Sunteți pe pagina 1din 19

DBS3900 Acceptance Manual (Extended Part)

DBS3900 Extended Part

T1 OM Function

T1.1 System Login

T1.1.1 System Login


Objective
Verify that users can log in to the BSC6000 LMT and perform operations.
Network diagram No.
None.
Prerequisites
The BTS system is running properly.
The BSC6000 is running properly.
You have obtained the user name and password for login.
Procedure Expected Result
1. Start the BSC6000 LMT. The user logs in to the BSC6000 LMT
successfully and can perform the management
2. Enter the user name and password. and maintenance operations related to the BTS.
3. Enter the IP address of the BSC6000.
4. Set User Type to Local User. Click OK..
Remarks
None.

T1.2 System Exit

T1.2.1 System Exit


Objective
DBS3900 Acceptance Manual (Extended Part)

Verify that users can exit the BSC6000 LMT normally.


Network diagram No.
None.
Prerequisites
1. The BTS system is running properly.
2. The BSC6000 is running properly.
Procedure Expected Result
On the BSC6000 LMT, choose System > Exit. The user exits the BSC6000 LMT normally.
Remarks
None

T1.3 Software Loading and Activation

T1.3.1 Board Software Loading


Objective
Verify that the board software loading can be performed on the BSC6000 LMT.
Network diagram No.
None.
Prerequisites
1. The BTS system is running properly.
2. The BSC6000 is running properly.
3. The index of the board software to be loaded is created on the BSC6000 LMT, and the
software is uploaded to the BSC6000.
Procedure Expected Result
1. Download the GTMU software. The progress bar displays the loading progress.
The software loading is complete when the
1. On the BSC6000 LMT, choose BTS progress bar displays 100%.
Maintenance > Load BTS
Software. The dialog box for
software loading is displayed.
2. In the Site Type area, select the
target site type. Then, select
GTMU_MAIN in Software Type.
Select the index of the software to
be loaded. Click Next. Double-click
DBS3900 Acceptance Manual (Extended Part)

the site name in the displayed dialog


box.
3. Click Next to load the software.
2. Download the GRFU software. The progress bar displays the loading progress.
The software loading is complete when the
1. On the BSC6000 LMT, choose BTS progress bar displays 100%.
Maintenance > Load BTS Software. The
dialog box for software loading is displayed.
2. In the Site Type area, select the site type.
Then, select GRFU_MAIN in Software
Type. Select the index of the software to be
loaded. Click Next. Double-click the site
name in the displayed dialog box.
3. Click Next to load the software.
Remarks
1. In the case of the DBS3900/DBS3900A, the required board software are
GTMU_MAIN, GRFU_MAIN, and DRFU-MAIN.
2. Before software loading, ensure that the version associated with the board software
index is correct.
3. Activate the GTMU software before you activate the software of other boards.
4. The procedure for DRFU software loading is the same as that for GRFU software
loading. This section takes the GRFU as an example

T1.3.2 Board Software Activation


Objective
Verify that the board software activation can be performed on the BSC6000 LMT.
Network diagram No.
None.
Prerequisites
1. The BTS system is running properly.
2. The BSC6000 is running properly.
3. The software loading is complete.
Procedure Expected Result
1. Activate the GTMU software. 1. After the software is activated, the board is
reset automatically.
On the BSC6000 LMT, choose BTS
Maintenance > Activate BTS Software. The 2. When you query the GTMU information, the
dialog box for software activation is result shows that the clock state is Locked.
displayed.
DBS3900 Acceptance Manual (Extended Part)

In the Site Type area, select the site type.


Then, select GTMU_MAIN in Software Type.
Select the index of the software version to be
activated. Click Next. Double-click the site
name in the displayed dialog box.
Click Next to activate the software.
2. Activate the GRFU software. After the software is activated, the board is reset
automatically.
On the BSC6000 LMT, choose BTS
Maintenance > Active BTS Software.
The dialog box for software activation is
displayed.
In the Site Type area, select the site
type. Then, select GRFU_MAIN in
Software Type. Select the index of the
software version to be activated. Click
Next. Double-click the site name in the
displayed dialog box.
Click Next. Specify the target GRFU in
Boards to be activated. Click Next to
perform the software activation.
Remarks
When you activate the GTMU software, do not need to enter the board number.
The format of board number may be 1,2,3...x, or 1-x. If no board number is entered, all
the boards of the same type are loaded by default.
The board is reset after the software is activated. In this case, ignore the board reset
alarm.
When the activation starts, the software activation progress bar is displayed to indicate
the activation progress.
Activate the GTMU software before you activate the software of other modules.
The procedure for DRFU software activating is the same as that for GRFU software loading.
This section takes the GRFU as an example

