Documente Academic
Documente Profesional
Documente Cultură
FORTIGEN
GENEVA - NEBRASKA
STORAGE & TRUCK LOADING
CALCULATION
OPERATIONAL PLATFORM FOR E-1500
REPORT
FOUNDATION
GORH-2023-C-MC-17 REV. 0
REV: 0
DATE: 08/25/2017
FORTIGEN
DOC: GORH-2023-C-MC-17
GENEVA-NEBRASKA
CALCULATION REPORT PAGE: 2 of 28
INDEX
INDEX ......................................................................................................................................................2
OVERVIEW ...............................................................................................................................................3
DESCRIPTION ..........................................................................................................................................4
CODES......................................................................................................................................................4
MATERIALS ..............................................................................................................................................5
SOIL ........................................................................................................................................ 5
CONCRETE ............................................................................................................................... 5
STEEL REINFORCEMENT ........................................................................................................... 5
LOADS ......................................................................................................................................................5
WIND ...................................................................................................................................... 5
EARTHQUAKE ........................................................................................................................... 6
PLATFORM REACTIONS............................................................................................................. 7
LOAD COMBINATIONS.............................................................................................................................10
ASCE 7-10 ASD ...................................................................................................................... 10
ASCE 7-10 LRFD .................................................................................................................... 11
PLATFORM FOUNDATION ....................................................................................................................12
SOIL PRESSURE........................................................................................................................ 12
REINFORCING MAT BS-20 - A .................................................................................................. 13
REINFORCING MAT BS-20 - B .................................................................................................. 16
