Sunteți pe pagina 1din 32

ZXSDR B8200 Product Description

GUL Multi-Mode
ZXSDR B8200 Product Description

ZXSDR B8200 Product Description

2016 ZTE Corporation. All rights reserved.


ZTE CONFIDENTIAL: This document contains proprietary information of ZTE and is not to be disclosed or used
without the prior written permission of ZTE.
Due to update and improvement of ZTE products and technologies, information in this document is subjected to
change without notice.

ZTE Confidential & Proprietary 1


ZXSDR B8200 Product Description

TABLE OF CONTENTS

1 Overview ............................................................................................................ 5
1.1 Introduction .......................................................................................................... 5
1.2 Benefits................................................................................................................ 5
1.3 Application Scenarios .......................................................................................... 6

2 Product Architecture ......................................................................................... 8


2.1 Physical Structure ................................................................................................ 8
2.2 Hardware Structure .............................................................................................. 9
2.2.1 Control & Clock Board (CC16B) ........................................................................... 9
2.2.2 Baseband Processing Board .............................................................................. 11
2.2.3 Fabric Switch Board (FS5) ................................................................................. 14
2.2.4 Site Alarm Board (SA3) ...................................................................................... 15
2.2.5 Power Module (PM3) ......................................................................................... 16
2.2.6 Fan Array Module (FAM) .................................................................................... 17
2.3 Software Architecture ......................................................................................... 18
2.4 Functionality....................................................................................................... 19

3 Technical Specifications ................................................................................. 21


3.1 Physical Indices ................................................................................................. 21
3.2 Capacity Indices ................................................................................................ 21
3.3 Power Indices .................................................................................................... 22
3.3.1 Power Supply..................................................................................................... 22
3.3.2 Power Consumption........................................................................................... 22
3.4 Interface Indices ................................................................................................ 22
3.5 Environment Indices .......................................................................................... 23
3.6 Electromagnetic Compatibility Indices ................................................................ 24
3.7 Reliability Indices ............................................................................................... 24

4 Configurations Principles ............................................................................... 25

5 Site Support Cabinets for B8200 .................................................................... 26


5.1 BC8910A ........................................................................................................... 26
5.2 ZXSDR BS8906 ................................................................................................. 27
5.3 Physical Indices ................................................................................................. 28

6 Glossary ........................................................................................................... 29

2 ZTE Confidential & Proprietary


ZXSDR B8200 Product Description

FIGURES

Figure 1-1 B8200 in the GSM/UMTS/LTE Network ............................................................. 5


Figure 1-2 B8200 Application Scenario ............................................................................... 7
Figure 2-1 Baseband Unit -- ZXSDR B8200 ........................................................................ 8
Figure 2-2 B8200 Hardware Structure ................................................................................ 9
Figure 2-3 CC16B Panel ..................................................................................................... 9
Figure 2-4 UBPG3 Panel ...................................................................................................12
Figure 2-5 BPN2 Panel ......................................................................................................13
Figure 2-6 FS5 Panel .........................................................................................................14
Figure 2-7 SA3 Panel.........................................................................................................15
Figure 2-8 PM3 Panel ........................................................................................................16
Figure 2-9 FAM Panel ........................................................................................................17
Figure 2-10 B8200 Software Structure ...............................................................................18
Figure 5-1 Physical Structure of BC8910A (AC Power Supply) ..........................................26
Figure 5-2 Physical Structure of BC8910A (DC Power Supply) ..........................................27
Figure 5-3 Physical Structure of ZXSDR BS8906 Standalone Cabinet ..............................27

TABLES

Table 2-1 Board List of ZXSDR B8200................................................................................ 8


Table 2-2 Key Indices of CC16B ........................................................................................10
Table 2-3 CC16B Panel Interfaces.....................................................................................10
Table 2-4 Key Indices of BPN2 ..........................................................................................13
Table 2-5 BPN2 Panel interfaces .......................................................................................14
Table 2-6 Key Indices of FS boards ...................................................................................14
Table 2-7 FS Panel Interfaces ...........................................................................................14
Table 2-8 SA Panel Interfaces ...........................................................................................15