T1.4 Resources Check Function

T1.4.1 Resources Check


Objective
Verify that the resources check function is normal on the BSC6000 LMT.
Network diagram No.
None.
DBS3900 Acceptance Manual (Extended Part)

Prerequisites
1. The BTS system is running properly.
2. The BSC6000 is running properly.
Procedure Expected Result
1 On the BSC6000 LMT, choose BTS The queried state of the resources is updated in
Maintenance > Maintenance Site > real time in the Monitor BTS Resource dialog
Monitor BTS Resource. box.
2 In the displayed Monitor BTS Resource
dialog box, select the site for acceptance
and set the resource type.
Remarks
The query result indicates the resources utilization of each board configured.

T1.5 Equipment Management

T1.5.1 Site Reset in Levels


Objective
Verify that the BTS can be reset in levels on the BSC6000 LMT.
Network diagram No.
None.
Prerequisites
1. The BTS system is running properly.
2. The BSC6000 is running properly.
Procedure Expected Result
1) On the BSC6000 LMT, right-click the site 1) The Reset BTS in Levels dialog box is
name for acceptance in Management Tree, displayed.
and then choose Reset BTS in Levels from
the shortcut menu. 2) After a moment, the system displays a
message indicating the successful reset.
2) Select Level 3, and then click Reset.
3) The Reset BTS in Levels dialog box is
3) On the BSC6000 LMT, right-click the site displayed.
name for acceptance in Management Tree,
and then choose Reset BTS in Levels from 4) After a moment, the system displays a
the shortcut menu. message indicating the successful reset.

4) Select Level 4, and then click Reset.


Remarks
During initialization after reset, you cannot perform any operations on the BTS.
DBS3900 Acceptance Manual (Extended Part)

The level 3 BTS reset loads the configuration data instead of program during initialization.

T1.5.2 Cell Administrative State Change


Objective
Verify that the administrative state of a certain cell can be changed on the BSC6000 BSC6000 LMT.
Network diagram No.
None.
Prerequisites
1. The BTS system is running properly.
2. The BSC6000 is running properly.
Procedure Expected Result
1. Lock the cell. The displayed color of each GRFU is apple
green, and the board information is locked
1. Right-click the name of the cell to be locked. (manual).
2. Choose Modify Administrative State from
the shortcut menu.
3. In the Operation Status area, set Modified
Status to Locked.
4. Check the color of each GRFU in the cell on
the BSC6000 LMT. Check the board
information.
2. Unlock the cell. The displayed color of each GRFU is apple
green, and the board information is working.
1. Right-click the name of the cell to be
unlocked.
2. Choose Modify Administrative State from
the shortcut menu.
3. In the Operation Status area, set Modified
Status to Unlocked.
4. Check the color of each GRFU in the cell on
the BSC6000 LMT. Check the board
information.
Remarks
If the administrative state of a cell is modified to Locked, the calls in the cell are
affected.
The calls made by the MSs in the cell cannot be set up successfully until the
administrative state of the cell is modified to Unlocked.
DBS3900 Acceptance Manual (Extended Part)

