System Analyzer

INSTALLATION INSTRUCTIONS

- Local administrative privileges are required.

- When updating the network version run the install from the TRACE Family CD. This will

automatically remove the old version of System Analyzer. All client machines will

need to run the net client setup to be updated.

1. Close System Analyzer.

2. Insert TRACE Family CD into CD-Rom drive and run autorun.exe if it does not automatically start.

For assistance, please contact the C.D.S. Support Center

at 608-787-3926 or CDSHELP@trane.com

_________________________________________________________________________________

[Version 6.1.0] 12/10/08

This update contains the following items:

-Updated program installation and upgrade to Microsoft .Net 2.0 version

-Added new helical rotary equipment

-Updated EPA environmental information

-Updated Base Utility units

-Changed default schedule for WSHP to "Satisfy Load"

[Version 6.0.3, SAup603.exe] 05/05/08


This update contains the following items:

-Added EER units for equipment energy rate

-Added plant level thermal storage

-Added ability to assign secondary coil to different utility

-Added pump list to library reports

-Added field for entering a description fro Alt 1 during file creation

-Added "Base Alternative= X" text in Economic Comparison Report

-Added Fan Cycling schedule for heating only systems

-Removed infiltration in building interior zone

-Changed Occupied "Based On" default in building schedules to 100%

-Changed default static pressure for primary fan in WSHP and VRV systems from 3 to 0.5 in.wg.

-Changed environmental information for international locations to "No data available"

-Changed system type "Parallel Fan Powered" to "Parallel Fan Powered w/ Heating Coil on mixing box
outlet"

-Fixed error in metric conversion for U-values

-Fixed error in metric import value for l/s/person

-Fixed error in metric conversion of cooling load in cooling controls/details screen

-Fixed recurring cost issue with Depreciation Life Taxes

-Fixed issue of some equipment schedules not being recognized when importing into Trace

-Fixed Heat Recovery rejecting heat assignments

-Fixed web links from program

[Version 6.0.2, SAup602.exe] 04/04/07

This update contains the following items:

-Fixed custom equipment curve issues (some were not being created)

-Fixed equipment schedule generation when primary was Normal and secondary season was not

-Fixed Misc Loads reported incorrectly when energy meter was assigned as Purchased Steam.

-Fixed System 1 and 2 switching of information on reports


-Fixed Customer Charge in Utility Rates to be applied according to season definitions

-Fixed blank economic reports

-Added units for water utility rates

-Fixed two conversion errors for metric units

-Fixed "calculation Failed" error when using a Strip Mall building type

For the import process of version 5 files

-Fixed issue where weather locations with a space in the name

-Fixed import of buildings with "Brick Veneer" as a wall type

[Version 6.0.1, SAup601.exe] 01/17/07 (internal release)