Documente Academic
Documente Profesional
Documente Cultură
OUTSIDE 35 C
HUMIDITY 90%
22 C Inside
PROVIDED BY
HEINEN & HOPMAN
Option Classification
With our wide range of fans, we can The axial fans are available in RMRS
offer you the ultimate ventilation different materials:
system for each situation. Our high - galvanized steel (standard)
quality fans are designed to with- - primed and painted steel
stand all climate conditions. The fans - marine corrosion-resistand
comply with all requisite class and aluminium
government regulations. - stainless steel LR
ATEX
The fans can optionally be supplied in
explosion-proof design. ABS
BV
Our mission:
To ensure you the
perfect climate indoors, RRR
regardless of the
weather outside.
igw fans
Application
The high-performance IGW axial fans are sturdily
designed. The fans have a low noise level and relatively
constant power consumption in the different working
points (maximum 10%).
Casing
Made of heavy gauge plates and structural steel,
free from grease and oil and with negligible surface
oxidation. Flanges are on both sides according to
DIN24154-2:1990-07. Optimal surface protection
thanks to hot-dip galvanizing. Optimized aerodynamic
guide vane in the casing.
Impeller
Optimized aerodynamic impeller with a high-
performance direct-drive motor. The impeller has
a sea-water-resistant cast made of aluminum. The
taper lock connection is for easy installation on the
motor shaft.
Drive
3-phase direct drive motor with flange-motor
optimized performance. Protection class IP55 (IP65
possible). Isolation class F/B. Motors are available for
mains supply at 50 Hz and 60 Hz.
To offer
complete operational
security to those
who ensure
ours
Specification IGW series
Size Motor l s d d3 d5 n d4 i h r m
diameter size
DN (mm) (mm) (mm) (mm) (mm) (mm) (mm) (mm) (mm) (mm)
250 63-80 330 3 (4.6) 254 292 292 8 12 270 200 200 300
280 63-90 375 3 (4.6) 284 332 332 8 12 315 225 233 333
63-80 350 3 (4.6) 319 366 406 8 12 290 245 275 375
315
90 460 340 245 275
71-80 360 3 (4.6) 359 405 445 8 12 300 270 316 416
355
90-112 460 400 270 316
71-90 420 3 (4.6) 404 448 488 12 12 320 300 350 450
400
100-112 480 380 300 350
71-90 510 3 (4.6) 456 497 537 12 12 410 340 400 500
450
100-132 570 470 340 400
71-100 520 3 (4.6) 506 551 591 12 12 420 375 450 550
500
112-160 680 580 375 450
80-100 570 3 (4.6) 567 629 673 16 14 470 415 525 625
560
112-160 700 600 415 525
80-112 590 3 (4.6) 637 698 742 16 14 490 460 566 666
630
132-180 850 750 460 566
90-132 640 3 (4.6) 717 775 819 16 14 480 510 550 750
710
160-200 905 745 510 550
100-132 670 3 (4.6) 810 861 905 24 14 510 570 633 833
800
160-225 960 800 570 633
100-160 905 3 (4.6) 910 958 1002 24 14 745 620 800 1000
900
180-225 1020 860 620 800
112-180 905 3 (4.6) 1012 1067 1111 24 14 745 675 900 1100
1000
200-280 1230 1070 675 900
132-200 1060 3 (4.6) 1133 1200 1254 32 18 900 745 1050 1250
1120
225-280 1300 1140 745 1050
160-225 1090 3 (4.6) 1267 1337 1391 32 18 890 815 2x575 1350
1250
250-280 1320 1120 815 2x575
1400 180-250 1230 6 1418 1475 1552 32 18 1030 900 2x650 1500
1600 200-250 1230 6 1619 1675 1753 40 18 1030 1000 3x516 1750
1800 225-250 1250 6 1821 1875 1955 40 18 1050 1100 3x560 1900
Dimensions in mm
Alternatives available on request.
Due to continued product development, Heinen & Hopman reserves the right to introduce alternations without prior notice.
Direct drive 50Hz
Total pressure 125 Pa Total pressure 160 Pa
Volume Shaft Motor Sound Sound Total Volume Shaft Motor Sound Sound Total
Fan Size Speed Fan Size Speed
flow rate Power power pressure power mass flow rate Power power pressure power mass
Volume Shaft Motor Sound Sound Total Volume Shaft Motor Sound Sound Total
Fan Size Speed Fan Size Speed
flow rate Power power pressure power mass flow rate Power power pressure power mass
Volume Shaft Motor Sound Sound Total Volume Shaft Motor Sound Sound Total
Fan Size Speed Fan Size Speed
flow rate Power power pressure power mass flow rate Power power pressure power mass
Volume Shaft Motor Sound Sound Total Volume Shaft Motor Sound Sound Total
Fan Size Speed Fan Size Speed
flow rate Power power pressure power mass flow rate Power power pressure power mass
Volume Shaft Motor Sound Sound Total Volume Shaft Motor Sound Sound Total
Fan Size Speed Fan Size Speed
flow rate Power power pressure power mass flow rate Power power pressure power mass
m3/h DN min-1 kW kW dB(A) dB(A) kg m3/h DN min-1 kW kW dB(A) dB(A) kg
4000 500 2838 1,5 2,2 51-1m 103 40 4000
4500 500 2838 1,7 2,2 52-1m 104 40 4500
5000 500 2842 1,8 2,2 52-1m 104 40 5000 500 2863 2,4 3,0 54-1m 106 46
5600 450 2842 1,9 2,2 49-1m 101 34 5600 500 2863 2,4 3,0 41-1m 103 46
6300 400 2863 2,1 3,0 45-1m 97 36 6300 450 2863 2,5 3,0 47-1m 99 40
