Sunteți pe pagina 1din 2

TP48200A Outdoor System

Introduction
TP48200A is an AC/DC outdoor power system that configures 48V/50A rectifier modules to
supply rated of 200A output current. The system has excellent performance such as wide
range of AC input voltage, high power efficiency, surge protection, temperature control,
intelligent battery management, and remote monitoring. The TP48200A is used in class B
environment and is optimized for various outdoor scenarios.

General
1200 (H,47.24in.excluding the pedestal) 700(W,27.56in.)800
Dimensions of cabinet
(D,31.49in.) mm
Dimensions of pedestal 100 (H,3.94in.)700(W,27.56in.)800 (D,31.49in.) mm
Weight 100Kg (without rectifier modules)
Rated capacity 200A

Feature Number of rectifier 2~4


Cooling mode/power Direct ventilation/Rated power1400W,Maximum power1700W
The system complies with the CE standards,
the power distribution components comply Installation mode Wall-mounted; ground installation
with the CE and 3C, the PSU complies with
the UL, CE and TUV , the PMU complies User space/useful depth 8U/530mm
with CE, YD/T 1058-2007, and RoHS
Protection level IP45
High surge protection Level: Class B
Environmental specification
High power efficiency of rectifier : >96%
Operating
Wide range of AC input voltage (85~300V - 33 ~ +50
temperature
AC)
Operating humidity 5% ~ 95% (non-condensing)
Super temperature performance for
rectifiers with the range -40 ~ +75 0 ~4000 m (at the altitude from 2000m to 4000m, the temperature
Altitude
Intelligent temperature control, ensures the declines by 1 for each increase of 200m in altitude)
system to work stably
Surge protection
Intelligent battery management, prolong
battery lifetime Class B surge protection
Easy installation: modules are hot- SPD for AC input Standard surge discharge current: 30kA, 8/20s
swappable, and enough user space Maximum surge discharge current: 60kA, 8/20s

Remote monitoring, reduce operation Differential mode: 10kA, 8/20s


expenditure SPD for DC output
Common mode: 20kA, 8/20s

SPD for signal Differential mode: 3kA, 8/20s


input Common mode: 15kA, 8/20s

%
100
Direct ventilation unit

95

90

85

80 A
0 5 10 15 20 25 30 35 40 45 50 55

50A rectifier efficiency curve

Fan speed line chart

www.huawei.com
TP48200A Outdoor System

AC distribution
Three phase five line mode (L1,L2,L3,N,PE) [single phase three line
AC input mode
mode (L, N, and PE) and dual lines input mode are available]

AC input voltage 85~300VAC, rated value 220VAC(L-N)

AC input frequency 45~65Hz, rated value 50/60Hz

Power factor 0.99

Main AC input 1 x 63 A /3P(MCB) ; class-B surge protection ; D.G connector


1 x 10 A (MCB) with leakage protection for a maintenance socket
AC output port
switch (optional)

DC distribution
Output voltage 43.2~58VDC, default value 53.5VDC

Rated output 12000W, when 50A high efficiency modules configured


power 11600W, when 50A standard efficiency modules configured
Power DCDB Battery branch 2 x 125A (MCB)
meter
LLVD 2 x 100A MCB, 6 x 20A MCB

BLVD 1x 32A MCB(TMC), 4 x 16A MCB(one for fan), 1 x 10A MCB(BBU)

Rectifier module
Input voltage 85~300VAC, rated value 220VAC

Input frequency 45~65Hz, rated value 50/60Hz

Output voltage 42~58VDC, rated value 53.5VDC

up to 96% (48V/50A high efficiency rectifier)


Efficiency
up to 92% (48V/50A standard efficiency rectifier)
Rectifier module

Maximum output 3000W (48V/50A high efficiency rectifier)


power 2900W (48V/50A standard efficiency rectifier)

Monitoring unit

Battery floating/equalizing charge management


LLVD & BLVD
Intelligent battery Battery discharging test
management Battery remaining capacity testing
Battery temperature compensation
Battery disconnect / load shutdown against over temperature
Power monitoring unit
Real time alarms Real time alarms through buzzer and indicator

Rectifier module voltage/current regulation


Startup and shutdown of the rectifier module
System control
Connect or disconnect batteries
Connect or disconnect load

Dormancy According to the load power, the power system automatically starts the
management dormancy mode of rectifier modules to save power

Supports dry contacts alarms output


Communicates with Huawei main equipment through the
Remote monitoring
RS232/422/485. In addition, the SNMP(optional) communication
module enables the monitoring over the Ethernet.

The information in this document may contain predictive statements including, without limitation, Huawei Industrial Base
statements regarding the future financial and operating results, future product portfolio, new Bantian, Longgang
technology, etc. There are a number of factors that could cause actual results and developments
Shenzhen 518129, P.R.China
to differ materially from those expressed or implied in the predictive statements. Therefore, such
Tel: +86-755-28780808
information is provided for reference purpose only and constitutes neither an offer nor an
www.huawei.com
acceptance. Huawei may change the information at any time without notice.

S-ar putea să vă placă și