near Piacenza. A) Using the residential load factor method, calculate the cooling and heating
loads of the building considering the following characteristics:
-The external wall, that is built around 38 mm - 90 mm wood studs, is made up of the
following layers (internal to external):
- The summer and winter U value of the roof can be considered to be 0.25 W/(m2 K). The
external surface of the roof can be considered as asphalt shingles with medium colour.
-All of the windows are made of heat absorbing double layer glass with a wooden frame.
- Windows on the west and east walls are supposed to be fixed. The window on the south
wall is considered to be half operable (with insect net) and half fixed.
- All of the windows have a 90 cm shading which is located 30 cm above the windows
- Internal Shading of all of the windows is an open-weave light drape which is 40% closed.
- Consider the ventilation and infiltration to be independent and the take into account the
following properties for Air: Cs=1. 23 W/(L. s. K), Cl=3010 (W/(L.s)
- HVAC system (furnace based) is in the attic with the leakage rate of 5% and R-1.4