REINFORCING MAT BS-20 - C .................................................................................................. 19
REINFORCING MAT BS-20 - D ................................................................................................. 22
COLUMN DESIGN 17 x 17 in FLEXO-COMPRESSION ................................................................. 25
COLUMN DESIGN 17 x 17 in SHEAR ........................................................................................ 27
REV: 0
DATE: 08/25/2017
FORTIGEN
DOC: GORH-2023-C-MC-17
GENEVA-NEBRASKA
CALCULATION REPORT PAGE: 3 of 28
OVERVIEW
In this report we are designing and checking the Foundation for operational platform of equipment E-1500.
It is composed of concrete footings.
DATE: 08/25/2017
FORTIGEN
DOC: GORH-2023-C-MC-17
GENEVA-NEBRASKA
CALCULATION REPORT PAGE: 4 of 28
DESCRIPTION
CODES
DATE: 08/25/2017
FORTIGEN
DOC: GORH-2023-C-MC-17
GENEVA-NEBRASKA
CALCULATION REPORT PAGE: 5 of 28
MATERIALS
SOIL
a = 1500 lb/ft2
K = 96.5 kip/ft3
CONCRETE
fc = 4000psi
STEEL REINFORCEMENT
ASTM 615 Grade 60
LOADS
Specific weights
Steel: 491 pcf
Concrete: 150 pcf
WIND
ASCE 7-10
Velocity Pressure
qz = 0.00256 Kz Kzt Kd V2 qz = 26.63 Lb/ft2
ASCE7-10:
REV: 0
DATE: 08/25/2017
FORTIGEN
DOC: GORH-2023-C-MC-17
GENEVA-NEBRASKA
CALCULATION REPORT PAGE: 6 of 28
EARTHQUAKE
ASCE 7-10
IMPORTANCE FACTOR AND RISK CATEGORY
Risk Category III Table 1.5-1
Importance Factor, Table 1.5-2
DATE: 08/25/2017
FORTIGEN
DOC: GORH-2023-C-MC-17
GENEVA-NEBRASKA
CALCULATION REPORT PAGE: 7 of 28
Site Class D
Ss = 0.112
S1 = 0.045
Fa = 1.60
Fv = 2.40
SMS = Fa Ss = 0.1792
SM1 = Fv S1 = 0.1080
SDS = 0.1195
R = response modification factor
R = 3.0
Ie = 1.25
Cs = 0.050
PLATFORM REACTIONS
DATE: 08/25/2017
FORTIGEN
DOC: GORH-2023-C-MC-17
GENEVA-NEBRASKA
CALCULATION REPORT PAGE: 8 of 28
Joint OutputCase F1 F2 F3 M1 M2 M3
Kgf Kgf Kgf Kgf-m Kgf-m Kgf-m
1 D -0.86 -207.08 -1754.05 154.15 -2.18 -0.11
1 L -4.07 17.75 -1255.94 24.64 -10.30 -0.57
1 WX+ 66.84 -0.84 60.61 -6.08 40.54 0.00
1 WX- -66.84 0.84 -60.61 6.08 -40.54 0.00
1 WY+ 0.43 209.24 183.33 -231.78 1.09 0.02
1 WY- -0.43 -209.24 -183.33 231.78 -1.09 -0.02
1 EX+ 0.89 -1.16 8.94 0.31 2.25 0.00
1 EX- -0.82 1.52 -8.61 -0.70 -2.09 0.00
1 EY+ 0.08 56.82 42.46 -75.32 0.20 0.01
1 EY- -0.08 -56.82 -42.46 75.32 -0.20 -0.01
1 S -1.04 4.52 -320.27 6.28 -2.63 -0.14
3 D 0.09 199.54 -1070.86 -164.67 0.22 0.02
3 L 0.30 61.37 -738.61 -31.11 0.71 0.08
3 WX+ 50.88 5.37 3.02 -9.32 28.30 0.10
3 WX- -50.88 -5.37 -3.02 9.32 -28.30 -0.10
3 WY+ -0.24 188.56 -184.87 -225.17 -0.61 -0.03
3 WY- 0.24 -188.56 184.87 225.17 0.61 0.03
3 EX+ 0.91 0.68 -0.89 -0.93 2.30 0.00
3 EX- -0.26 -0.45 0.55 0.61 -0.67 -0.01
3 EY+ -0.02 51.41 -50.46 -74.01 -0.06 0.00
3 EY- 0.02 -51.41 50.46 74.01 0.06 0.00
3 S 0.08 15.65 -188.35 -7.93 0.18 0.02
9 D -0.61 -232.03 -1585.57 187.80 -1.54 -0.04
9 L -2.88 -215.56 -1650.15 167.49 -7.29 -0.19
9 WX+ 51.50 -9.94 -21.68 13.03 29.88 -0.09
9 WX- -51.50 9.94 21.68 -13.03 -29.88 0.09
9 WY+ 0.35 386.71 385.23 -517.08 0.88 0.01
9 WY- -0.35 -386.71 -385.23 517.08 -0.88 -0.01