ZTE Confidential & Proprietary 3


ZXSDR B8200 Product Description

Table 2-9 PM3 Panel Interfaces .........................................................................................16


Table 3-1 Physical Indices .................................................................................................21
Table 3-2 BS8200 Capacity ...............................................................................................21
Table 3-3 B8200 Power Supply .........................................................................................22
Table 3-4 ZXSDR B8200 Power consumption ...................................................................22
Table 3-5 ZXSDR BS8200 Interface Indices ......................................................................22
Table 3-6 B8200 Working Environment Characteristics .....................................................23
Table 3-7 ZXSDR B8200 Electromagnetic Compatibility Characteristics............................24
Table 3-8 B8200 Reliability Characteristics ........................................................................24
Table 4-1 B8200 Configuration ..........................................................................................25
Table 5-1 Site Support Cabinet Physical Indices ................................................................28

4 ZTE Confidential & Proprietary


ZXSDR B8200 Product Description

1 Overview

1.1 Introduction

This document provides a high level description of the distributed baseband processing
Unit (BBU) ZXSDR B8200 (hereinafter B8200) that used in ZTE multi-mode wireless
solutions.

The baseband unit B8200, can be inserted into the integrated macro base station, or
connected to RRU in distributed base station. It is responsible for processing the
baseband signals. Based on ZTE SDR platform, it supports GSM, UMTS and FDD LTE
single-mode or multi-mode by software configuration. It enables operators to deploy one
unified radio access network rather than independent GSM, UMTS or LTE network,
which brings simplicity and convenience with low CAPEX and OPEX. Figure 1 shows the
position of the ZXSDR B8200 in the typical multi-mode network.

Figure 1-1 B8200 in the GSM/UMTS/LTE Network

This document is structured as follows. Chapter 1 provides an overview of the


characteristics of B8200, its key benefits and application scenarios. Chapter 2 gives the
architecture, functionality, services and multi-system cooperation. Chapter 3 covers
system capabilities, and chapter 4 introduces configuration principles of each kind of
boards used in B8200.

1.2 Benefits

Multi-mode Baseband Unit

ZTE Confidential & Proprietary 5


ZXSDR B8200 Product Description

B8200 supports all kinds of wireless access technologies simultaneously, including


GSM, UMTS and LTE, which share the common control function and transmission
totally. It fully satisfies operators need with the minimum hardware change.

Large Capacity

To adapt to the rapid expansion of network development and the prosperity of


multi-mode network, the latest BBU boards are released with higher processing
capacity. The capacity indices of new boards surpass legacy ones, including RRC
connected user number, cell number and data throughput. The increase in the
board capacity improves the overall capacity of BBU. In addition, the new boards
can be used together with the legacy ones, which provide flexibility during upgrade.

Plug-in Design for Shelf, Zero Footprint, Convenient Deployment

B8200 adopts Plug-in design with 19-inch, 2U in height and 8.75 kg (with full
configuration) in weight. It can be conveniently mounted on the wall, ground, or in
the 19-inch rack, etc.

Flexible Networking

B8200 provides GE/FE interfaces and IP networking. It supports RRU in different


networking modes, like star and chain networking to satisfy the requirements of
operators in different environments and under different transmission conditions.

1.3 Application Scenarios

As the baseband processing unit, B8200 is widely used in ZTE series of base stations,
including indoor macro BS of ZXSDR BS8800, outdoor macro BS of ZXSDR
BS8900A/BS8900B, distributed BS of ZXSDR BS8700 and outdoor compact BS of
ZXSDR BS8906.

Typical application scenarios of B8200 are shown in the following figure.

6 ZTE Confidential & Proprietary


ZXSDR B8200 Product Description

Figure 1-2 B8200 Application Scenario

RRU Installation
RRU

B8200 Accommodation

B8200

ZTE Confidential & Proprietary 7


ZXSDR B8200 Product Description

2 Product Architecture

2.1 Physical Structure

The following figure shows the hardware appearance of B8200.

