1. Introduction ................................................................................................................. 3
1.1 Scale Control ............................................................................................................. 3
1.2 Corrosion Control ..................................................................................................... 3
2. Typical Installations .................................................................................................... 5
3. Product Specifications ................................................................................................. 6
3.1 DAC-Customized Power Unit .................................................................................. 6
3.2 Standard In-Tank Emitter/Emitter Receiver Specifications ..................................... 8
4. Operation and Maintenance ........................................................................................ 9
1.1 System operation .................................................................................................. 9
4.2 Water Care and Conditions ..................................................................................... 10
4.3 Maintenance ............................................................................................................ 12
4.4 Troubleshooting ...................................................................................................... 13
4.5 Spare Part list .......................................................................................................... 13
5. Testing and Commissioning....................................................................................... 14
6. Performance Monitoring ........................................................................................... 14
2
2014 Ecospec Global Technology Pte Ltd
1. Introduction
1. Introduction
Boiler feed water is treated by ScaMag ULF (ultra Low Frequency) electromagnetic
pulses, its calcium ions will either remain in dissolved state in the water or
precipitates as fine powdery Aragonite in water. Hence, hard scale Calcite calcium
carbonate precipitation on the tube wall will be effectively controlled.
With ScaMag treatment, existing scale will gradually dissolve back into the water
and descaling will take place. This results in a cleaner boiler water system and
effective in controlling under deposit corrosion.
Corrosion activities in boiler water are caused by Fe ions production and its severity
is dependent on the Fe ions concentration in the water. ScaMag can effectively
control the corrosion activities in the boiler water system and it is able to control the
Fe ions level to below 5 ppm.
4
2014 Ecospec Global Technology Pte Ltd
2. Typical Installations
The typical installation diagram for boiler water treatment application is shown in Figure
1 below. An In-tank Emitter (metal part) is to be submerged in the feed water and
aligned to the center of the tank to ensure even distribution of ionic potential. The Emitter
Receiver is to be mounted above the water line, i.e. either by welding or bolting to the
feed water tank. Meanwhile, the power unit should be installed as close as possible to the
feed water tank, and it is advisable to be installed in the zone where it is less affected by
heat and direct exposed to sunlight, rain etc.
5
2014 Ecospec Global Technology Pte Ltd
3. Product Specifications
DAC-Customized Specifications
Model ScaMag DAC-Customized
Circuit control CPU
Casing material Mild Steel Enclosure
Service 6Ton/hr Boiler
Power 4. Inductor Coil Specifications
AC80V-260V/60Hz-50Hz,750W
Weight 8kg
Size 600mm x400mm x 250mm (W x H x D)
6
2014 Ecospec Global Technology Pte Ltd
Figure 3: Interior of power unit, with wires connection to emitter (in red) and emitter
receiver (in blue)
Above showing the interior of the power unit with various components but the key one
includes the ULF driver card, a power supply, and a DC controller. ScaMag is a two wire
system where the red line indicate the connection point to the In-Tank Emitter and the
blue line to the Emitter Receiver. The detailed design of the emitters can refer to the
followng Figure 4 (subject to change depends on site condition and tank size).
7
2014 Ecospec Global Technology Pte Ltd
3.2 Standard In-Tank Emitter/Emitter Receiver Specifications
Figure 4: Dimensional drawings of In-tank Emitter (left) and Emitter Receiver (right).
8
2014 Ecospec Global Technology Pte Ltd
6. Troubleshooting
With refer to Figure 2, the selector main switch regulates the ON, OFF mode of the
system. During the ON mode, Ultra Low Frequency (ULF) electromagnetic pulses will
be activated and system is shut off when the switch is turned to OFF mode. The
operating sequence are as follow:
ON Sequence
OFF Sequence
9
2014 Ecospec Global Technology Pte Ltd
4.2 Water Care and Conditions
BacComber non-chemical water treatment program for boilers system has proven to be
effectively against scaling and corrosion. A water analysis program is essential with
BacComber water treatment and should be carried out in line with the use of the system.
Understanding the water conditions before and after the use of the BacComber system
helps in the assessment of the treatment effects. In addition, regular monitoring of the
water conditions after the use of the BacComber treatment system helps to maintain good
water quality for optimum effects.
After installation of the BacComber system, it is preferred that the boiler feed water and
boiler water analysis to be conducted every other day for the first two weeks
(recommended) until the results reflect a relative stable water quality. Then on, followed
by weekly for three months and then monthly water analysis thereafter should be
conducted, and the water quality should be monitored closely concurrently. Pls refer to
appendix B. Post Commissioning Performance and Water Monitoring Data Log Sheet to
assist in up-keeping this record.
The parameters that need to be routinely monitored for BacComber boiler treatment are:
pH, Conductivity or Total Dissolved Solid (TDS), Fe ion, total hardness and alkalinity for
both boiler feed water and boiler water.
The interpretation of the water test results is illustrated in the following table.
10
2014 Ecospec Global Technology Pte Ltd
Parameters Unit Desired Range Remarks
and Limit for
Boiler Water
11
2014 Ecospec Global Technology Pte Ltd
4.3 Maintenance
Minimal maintenance is required for ScaMag Boiler Water Treatment system.
Nonetheless, to ensure the proper functioning of the system, following maintenance
routine should be carried out periodically as such:
ScaMag system should be kept on at all time to ensure effective water treatment
Ensure that all LEDs on the power unit have its green indication light constantly
on
During system intervals, check the current reading against what was recorded at
the beginning of operation. Ensure that the current readings have no extreme
deviation. Please refer to readings as recorded in the post commissioning
performance and water monitoring data log sheet in Appendix B.
Check any damages or corrosion on the electrical components inside the power
unit.
Regular blow down of the feed and boiler water to ensure the water parameters
are within control limit and perform within the capability of the system.
12
2014 Ecospec Global Technology Pte Ltd
4.4 Troubleshooting
Troubleshooting Tips:
When testing the control panel, emitters should be connected (unless otherwise
noted). If either end is not connected, the results may be inaccurate.
Always keep a small jumper wire or small test-pen in your toolbox for
troubleshooting.
Unless otherwise noted, ALWAYS remove power from the machine before testing
any wires to avoid electrical shock.
If you require assistance in troubleshooting, please have the serial number and a
description of the problem available before calling.
2 DC Controller
13
2014 Ecospec Global Technology Pte Ltd
5. Testing and Commissioning
Refer to appendix A.
6. Performance Monitoring
Refer to appendix B.
14
2014 Ecospec Global Technology Pte Ltd
Ecospec Global Technology Pte Ltd
60 Admiralty Road West
Singapore 759956
Tel: (65) 6752 2222 Fax: (65) 6758 2657
www.ecospec.com