Documente Academic
Documente Profesional
Documente Cultură
VIPA
OTHER SYMBOLS:
biuro@rgbelektronika.pl
+48 71 325 15 05
www.rgbautomatyka.pl
www.rgbautomatyka.pl
www.rgbelektronika.pl
YOUR
PARTNER IN
MAINTENANCE
Repair this product with RGB ELEKTRONIKA ORDER A DIAGNOSIS
LINEAR
ENCODERS PLC
SYSTEMS
INDUSTRIAL
COMPUTERS
ENCODERS CNC
CONTROLS
SERVO AMPLIFIERS
MOTORS
CNC
MACHINES
OUR SERVICES
POWER
SUPPLIERS
OPERATOR
SERVO
PANELS
DRIVERS
At our premises in Wrocaw, we have a fully equipped servicing facility. Here we perform all the repair
works and test each later sold unit. Our trained employees, equipped with a wide variety of tools and
having several testing stands at their disposal, are a guarantee of the highest quality service.
System overview
Output modules In the following you will get an overview over the digital output modules that
SM 322 are available at VIPA:
DC 24V output
modules
DO 8xDC24V DO 16xDC24V DO 16xDC24V
2A 1A 2A
1L+ 1L+ 1L+
. .0 .0
.0 .1 .1
.2 .2
.1 .3 .3
.4 .4
.2 .5 .5
.6 .6
.3 .7 .7
F F F
DO 16xDC24V +0 DO 32xDC24V
0,5A L+ 1A
1/3L+
0 .0
1 .1
2 .2
3 .3
4 .4
5 .5
6 .6
7 .7
A01 1/3 F
SM322 SM322
+1
A01 2/4L+
0 .0
1 .1
2 .2
3 .3
4 .4
5 .5
6 .6
7 .7
X 2
3 4
F X 2
2/4 F
3 4
VIPA 322-1BH60 VIPA 322-1BL00
AC 120/230V
Output module
DO8xAC120/230V
2A
SF
.0 .4
.1 .5
SM322
.2 .6
.3 .7
X 2
3 4
VIPA 322-5FF00
Relay output
module
DO 16xRELAIS
.0
.1
.2
.3
.4
.5
.6
.7
SM322
.0
.1
.2
.3
.4
.5
.6
.7
X 2
3 4
VIPA 322-1HH00
Description The digital output module collects the binary control signals from the
superordinated bus system and transmits them isolated to the process
level. The module has to be provided with 24V via the front slot. It has 8
channels and their status is monitored via LEDs.
1 1
2
1L+ 4 [2] flap with labeling strip
3 3
4
5
=
2
6
7
8
[3] contact bar
9
10
1M
11
12
2L+
[4] flap opened with
inner label
13
14
15
16 =
17
18
19
20
2M
Pin assignment
Circuit diagram
Status monitor
1 1L+
1 Supply voltage 2
DO 8xDC24V
2A
1L+, 2L+ LED (green)
1L+
DC 24V 3 supply voltage is on
4 0
3 Output Q+0.0 5
5 Output Q+0.1 6 = .1
.0 ... .7 LEDs (green)
7
7 Output Q+0.2 8 .2 Q+0.0 to Q+0.7
9
9 Output Q+0.3 10
.3 As soon as an output is
10 Ground 1 1M F
active, the according
SM322
LED is activated
11 Supply voltage 11 2L+
2L+
DC 24V 12
13 4 F LED (red)
13 Output Q+0.4 14
15 .5 Error when overload or
15 Output Q+0.5 16 =
17 .6
short circuits
17 Output Q+0.6
18
19 Output Q+0.7 19
X 2
.7
20 3 4 F
20 Ground 2 2M VIPA 322-1BF01
Bus
LED
DC 24V
Mintern
Technical data
Module name VIPA 322-1BF01
Dimensions and weight
Dimensions WxHxD 40x125x120mm
Weight 180g
Data for specific module
Number of outputs 8
Length of cable
- unshielded 600m
Programming specifications
Output data 1Byte
Voltages, Currents, Potentials
Rated load voltage L+ DC 24V
Total current of the outputs (per group) 8A
Isolation
- between channels and backplane bus yes
- between the channel groups yes
in groups of 4
Permitted potential difference
- between the difference circuit DC 75V / AC 60V
Insulation tested with DC 500V
Current consumption
- from the backplane bus 65mA
- from the load voltage L+ (without load) 68mA
Power dissipation of the module 7.5W
Status, Interrupts, Diagnostics
Status display green LED per channel
Group error display red F-LED per group
Data for selecting an actuator
Output voltage
- at signal "1" DC 24V
Output current
- at signal "1"
Rated value 2A
Output delay resistive load
- from "0" to "1" 150s
- from "1" to "0" 76s
Lamp load max. 10W
Parallel connection of 2 outputs possible
- for redundant triggering of a load only outputs of same group
- for increase performance only outputs of same group
Switch rate max.