Figure 2-1 Baseband Unit -- ZXSDR B8200

1 3 4

1. Power module (PM) 2. Site alarm board (SA) 3. Fabric switch board (FS) 4. Baseband processing
board (BP) 5. Fan array module (FAM) 6. Control & clock board (CC)

The baseband unit consists of control & clock board, fabric switch board, baseband
processing board, site alarm board, site alarm extension board (optional), universal
Ethernet switch (optional), tower mounted amplifier control module (optional), power
module, and fan module.

Table 2-1 Board List of ZXSDR B8200

Board Name Function Description


CC16B Control & Clock Board

FS5 Fabric Switch Board

UBPG3 Universal Baseband Processing board for GSM

BPN2 Baseband Processing board for GUL multi-mode

SA3 Site Alarm Board

PM3 Power Module

FAM Fan Array Module

8 ZTE Confidential & Proprietary


ZXSDR B8200 Product Description

2.2 Hardware Structure

B8200 hardware architecture is shown in Figure 2-2.

Figure 2-2 B8200 Hardware Structure

Baseband Unit
Antenna

Baseband
Processing
FS
CPRI
(Optional RRU/RSU
for LTE)

SA/
E1
SE CC
Radio Unit
GE/FE

Control Signaling
Clock
Data

B8200 can be configured in GSM/UMTS/LTE single mode or multi-mode.

2.2.1 Control & Clock Board (CC16B)

CC is the control & clock board, used for control and management of baseband unit,
providing Ethernet and system clock.

Figure 2-3 CC16B Panel

Note: The boards are differentiated by the label attached on the panel, not included in the above

figure. The product you receive is subject to the actual object.

Their key indices are specified in the following table.

ZTE Confidential & Proprietary 9


ZXSDR B8200 Product Description

Table 2-2 Key Indices of CC16B

CC Type CC16B

Mode G/U/L single mode or multi-mode

UMTS CNBAP 1500/s


Processing Capability

LTE Processing Capability 10800 RRC_connected users


UL: 900Mbps/ DL: 900Mbps

Note: 1. The above table describes the maximum hardware capability. The actual capability is up to

the licenses configured. 2. There is the GPS module embedded in CC16B.

The panel interfaces are specified in the following table.

Table 2-3 CC16B Panel Interfaces

Interface Name Description

External communication port, connected to external


EXT
receiver for clock synchronization or cascading.

Connected to GPS signal interface, or 2 MHz BITS signal


REF
interface.

USB (CC16B only) Used for software upgrade

Ethernet interface for Abis/Iub/S1/X2, self-adaptive


TX RX
100M/1000M optical interface.

Ethernet interface for Abis/Iub/S1/X2, self-adaptive


ETH0
10M/100M/1000M electrical interface.

Ethernet interface used for cascading, debugging or local


DEBUG/CAS/LMT
maintenance, adapting interface of 10M/100M/1000M.

Note: Interfaces of ETH0 and TX RX are mutually exclusive.

Their main functions are listed as follows:

Accomplishes LTE control plane protocol processing, including S1AP, X2AP, RRC,
etc.

Supports Ethernet switching function and implements data switching for service and
control flow within the system

10 ZTE Confidential & Proprietary


ZXSDR B8200 Product Description

Processes Abis/Iub/S1/X2 interface protocol

Manages software versions of boards and programmable components, and


supports local and remote software upgrade

Reads various hardware management marks in the system, including the rack
number, backplane type number, slot number, board function type, board version,
and board function configuration mark

Monitors, controls and maintains the base station system with LMT interface

Supervises the running status of each board within the system

Supports primary/slave switchover

Synchronizes with various external reference clocks, including IEEE1588, GPS


clock and the clock provided by BITS(2MHz2Mbits). The CC can select one
according to the actual configuration

Generates and delivers the clock signal demanded by each part

Provides GPS receiver interface and manages the GPS receiver

Provides a real-time clock for system operation and maintenance and calibrates the
real-time clock

Supports MicroTCA protocol based module management function

Supports 2 CC boards for different modes: one for GU dual-mode and the other for
LTE mode

Supporting Synchronous Ethernet clock

Providing USB interface for software upgrade

2.2.2 Baseband Processing Board

The UBPG3 is GSM baseband processing boards, processing the physical layer protocol
and frame protocol specified by 3GPP, illustrated in the following figure.

