa
Retract Pressure
Attachment Valve #3 Open Disabled or Not Installed sec
Time
Attachment Valve #3 Close Disabled or Not Installed sec
Time
Attachment Valve #3 Tool Flow Disabled or Not Installed
Direction
Attachment Valve #4 Flow Disabled or Not Installed L/min
Setting
Attachment Valve #4 Multi- Disabled or Not Installed L/min
Operation Additional Flow
Valve #4 Nominal Pressure Disabled or Not Installed kPa
Attachment Valve #4 Maximum Disabled or Not Installed kPa
Extend Pressure
Attachment Valve #4 Maximum Disabled or Not Installed kPa
Retract Pressure
Attachment Valve #4 Open Disabled or Not Installed sec
Time
Attachment Valve #4 Close Disabled or Not Installed sec
Time
Attachment Valve #4 Tool Flow Disabled or Not Installed
Direction

Tool Configuration - Machine Control 330D/336D (M4T01049)


Description Value Unit
Tool Program Name 0
Maximum Throttle Dial 10
Minimum Throttle Dial Position 1
Underspeed Enable Enabled
Two Pump Flow Combine Disabled
Enable
Initial Tool Program Medium Disabled or Not Installed %
Pressure Circuit Main Pump
Torque Reduction
Total Tool Program Medium Disabled or Not Installed %
Pressure Circuit Main Pump
Torque Reduction
One Way/ Two Way Valve Disabled or Not Installed
Mode
Variable Relief Valve #1 Disabled or Not Installed kPa
Pressure
Variable Relief Valve #2 Disabled or Not Installed kPa
Pressure
F2 Type Valve Max Flow Disabled or Not Installed kPa
Derate Pressure
F2 Type Valve Flow Derate Disabled or Not Installed kPa
Start Pressure
F2 Type Valve Flow Derate End Disabled or Not Installed kPa
Pressure
Multiple Operation Maximum 4000 kPa
Extend Pilot Pressure for
Attachment Valve #1
Multiple Operation Maximum Disabled or Not Installed kPa
Retract Pilot Pressure for
Attachment Valve #1
Multiple Operation Maximum 4000 kPa
Extend Pilot Pres for Combined
Attachment Valve
Multiple Operation Maximum Disabled or Not Installed kPa
Retract Pilot Pres for Combined
Attachment Valve
Hydraulic Temperature High 126.0 Deg C
Warning Event Threshold
Attachment Valve #1 Flow 0 L/min
Setting
Attachment Valve #1 Multi- 0 L/min
Operation Additional Flow
Valve #1 Nominal Pressure 16000 kPa
Attachment Valve #1 Maximum 4000 kPa
Extend Pressure
Attachment Valve #1 Maximum Disabled or Not Installed kPa
Retract Pressure
Attachment Valve #1 Open 0.20 sec
Time
Attachment Valve #1 Close 0.20 sec
Time
Attachment Valve #1 Tool Flow Disabled or Not Installed
Direction
Attachment Valve #2 Flow Disabled or Not Installed L/min
Setting
Attachment Valve #2 Multi- Disabled or Not Installed L/min
Operation Additional Flow
Valve #2 Nominal Pressure Disabled or Not Installed kPa
Attachment Valve #2 Maximum 4000 kPa
Extend Pressure
Attachment Valve #2 Maximum Disabled or Not Installed kPa
Retract Pressure
Attachment Valve #2 Open 0.20 sec
Time
Attachment Valve #2 Close 0.20 sec
Time
Attachment Valve #2 Tool Flow Disabled or Not Installed
Direction
Attachment Valve #3 Flow Disabled or Not Installed L/min
Setting
Attachment Valve #3 Multi- Disabled or Not Installed L/min
Operation Additional Flow
Valve #3 Nominal Pressure Disabled or Not Installed kPa
Attachment Valve #3 Maximum Disabled or Not Installed kPa
Extend Pressure
Attachment Valve #3 Maximum Disabled or Not Installed kPa
Retract Pressure
Attachment Valve #3 Open Disabled or Not Installed sec
Time
Attachment Valve #3 Close Disabled or Not Installed sec
Time
Attachment Valve #3 Tool Flow Disabled or Not Installed
Direction
Attachment Valve #4 Flow Disabled or Not Installed L/min
Setting
Attachment Valve #4 Multi- Disabled or Not Installed L/min
Operation Additional Flow
Valve #4 Nominal Pressure Disabled or Not Installed kPa
Attachment Valve #4 Maximum Disabled or Not Installed kPa
Extend Pressure
Attachment Valve #4 Maximum Disabled or Not Installed kPa
Retract Pressure
Attachment Valve #4 Open Disabled or Not Installed sec
Time
Attachment Valve #4 Close Disabled or Not Installed sec
Time
Attachment Valve #4 Tool Flow Disabled or Not Installed
Direction