- for resistive load 1kHz
- for inductive load (IEC 947-5-1, DC 13) 0.5Hz
- lamp load 1Hz
Limit of the inductive circuit interruption voltage typ. L+ (-52V)
Short-circuit protection of the output yes, electronic
- Threshold on 3A
Description The digital output module collects the binary control signals from the
superordinated bus system and transmits them isolated to the process
level. The module has to be provided with 24V via the front slot. It has 16
channels and their status is monitored via LEDs.
1
3
1
2
1L+ 4 [2] flap with labeling strip
3
4
5
6 =
2
7
8
9
[3] contact bar
10
1M
11
12
13
2L+
[4] flap opened with
14
15
16 =
inner label
17
18
19
20
2M
Pin assignment
Circuit diagram
Status monitor
1 1L+
1 Supply voltage 2
DO 16xDC24V
1A
1L+
1L+, 2L+ LED (green)
DC 24V 3 .0
supply voltage is on
4 .1
2 Output Q+0.0 5 .2
6 = .3
. . .4 .0 ... .7 LEDs (green)
7
. . .5
8
.6 Q+0.0 to Q+1.7
9 Output Q+0.7 9
.7
10 F As soon as an output is
10 Ground 1 1M
SM322 active, the according
11 Supply voltage 11 2L+ 2L+ LED is activated
DC 24V 12
13
.0
.1
12 Output Q+1.0 14 .2
.3
F LED (red)
15
. . 16 = .4
Error when overload or
.5
. . 17
18
.6 short circuits
19 Output Q+1.7 19 X 2
.7
F
3 4
20
20 Ground 2 2M
VIPA 322-1BH01
Bus
LED
DC 24V
Mintern
Technical Data
Description The digital output module collects the binary control signals from the
superordinated bus system and transmits them isolated to the process
level. The module has to be provided with 24V via the front slot. It has 16
channels and their status is monitored via LEDs.
1
3
1
2
1L+ 4 [2] flap with labeling strip
3
4
5
6 =
2
7
8
9
[3] contact bar
10
1M
11
12
13
2L+
[4] flap opened with
14
15
16 =
inner label
17
18
19
20
2M
Pin assignment
Circuit diagram
Status monitor
1 1L+
1 Supply voltage 2
DO 16xDC24V
2A
1L+
1L+, 2L+ LED (green)
DC 24V 3 .0
supply voltage is on
4 .1
2 Output Q+0.0 5 .2
6 = .3
. . .4 .0 ... .7 LEDs (green)
7
. . .5
8
.6 Q+0.0 to Q+1.7
9 Output Q+0.7 9
.7
10
F As soon as an output is
10 Ground 1 1M
SM322 active, the according
11 Supply voltage 11 2L+ 2L+ LED is turned on
12
DC 24V 13
.0
.1
12 Output Q+1.0 14 .2
.3
F LED (red)
15
. . 16 = .4
Error when overload or
.5
. . 17
18
.6 short circuits
19 Output Q+1.7 19 X 2
.7
F
3 4
20
20 Ground 2 2M
VIPA 322-1BH41
Bus
LED
DC 24V
Mintern
Technical Data
2
6
7
8
[3] switch bar
9
10
11
3 12
13
14
= [4] contact bar
15
16
17
18
19
20
[5] flap opened with
M
inner label
Pin assignment
Circuit diagram
Status monitor
L+ DO 16xDC24V +0
1 Supply voltage 1
2
0,5A
L+
L+ LED (green)
DC 24V 3 0
supply voltage is on
1
4
2 Output Q+0.0 5
2
3
. . 6 4
7 5 .0 ... .7 LEDs (green)
. . 8 6
9 7 Q+0.0 to Q+1.7
9 Output Q+0.7 10 10A
As soon as an output is
10 Input for Q.x="1"
11 +1
10A active, the according
11 n.c. 12 0 LED is turned on
13 = 1
12 Output Q+1.0 14 2
15 3
. .
. .
16 4
5
F LED (red)
17
19 Output O+1.7
18 6
7
Error when overload or
19
20
X 2
3 4
F short circuits
20 Ground M
VIPA 322-1BH60
Bus
Minternal
DC 24V
LED
Deployment Please regard that the module is installed as 323-1BL00. You are allowed
to request the switch position of the according channel via the input word.
For this is valid:
Note!
By connecting DC 24V at the input (Pin 10), all outputs are set to "1".
This input cannot be evaluated by the PLC user program.
Technical Data
Description The digital output module collects the binary control signals from the
superordinated bus system and transmits them isolated to the process
level. The module has to be provided with 24V via the front slot. It has 16
channels and their status is monitored via LEDs.
1
3
1 1L+ 21 3L+
2 22
4 [2] flap with labeling strip
3 23
4 24
5 25
= 26 =
11 2L+ 31 4L+
12 32
[4] flap opened with
13 33
14
15
34
35
= 36 =
inner label
16
17 37
18 38
19 39
20 40
2M 4M
Pin assignment
Status monitor
11 2L+ 31 4L+
12 32
13 33
14 34
15 35
= =
16 36
17 37
18 38
19 39
20 40
2M 4M
Numeric From the application level to the hardware level the data is stored in
representation Motorola-Format, i.e. "ready for reading".