ZTE Confidential & Proprietary 11


ZXSDR B8200 Product Description

Figure 2-4 UBPG3 Panel

Note: The boards are differentiated by the label attached at the left-bottom corner, not included in

the above figures. The product you receive is subject to the actual object.

UBPG3 supports 24 TRXs. The main functions are listed as follows:

Supports rate adaptation, channel coding, interleaving, encryption, TDMA shock


burst generation, GMSK/8PSK modulation, and IQ baseband digital signals output

Supports uplink IQ data receiving, receiver diversity combination, digital


demodulation (GMSK&8PSK, equilibrium), decryption, deinterleaving, demodulator,
rate adaptation, and transmits signals from GE Ethernet interfaces to CC board for
processing

Synchronizes radio link and processes transmission frame

Measures parameters required in power control and handover

Supports diversified transmission and receiving

Communicates with CC via Ethernet interface

Reads all the hardware management identifiers, including the backplane type
number, slot number, board function type, board version, board function
configuration identifier, and the CPU serial number

1. BPN2

BPN2 is a GSM/UMTS/LTE multi-mode baseband processing board, integrating all the


functions provided by the G/U/L single mode BP boards. It can be configured as G/U/L
single mode or multi-mode, illustrated in the following figure.

12 ZTE Confidential & Proprietary


ZXSDR B8200 Product Description

Figure 2-5 BPN2 Panel

Note: The boards are differentiated by the label attached at the left-bottom corner, not included in

the above figures. The product you receive is subject to the actual object.

They provide the same functions but with different processing capabilities. The key
indices are specified in the following table.

Table 2-4 Key Indices of BPN2

Board BPN2

CPRI Interfaces 6 pairs

GSM 72 TRXs

12 CSs(1024CEs)
UMTS
DL 518.4Mbps/UL 138Mbps

12 2T2R/2T4R Cells or 6 4T4R Cells


LTE 7200 RRC_connected Users
DL 1200Mbps/UL 600Mbps

12 TRXs + 12 CSs(768CEs)
24 TRXs + 9 CSs(640CEs)
GU dual-mode
36 TRXs + 6 CSs(512CEs)
48 TRXs + 6 CSs(256CEs)

GL dual-mode 36 TRXs + 6 Cells

UL dual-mode 6 CSs(512CEs) + 6 Cells

12 TRXs + 6 CSs(256CEs) + 6 Cells


GUL multi-mode
24 TRXs + 3 CSs(128CEs) + 6 Cells

Note: The above table describes the maximum hardware capability. The actual capability is up to

the licenses configured.

The panel interfaces are specified in the following table.

ZTE Confidential & Proprietary 13


ZXSDR B8200 Product Description

Table 2-5 BPN2 Panel interfaces

Board Type Interface Description

6 pairs of CPRI optical/electrical interfaces,


BPN2 TX0 RX0 ~ TX5 RX5
connected to RRU/RSU

2.2.3 Fabric Switch Board (FS)

FS5 is fabric switch board which provides the optical interface between BBU and RRU
and processes the IQ signal.

Figure 2-6 FS5 Panel

Note: The boards are differentiated by the label attached at the left-bottom corner, not included in

the above figures. The product you receive is subject to the actual object.

Their key indices are specified in the following table.

Table 2-6 Key Indices of FS boards

FS Type FS5

Mode G/U/L single mode or multi-mode

Max. CSs, working with one UMTS BP


12
board

Max. CSs, working with UMTS BP


60
boards per BBU

CPRI Interface Data Rate (Gbps) 1.2288/2.4576/3.072/6.144

The panel interfaces are specified in the following table.

