Ult. column load = 836 kN Safe bearing capacity = 120 kN/m2 B reqd
Self weight = 29 kN Overburden height = 0.60 m 2.33
Overburden = 77 kN Area of footing reqd. = 5.42 m2
Total load = 942 kN Footing size = 2.40 m A prvd.
Column breadth = 200 mm Area of footing prvd. = 5.76 m2 1
Column width = 400 mm Footing thickness = 400 mm
Net upward pressure = 145 kN/m2 Max. cantilever proj. = 1.10 m
As min
Max. B.M. /m width M = 88 kNm Z = 327 mm 447
K = M/bd2fcu = 0.025 N/mm2 As required /m width = 735 mm2 No of bars
Diameter of bars = 12 mm Spacing of bars = 150 mm 15
As provided/m width = 754 mm2 As prvd.
103%
Punch shear = 587 kN Dist. to critical section = 550 mm
Punch shear stress = 0.33 N/mm2 Shear force = 80 kN
Allow.shear stress = 0.39 N/mm2 Shear stress = 0.23 N/mm2 1
328% 1 345% 1
d. actual depth = 250 mm 100Asp/pd
P =(w+b)*2 for column = 1400 P at (1.5d) from face col. = 4400 mm 0.226
Vmax = 4.38 V = v * 1.15 /pd = 0.21 N/mm
Punch shear stress=v/pd = 0.57 1 Vc ( Allow shear stress) = 0.46 N/mm 1
130 912
sm
m
sm
Design of footing F2
fcu = 25 N/smm fy = 415 N/smm
Page 9
strip-base
@ #REF!
Page 10