T1.6 TRX Management

T1.6.1 TRX Administrative State Change


Objective
Verify that the administrative state of a certain TRX in a cell can be changed on the BSC6000 LMT.
Network diagram No.
None.
Prerequisites
1. The BTS system is running properly.
2. The BSC6000 is running properly.
Procedure Expected Result
1. Lock the TRX. 1. The shortcut menu is displayed.
(1) Right-click the TRX to be locked. 2. The Modify Administrative State dialog box
is displayed.
(2) Choose Modify Administrative State
from the shortcut menu. 3. The administrative state of the locked TRX is
LOCKED.
(3) In the Operation Status area, set
Modified Status to Locked. 4. The displayed color of each GRFU is green,
and the TRX information is locked (manual).
(4) Check the color of each GRFU
corresponding to the baseband, and
query the board information.
2. Unlock the TRX. a) The shortcut menu is displayed.
1. Right-click the TRX to be unlocked. b) The Modify Administrative State
dialog box is displayed.
2. Choose Modify Administrative State from
the shortcut menu. c) The administrative state of the unlocked
TRX is UNLOCKED.
3. In the Operation Status area, set Modified
Status to Unlocked. d) The displayed color of each GRFU is
green, and the TRX information is
4. Observe the color of each GRFU Available.
corresponding to the baseband, and query
the board information.
Remarks
1. If the administrative state of the baseband is modified to Locked, the calls on the baseband are
affected.
2. The calls made by the MSs on the baseband cannot be set up successfully until the administrative
state of the baseband is modified to Unlocked.
DBS3900 Acceptance Manual (Extended Part)

T1.6.2 TRX Loopback Test


Objective
Verify that the TRX loopback test can be performed on the BSC6000 LMT.
Network diagram No.
None.
Prerequisites
1. The BTS system is running properly.
2. The BSC6000 is running properly.
3. The GRFU to be tested is running properly.
Procedure Expected Result
(1) On the BSC6000 LMT, right-click the 1. The Test TRX Loopback dialog box is
TRX, and then choose Test TRX displayed.
Loopback from the shortcut menu.
2. After the BIU loop test is complete, the bit
(2) In the displayed dialog box, set Type to error rate (BER) reported by the system is
BIU Loop Test in the Setting area, and 0.
specify the duration of the test. Click
Start.
Remarks
If the TRX is faulty, the test result prompts that the TRX is faulty.

T1.6.3 Channel Status Check


Objective
Verify that the channel check can be performed on the BSC6000 LMT.
Network diagram No.
None.
Prerequisites
1. The BTS system is running properly.
2. The BSC6000 is running properly.
3. The GRFU to be tested is running properly.
Procedure Expected Result
(1) On the BSC6000 LMT, right-click the (1) The Monitor Channel Status dialog box
TRX, and then choose Monitor Channel is displayed, showing the type and status
status from the shortcut menu. of each channel.
(2) Make a call on the TRX, and check the (2) The idle channel is white, and the used
Monitor Channel Status dialog box at channel is green.
DBS3900 Acceptance Manual (Extended Part)

the same time.


Remarks
None.

T1.6.4 TRX Reset


Objective
Verify that the TRX reset can be performed on the BSC6000 LMT.
Network diagram No.
None.
Prerequisites
1. The BTS system is running properly.
2. The BSC6000 is running properly.
3. The GRFU to be tested is running properly.
Procedure Expected Result
1. On the BSC6000 LMT, right-click the TRX, (1) The shortcut menu is displayed.
and then choose Reset TRX from the
shortcut menu. (2) A dialog box is displayed indicating the
successful TRX reset.
2. Click Reset to reset the TRX.
Remarks
The TRX reset disrupts the calls on the TRX. After the reset is complete, the TRX can be used
normally.

T1.7 Channel Management

T1.7.1 Channel Administrative State Change


Objective
Verify that the administrative state of a certain channel in the cell can be changed on the BSC6000
LMT.
Network diagram No.
None.
Prerequisites
1. The BTS system is running properly.
DBS3900 Acceptance Manual (Extended Part)

2. The BSC6000 is running properly.


3. The GRFU to be tested is running properly.
Procedure Expected Result
1. Lock the channel. 1. The Modify Administrative State dialog box
is displayed.
(1) Right-click the TRX of which the channel
is to be locked. 2. The operation result shows a message
indicating Succeeded in modifying the
(2) Choose Modify Administrative State administrative state.
from the shortcut menu.
3. The channel administrative state is
(3) In the Modify Administrative State LOCKED.
dialog box, set Object to Channel in
Operation Object. Then, specify the
channel number to be locked in Channel.
(4) In the Operation Status area, set
Modified Status to Locked.
2. Unlock the channel. 1. The Modify Administrative State dialog box
is displayed.
1. Right-click the TRX of which the channel is
to be unlocked. 2. The operation result shows a message
indicating Succeeded in modifying the
2. Choose Modify Administrative State from administrative state.
the shortcut menu.
3. The channel administrative state is
3. In the Modify Administrative State dialog UNLOCKED.
box, set Object to Channel in Operation
Object. Then, specify the channel number to
be unlocked in Channel.
4. In the Operation Status area, set Modified
Status to Unlocked.
Remarks
1. If the administrative state of the channel is modified to LOCKED, the calls in the channel are
affected.
2. The calls made by the MSs in the channel cannot be set up successfully until the administrative
state of the channel is modified to UNLOCKED.