Table 2-7 FS Panel Interfaces

Interface Name Description

TX0 RX0 to TX5 RX5 6 pairs of optical/electrical interfaces, connected to RRU/RSU

14 ZTE Confidential & Proprietary


ZXSDR B8200 Product Description

ETH (CR0 only) 10GE Ethernet interface, connected to BBU

Their main functions are listed as follows:

Receives the signal from the rear board in the downlink and retrieves the data and
timing.

Multiplexes the received data and retrieves I/Q signal

Supports I/Q mapping in the downlink and multiplexes I/Q signal to the optical
signals

Receives the I/Q in uplink and de-multiplexes/maps into I/Q signal

Transmits the multiplexed I/Q signal to baseband processing board

Exchanges the CPU interface signaling through HDLC interface with RU module

2.2.4 Site Alarm Board (SA3)

SA is a site alarm board, illustrated in the following figure.

Figure 2-7 SA3 Panel

Note: The product you receive is subject to the actual object.

The SA3 boards interfaces specified in the following table.

Table 2-8 SA Panel Interfaces

Interface Name SA3

- 4 E1/T1 interfaces

14+2 dry contacts (14 input, 2


bidirectional)

ZTE Confidential & Proprietary 15


ZXSDR B8200 Product Description

Interface Name SA3

1 RS485 interface

1 RS232 interface

The SA3 has the following functions:

Provides E1/T1 transmission interfaces

Provides site alarm monitoring interfaces

Provides FAM's alarm and rate control

Supports signal monitoring and interface lightning protection

The last E1 used for E1 transmission or BITS-2MHz/BITS-2Mbps clock input

2.2.5 Power Module (PM3)

PM3 is the power module, shown in the following figure.

Figure 2-8 PM3 Panel

Note: The boards are differentiated by the label attached at the left-bottom corner, not included in

the above figures. The product you receive is subject to the actual object.

The panel interfaces are specified in the following table.

Table 2-9 PM3 Panel Interfaces

Interface Name Description

MON Debugging interface, RS232 interface

-48V/-48VRTN -48V input

16 ZTE Confidential & Proprietary


ZXSDR B8200 Product Description

ON/OFF (PM3 only) Power switch, turning on/off 12V power to/from BBU

The PM3 has the following functions:

Provides 16 internal interfaces for +12 V, +13V or +28V load power;

Provides 16 internal interfaces for +3.3 V management power;

Supports EMMC management;

Supports measurement and protection of input over-voltage/under-voltage;

Supports output over-current protection and load power management.

2.2.6 Fan Array Module (FAM)

FAM is fan array module. Its panel is illustrated in the following figure.

Figure 2-9 FAM Panel

Note: The product you receive is subject to the actual object.

The FAM has the follows functions:

Monitors and controls system temperature;

ZTE Confidential & Proprietary 17


ZXSDR B8200 Product Description

Monitors, controls, and reports the fan state.

2.3 Software Architecture

The software architecture of the ZXSDR B8200 can be divided into three layers:

Application software layer

Platform software layer

Hardware layer

Figure 2-10 B8200 Software Structure

GSM/UMTS/LTE Application Software

LMT SCS OAM DBS BRS


NOP

OMC-B OSS

Linux

Hardware (BSP)

The application software layer provides functions as follows:

RNLC (radio network layer control) provides common and dedicated radio resource
management and control functions for control plane

RNLU (radio network layer user) provides user plane function

SCHEDULER (scheduler sub-system) provides uplink/downlink MAC scheduling

PHY (physical layer) provides PHY function

18 ZTE Confidential & Proprietary


ZXSDR B8200 Product Description

The SDR platform software provides the functions of Operation Support Sub-system
(OSS), Operating And Maintenance (OAM), Data Base Sub-system (DBS), Bearer
Sub-system (BRS) and System Control Sub-system (SCS):

OSS is the support layer in this entire framework, which is a hardware independent
platform for running software and provides basic functions like scheduling, timer,
memory management, communication, sequencing control, monitoring, alarming
and logging.

OAM provides the configuration, alarm and performance measurement function for
base station.