7100 450 2863 2,3 3,0 46-1m 98 40 7100 450 2863 2,9 4,0 48-1m 100 57
8000 450 2863 2,5 3,0 46-1m 98 40 8000 450 2871 3,3 4,0 48-1m 100 57
9000 500 2863 2,8 4,0 46-1m 98 63 9000 450 2871 3,5 4,0 49-1m 101 57
10000 500 2871 3,0 4,0 46-1m 98 63 10000 500 2892 3,6 5,5 49-1m 101 78
11200 560 2871 3,4 4,0 48-1m 99 69 11200 560 2892 4,0 5,5 51-1m 102 84
12500 560 2892 3,7 5,5 50-1m 100 84 12500 560 2900 4,3 5,5 52-1m 102 84
14000 630 2892 4,7 5,5 50-1m 100 91 14000 630 2900 5,5 7,5 56-1m 105 94
16000 710 1441 5,7 7,5 49-1m 99 116 16000 710 1441 6,7 11,0 59-1m 107 158
18000 710 1441 6,1 7,5 51-1m 100 116 18000 710 1441 7,6 11,0 55-1m 104 158
20000 800 1441 6,4 7,5 52-1m 100 163 20000 800 1458 8,6 11,0 50-1m 101 205
22400 800 1441 7,1 11,0 51-1m 100 205 22400 800 1458 8,7 11,0 51-1m 102 205
25000 800 1458 7,8 11,0 49-1m 100 205 25000 800 1459 8,8 11,0 51-1m 102 235
28000 900 1458 8,3 11,0 50-1m 101 235 28000 900 1459 10,5 15,0 53-1m 103 256
31500 900 1459 8,7 11,0 50-1m 101 235 31500 900 1459 12,1 15,0 55-1m 103 256
35500 1000 1459 10 15,0 52-1m 101 283 35500 1000 1459 13,4 18,5 56-1m 104 303
40000 1000 1459 11,4 15,0 53-1m 101 283 40000 1120 1464 14,7 18,5 56-1m 104 397
45000 1120 1459 13,4 15,0 54-1m 102 277 45000 1120 1464 16,3 18,5 56-1m 104 397
50000 1120 1464 15,5 18,5 55-1m 103 297 50000 1120 1469 18,0 22 56-1m 104 417
55000 1250 1464 16,9 18,5 55-1m 103 271 55000 1250 1469 21,1 30 56-1m 104 568
63000 1250 977 18,3 22,0 54-1m 102 596 63000 1250 977 24,3 30 56-1m 104 666
71000 1400 977 20,4 30,0 54-1m 102 763 71000 1400 977 26,5 30 57-1m 105 763
80000 1400 977 22,6 30,0 54-1m 102 763 80000 1400 979 28,7 37 57-1m 105 858
90000 1600 977 25,1 30,0 55-1m 103 906 90000 1600 979 32,4 37 58-1m 106 1001
100000 1600 979 27,6 37,0 56-1m 104 1001 100000 1600 981 36,0 45 58-1m 106 1216
Volume Shaft Motor Sound Sound Total Volume Shaft Motor Sound Sound Total
Fan Size Speed Fan Size Speed
flow rate Power power pressure power mass flow rate Power power pressure power mass
Volume Shaft Motor Sound Sound Total Volume Shaft Motor Sound Sound Total
Fan Size Speed Fan Size Speed
flow rate Power power pressure power mass flow rate Power power pressure power mass
Volume Shaft Motor Sound Sound Total Volume Shaft Motor Sound Sound Total
Fan Size Speed Fan Size Speed
flow rate Power power pressure power mass flow rate Power power pressure power mass
Volume Shaft Motor Sound Sound Total Volume Shaft Motor Sound Sound Total
Fan Size Speed Fan Size Speed
flow rate Power power pressure power mass flow rate Power power pressure power mass
Volume Shaft Motor Sound Sound Total Volume Shaft Motor Sound Sound Total
Fan Size Speed Fan Size Speed
flow rate Power power pressure power mass flow rate Power power pressure power mass
Volume Shaft Motor Sound Sound Total Volume Shaft Motor Sound Sound Total
Fan Size Speed Fan Size Speed
flow rate Power power pressure power mass flow rate Power power pressure power mass
A regular fan may sometimes not be appropriate, e.g. in gas-dangerous areas or in situations where
easy maintenance must be carried out on a fan. Heinen & Hopman also supplies special fans as
described below. Please contact us for more information.
Gas-freeing fans are used in gas-dangerous areas classified as zone 0 according to IEC 79-10, where
electric motors are not allowed. Fans can be applied for gas-freeing from tanks and holds of oil, gas
and chemical carriers.
The casing is made of carbon steel or hot-dip galvanized steel. The impeller is made of sea-water-
resistant aluminum, statically and dynamically balanced. The water turbine fan drive is made of bronze.
Portable fans
Portable fans are used in areas with chemically active vapors and gases. The portable fans are mostly
used on seagoing ships of unrestricted cruising area and on off-shore objects.
The fans are explosion-proof and made of sea-water-resistant aluminum, with a flexible hose
connection. The aluminum fans are pneumatically driven. The air turbine must be supplied with dry
and clean compressed air at a working pressure of 4-6 bar. The fan inlet has a protective brass-wire
guard.
In some installations, it is important to have access to the impeller or the motor without disassembling
the system. For this kind of applications, we recommend our fans with doors. With the impeller/motor
mounted on a swing-out access door, service and maintenance work can easily be done.
Explosion-proof fans extract air-containing explosive vapors or dust from hazard spaces of seagoing
ships of unrestricted cruising area. The fans have flame-proof EExd-class motors. The casing has a
drilled flange and a wire mesh on top. The impeller is made of sea-water-resistant aluminum.
www.heinenhopman.com