The following picture shows the output of the number 287454020dez res.
11223344hex on the outputs of the 32pin output modules
Byte .0
10001000
11001100
.1
SM322
+1 +3
2L+ 4L
.0
Process image: .1
01000100
00100010
Address 0 1 2 3 .2
.3
11h 22h 33h 44h .4
.5
.6
0 10001000b .7
1 01000100b F
2 11001100b
3 00100010b
Technical Data
Description The digital output module collects the binary control signals from the
superordinated bus system and transmits them isolated to the process
level. It has 8 channels and their status is monitored via LEDs.
Properties 8 outputs, isolated between the channels and to the back plane bus
Rated load voltage AC 120/230V
Output current per channel 2A
Suitable for AC solenoid valves, contactors, motor starters, fractional
h.p. motors and indicator lights
Group error display
Channel-specific status LEDs
Programmable substitute value output
10 30
[4] flap opened with
11 31 inner label
14 34
17 37
20 40
Pin assignment
Status monitor
DO8xAC120/230V
1 Rated load voltage 1L 2A
SF LED (red)
SF
4 Q+0.0 .0 .4
Group errror LED,
7 Rated load voltage 2L error if module is not
10 Q+0.1 supplied with parameters
by the CPU
11 Rated load voltage 3L .1 .5
14 Q+0.2
.0 ... .7 LED (green)
17 Rated load voltage 4L
Q+0.0 to Q+0.7
20 Q+0.3
SM322 As soon as an output is
21 Rated load voltage 5L
active, the according LED
24 Q+0.4 .2 .6 is turned on
27 Rated load voltage 6L
30 Q+0.5
31 Rated load voltage 7L .3 .7
34 Q+0.6
37 Rated load voltage 8L X 2
3 4
40 Q+0.7 VIPA 322-5FF00
4 24
Optocoupler
7 27
Bus
10 30 AC 120/230V
Mintern
11 31
14 34
17 37
20 40
Caution!
The outputs must be protected by a fast-acting 3.15A, AC 250V fuse.
When mounted in a hazardous area, the fuse may only be removed by a
tool.
Parameterization
Parameters The following parameters can be adjusted at the digital output modules:
Reaction at CPU-STOP
Switch substitute value "1"
Parameterization If the module gets parameters, which are not supported by the module, for
during run time by example a current module is to be configured as a voltage module, these
means of SFCs parameters are interpreted as wrong parameters and an error is initialized.
At the parameterization, a 4byte long parameter area is set in the record
set 1. Deploying the SFCs 56, 57 and the SFB 53, you may alter
parameters during run time and transfer them to the module.
Parameter
Record set 1
Record set 1 (Byte 0 to 3): Default value
Byte Bit 7 ... Bit 0
0 Reaction to CPU Stop 00h
Bit 0: Keep last valid value
Bit 1: Substitute a value
Bit 6: reserved
Bit 7: reserved
1 Substitute value 00h
Bit 0: Substitute value "1" on channel 0
Bit 1: Substitute value "1" on channel 1
Bit 2: Substitute value "1" on channel 2
Bit 3: Substitute value "1" on channel 3
Bit 4: Substitute value "1" on channel 4
Bit 5: Substitute value "1" on channel 5
Bit 5: Substitute value "1" on channel 6
Bit 7: Substitute value "1" on channel 7
2 not relevant 00h
3 not relevant 00h
Note!
You should only enable the parameters in byte 0, "Hold last valid value"
and "Enable substitute value" as an alternative.
Reaction to Here the module reaction at CPU-STOP may be set. There are the
CPU-Stop following possibilities:
Keep last valid value
The value of each channel is freezed when the CPU is stopped
Substitute a value
At CPU-STOP each channel is substituded by a value which may be
assigned by byte 1.
Technical Data
322-1HH00 - DO 16xRelay
Description The relay output module collects the binary control signals from the
superordinated bus system and transmits them via relay outputs to the
process level. The module electronics are provided via the back panel bus.
It has 16 channels working as switches, and their status is monitored via
LEDs.
Pin assignment
Status monitor
Pin Assignment LED Description
1 1L1 DO 16xRELAIS
.0... .7 LED (green)
.0
2 Relay-Output Q+0.0 .1
.2
Q+0.0 to Q+1.7
... ... .3
.4 As soon as an output is
.5
9 Relay-Output Q+0.7 .6 active, the according
.7
LED is turned on
10 L+DC24V SM322
11 2L1 .0
.1
12 Relay-Output Q+1.0 .2
.3
... ... .4
.5
19 Relay-Output Q+1.7 X 2
.6
.7
3 4
11 2L1 Mintern
12
13
14
15
16 = Note: When using inductive load please
17 take an suitable protector!
18
19
20
M
Technical Data