DBS is the database system.

BRS provides the IP communication function for inter-board and inter-network


elements.

SCS provides the power control and system management function.

Board Support Package (BSP) is the software closely connected with the board
hardware and supports Real Time Operation Support Sub-system (RT OSS) to work on
the board.

2.4 Functionality

B8200 implements the following basic functions on Abis/Um/Uu/S1/X2 and O&M


interfaces:

Channel coding and decoding

Channel multiplexing and de-multiplexing

Baseband resource pooling function

Measurement and report

Power control

Spatial multiplexing, transmit diversity and receive diversity

ZTE Confidential & Proprietary 19


ZXSDR B8200 Product Description

Synchronization

Operation and Maintenance

DTX

20 ZTE Confidential & Proprietary


ZXSDR B8200 Product Description

3 Technical Specifications

3.1 Physical Indices

Table 3-1 Physical Indices

Item Indices

Size (H*W*D) (mm) 88.4*482.6*197

Weight (kg) 8.75 (full configuration)

3.2 Capacity Indices

Table 3-2 BS8200 Capacity

Mode Capacity BBU Configuration

GSM 360 TRXs 1CC16B+5BPN2+1FS+2PM+1SA

60 CSs

UMTS 5120 CEs UL/5120 CEs DL 1CC16B+5BPN2+1FS+2PM+1SA

690 Mbps UL /1000 Mbps DL

36x20MHz cells (4T4R)

LTE 21600 RRC_connnected users 2CCE1+6BPN2+2PM+1SA

3.6Gbps UL/7.2Gbps DL

Note: 1. CC16B board supports GE/FE interface and thus limits the total data throughput to

1000Mbps in the physical layer (900Mbps in application layer for LTE single mode). 2. The above

table describes the maximum hardware capacity. The actual capacity is up to the licenses

configured.3. GUL multi-mode capacity can be calculated according the capacity of the configured

CC boards and BP boards.

ZTE Confidential & Proprietary 21


ZXSDR B8200 Product Description

3.3 Power Indices

3.3.1 Power Supply

B8200 power supply is shown in the following Table.

Table 3-3 B8200 Power Supply

Power Options Description


DC: -48 V (-57 V -40 V DC) Supported by integrated PM modules

The power supply is already certified for the following markets.

3.3.2 Power Consumption

The power consumption depends on traffic load, configuration and environment


temperature. The following table provides power consumption of typical configuration.

Table 3-4 ZXSDR B8200 Power consumption

Items Power Consumption (W)

24 TRXs/1 UBPG3 80

24 TRXs + 3 CSs(128CEs) + 6 Cells /1 BPN2 120

12 TRXs + 6 CSs(256CEs) + 6 Cells/1 BPN2 120

3.4 Interface Indices

Table 3-5 ZXSDR BS8200 Interface Indices

Interface Item Indices Type Standard

Abis/Iub ITU G.703/G.704


E1/T1 8 pairs DB44
(CC16B) ANSI T1.403

22 ZTE Confidential & Proprietary


ZXSDR B8200 Product Description

1
10M/100M/1000M 10/100/1000BASE-
electrical RJ45 T IEEE 802.3
Auto-Negotiation. compatible
Abis/Iub/S1/X2 Ethernet Auto-MDI/MDIX
(CC16B) (either or) 1000BASE-LX
IEEE 802.3
1 1000M optical
SFP (LC) compatible,
Or 1 100M optical
100BASE-FX IEEE
802.3 compatible

1
Cascading,
10M/100M/1000M 10/100/1000BASE-
Debugging or
Ethernet electrical RJ45 T IEEE 802.3
Local
Auto-Negotiation. compatible
Maintenance
Auto-MDI/MDIX

6 pairs
Baseband Electrical
/FS/BPN0A/BPN0 SFP (LC) CPRI
/Radio /Optical
/BPN2

GPS TX/RX Port


Clock GPS 1 SMA
NMEA 0183 V3.0

Dry 32 pairs (8,16 or


Monitor DB44 N/A
contacts 24 pairs optional)

External EXT 1 RS485/RS2


N/A
32

3.5 Environment Indices

Table 3-6 B8200 Working Environment Characteristics

Item Requirement

Temperature -20 to +55C

Relative Humidity 5% to 95%

Protection classification Compliant with IP20

ETSI EN 300 386


Emission and Immunity
ETSI TS 125 113

ZTE Confidential & Proprietary 23


ZXSDR B8200 Product Description

Item Requirement

5 ; earth resistance can be less than 10 in


Ground lightning-less area with less than 20 lightning storms a
year.

