A10V(S)O Pressure/Flow control DFR(1)

Ports

Pressure port B Pressure control DR

Standard setting:
Case drain port L
A10VODFR/31: 280 bar
A10VODFR/52: 250 bar

Flow control FR

(p = 10 - 22 bar)

Standard setting:
p = 14 bar
X - Pilot pressure port

Suction port S
(viewed A10VO, BR 31, clockwise)

A10 146.e/VST6/H 01.AK


A10V(S)O Pressure/Flow control DFR(1)
Circuit diagram

Adjustable orifice, 9 X - port


(6) res.
Flow control
Mobile valve block 2 7
3 (Standard:
(not included in
p = 14 bar);
supply)
Spring force (5)
FR
4 Decompression
orifice
1
DR Pressure spring

Damping orifice

Control piston (8)

(Circuit diagram
viewed for A10VO,
series 31) Bias piston and spring

A10 146.1.e/VST6/H 01.AK


A10V(S)O Pressure/Flow control DFR(1)
Circuit diagram

Adjustable orifice, X - port


res.
Flow control
Mobile valve block
(Standard:
(not included in
p = 14 bar);
supply)
FR
Decompression
orifice

DR Pressure port

Damping orifice

Control piston

(Circuit diagram
viewed for A10VO,
series 31) Counter balance piston and mechanical spring

A10 146.2.e/VST6/H 01.AK


A10V(S)O Pressure/Flow control DFR(1)
Function and circuit diagram
Orifice res. Mobile LS - pilot pressure
valve block

FR

DR

DR - axis

FR - axis

A10 146.3.e/VST6/H 01.AK


A10V(S)O Pressure/Flow control DFR(1)
p - control characteristic f (x) = (px, Vg)

High pressure: p HD Simulated load


pressure: p X

220
210
200 p = 15 bar
190
180 A10 VO 74 DFR(1)
170
160
150
140
130
120
Mode of experimental procedure:
110
100
90
n = 1500 rpm
80 p = 15 bar
70 Stand by = 20 bar
60
pHD
50
px
40
30 X
20 DFR1
10
0
0 25 50 75 100
Frdermenge in

A10 146.4.d/VST6 01.AK


A10V(S)O Pressure/Flow control DFR(1)
Decompression orifice and damping orifice
DFR with decompression orifice:
(DFR: Standard: 0,35 mm)
(DFR1: closed, without drilling)
X

FR
FR - axis

DR
DR - axis

Damping orifice DR - FR
(Standard: 0,6 mm,
Slit in longitudinal direction: orifice opened
Slit in cross direction : orifice closed, SO 74)

A10 146.5.e/VST6/H 01.AK


A10V(S)O Pressure/Flow control DFR(1)
Damping orifice

Damping orifice DR - FR
(Standard: 0,6 mm,
Slit in longitudinal direction: orifice opened
Slit in cross direction : orifice closed,
(SO 74)
pressure increase of the valve (pHD = 200 bar)
p [bar]

250 250,0
closed
open
200 200,0

150 150,0

100 100,0

50 50,0

0 0,0
0,000 0,050 0,100 0,150 0,200 0,250 0,300 0,350 0,400 0,450 0,500
x [m m ]
adjusting path of the piston

A10 146.6.e/VST6/H 01.AK


A10V(S)O Pressure/Flow control DFR(1)
Measurement of high pressure

Attention:

The mini - measurement


connection have to be
shortened according to the
original lenght of the plug
(reach of a screw 7 mm).

Measurement high pressure:

At this particular spot, the


existing plugs (M8 x 1) can
be replaced by mini measure-
ment connections

A10 146.7.e/VST6/H 01.AK


A10V(S)O Pressure/Flow control DFR(1)
Adjustment for pressure- res. flow control
Adjustment of pressure control Adjustment of
flow control:

Stand - by pressure
measurement

or

Differential pressure
measurement with
swivel angle !

Valve axis: Valve axis:


Pressure control Flow control

A10 146.8.e/VST6/H 01.AK


A10V(S)O Pressure/Flow control DFR(1)
Adjustment of pressure control DR

Procedure:
FR - flow control blocked !
High pressure line closed !
Adjusting of DR pressure control X
with setting value !
FR
Measuring - point 1: High pressure
(measurable at plug of DR valve axis)
DR
Adjustment DR : each rotation
app. 50 bar !

- 50 bar
+ 50 bar

A10 146.9.e/VST6/H 01.AK


A10V(S)O Pressure/Flow control DFR(1)
Adjustment of flow control FR

1. Stand by pressure measurement:


Procedure:

X - port unloaded to tank !


X
close high pressure port !
Standard adjustment FR p = 14 bar
FR
(When port X is unloaded to tank, a zero
stroke pressure of p = 16 1 bar stand by
results. DR
Measuring - point 1: zero stroke pressure
(measurable at plug of valve axis)
- 16 bar
+ 16 bar

A10 146.10.e/VST6/H 01.AK


A10V(S)O Pressure/Flow control DFR(1)
Adjustment of flow control FR

2. Possibility: Differential pressure measurement :

X
Measuring - point 1: load pressure
corresponding to pressure of port X !
( LS - signal )
FR

Measuring - point 2: High pressure


DR

(measureable at plug of valve axis)

- 16 bar
+ 16 bar

A10 146.11.e/VST6/H 01.AK


A10V(S)O Pressure/Flow control DFR(1)
Differences between DFR and DFR1

DFR - design
With decompression orifice !
(DFR: Standard: 0,35 mm
glued in place, fastened with Loctide)

DFR1 - design
Without decompression orifice !
(DFR1: closed, without drilling)

A10 146.12.e/VST6/H 01.AK


A10V(S)O Pressure/Flow control DFR(1)
Usage DFR(1) for series 31 and 52 !

A10 - series 31: A10 - series 52:


DFR(1) - without return line DFR(1) - with return line orifice
orifice ! (Standard: 2,2 mm !)

FR

DR
Special design (Stabilization):
SO 116: Return line orifice 1,3 mm
SO 229: Return line orifice 1,5 mm
SO 231: Return line orifice 2,2 mm
SO 277: Return line orifice 1,0 mm
SO 381: Return line orifice 0,8 mm
SO 617: Return line orifice 0,6 mm

A10 146.13.e/VST6/H 01.AK


A10V(S)O Pressure/Flow control DFR(1)
Mounting of DFR(1) control (series 31)

Mounting of DFR(1) - control (A10V(S)O series 31) depends on


direction of rotation (Direction of rotation by view on drive shaft) !

A10 146.14.e/VST6/H 01.AK


A10V(S)O Pressure/Flow control DFR(1)
Different designs

DFR(1) for A10V(S)O DFR(1) for A10V(S)O


Size 18 - 100 Size 140

Standard design ! Design in sandwich - plate


design !

A10 146.15.e/VST6/H 01.AK