T1.7.2 Channel Loopback Test


Objective
Verify that the channel loopback test can be performed on the BSC6000 LMT.
Network diagram No.
None.
Prerequisites
DBS3900 Acceptance Manual (Extended Part)

1. The BTS system is running properly.


2. The BSC6000 is running properly.
Procedure Expected Result
(1) On the BSC6000 LMT, right-click the 1. The Test Channel Loopback dialog box is
TRX, and then click Test Channel displayed.
Loopback from the shortcut menu.
2. After the BIU loop test is complete, the BER
(2) In the Setting area of the displayed reported by the system is 0.
dialog box, set Type to BIU Loop Test,
and specify the duration. Click Start.

T1.8 Board Management

T1.8.1 Board Operation


Objective
Verify that the board-related operations can be performed on the BSC6000 LMT.
Network diagram No.
None.
Prerequisites
1. The BTS system is running properly.
2. The BSC6000 is running properly.
3. The GRFU to be tested is running properly.
Procedure Expected Result
1. Reset a board. 1. The shortcut menu is displayed.
1. Choose BTS Maintenance > Maintain 2. The Reset Board dialog box is displayed.
Board.
3. The configuration is successful.
2. Choose Reset Board.
4. A message is displayed, indicating that the
3. Specify the parameters Site, Subrack, and reset is successful.
Slot.
4. Click Reset.
2. Query the information of a board. 1. The shortcut menu is displayed.
(1) Choose BTS Maintenance > Maintain 2. The Query Board Information dialog box is
Board. displayed.
(2) Choose Query Board Information. 3. The configuration is successful.
(3) Specify the parameters Site, Subrack,
DBS3900 Acceptance Manual (Extended Part)

and Slot. 4. A message is displayed, indicating the


successful query.
(4) Click Query.
Remarks

T1.8.2 Clock Setting


Objective
Verify that the clock setting can be performed on the BSC6000 LMT
Network diagram No.
None.
Prerequisites
(1) The BTS system is running properly.
(2) The BSC6000 is running properly.
Procedure Expected Result
1. Choose BTS Maintenance > Maintain The displayed parameters related to the clock
Board > Maintain Clock. include Clock Mode and Trace Mode.
2. Specify the parameters Site, Subrack, and
Slot.
3. Click Query.
Remarks

T2 Services

T2.1 Calling Service on the TRX

T2.1.1 Calling Service on the TRX


Objective
Verify that suBSC6000ribers can make calls in each TCH of each TRX in the system.
Network diagram No.
None.
Prerequisites
DBS3900 Acceptance Manual (Extended Part)

1. The BTS system is running properly.


2. Two test MSs (with valid SIM cards) are ready for use. The MSs are powered on and registered
with the network.
Procedure Expected Result
Perform the MS-to-MS call in each TCH of the The call in each TCH is successful. The voice
cell. quality is satisfactory.
Remarks
To make a call in a specified TCH, you must lock the other TCHs on the SMT.

T2.2 Fault Recovery

T2.2.1 Trunk Recovery


Objective
Verify that the links can be restored after the trunk fault is cleared in the BTS.
Network diagram No.
None.
Prerequisites
1. The BTS system is running properly.
2. The communication between the SMT and BTS is normal.
Procedure Expected Result
1. Disconnect the E1 cable to disrupt the trunk On the SMT, the E1 remote alarm and LAPD link
transmission (each board in normal state). alarm are reported.
2. Connect the E1 cable to restore the trunk The alarms are cleared. The link is set up again.
transmission (each board in normal state).
Remarks
None.