Mechanical vibration ETSI 300019-1-4 ClassM4.1

3.6 Electromagnetic Compatibility Indices

Table 3-7 ZXSDR B8200 Electromagnetic Compatibility Characteristics

Item Requirement

Anti-static protection Capable of protecting against a contact discharge of


6000V, Air discharge of 8000V.

Surge anti-interference 2000V between lines and ground.

3.7 Reliability Indices

The reliability of the ZXSDR B8200 system conforms to the national military GJB/Z299B
Electronic Equipment Reliability Estimation Manual and the IEC TR62390 standard.

The Reliability characteristics vary at different configurations. The reliability indices are
calculated based on typical configuration supporting GUL multi-mode, listed in table 3-8.

Table 3-8 B8200 Reliability Characteristics

Item Value

MTBF 240,000 hours

MTTR 0.5 hour

Availability index 99.999792%

Down duration 1.095 min/year

24 ZTE Confidential & Proprietary


ZXSDR B8200 Product Description

4 Configurations Principles
B8200 is the baseband unit of macro base station, which is composed of the following
boards: CC, BP, FS, SA/SE, UES, TAM, PM, FAM, etc. Configuration principles of these
boards are described in the following table:

Table 4-1 B8200 Configuration

Board Configuration Principles


Refer to table 2-2 for the key indices of CC boards. At least 1 board
is configured by default.
CC
Maximally 2 boards can be configured for GU and LTE respectively
or 1+1 backup.

UBPG3 24 GSM TRXs/board. Maximally 5 boards can be configured.

BP Refer to table 2-8 for the key indices. Maximally 6 boards can be
BPN2
configured in LTE single mode or 5 boards in GUL multi-mode.

Refer to table 2-10 for the key indices of FS boards. At least 1


FS board is configured by default for G/U mode. FS is optional in LTE
single mode configuration. Maximally 2 boards can be configured.

Refer to table 2-12 for the interfaces of the 2 types of SA boards.


SA
It is configured by default.

At least 1 board is configured by default.


PM
Maximally 2 boards can be configured for 1+1 backup.

FAM It is configured by default.

Note: The above table describes the maximum hardware capacity. The actual capacity is up to the

licenses configured.

ZTE Confidential & Proprietary 25


ZXSDR B8200 Product Description

5 Site Support Cabinets for B8200


When used outdoor, B8200 is usually put into the site support cabinets. Three types of
cabinets are provided with certain water- and dust-proof capability, satisfying different
accommodation requirements on power, transmission or other third-party equipments.
The details are as follows.

5.1 BC8910A

BC8910A is the medium-sized one in the three cabinets. It can be used when there are
auxiliary devices should be contained but without battery. There are mainly five parts in
BC8910A: baseband unit, power supply system, power distribution module, heat
exchanging system and reserved space for transmission or other equipments. Together
with the fan system and ventilation vessel, the heat exchanger located in the cabinet
door makes the heat exchanging system. The fan system contains fan control element
(FCE) and 6 fans. BC8910A hardware architecture is shown in the following figure.

Figure 5-1 Physical Structure of BC8910A (AC Power Supply)

1. Fan and ventilation vessel 2.AC/DC power system 3. B8200 4.Cable chute 5.Lightning
Protection 6.Reserved space (for transmission, etc) 7.Heater 8.Heat exchange

In the case of DC power supply, AC/DC power system (5U) should be replaced by DC
power distribution with 2U in height.

