1 MODEL CODE
Options (2):
V = regulating handwheel instead of a grub screw protected by cap
VF = regulating knob instead of a grub screw protected by cap (only for AGIS, AGIU)
VS = manual override with safety locking instead of a grub screw protected by cap
Pilot valve (1):
(only for AGIS, AGIU)
I = DHI for AC and DC supply,
Only for AGIU:
D = internal drain
WP = prolonged manual override protected by rubber cap (1) with CURUS certified solenoids
- E = DHE for AC and DC supply, high performances
with CURUS certified solenoids
= standard unloading characteristics
5, 6, 7 = other unloading characteristics, see section
(1) Only for AGIU with solenoid valve for venting (2) For handwheel features, see technical table K150
C070
2 HYDRAULIC CHARACTERISTICS
Valve model AGIR-10 AGIR-20 AGIR-32 AGIS-10 AGIS-20 AGIS-32 AGIU-10 AGIU-20 AGIU-32
Max flow [l/min] 160 300 400 200 400 600 100 200 300
Pressure range [bar] 450 (AGIR*); 6100; 7210; 8350
Max pressure [bar] Ports A, B, X = 350 bar Port Y = 0
3 MAIN CHARACTERISTICS, SEALS AND FLUIDS - for other fluids not included in below table, consult our technical office
Insulation class DHI pilot H (180C) Due to the occuring surface temperatures of the
solenoid coils, the European standards EN ISO 13732-1
DHE pilot H (180C) for DC coils F (155C) for AC coils and EN ISO 4413 must be taken into account
Protection degree to DIN EN 60529 IP 65 (with connectors 666, 667, 669 or E-SD correctly assembled)
Relative duty factor 100%
Supply voltage and frequency See electric feature
Supply voltage tolerance 10%
Certification CURUS North American standard
4 REGULATED PRESSURE VERSUS FLOW DIAGRAMS based on mineral oil ISO VG 46 at 50C
AGIR-10 AGIR-20 AGIR-32
5 OPERATING DIAGRAM
based on mineral oil ISO VG 46 at 50C
1 = AGIR-10 A B
Min regulated pressure [bar]
2 = AGIR-20 A B
3 = AGIR-32 A B
4 = AGIR-10 B A
5 = AGIR-20 B A
6 = AGIR-32 B A
7 = AGIS-10
8 = AGIS-20
9 = AGIS-32
NOTES
1)Short pipes with low resistance must be
used between the unloading valve and
Regulated pressure [bar]
the accumulator;
2)When the resistance is high, the hydraulic
pilot signal must be taken as closed as
possible to the accumulator;
3)With high pump flow and small valve
differential pressure of intervention it is
unadvisable to use the version with
external drain;
4)When to use the BA-*25 subplates:
a) in applications with working frequencies
>10 Hz use subplates type BA-*25/4 1 2 3 4 1 2 3 4
(spring with 4 bar of cracking pressu-
re);
b) in applications with working frequencies
<10 Hz use subplates type BA-*25/2
(spring with 2 bar of cracking pressure);
C070
6 ELECTRIC CONNECTORS ACCORDING TO DIN 43650 FOR AGIU WITH SOLENOID VALVE
The connectors must be ordered separately
8 DIMENSIONS [mm]
122
50.5
119
Ports A, B: = 14 mm
58.7
Ports X, Y: = 5 mm
33.3
7.9
20
20
21.4
7.1
31.8
35.7
42.9
50.5
42.5 50.5
40
20
24
40
30
150
20
110
80
30
25
122
50.5
119
Tightening torque = 70 Nm
39.7
Seals: 2 OR 109/70, 2 OR 4100 6.4
Ports A, B: = 22 mm
20.6
20
11.1
20
Ports X, Y: = 5 mm
39.7
44.5
49.2
60.3
view from X 38 127 50.5 54 127 50.5
AGIU-20/10/**-IX AGIU-20/10/**-EX
Mass = 7,5 Kg Mass = 7,8 Kg
50.5
50.5
40
42.5
20
40
24
30
178
20
128
98
40
25
122
6 socket head screws M10x45 class 12.9 119
Tightening torque = 70 Nm 96.8
Seals: 2 OR 109/70, 2 OR 4131 92.9
20
20
Ports A, B: = 28 mm 48.4
4
Ports X, Y: = 5 mm
16.7
24.6
42.1
59.6
62.7
67.5
84.1
24 142.5 49 40 142.5 49
AGIU-32/10/**-IX AGIU-32/10/**-EX
view from X
Mass = 11,4 Kg Mass = 11,7 Kg
50.5
40
50.5
20
42.5
40
24
30
230
20
160
130
60
25
9 MOUNTING SUBPLATES
02/17