9 EX+ 0.83 0.04 0.09 -0.06 2.10 0.00
9 EX- -0.77 -0.28 -0.42 0.40 -1.94 0.00
9 EY+ 0.06 110.87 97.05 -162.00 0.15 0.00
9 EY- -0.06 -110.87 -97.05 162.00 -0.15 0.00
9 S -0.73 -54.97 -420.78 42.71 -1.86 -0.05
11 D 0.08 207.41 -1185.68 -168.60 0.20 0.02
11 L 0.26 218.00 -1626.84 -184.16 0.64 0.08
11 WX+ 50.79 -6.11 0.92 9.93 28.07 0.11
11 WX- -50.79 6.11 -0.92 -9.93 -28.07 -0.11
11 WY+ -0.22 381.35 -324.40 -512.54 -0.54 -0.03
11 WY- 0.22 -381.35 324.40 512.54 0.54 0.03
11 EX+ 0.82 0.04 -0.07 -0.06 2.09 0.00
11 EX- -0.34 -0.29 0.41 0.41 -0.88 0.00
11 EY+ -0.02 110.72 -97.06 -161.85 -0.05 0.00
11 EY- 0.02 -110.72 97.06 161.85 0.05 0.00
11 S 0.07 55.59 -414.84 -46.96 0.16 0.02
REV: 0
DATE: 08/25/2017
FORTIGEN
DOC: GORH-2023-C-MC-17
GENEVA-NEBRASKA
CALCULATION REPORT PAGE: 9 of 28
DATE: 08/25/2017
FORTIGEN
DOC: GORH-2023-C-MC-17
GENEVA-NEBRASKA
CALCULATION REPORT PAGE: 10 of 28
LOAD COMBINATIONS
SC1 = 1.0 D
SC2 = 1.0 D + 1.0 L
SC3 = 1.0 D + 1.0 S
SC4 = 1.0 D + 0.75 L + 0.75 S
SC5A = 1.0 D + 0.6 WX+
SC5B = 1.0 D + 0.6 WX-
SC5C = 1.0 D + 0.6 WY+
SC5C = 1.0 D + 0.6 WY-
SC6A = 1.0 D + 0.7 EX+
SC6B = 1.0 D + 0.7 EX-
SC6C = 1.0 D + 0.7 EY+
SC6D = 1.0 D + 0.7 EY-
SC7A = 1.0 D +0.75 L + 0.75 S + 0.45 WX+
SC7B = 1.0 D +0.75 L + 0.75 S + 0.45 WX-
SC7C = 1.0 D +0.75 L + 0.75 S + 0.45 WY+
SC7D = 1.0 D +0.75 L + 0.75 S + 0.45 WY-
SC8A = 1.0 D +0.75 L + 0.75 S + 0.525 EX+
SC8B = 1.0 D +0.75 L + 0.75 S + 0.525 EX-
SC8C = 1.0 D +0.75 L + 0.75 S + 0.525 EY+
SC8D = 1.0 D +0.75 L + 0.75 S + 0.525 EY-
SC9A = 0.6 D + 0.6 WX+
SC9B = 0.6 D + 0.6 WX-
SC9C = 0.6 D + 0.6 WY+
SC9D = 0.6 D + 0.6 WY-
SC10A = 0.6 D + 0.7 EX+
SC10B = 0.6 D + 0.7 EX-
SC10C = 0.6 D + 0.7 EY+
SC10D = 0.6 D + 0.7 EY-
Where:
D: Foundation weight, Equipment weight, Platform weight
L: Platform overload
S: Snow load
WX+: Wind Force in direction X+
WX-: Wind Force in direction X-
WY+: Wind Force in direction Y+
WY+: Wind Force in direction Y+
EX+: Seismic force in direction X+
EX-: Seismic force in direction X-
EY+: Seismic force in direction Y+
EY-: Seismic force in direction Y-
REV: 0
DATE: 08/25/2017
FORTIGEN
DOC: GORH-2023-C-MC-17
GENEVA-NEBRASKA
CALCULATION REPORT PAGE: 11 of 28
DES1 = 1.4 D
DES2 = 1.2 D + 0.5 S + 1.6 L
DES3 = 1.2 D + 1.6 S + 1.0 L
DES4A = 1.2 D + 1.6 S + 0.5 WX+
DES4B = 1.2 D + 1.6 S + 0.5 WX-
DES4C = 1.2 D + 1.6 S + 0.5 WY+
DES4D = 1.2 D + 1.6 S + 0.5 WY-
DES5A = 1.2 D + 0.5 S + 1.0 L + 1.0 WX+
DES5B = 1.2 D + 0.5 S + 1.0 L + 1.0 WX-
DES5C = 1.2 D + 0.5 S + 1.0 L + 1.0 WY+
DES5D = 1.2 D + 0.5 S + 1.0 L + 1.0 WY-
DES6A = 1.2 D + 0.2 S + 1.0 L + 1.0 EX+
DES6B = 1.2 D + 0.2 S + 1.0 L + 1.0 EX-
DES6C = 1.2 D + 0.2 S + 1.0 L + 1.0 EY+
DES6D = 1.2 D + 0.2 S + 1.0 L + 1.0 EY-
DES7A = 0.9 D + 1.0 WX+
DES7B = 0.9 D + 1.0 WX-
DES7C = 0.9 D + 1.0 WY+
DES7D = 0.9 D + 1.0 WY-
DES8A = 0.9 D + 1.0 EX+
DES8B = 0.9 D + 1.0 EX-
DES8C = 0.9 D + 1.0 EY+
DES8D = 0.9 D + 1.0 EY-
Where:
D: Foundation weight, Equipment weight, Platform weight
L: Platform overload
S: Snow load
WX+: Wind Force in direction X+
WX-: Wind Force in direction X-
