CAPACITIES CHART
In keeping with our policy of continuing product improvement, 2222 Camden Court This specification describes an Elkay product with design, quality and
Elkay reserves the right to change specification without notice. Oak Brook, IL 60523 functional benefits to the user. When making a comparison of other
Please visit elkay.com for the most current version. 630-572-3192 producers offerings, be certain these features are not overlooked.
elkay.com 2016 Elkay
SPEC00259 (03/2016)
EZH2O Bottle Filler Station
with Filtered Single LZ Cooler
Models Enhanced LZS8WSLP & LZS8WSSP
LZSDWSSP & LZSDWSLP ROUGH-IN DIMENSIONS
RATED FOR INDOOR USE ONLY
IMPORTANT! INSTALLER PLEASE NOTE: NOTICE
These units are designed and built to provide water to the user which has not This water cooler must be connected to the water supply using a dielectric
been altered by materials in the cooler waterway. The grounding of electrical coupling. The cooler is furnished with a non-metallic strainer which meets this
equipment such as telephone, computers, etc. to water lines is a common requirement. The drain trap which is provided by the installer should also be
procedure. This grounding may be in the building but may also occur away from plastic to completely isolate the cooler from the building plumbing system.
the building. This grounding can cause electrical feedback into a water cooler
creating an electrolysis which results in a metallic taste or an increase in the
metal content of the water. This condition is avoidable by installing the cooler
using the proper materials as shown.
Model Shown with Flexi-Guard Safety Bubbler Bottle Filler unit will mount on bracket attached to wall by 6 holes (as shown).
Water and electrical will connect through pre-punched hole in basin.
18"
458mm
7" 7"
178mm 178mm
C
L
3 1/2"
90mm
ACTIVATION 6 3/8" 6 3/8"
162mm 162mm
51 9/16" SENSOR
1310mm 19"
15" 483mm
381mm 19"
482mm
2 7/8"
73mm
38 1/2"
979mm 2" 2"
51mm 51mm
B
E E 32 7/8"
835mm 2"
FILTER 8 1/16" 51mm
ORIFICE
HEIGHT 205mm
A
D
28 13/16"
731mm
31 5/16"
28 13/16" 796mm C
731mm RIM 3"
21 7/8" 76mm
HEIGHT
556mm
WATER
FILTER
27"
19" 686mm
483mm 2" ADA 5 7/8"
51mm REQUIREMENT 149mm
F
3 7/8"
98mm 13 15/16"
17 7/16" 354mm 12 1/2"
443mm 5 3/4" 318mm
146mm
7" 7"
178mm 178mm
FINISHED FLOOR
LEGEND:
A = Recommended Water Supply location. Shut-off Valve (not furnished) to accept
3/8 O.D. unplated copper tube. Up to 3 (76mm) maximum out from wall. Job Name: ____________________________________
B = Recommended Waste Outlet location. To accommodate 1-1/4 nominal drain. Model: _______________________ Qty. ____________
Drain stub 2 (51mm) out from wall. Contact: ______________________________________
C = 1-1/4 Trap (not furnished).
D = Electrical Supply (3) Wire Recessed Box Duplex Outlet. Approval Signature: _____________________________
E = Insure proper ventilation by maintaining 6 (152mm) minimum clearance from cabinet Notes:
louvers to wall.
F = 7/16 (11mm) Bolt Holes for fastening to wall.
NOTE: Installations Must Use Ground Fault Circuit Interrupter (GFCI).