Tool Configuration - Machine Control 330D/336D (M4T01049)


Description Value Unit
Tool Program Name 0
Maximum Throttle Dial 10
Minimum Throttle Dial Position 1
Underspeed Enable Enabled
Two Pump Flow Combine Disabled
Enable
Initial Tool Program Medium Disabled or Not Installed %
Pressure Circuit Main Pump
Torque Reduction
Total Tool Program Medium Disabled or Not Installed %
Pressure Circuit Main Pump
Torque Reduction
One Way/ Two Way Valve Disabled or Not Installed
Mode
Variable Relief Valve #1 Disabled or Not Installed kPa
Pressure
Variable Relief Valve #2 Disabled or Not Installed kPa
Pressure
F2 Type Valve Max Flow Disabled or Not Installed kPa
Derate Pressure
F2 Type Valve Flow Derate Disabled or Not Installed kPa
Start Pressure
F2 Type Valve Flow Derate End Disabled or Not Installed kPa
Pressure
Multiple Operation Maximum 4000 kPa
Extend Pilot Pressure for
Attachment Valve #1
Multiple Operation Maximum Disabled or Not Installed kPa
Retract Pilot Pressure for
Attachment Valve #1
Multiple Operation Maximum 4000 kPa
Extend Pilot Pres for Combined
Attachment Valve
Multiple Operation Maximum Disabled or Not Installed kPa
Retract Pilot Pres for Combined
Attachment Valve
Hydraulic Temperature High 126.0 Deg C
Warning Event Threshold
Attachment Valve #1 Flow 0 L/min
Setting
Attachment Valve #1 Multi- 0 L/min
Operation Additional Flow
Valve #1 Nominal Pressure 16000 kPa
Attachment Valve #1 Maximum 4000 kPa
Extend Pressure
Attachment Valve #1 Maximum Disabled or Not Installed kPa
Retract Pressure
Attachment Valve #1 Open 0.20 sec
Time
Attachment Valve #1 Close 0.20 sec
Time
Attachment Valve #1 Tool Flow Disabled or Not Installed
Direction
Attachment Valve #2 Flow Disabled or Not Installed L/min
Setting
Attachment Valve #2 Multi- Disabled or Not Installed L/min
Operation Additional Flow
Valve #2 Nominal Pressure Disabled or Not Installed kPa
Attachment Valve #2 Maximum 4000 kPa
Extend Pressure
Attachment Valve #2 Maximum Disabled or Not Installed kPa
Retract Pressure
Attachment Valve #2 Open 0.20 sec
Time
Attachment Valve #2 Close 0.20 sec
Time
Attachment Valve #2 Tool Flow Disabled or Not Installed
Direction
Attachment Valve #3 Flow Disabled or Not Installed L/min
Setting
Attachment Valve #3 Multi- Disabled or Not Installed L/min
Operation Additional Flow
Valve #3 Nominal Pressure Disabled or Not Installed kPa
Attachment Valve #3 Maximum Disabled or Not Installed kPa
Extend Pressure
Attachment Valve #3 Maximum Disabled or Not Installed kPa
Retract Pressure
Attachment Valve #3 Open Disabled or Not Installed sec
Time
Attachment Valve #3 Close Disabled or Not Installed sec
Time
Attachment Valve #3 Tool Flow Disabled or Not Installed
Direction
Attachment Valve #4 Flow Disabled or Not Installed L/min
Setting
Attachment Valve #4 Multi- Disabled or Not Installed L/min
Operation Additional Flow
Valve #4 Nominal Pressure Disabled or Not Installed kPa
Attachment Valve #4 Maximum Disabled or Not Installed kPa
Extend Pressure
Attachment Valve #4 Maximum Disabled or Not Installed kPa
Retract Pressure
Attachment Valve #4 Open Disabled or Not Installed sec
Time
Attachment Valve #4 Close Disabled or Not Installed sec
Time
Attachment Valve #4 Tool Flow Disabled or Not Installed
Direction

