CORBEL

Reaction from gantry girder 350


distance from fae 225
column size b 350
D 350
concrete grade 25 pt lim,% tc max
Rebar 415 1.19 3.1

bearing in steel plate cast


0.9 fck
taken bearing value 0.8 okk
bearing strength 20.000
design load 525.000
length of bearing plate 350.000 width of column
width of bearing plate 75.000
assumed width 100.000
depth of corbel at column face
tau,m considered 2.750 okk
d,required 545.455
clear cover 25.000
bar dia 12.000
D 576.455
also for strut action d should be more of 375.000 okk
assume D 600.000 OKK
d 569.000
alpha 0.122
gamma 0.395
alpha +gamma 0.517

z/d 0.713 0.052


z/d , taken 0.713
z 405.8128
xu 391.6493
xu/d 0.688312 over reinforced
xu,max/d 0.479
provide comp reinforcement 0.1
Ft 291.0825 > 262.5 okk
strain Es 0.001585 < 0.0038
fst 309.6827
Ast 939.9378
Ast provided 4 bars
452.736
pt 0.227334
tau,c 0.35
tau,m 1.770222
shear capacity 352.5398 shear reinforcement needed
shear bar dia 8 Fy
legged 2 250
spacing 179.6571
provide 170
horizontle stirup 226.368 provide in upper two third
bar dia 8
legged 2
number 4
area 402.432
Sv 94.83333
provide 90