26 ZTE Confidential & Proprietary


ZXSDR B8200 Product Description

Figure 5-2 Physical Structure of BC8910A (DC Power Supply)

1. Fan and ventilation vessel 2.DC power system 3.B8200 4.Cable chute 5.Lightning protection
6.Reserved space (for transmission, etc) 7.Heater 8.Heat exchange

5.2 ZXSDR BS8906

ZXSDR BS8906 is the smallest one out of three cabinets. It is the outdoor compact base
station, with two kinds of cabinets: compact Cabinet, consisting of BBU, RSU and
supporting modules, and standalone cabinet, consisting of BBU and supporting modules.

If used outdoor for containing BBU without many ancillary devices, standalone cabinet
can be chosen to accommodate BBU inside. The physical structures are shown in the
following figure.

Figure 5-3 Physical Structure of ZXSDR BS8906 Standalone Cabinet


Standalone Cabinet

5
2

6
3

1. Fan control element 2.B8200 3. AC/DC protection module 4. Fan and ventilation vessel 5. Power
supply unit 6. Lightning protection/MW indoor unit/SDH

ZTE Confidential & Proprietary 27


ZXSDR B8200 Product Description

5.3 Physical Indices

Table 5-1 Site Support Cabinet Physical Indices

ZXSDR BS8906
Item BC8910B/BC8911B BC8910A
(Standalone)

Dimension (H*W*D)
With silencing cover:
(mm *mm*mm) 800*600*600 670*300*525
1600*700*780
(Without the base)

Weight (kg) Iron: Iron:


(Full configuration 215(AC)/190(DC) 99 (AC)/76(DC)
35
without battery and Aluminum: Aluminum:
base) 180Kg(AC)/150(DC) 79(AC)/56(DC)

BBU Number 2 1 1

Battery Capacity 1~2*150AH AGM or N/A


N/A
1~2*135AH GEL

Reserved space for BC8910B: 4U 4U (AC) N/A


transmission etc. BC8911B: 11U 8U (DC)

Note: If needed, the base is additionally configured for BC8910B/BC8911B, and the
cover and base are additionally configured for BC8910A.

28 ZTE Confidential & Proprietary


ZXSDR B8200 Product Description

6 Glossary
Abbreviations Full Characteristics
rd
3GPP 3 Generation Partnership Project

BP Baseband Processing

BBU Base Band processing Unit

BITS Building Integrated Timing Supply


BSP Board Support Package

CAPEX Capital Expenditure

CC Control & Clock module

CPRI Common Public Radio Interface

DBS Data Base Sub-system

DL Downlink

DTX Discontinuous transmission

EUTRAN Evolved Universal Mobile Telecommunications System

FAM Fan Module

FE Fast Ethernet

FS Fabric Switch board

GE Gigabit Ethernet

GPS Global Positioning System

GSM Global System for Mobile communications

HSPA+ HSPA Evolution

LMT Local Maintenance Terminal

LTE Long Term Evolution

MDLSD MAC Downlink Schedule

MicroTCA Micro Telecommunications Computing Architecture

MIMO Multi Input Multi Output

MTBF Mean Time Between Failures

MTTR Mean Time To Recovery

MULSD MAC Uplink Schedule

OAM Operating Administration and Maintenance

OFDMA Orthogonal Frequency Division Multiple Access


OPEX Operation Expenditure

ZTE Confidential & Proprietary 29


ZXSDR B8200 Product Description

Abbreviations Full Characteristics


OSS Operation Support Sub-system

PHY Physical Layer

PM Power Module

RNLC Radio Network Layer Control Plane

RNLU Radio Network Layer User Plane

RRU Remote Radio Unit

SA Site Alarm Board

SC-FDMA Single Carrier Frequency Division Multiple Access


SDR Software Defined Radio

SE Site Alarm Extension board

UE User Equipment
UL Uplink

UTRAN UMTS Terrestrial Radio Access Network

WCDMA Wideband Code Division Multiple Access

WiMAX Worldwide Interoperability for Microwave Access

30 ZTE Confidential & Proprietary

S-ar putea să vă placă și