Sunteți pe pagina 1din 49

FOUNDATION

Introduction to Foundation Engineering


Bearing Capacity of Foundation
FOUNDATION
To transfer the load of the structure to the soil

Considerations:
Settlement of the structure
Shear failure of the soil under the foundation
Types of Foundation
SHALLOW FOUNDATIONS
Depth of embedment-to-width ratio of approximately less
than four (4)

SPREAD FOOTING
Enlargement of a load-bearing wall or column to spread the
load of the structure over a larger area

MAT FOUNDATION
Concrete pad where the entire structure is supported
Spread Footing
Spread Footing
Mat Foundations
Types of Foundation
DEEP FOUNDATION
depth of embedment-to-width ratio of foundation greater
than four

PILE FOUNDATION
FRICTION PILES shear resistance along the surface of the pile
END BEARING PILES load is transmitted at the tip to a firm
stratum of soil

DRILLED SHAFT FOUNDATION


Shaft drilled in the subsoil is then filled with concrete
Pile Foundation
Drilled Shaft Foundation
SOIL BEARING CAPACITY FOR SHALLOW
FOUNDATIONS

Terzaghis Ultimate Bearing Capacity Equation


Effect of Groundwater Table
Allowable Bearing Capacity
General Bearing Capacity Equation
Foundation with Moment Loads
Bearing Capacity of Foundations on Slopes
Plate Load Test
Ultimate Bearing Capacity
Two Modes of Bearing Capacity Failure

General Shear Failure

Dense Sand

Local Shear Failure


Loose to Medium
Dense Sand

Zone II - radial shear zone (logarithmic spirals)


Zone III linear shear zone (planar surfaces)
Terzaghis Bearing Capacity Analysis

Shallow foundation criterion:


depth Df width B

Weight of the soil above the base of the


footing may be replaced by an
equivalent surcharge, q = Df

Failure mechanism: general shear


failure, with AJ and BJ making an angle
of with respect to the horizontal

Rupture lines: JD and JE are arcs of


logarithmic spiral

Passive force: inclined at an angle


(angle of wall friction) with respect to the
perpendicular drawn to the wedge faces
and , but =
Terzaghis Bearing Capacity Analysis

By equilibrium:
Terzaghis Bearing Capacity Analysis

PASSIVE FORCE, Pp
Sum of the contribution of the weight of soil (), cohesion
(c), and surcharge (q) such that:
Terzaghis Bearing Capacity Analysis

Substituting:
Terzaghis Bearing Capacity Analysis

Approximating the value of ultimate bearing


capacity equation:
Terzaghis Bearing Capacity Equation

By superposition:

Where:

Nc
Nq bearing capacity factors
N
Terzaghis Ultimate Bearing Capacity Equations
Terzaghis Ultimate Bearing Capacity Equations
Effect of Groundwater Table
Effect of Groundwater Table
Effect of Groundwater Table
Factor of Safety
GROSS ALLOWABLE BEARING CAPACITY
Factor of Safety
NET ALLOWABLE BEARING CAPACITY
Factor of Safety
GROSS ALLOWABLE BEARING CAPACITY WITH A
FACTOR OF SAFETY WITH RESPECT TO SHEAR
FAILURE
PROBLEM

Ans.
1. 225.220 kPa for FS =3
168.915 kPa for FS = 4
2. 166.215 kPa
3. 60.872 kPa
PROBLEM

Ans.
1. 149.032 kPa
2. 141.970 kPa
3. 93.204 kPa
PROBLEM
A circular footing having a diameter of 2.5m is supported by a
soil with the following properties:

= 27 = 20.4 kN/m3
c = 38.4 kPa sat = 22.3 kN/m3

The bottom of the footing is 2m below the ground surface.


GWT is located 2m below the ground surface. Using
Terzaghis equation, determine the gross allowable bearing
capacity, net allowable bearing capacity and gross allowable
bearing capacity with factor of safety with respect to shear
failure . Assume local shear failure. Use w = 9.81 kN/m3.
PROBLEM
A square footing having a width of 5m is supported by a
soil with the ff. properties:

= 32 = 17.5 kN/m3
c = 30 kPa

The bottom of the footing is 3.2m below the ground


surface. Using Terzaghis equation, determine the
footings gross allowable bearing capacity with a factor
of safety of 4 with respect to shear failure.
General Bearing Capacity Equation

Where:

and

and

and
General Bearing Capacity Equation
General Bearing Capacity Equation

For values of q and , consider the effect of


groundwater table.
PROBLEM
Footing with Eccentric or Moment Loads

Effective footing
dimensions:

Effective Area:
Footing with Eccentric or Moment Loads

Use effective width in computing the allowable


bearing capacity

Example, using the general bearing capacity equation:


Footing with Eccentric or Moment Loads

Design the footing so that the equivalent net


bearing pressure does not exceed the allowable
bearing capacity
PROBLEM
Plate Load Test
ASTM D-1194
Plate Load Test
Plate Load Test

ULTIMATE BEARING CAPACITY


Plate Load Test

SETTLEMENT
Plate Load Test

BEARING CAPACITY FOR


COHESIVE SOIL (HOUSEL)
PROBLEM
PROBLEM

S-ar putea să vă placă și