Sunteți pe pagina 1din 4

Eatons IQ 100X electronic power meter

High-end power management performance

Optional Modbus RTU can be confidently used for


communications primary revenue metering and
Prepared for the future submetering applications.
the meters are designed Eatons IQ 100X meters provide
to accommodate firmware direct-reading metered values
upgrades and capabilities for the most critical power
Integrate into Eatons Power aspects, such as watts, watt
Xpert Architecture for a demand, watthours, voltage-
holistic system-level view amperes (VA), VA-hours, vars,
varhours and power factor.
They have high sampling
High-end capabilities you speed and accuracy.
IQ 100X Electronic Power Meter
would not expect from an
ultra-compact meter Is the utility company billing
accurately? The IQ 100X models
Introduction Typical applications Providing the first line of defense provide a traceable watthour test
against costly power problems, pulse (used with a watthour pulse
With energy costs skyrocketing, Utility and commercial
Eatons IQ 100X electronic power recorder or totalizer), so you can
you need the ability to verify metering
meters can perform the work of verify the accuracy of your meter
the accuracy of utility billing Substations, industrial
an entire wall of legacy metering and, in turn, the accuracy of bill-
and allocation of energy costs facilities, power generation equipment utilizing todays tech- ing from the utility company and
among business units, different sites and campuses nology. Eatons IQ 100X meters to internal customers.
manufacturing areas or facilities,
Submetering sample at a higher rating of
and tenants. Production equip- The meters are designed to
samples per cycle and meet
ment and IT systems are Load studies and voltage integrate into Eatons Power
ANSI C12.20 standards for
vulnerable to power anomalies; recording Xpert Architecture for end-to-
accuracy of 0.5 percent. With
therefore, you must ensure that end management of your entire
Analog meter replacement such high-performance measure-
power is always up to specifica- power system, giving you a
ment capability, these meters
tions. If your infrastructure is holistic system-level view.
an established facility, you may Features and benefits
have addressed these concerns Measure and display real-
in the past by deploying a time information about critical
variety of analog gauges and power parameters with a
metersone for volts, one high rate of sampling
for amperes and so on, with
separate meters for each Monitor power utilization and
measurement. quality with ANSI C12.20
accuracy (0.5 percent)
If youre planning an upgrade
or new power infrastructure,
no doubt you would like to
capitalize on the latest tech-
nology to improve upon that
cumbersome architecture and
its patchwork view.
Features of IQ 100X Electronic Power Meters Industry-standard Designed for the user
communication protocols
Features When space is at a premium,
Instrumentation IQ 100X meters use the optional yet you need ANSI C12.20
Modbus protocol. This industry- accuracy, Eaton IQ 100X meters
Current, per phase X
standard protocol provides serial fit the bill. These ultra-compact
Current demand X communications with Eaton or meters are ideal for electrical
Calculated neutral current X third-party platforms, such as a equipment assemblies, machine
Voltage, per phase (LL, LN) X building-management system, control panels (such as panel-
power-management system or board and switchboard mains
Min./max. readings, I, V X Eatons Power Xpert Gateway and feeders), low voltage
Min./max. readings, I, V, PF, F, X for Web-based monitoring metal-enclosed switchgear
W, VAR, VA as part of Eatons Power Xpert feeders and motor control
Frequency X Architecture. centers. Requiring far less
Power
space than other meters with
Integrated with Eatons similar functionality, IQ 100X
Real, reactive and apparent X Power Xpert Architecture meters fit into a standard
power, total ANSI or IEC cutout on a panel-
(W, VAR, VA) IQ 100X meters integrate board or other electrical
Power factor, total X into Eatons Power Xpert equipment and, therefore, fit
Real, reactive and apparent X Architecture, where meters, easily into retrofit applications.
power demand gateways and monitoring
devices collaborate to create Most meters in this class have
Demand Methods small or dark displays that can
a unified, centralized view of
Block interval (sliding, fixed) X the end-to-end power and be hard to see, especially from a
Energy facility infrastructure. distance. Eatons IQ 100X meters
have a easy to read display, even
Real, reactive and apparent X When used in this architecture if the meter is installed at a
energy, total and in conjunction with Eatons
(Wh, VAR, VAh) height or distance. Using the
Power Xpert Gateway, IQ 100X keypad and menus on the local
Communications meters with the Modbus RTU display, users can display a variety
RS-485, Modbus RTU, Opt option can provide Web-based of electrical system values or
graphics of current power condi- program the meter.
6DI+4DO+1AO Opt
tions. Simply connect your meter
to a Power Xpert Gateway to
translate Modbus-based
information from the meter into
HTML-based Web pages that are
accessible from any standard
Web browser. With access
to accurate, real-time information
from IQ 100X meters, the Power
Xpert Architecture can transform
your power system into an
integrated, agile system, and an
easily managed entity that
IQ 100X Dimensions performs better and costs less.
Unit: mm

2 EATON CORPORATION Eatons IQ 100X electronic power meter


IQ 100X Meter Ordering Information

IQ 100X M A 6 5 1 1

Model Series Meter Type Frequency Current Input Power Supply Communication
100X = Energy M = Meter (with 5 = 50/60 Hz system 1 = 1A secondary 1 = 75-250 Vac/dc 0 = I/O Card
integral display) 5 = 5A secondary 1 = Modbus RTU
2 = I/O Card+ Modbus RTU

IQ 100X Electronic Power Meter Technical Information

Current Inputs Update Rate


Class 10 5A nominal Watts, VAR and VA 100 msec at 60 Hz
Class 2 1A nominal All other parameters 1 second at 60 Hz
Fault Current Withstand
20 Ie 1 second Power Supply
Programmable current Full scale to any CT ratio AC voltage option 75-250Vac at 50/60 Hz
Burden 0.005 VA per phase max. at 11A 0.005 VA per phase max. at 11A
Pickup current 0.1% of nominal 0.1% of nominal Optional Communications Format
Class 10 5 mA 5 mA
Connection type RS-485
Class 2 1 mA 1 mA Com. port baud rate 960057,600 Bauds
Com. port address 01247
Voltage Inputs Data format 8-bit, no parity
Range Protocols Modbus, RTU
Line-to-neutral 20416 Vac
Line-to-line 20721 Vac Dimensions and Shipping
Programmable voltage range Full scale to any PT ratio Basic unit H 96 x W 96 x L 83.5 mm
Input impedance 1 megohm/phase
Compliance
Isolation IEC 687 0.5% accuracy
All inputs and outputs are galvanically isolated to 2000V ANSI C12.20 0.5% accuracy

Environmental Ratings
Operating temperature 20C to +70C
Storage temperature 20C to +70C
Operating humidity To 95% RH noncondensing

EATON CORPORATION Eatons IQ 100X electronic power meter 3


Eaton is a power management company with 2014 sales of $22.6
billion. Eaton provides energy-efficient solutions that help our
customers effectively manage electrical, hydraulic and
mechanical power more efficiently, safely and sustainably. Eaton
has approximately 102,000 employees and sells products to
customers in more than 175 countries. For more information, visit
www.eaton.com.

Eaton Corporation
Electrical Sector
No.3, Lane 280, Linhong Road,
Changning District,
Shanghai 200335
www.eaton.com
Eaton is a registered trademark
2015 Eaton Corporation of Eaton Corporation.
All Rights Reserved
Printed in China All other trademarks are property
PA02601008E / TN-EN (02-2015) of their respective owners.