Sunteți pe pagina 1din 3

ELECTRICAL MACHINES 1 (ENG203)

LAB PRACTICAL1
August 2016

TITLE: Operation of a DC Shunt Moto in Clockwise and Counter Clockwise


Rotation
EQUIPMENTS: Shunt Wound DC Machine
PROCEDURE / STEPS:

1. Shunt Wound machines are prepared by the lecturer.


2. Connections are made from the power supply to the machines
(Refer to machine notes for correct Voltage and Current levels)
3. Windage connections on each machines are made (refer to Diagram
1a)
4. Check the connections between power supply and machine as well as
winding connections.
5. Switch on the power and run the machine.
6. Troubleshoot if there is a problem
7. Switch off power and remove the connections when finish.
8. Repeat with the next motor setup (refer to Diagram 1b)
Clockwise Rotation

V=Voltage,v I=Current,A N=Speed,rpm


Minimum=20v 1.25A 150rpm
100v 0.65A 1800rpm
120v 0.70A 2000rpm
130v 0.75A 2125rpm
140v 0.75A 2225rpm
150v 0.75A 2400rpm
160v 0.79A 2500rpm
170v 0.80A 2610rpm
180v 0.85A 2750rpm
190v 0.85A 2900rpm
200v 0.88A 3000rpm

Counter-Clockwise Rotation

V=Voltage,V I=Current,A N=Speed,rpm


Minimum=20v 1.3A 150rpm
100v 0.70A 1850rpm
120v 0.73A 2075rpm
130v 0.75A 2190rpm
140v 0.76A 2300rpm
150v 0.79A 2420rpm
160v 0.80A 2500rpm
170v 0.82A 2620rpm
180v 0.85A 2800rpm
190v 0.88A 2900rpm
200v 0.90A 3000rpm