T2.2.2 Power-Off Recovery


Objective
Verify that the BTS can work normally after it is powered off and then powered on.
Network diagram No.
None.
Prerequisites
DBS3900 Acceptance Manual (Extended Part)

1. The BTS system is running properly.


2. The communication between the SMT and BTS is normal.
Procedure Expected Result
(1) Power off the BTS. All the boards in the BTS are powered off.
(2) Power on the BTS. After the BTS is powered on, all the boards work
normally after initialization. The board LEDs
indicate that the boards work normally.
Remarks
For more information about board LEDs, see the DBS3900/DBS3900A Product Description.

T2.2.3 BCCH TRX Mutual-Aid Function


Objective
Verify that the BTS supports the BCCH TRX mutual-aid function.
Network diagram No.
None.
Prerequisites
(1) On the BSC6000 BSC6000 LMT, the TRX Aiding Function Control in Call Control is set to
Allowed & Recover Immediately.
(2) Multiple TRXs are configured in at least one cell under the BTS.
(3) The BTS works normally. The BCCH TRX works normally.
(4) Two test MSs (with valid SIM cards) are ready for use.
Procedure Expected Result
(1) On the SMT, block the BT of the BCCH 1. The status of all channels under the BT of
TRX in the multi-TRX cell. the BCCH TRX is O.
(2) After 15 minutes, start the SMT or 2. The BCCH is switched to another BT through
BSC6000 LMT. Select the BT, and open the mutual-aid function.
the Monitor Channel Status dialog box.
Check the switchover of the BCCH TRX. 3. The call is successful, and the voice quality
is satisfactory.
(3) After the channel status of the new
BCCH TRX changes to I, perform the
MS-to-MS call.
Remarks
1. During the initialization, enable the TRX mutual-aid function.
2. This function can be used after 15 minutes later than the initialization.
DBS3900 Acceptance Manual (Extended Part)

T2.2.4 BCCH TRX Mutual-Aid Recovery


Objective
Verify that the system can work normally after the BCCH TRX mutual-aid recovery.
Network diagram No.
None.
Prerequisites
1. On the BSC6000 BSC6000 LMT, the TRX Aiding Function Control in Call Control is set to
Allowed & Recover Immediately.
2. Multiple TRXs are configured in at least one cell under the BTS.
3. The BTS works normally, and the BCCH TRX mutual aiding is performed.
4. The BCCH TRX fault before the mutual aiding is cleared.
5. Two test MSs (with valid SIM cards) are ready for use.
Procedure Expected Result
(1) Open the SMT or BSC6000 LMT, and 1. The data of the original BCCH TRX is
choose the BT (Baseband of the BCCH). restored.
After 15 minutes, open the Monitor
Channel Status dialog box. Check the 2. The call is successful, and the voice quality
switchover of the BCCH TRX. is satisfactory.

(2) After the channel status of the BCCH


TRX changes to I, power on the MSs and
make a call.
Remarks
The BCCH TRX mutual-aid recovery takes some time. You must make the call after the channel
status of the BCCH TRX changes to I.

T3 RF Specifications

T3.1 RF Specifications

T3.1.1 Antenna VSWR


Objective
Verify that the antenna VSWR complies with the corresponding engineering specifications.
Network diagram No.
None.
DBS3900 Acceptance Manual (Extended Part)

Prerequisites
(1) The BTS system works normally.
(2) The antenna test device is available.
Procedure Expected Result
(1) Power off all the GRFUs in the test cell. (1) The connection between the feeder and
Disconnect the feeder from the BTS and the device is proper.
connect the feeder to the antenna test
device. (2) The VSWR is less than or equal to 1.5. In
the case of a swapped site, the new
(2) Record the measured VSWR into VSWR is less than or equal to the original
Attached Table 1 of Part 4 Acceptance VSWR.
Result.
(3) The test result is the same as that in step
(3) Measure the VSWRs of all the 2.
components in the antenna system by
using the preceding method. Restore the
original connections after the test.
Remarks
None.

