Cleaning web REPLACEMENT INSTRUCTIONS

2004.10
Ver. 1.0
1050/1050P cleaning web replacement procedure

(1) Purpose
To return to the normal operation as soon as possible after completion of the wind-up of the cleaning web.

(2) Procedure for removal


1. Turn OFF the sub power switch.

Sub
power
switch

1050fs5012z

2. Open the front door /Right and the front door /


Front door
Main power switch Front door Left, and then turn OFF the main power switch.
/Left
/Right
3. Unplug the power cord from the wall outlet.

Caution:
When conducting the replacement opera-
tions, be sure to turn OFF the main power
switch and the sub power switch and then
unplug the power cord from the wall outlet.
The cleaning web is installed at the fusing
unit. Since the fusing unit is very hot immedi-
ately after each of the power switches is
1050fs2001y turned OFF, you may get burnt. Be sure to
conduct the operation after the fusing unit
cools down sufficiently.

1
1050/1050P cleaning web replacement procedure

4. Bring down the pull-out lever to the right side


while pressing with a driver the lock release lever
in the arrow-marked direction, and pull out the
ADU.

ADU Pull-out lever

Lock release lever


1050fs2001z

5. Remove the 2 screws and then remove the web


Web cover cover.

Screw

1050fs2163c

2
1050/1050P cleaning web replacement procedure

6. Release the couplings provided at the 2 places in


the arrow-marked direction and remove the used
cleaning web.
Cleaning
web 7. When installing a new replacement part, see "(3)
Procedure for reinstallation" (on the next page).

Coup-
lings

1050fs2164c

3
1050/1050P cleaning web replacement procedure

(3) Procedure for reinstallation


1. Set the shaft on the unused side of the new
Driven couplings /Rear Shaft on the unused side cleaning web to the driven couplings /Rear and /
Front.
Notch
NOTE
Be sure to set each of the detent on the driven
couplings to the notch of the wind-up shaft.
Detent When the web is installed in the wrong direc-
tion, it does not coincide with the notch.

2. Hold either side of the wind-up shaft of the new


cleaning web with both hands, and take up the
new cleaning web until the blue line disappears.
Wind-up shaft

NOTE
The performance of the new cleaning web is
Cleaning
web guaranteed from the position in which the
blue line disappears. Be sure to take up the
cleaning web up to this position.

Either side
Blue
line

Driven
coup-
lings
/Front
Notch

Shaft on the unused side Detent


1050fs2165c

4
1050/1050P cleaning web replacement procedure

3. Install the wind-up shaft of the new cleaning web


Wind-up coupling /Front
to the wind-up couplings /Front and /Rear.

NOTE
Be sure to set each of the detent on the driven
coupling to the notch of the wind-up shaft.

Cleaning Wind-up Notch Detent


web shaft

Wind-up Wind-up shaft


coupling /Rear Detent Notch 1050fs2166c

4. Install the web cover with the 2 screws.


Web cover

Screw

1050fs2163z

5
1050/1050P cleaning web replacement procedure

5. Push in the ADU while holding the pull-out lever


by hand, and then lock the pull-out lever.

NOTE
When the ADU is brought back to its original
position, be sure to lock the pull-out lever.

ADU Pull-out lever


1050fs2001w

6. Plug the power cord into the wall outlet.


Front door Main power switch Front door 7. Turn ON the main power switch and close the
/Left /Right
front door /Left and the front door /Right.

1050fs2001x

8. Turn ON the sub power switch.

Sub
power
switch

1050fs5012z