Tool Configuration - Machine Control 330D/336D (M4T01049)


Description Value Unit
Tool Program Name 0
Maximum Throttle Dial 10
Minimum Throttle Dial Position 1
Underspeed Enable Enabled
Two Pump Flow Combine Disabled
Enable
Initial Tool Program Medium Disabled or Not Installed %
Pressure Circuit Main Pump
Torque Reduction
Total Tool Program Medium Disabled or Not Installed %
Pressure Circuit Main Pump
Torque Reduction
One Way/ Two Way Valve Disabled or Not Installed
Mode
Variable Relief Valve #1 Disabled or Not Installed kPa
Pressure
Variable Relief Valve #2 Disabled or Not Installed kPa
Pressure
F2 Type Valve Max Flow Disabled or Not Installed kPa
Derate Pressure
F2 Type Valve Flow Derate Disabled or Not Installed kPa
Start Pressure
F2 Type Valve Flow Derate End Disabled or Not Installed kPa
Pressure
Multiple Operation Maximum 4000 kPa
Extend Pilot Pressure for
Attachment Valve #1
Multiple Operation Maximum Disabled or Not Installed kPa
Retract Pilot Pressure for
Attachment Valve #1
Multiple Operation Maximum 4000 kPa
Extend Pilot Pres for Combined
Attachment Valve
Multiple Operation Maximum Disabled or Not Installed kPa
Retract Pilot Pres for Combined
Attachment Valve
Hydraulic Temperature High 126.0 Deg C
Warning Event Threshold
Attachment Valve #1 Flow 0 L/min
Setting
Attachment Valve #1 Multi- 0 L/min
Operation Additional Flow
Valve #1 Nominal Pressure 16000 kPa
Attachment Valve #1 Maximum 4000 kPa
Extend Pressure
Attachment Valve #1 Maximum Disabled or Not Installed kPa
Retract Pressure
Attachment Valve #1 Open 0.20 sec
Time
Attachment Valve #1 Close 0.20 sec
Time
Attachment Valve #1 Tool Flow Disabled or Not Installed
Direction
Attachment Valve #2 Flow Disabled or Not Installed L/min
Setting
Attachment Valve #2 Multi- Disabled or Not Installed L/min
Operation Additional Flow
Valve #2 Nominal Pressure Disabled or Not Installed kPa
Attachment Valve #2 Maximum 4000 kPa
Extend Pressure
Attachment Valve #2 Maximum Disabled or Not Installed kPa
Retract Pressure
Attachment Valve #2 Open 0.20 sec
Time
Attachment Valve #2 Close 0.20 sec
Time
Attachment Valve #2 Tool Flow Disabled or Not Installed
Direction
Attachment Valve #3 Flow Disabled or Not Installed L/min
Setting
Attachment Valve #3 Multi- Disabled or Not Installed L/min
Operation Additional Flow
Valve #3 Nominal Pressure Disabled or Not Installed kPa
Attachment Valve #3 Maximum Disabled or Not Installed kPa
Extend Pressure
Attachment Valve #3 Maximum Disabled or Not Installed kPa
Retract Pressure
Attachment Valve #3 Open Disabled or Not Installed sec
Time
Attachment Valve #3 Close Disabled or Not Installed sec
Time
Attachment Valve #3 Tool Flow Disabled or Not Installed
Direction
Attachment Valve #4 Flow Disabled or Not Installed L/min
Setting
Attachment Valve #4 Multi- Disabled or Not Installed L/min
Operation Additional Flow
Valve #4 Nominal Pressure Disabled or Not Installed kPa
Attachment Valve #4 Maximum Disabled or Not Installed kPa
Extend Pressure
Attachment Valve #4 Maximum Disabled or Not Installed kPa
Retract Pressure
Attachment Valve #4 Open Disabled or Not Installed sec
Time
Attachment Valve #4 Close Disabled or Not Installed sec
Time
Attachment Valve #4 Tool Flow Disabled or Not Installed
Direction

Monitor
Parameter Value
ECM Serial Number 107J0345AJ
Personality Module Part Number 3495410-00