T3.1.2 Transmit Power of the TRX


Objective
Verify that the actual transmit power of each TRX complies with the corresponding engineering
specifications.
Network diagram No.
None
Prerequisites
1. The BTS works normally. The calls on each TRX are normal.
2. One power meter and two test MSs are available.
Procedure Expected Result
1. Connect the power meter to the output port (1) The connection between the output port
on the BCCH TRX for test. Check the on the BCCH TRX and the power meter
connections. is proper.
2. Connect the power supply to the power (2) The symbol AV is displayed on the
meter and switch on the power meter. screen of the power meter.
Enable the power meter to measure the
average burst power. (3) The locking operation is successful.

3. On the SMT, lock the TCHs on the other (4) The measured power value is equal to
TRXs. the preset transmit power of the TRX for
test.
4. Record the measured power into Attached
DBS3900 Acceptance Manual (Extended Part)

Table 2 in the Internal Remarks and


Selection Table of Acceptance Items.
Remarks
To set the power meter of NRT-Z44, perform the following steps:
1. Press CONF to enter the ENV KEY interface.
2. Press > and select AV.BURST (underlined). Press SEL to enter the AV.BURST interface.
3. Press > and select AUTO. Press SEL to enter the VID.BW interface.
4. Press > and select 200KHz. Press SEL to return to the measurement interface. The displayed
symbol AV indicates that the current measurement is average burst power.

T4 Abis Interface Transmission

T4.1 IP BTS Call

T4.1.1 IP BTS Call


Objective
Verify that calls can be processed on each TCH of each TRX of the IP BTS.
Network diagram No.
None.
Prerequisites
1) The BTS system is running properly.
2) Two test MSs (with valid SIM cards) are ready for use.
Procedure Expected Result
Use the MSs to perform call tests on each Calls are successfully processed on all the TCHs, and
TCH of the cell. the voice quality is good.

Remarks
To ensure that a call is processed by a specific TCH, you must block all the other TCHs on the basic
maintenance console.

T4.2 IPCLK

T4.2.1 Clock Link Establishment


Objective
Verify that the BTS can successfully establish a clock link with the IPCLK server.
DBS3900 Acceptance Manual (Extended Part)

Network diagram No.


None.
Prerequisites
The BTS is running properly, the IPCLK server is running properly, and the clock status is Locked.
Procedure Expected Result
1. Check whether the 1. On the maintenance console of the IPCLK server, the traffic IP
route between the BTS address of the BTS can be successfully pinged.
and the IPCLK is
functional. 2. When the status of the BBU is queried, the result is that the clock
mode is the IP clock and the clock status changes to pull-in, which
2. On the LMT, configure means that the link between the BTS and the IPCLK server is
the IP address of the successfully established and the BTS is in the state of receiving
IPCLK server, port of clock packets.
the IPCLK server, and
the IP clock mode used
by the BTS.
Remarks
None.

T4.2.2 Clock Locking in Continuous Synchronization Mode of the IP Clock


Objective
Verify clock locking when the IP clock uses the continuous synchronization mode.
Network diagram No.
None.
Prerequisites
The connection between the BTS and the IPCLK server is successfully established, and the status of
the IPCLK server is Locked.
Procedure Expected Result
1. Configure the synchronization mode of 1. The configuration is successful.
the IP clock to the continuous
synchronization mode. 2. When the information of the GTMU is queried, the
result shows that the clock status is pull-in.
2. Configure the clock mode of the BTS to
the IP clock. 3. When the information of the GTMU is queried, the
result shows that the clock status is Locked.
3. Wait two hours.
Remarks
None.
DBS3900 Acceptance Manual (Extended Part)

T4.2.3 Clock Locking in Intermittent Synchronization Mode of the IP Clock


Objective
Verify clock locking when the IP clock uses the intermittent synchronization mode.
Network diagram No.
None.
Prerequisites
The connection between the BTS and the IPCLK server is successfully established, and the status of
the IPCLK server is Locked.
Procedure Expected Result
1. Configure the synchronization mode of 1. The configuration is successful.
the IP clock to the intermittent
synchronization mode, with the 2. When the information of the GTMU is queried, the
intermittent synchronization cycle set to result shows that the clock status is pull-in.
1, and synchronization initiation time 3. When the information of the GTMU is queried, the
set to 00:00 (configurable). result shows that the clock status is Reserved.
2. Configure the clock mode of the BTS to
the IP clock.
3. Wait two hours.
Remarks
In intermittent synchronization mode, the synchronization mode and synchronization initiation time are
configurable.