WY+: Wind Force in direction Y+
WY+: Wind Force in direction Y+
EX+: Seismic force in direction X+
EX-: Seismic force in direction X-
EY+: Seismic force in direction Y+
EY-: Seismic force in direction Y-
REV: 0
DATE: 08/25/2017
FORTIGEN
DOC: GORH-2023-C-MC-17
GENEVA-NEBRASKA
CALCULATION REPORT PAGE: 12 of 28
PLATFORM FOUNDATION
SOIL PRESSURE
Foundation Combination Reaction Influence Area Tension on ground Admissible tension Check
Lb ft2 Lb/ft2 Lb/ft2
BS-20 A SC7D 20.40 0.0256 796.88 1500.00 OK
BS-20 B SC7D 21.05 0.0256 822.30 1500.00 OK
BS-20 C SC7B 28.35 0.0256 1107.42 1500.00 OK
BS-20 D SC7B 18.94 0.0256 739.80 1500.00 OK
REV: 0
DATE: 08/25/2017
FORTIGEN
DOC: GORH-2023-C-MC-17
GENEVA-NEBRASKA
CALCULATION REPORT PAGE: 13 of 28
DATE: 08/25/2017
FORTIGEN
DOC: GORH-2023-C-MC-17
GENEVA-NEBRASKA
CALCULATION REPORT PAGE: 14 of 28
DATE: 08/25/2017
FORTIGEN
DOC: GORH-2023-C-MC-17
GENEVA-NEBRASKA
CALCULATION REPORT PAGE: 15 of 28
As = Mu
fy ( d - a/2 )
a= As fy
0.85 f'c B
DATE: 08/25/2017
FORTIGEN
DOC: GORH-2023-C-MC-17
GENEVA-NEBRASKA
CALCULATION REPORT PAGE: 16 of 28
DATE: 08/25/2017
FORTIGEN
DOC: GORH-2023-C-MC-17
GENEVA-NEBRASKA
CALCULATION REPORT PAGE: 17 of 28
DATE: 08/25/2017
FORTIGEN
DOC: GORH-2023-C-MC-17
GENEVA-NEBRASKA
CALCULATION REPORT PAGE: 18 of 28
As = Mu
fy ( d - a/2 )
a= As fy
0.85 f'c B
DATE: 08/25/2017
FORTIGEN
DOC: GORH-2023-C-MC-17
GENEVA-NEBRASKA
CALCULATION REPORT PAGE: 19 of 28
DATE: 08/25/2017
FORTIGEN
DOC: GORH-2023-C-MC-17
GENEVA-NEBRASKA
CALCULATION REPORT PAGE: 20 of 28
DATE: 08/25/2017
FORTIGEN
DOC: GORH-2023-C-MC-17
GENEVA-NEBRASKA
CALCULATION REPORT PAGE: 21 of 28
As = Mu
fy ( d - a/2 )
a= As fy
0.85 f'c B
DATE: 08/25/2017
FORTIGEN
DOC: GORH-2023-C-MC-17
GENEVA-NEBRASKA
CALCULATION REPORT PAGE: 22 of 28
DATE: 08/25/2017
FORTIGEN
DOC: GORH-2023-C-MC-17
GENEVA-NEBRASKA
CALCULATION REPORT PAGE: 23 of 28
DATE: 08/25/2017
FORTIGEN
DOC: GORH-2023-C-MC-17
GENEVA-NEBRASKA
CALCULATION REPORT PAGE: 24 of 28
As = Mu
fy ( d - a/2 )
a= As fy
0.85 f'c B
DATE: 08/25/2017
FORTIGEN
DOC: GORH-2023-C-MC-17
GENEVA-NEBRASKA
CALCULATION REPORT PAGE: 25 of 28
SUMMARY OF FORCE
In Fig. 17 shows the section of the shaft with dimensions and distribution of the reinforcement.
In Fig. 18 shows the interaction diagram axial load - Moment of the column of 17 in x 17 in with reinforcement
of 4 # 6 + 4 #5.
In Fig. 19 shows the Moment-Moment interaction diagram for axial load of 11.72 Kip.
As you can see the values of forces are within the diagrams mentioned by what checks the column with the
amount of reinforcement indicated.
DATE: 08/25/2017
FORTIGEN
DOC: GORH-2023-C-MC-17
GENEVA-NEBRASKA
CALCULATION REPORT PAGE: 26 of 28
DATE: 08/25/2017
FORTIGEN
DOC: GORH-2023-C-MC-17
GENEVA-NEBRASKA
CALCULATION REPORT PAGE: 27 of 28
VU2 VU3
Foundation Combination
Kip Kip
DES5B 0.16 -
BS-20 A
DES5C - 1.10
DES5B 0.12 -
BS-20 B
DES5D - 2.00
DES5B 3.07 -
BS-20 C
DES5D - 2.04
DES5B 2.20 -
BS-20 - D
DES5C - 1.37
DATE: 08/25/2017
FORTIGEN
DOC: GORH-2023-C-MC-17
GENEVA-NEBRASKA
CALCULATION REPORT PAGE: 28 of 28