Sunteți pe pagina 1din 4

Siemens AG .

Power Generation (KWU) The reproduction, transmission or use of this document or its
contents is not permitted without express written authority. Offenders
will be liable for damages. All rights, including rights created by
patent grant or registration of a utility model or design, are reserved.

H30-K5014 Anweisung/Richtlinie, engl. KWU 04.99 D97 /conversion/tmp/scratch/368577248.doc


Design Request for GuD Plants and Steam No.: 014
Power Plants Index: d
Steamline Drain Pot design Page: 2

Design Request for No.: 014


GuD Plants and Steam Power Index
Plants Issued by: E951
Effective as of: 2005-11-10
Title: Feedwater Suctionline Pipe Routing Requirements

SG No.: Pages: 4 Appendices:


Handling Instructions:
FOR SIEMENS INTERNAL USE ONLY

1) Arrangement for Suction Strainer

1.1) Standard Solution

The suction strainer can connected direct to the pump suction nozzle, in case the pipe
dimension of the strainer and the suction nozzle are identical.

In case the pipe dimensions of the strainer and the suction nozzle are dissimilar, the
reducer can connected between suction nozzle and strainer.

1.2) Straight pipe length requirement upstream the suction strainer

Released: Telgmann E951 2005-11-10


Released:
Reviewed: Krbs E9513 2005-11-10
Prepared by: Rhrseitz E9512 2005-11-10
Name Org. Unit Signature Date

Also reviewed by:

Siemens AG . Power Generation (KWU) The reproduction, transmission or use of this document or its
contents is not permitted without express written authority. Offenders
will be liable for damages. All rights, including rights created by
patent grant or registration of a utility model or design, are reserved.

H30-K5014 Anweisung/Richtlinie, engl. KWU 06.98 D /conversion/tmp/scratch/368577248.doc


Design Request for GuD Plants and Steam No.: 014
Power Plants Index: d
Steamline Drain Pot design Page: 3

1.3) Straight pipe length requirement in the suction line

For a combination of elbows in the suction line with more than 2 elbows in the line
within a short distance, an approval is required by the pump department/ pump
supplier.

Siemens AG . Power Generation (KWU) The reproduction, transmission or use of this document or its
contents is not permitted without express written authority. Offenders
will be liable for damages. All rights, including rights created by
patent grant or registration of a utility model or design, are reserved.

H30-K5014 Anweisung/Richtlinie, engl. KWU 06.98 D /conversion/tmp/scratch/368577248.doc


Design Request for GuD Plants and Steam No.: 014
Power Plants Index: d
Steamline Drain Pot design Page: 4

2. Reducer in the suction line

A reducer in the suction line is only allowed at the start point of the line or at the pump
suction nozzle. A reducer within the routing of the pipe is not allowed.

3. General remark

These requirements are mandatory for all types of strainers.

Siemens AG . Power Generation (KWU) The reproduction, transmission or use of this document or its
contents is not permitted without express written authority. Offenders
will be liable for damages. All rights, including rights created by
patent grant or registration of a utility model or design, are reserved.

H30-K5014 Anweisung/Richtlinie, engl. KWU 06.98 D /conversion/tmp/scratch/368577248.doc