Sunteți pe pagina 1din 2

Une marque de

MTS 220 Tripolaire non radial /


Tripolar no radial field
NF C 33-220

Moyenne Tension (HTA) - Medium Voltage (MV)


6 / 6 (7.2) kV
REACH

Distribution Souterraine - Underground Network

Caractristiques du cble Cable characteristics

+60 - 15 C AG4 AN2 AD6 Bon EN 60332-1 Rigide Sans plomb


Good NF C 32-070 C2 Rigid Lead free

Ces cbles peuvent tre employs pour : la distribution Those cables can be used for : public energy distribution,
dnergie publique, industrielle, en milieu ptrochimique. industrial one and in petrochemical distribution.
Les raccordements de gnratrice, moteurs, clairage,... Generator connectors, engines, lighting, ...

Descriptif du cble Cable design


Ame Conductor
Mtal : cuivre nu Metal : plain copper
Forme : Shape :
S <= 35 mm : ronde S <= 35 mm : circular
S >= 50 mm : sectorale S >= 50 mm : sector-shaped
Souplesse : Flexibility :
Classe 2 cble selon EN 60228 Stranded class 2 according to EN 60228
(IEC 60228) (IEC 60228)
Temprature maximale de lme : Maximum temperature of the conductor :
70C en permanence, 160C en court-circuit 70C in continuous duty,
pendant une dure maximale autorise 160C in short circuit for 5 secondes maximum.
de 5 secondes.
Isolation Insulation
PVC PVC
Assemblage Laying Up
Gaine lastoplastique Elastoplastic sheath
Gaine de ceinture Belting Sheath
PVC PVC
cran mtallique Metallic Shield
Ruban semi conducteur Semiconductor tape
Ruban cuivre nu Plain copper tape
FT N02 MTS 220 TRIPOLAIRE / TRIPOLAR 6/6 - V3 Sept. 2014

Gaine de sparation Separating Sheath


PVC PVC
Armure Armour
2 feuillards acier nu 2 plain steel tapes
Gaine extrieure Outer sheath
PVC rsistant aux hydrocarbures aliphatiques PVC red colour, resistant to aliphatic hydrocarbons
de couleur rouge
Marquage (exemple) Marking (example)
Prysmian nusine - V - 3 x 25 CU - 6/6kV - RH - Prysmian nfactory - V - 3 x 25 CU - 6/6kV - RH -
n de lot - marquage mtrique batch n - metric marking

Prysmian Group Service commercial / Sales department - Tl. : +33 (0)4 72 46 73 99 - mail : infocables.fr@prysmiangroup.com
www.prysmiangroup.com

1/2
Une marque de

Reprage des conducteurs / Cores identification


Nombre
de conducteurs Couleurs Colours
Number of cores
3 Brun - Rouge - Violet Brown - Red - Purple

Conditions de pose Laying conditions

A lair libre En caniveau En terre En buse Avec protection t mini = -5C r mini pos / laid r mini
In free air In duct In ground In conduit With protection = 8D pendant la pose / during laying
= 16 D
Sans protection mcanique complmentaire, Without mecanical protection, those cables can be
ces cbles peuvent tre installs fixs aux parois fixed on the wall, cable trays, cable ladders, other
ou sur des chemins de cbles, des tablettes, autres supports or directly buried.
supports ou directement enterrs.
Caractristiques dimensionnelles Dimensional characteristics
sur gaine
Section sur gaine
de lme sur isolant de ceinture Masse
nominale extrieure
conductor over insulating over belting over outer Mass
Nominal sheath sheath
(approx) (approx) (approx)
cross-section
mm mm (approx) (approx) kg/km
mm
mm mm
3 x 10 3.8 8.9 22.8 30.3 1 470
3 x 16 4.7 9.9 24.9 32.5 1 780
3 x 25 6.0 11.2 28.1 35.6 2 260
3 x 35 6.9 12.1 30.1 39.6 3 080
3 x 50 (sectoral/sector-shaped) / / 31.5 41.2 3 570

Caractristiques lectriques Electrical characteristics


Rsistance Intensit admissible Chute de
Section Courant
maxi 20C Permissible current tension
nominale Capacit capacitif
en c.c.
Capacitance Capacitive Voltage
Nominal Maxi d.c. A lair libre Enterr
approx. current drop
cross-section resistance In free air Buried
F/km approx. cos=0,8
mm at 20C (30C) (20C)
m.A/m V/A/km
/km A A
3 x 10 1,830 0,36 0,69 62 70 3,16
3 x 16 1,150 0,41 0,77 81 94 2,03
3 x 25 0,727 0,46 0,87 105 120 1,32
3 x 35 0,524 0,49 0,93 130 145 0,98
3 x 50 (sectoral/sector-shaped) 0,387 0,56 1,05 165 185 0,75
Conditions de validit Validity terms
FT N02 MTS 220 TRIPOLAIRE / TRIPOLAR 6/6 - V3 Sept. 2014

Intensit maximale pour cble pos seul : Maximal current rating for cable laid alone :
a) lair libre, labri du soleil, sur chemins de cbles ou a) in free air, sheltered from sun, on cable trays or
corbeaux, chelles cbles, et espac de la paroi. brackets, on cable ladders, and spaced from the wall.
b) enterr dans un sol de rsistivit thermique de 1 b) buried with thermal resistivity of the ground 1 K.m/W,
K.m/W, profondeur de pose : 800 mm. laying depth : 800 mm.
Les valeurs dintensit admissible et de chute de tension Permissible current rating values and voltage drops noticed
mentionnes dans les tableaux sont celles dune liaison in boards are according to a THREE PHASE CURRENT.
TRIPHASEE. If conditions are differents, apply correction factors from
Si les conditions sont diffrentes, appliquer les facteurs de NF C 13-200 standard.
correction de la norme NF C 13-200.
PRYSMIAN 2014. Tous droits rservs. Il est interdit de copier, photocopier ou reproduire les informations contenues dans ce document dans quelque forme que ce soit, mme en partie sans laccord crit pralable
de Prysmian. Les informations sont communiques titre indicatif, Prysmian se rservant le droit de modifier les caractristiques du produit sans pravis.
PRYSMIAN 2014. All Rights Reserved. The information contained within this document must not be copied, reprinted or reproduced in any form, either wholly or in part, without the written consent of Prysmian.
The information is believed correct at the time of issue. Prysmian reserves the right to amend this specification without notice. This specification is not contractually valid unless specifically authorised by Prysmian.

Prysmian Group Service commercial / Sales department - Tl. : +33 (0)4 72 46 73 99 - mail : infocables.fr@prysmiangroup.com